Differential Scanning Calorimeter
Filter
Showing 91–120 of 207 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1 |
| Temperature Range | −150 to 700 °C (configurable low-end: −150, −100, −90, −70 or −35 °C) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor), 0.01 µW (HSS8 sensor) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | –150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor) |
| Sensor Configuration | 56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry |
| Compliance | ASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC |
| Temperature Range | –95 to 450 °C |
| Heating/Cooling Rates | Up to 10⁶ K/s (heating), up to 10⁵ K/s (cooling) |
| Sensor Response Time | < 1 ms |
| Sample Mass Range | 1–500 ng |
| Compliance | ISO 11357, ASTM E794, ASTM E1269, USP <1151>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP82HT / FP84HT |
| Temperature Range | –60 to 375 °C |
| Temperature Repeatability | ±0.2 °C |
| Optical Field of View | Ø2.5 mm (FP82HT), Ø2.0 mm (FP84HT) |
| DSC Sensor | Au–Ni thermopile, 5 thermocouple pairs |
| Calorimetric Sensitivity | 13 mV/mW |
| Sample Environment | Sealed furnace chamber with inert gas compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC 2+ |
| Temperature Range | RT to 500 °C / 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Pressure Range | 0–10 MPa |
| Gas Flow Control | External pressure & mass flow controller supported |
| Atmosphere Compatibility | Inert, oxidizing, reducing, reactive (e.g., N₂, O₂, H₂, CO₂, C₂H₄, CH₃Br), with safety restrictions for combustible/toxic gases |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC1 |
| Temperature Range | 22–500 °C (optional to 700 °C) |
| Heating/Cooling Rate | 0.1–50 °C/min |
| Pressure Range | 0–10 MPa |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Sensor Type | FRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS84 |
| Temperature Range | RT to 375 °C (optional cooling to –90 °C) |
| Heating/Cooling Rate | 0.1–20 K/min |
| Light Aperture | 2 mm |
| Sensor Type | DSC ceramic sensor with 56 thermocouple pairs |
| Sample Carriers | Glass slides, top cover glass, aluminum/glass/sapphire crucibles |
| Crucible Dimensions | Ø6 mm / 40 µL |
| Display | 7″ touch-sensitive VGA color screen |
| Supported Languages | English, German, French, Spanish, Chinese, Japanese, Korean, Russian |
| User Shortcuts | 12 per user |
| Compliance | ASTM F766, EN ISO 3146 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TOPEM™ TMDSC |
| Category | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC 300 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.001 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (programmable) |
| Gas Flow Rate | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (custom voltage available) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | DSC100A |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Control Interface | USB 2.0 |
| Display | 7-inch 24-bit color TFT LCD touchscreen |
| Gas Flow Control | Digital mass flow controller with database logging |
| Calibration | Integrated standard reference materials and one-click temperature/enthalpy calibration |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC300 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automated switching (N₂, air, or custom gases) |
| Gas Flow Rate | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Thermal Control Modes | Programmable multi-step heating, isothermal hold, and cooling |
| Max Program Segments | 6 |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, baseline correction, peak integration, ASTM/ISO-compliant reporting templates |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | DSC300C |
| Sample Capacity | Single-sample |
| Temperature Range | −40 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Atmosphere Control | Dual-gas auto-switching (up to 300 mL/min, ≤5 MPa), plus dedicated purge gas inlet |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB 2.0 with auto-reconnect capability |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DSC300C |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | -40 to 600 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 to ±600 mW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| Atmosphere Control | Dual gas channels with automatic switching, plus dedicated purge gas inlet |
| flow rate | 0–300 mL/min |
| max pressure | ≤5 MPa |
| Temperature Program | Up to 6 segments (ramp/hold) |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Calibration Standards Included | Indium, tin, lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC300C |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −40 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.01 °C |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.01 °C |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC300L |
| Temperature Range | –170 °C to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0 mW to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | ±0.01 °C |
| Atmosphere Control | Dual-gas auto-switching (programmable), flow rate 0–300 mL/min, max pressure ≤5 MPa |
| Thermal Program | Up to 6-segment ramp/hold sequences |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Model | DT-3320C |
| Temperature Range | Ambient to 1500 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV |
| DTA Sensitivity | 0.01 µV |
| DTA Accuracy | 0.1 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Sensor Material | Pt-Rh Alloy |
| Interface | USB 2.0 Bidirectional |
| Display | 7-inch 24-bit Color LCD Touchscreen |
| Furnace Design | Top-Lifting Lid Configuration |
| Atmosphere Control | Programmable Internal Gas Switching |
| Power Supply | AC 220 V, 50 Hz (customizable) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DTA-3320A |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0–±2000 µV (expandable) |
| DTA Sensitivity | 0.01 µV |
| Baseline Adjustment | Adjustable slope and intercept |
| Calibration | Integrated standard reference materials with one-click temperature calibration |
| Control System | ARM-based embedded controller |
| Interface | USB 2.0 bidirectional communication |
| Display | 7-inch 24-bit color LCD touchscreen |
| Furnace Design | Top-opening vertical furnace architecture |
| Atmosphere Control | Programmable internal gas switching (N₂, Ar, air, O₂) |
| Power Supply | AC 220 V, 50 Hz (custom voltage/frequency available) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-DSC1000 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 1050 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas inlet |
| Gas Flow Range | 0–300 mL/min |
| Max Gas Pressure | ≤1 MPa |
| Control Method | PID-based automated temperature programming |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Display | 7-inch industrial-grade LCD touchscreen |
| Calibration Standards Included | Indium and Tin reference materials |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | DSC |
| Model | DZ-DSC100A |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Display | 7-inch 24-bit color LCD touchscreen |
| Gas Flow Control | Digital mass flow controller with database logging |
| Communication Interface | USB 2.0 bidirectional |
| Calibration | Integrated standard reference materials with one-click temperature and enthalpy calibration |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DZ-DSC100A |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZ-DSC100A |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Control Mode | Fully Programmable Auto-Control |
| Atmosphere Control | Automated Gas Switching (N₂, Air, O₂) |
| Display | 7-inch 24-bit LCD Touchscreen |
| Interface | Standard USB 2.0 |
| Calibration | Certified Reference Materials Included |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DZ-DSC100A |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Intelligent PID |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Sensor Material | Corrosion-Resistant Alloy |
| Gas Flow Control | Digital Mass Flow Meter |
| Interface | USB 2.0 Bidirectional Communication |
| Display | 7-inch 24-bit Color TFT Touchscreen |
| Calibration | Integrated Standard Reference Materials with One-Touch Temperature & Enthalpy Calibration |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-DSC100A |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.01 °C |
| Temperature Stability (Drift) | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0 to ±600 mW |
| DSC Noise Level | 0.01 μW |
| DSC Resolution | 0.01 μW |
| DSC Sensitivity | 0.01 mW |
| Control Method | Full-program PID-based auto-control with isothermal, ramp, and hold segments |
| Atmosphere Management | Dual-gas (N₂/O₂) automatic switching with digital mass flow control |
| Data Interface | USB 2.0 bidirectional communication |
| Display | 7-inch 24-bit color capacitive touchscreen LCD |
| Calibration | Pre-loaded certified reference materials (e.g., Indium, Zinc) with one-click thermal and enthalpy calibration |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.001 °C |
| Temperature Stability | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automatic switching (N₂, air, or inert gas), flow rate 0–300 mL/min (customizable), max pressure ≤5 MPa |
| Thermal Program | Up to six segments (heating/holding/cooling), fully programmable |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB |
| Calibration Standards Included | Indium, tin, lead |
| Power Supply | AC 220 V / 50 Hz (optional customization) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.001 °C |
| Gas Flow Control | Dual-channel automated switching, 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |