Differential Scanning Calorimeter
Filter
Showing 181–207 of 207 results
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | MICRO DSC7 |
| Temperature Range | −45 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Sample Cell Volume | 450 µL (intermittent mode) |
| Baseline Noise (RMS) | 0.4 µW |
| Minimum Detectable Heat Flow | 0.002 µW |
| Maximum Controllable Pressure | 1000 bar |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sensys DSC High-Pressure Calvet Microcalorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Pressure | 500 bar at 600 °C |
| Pressure Monitoring Limit | 400 bar at 600 °C |
| DSC Sample Volume | up to 320 μL |
| DSC Detection Limit | 5 μW |
| DSC Resolution | 0.4 μW |
| TGA Max Sample Mass | 35 g |
| TGA Resolution | 0.03 μg |
| Gas Lines | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Auto-sampler Capacity | 48 positions |
| Software | Calisto v5.x with Cp measurement module |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | –120 to 830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Mass Range | 3000 mg |
| Vacuum Level | <10⁻¹ mbar |
| TG Resolution | 0.002 µg |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static/Dynamic, Vacuum, Corrosive (e.g., H₂S, NH₃), Humidified Steam |
| Gas Control | Integrated 3-channel mass flow controller (2 carrier + 1 reactive gas), programmable mixing ratio (1:99 to 50:50) |
| TG Baseline Drift | <10 µg over full scan |
| TG Baseline Repeatability | ±1 µg |
| Evolved Gas Analysis Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 48-position ASC |
| Thermal Stability | ±0.001 to ±0.00001 °C (isothermal) |
| Sample Chamber Volume | 320 µL |
| Sensor Architecture | Calvet-type 3D thermopile sensor |
| Software | Calisto v6.x (21 CFR Part 11 compliant, GLP/GMP audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | -120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Sample Cell Pressure | 500 bar (at 600 °C) |
| Pressure Monitoring Range | Up to 400 bar (at 600 °C) |
| DSC Detection Limit | 5 µW |
| DSC Resolution | 0.4 µW |
| Sample Volume Capacity | 250 µL (up to 320 µL with extended cell) |
| TG Compatibility | Yes (up to 35 g sample, 0.03 µg resolution) |
| Atmosphere Options | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam, mixed gases (1–99% ratio) |
| Autosampler | 48-position |
| Software | Calisto v5.x (GLP-compliant, audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | Beijing, China (jointly developed by Chinese, French & Swiss teams) |
| Model | Setline DSC |
| Temperature Range | −170 to 700 °C |
| Programmable Heating/Cooling Rate | 0.01–100 °C/min |
| Temperature Accuracy | ±0.1 °C (vs. standard metals) |
| Temperature Precision | ±0.05 °C |
| DSC Signal Range | ±6000 mW |
| Heat Flow Resolution | 0.1 µW |
| Temperature Stability | ±0.1 °C (standard metal) |
| Sample Capacity | Single-position |
| Cooling Options | Manual/auto liquid nitrogen (−170 to 400 °C), He/Ar/dry air gas-cooling (−70 to 400 °C) |
| Gas Control | Dual-channel programmable gas switching |
| Software | Calisto 2.0 (data acquisition & processing with audit trail, user permissions, macro automation, Cp calculation) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under French R&D supervision) |
| Model | Setline DSC+ |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Heat Flow Resolution | 0.1 µW |
| Heat Flow Range | ±6000 mW |
| Calorimetric Accuracy | ±0.8% (vs. standard metals) |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual independent gas flow channels with software-programmed auto-switching |
| Sensor Type | Flat-plate NiCr–Constantan thermopile |
| Cooling Options | Manual/automated LN₂ (−170 °C to 400 °C), He gas cryo-cooling (−70 °C to 200 °C), dry air/N₂/Ar (−50 °C to 400 °C) |
| Crucible Options | Al₂O₃, Al (30 & 100 µL), Incoloy high-pressure (30 µL, up to 500 bar at 600 °C), 316L stainless steel (optional) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | uSC |
| Temperature Range | -40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–1.2 K/min |
| Calorimetric Channels | 4 (2 sample + 2 reference) |
| Sample Cell Volume | 850 µL |
| Baseline Noise | 0.2 µW RMS |
| Sensitivity (Joule effect at 30 °C) | 100 µV/mW |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% RMS |
| DSC Resolution | 0.02 µW / 0.002 µW |
| Pressure Range (measurable & controllable) | 400 bar (5800 psi) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (assembled with French-imported core components) |
| Model | Setline-dsc |
| Temperature Range | –170 to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified metal standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-L2 |
| Sample Capacity | Multi-sample simultaneous measurement |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −100 °C to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, dynamic cooling, isothermal hold |
| Temperature Accuracy | ±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1) |
| Baseline Stability | <0.5 µW over 30 min at 50 °C |
| Sensor Resolution | 0.01 µW |
| Temperature Sensing | Dual independent platinum RTD sensors (furnace + sample) |
| Control Algorithm | Adaptive dynamic PID with FTC/STC dual-mode selection |
| Data Acquisition | 1–10 Hz user-selectable sampling rate |
| Communication Interface | USB 2.0 with auto-reconnect protocol |
| Atmosphere Control | Dual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves |
| Calibration Standards | Indium, Zinc, Tin, and Sapphire (per ISO 11357-2) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Affinity ITC / ITC Auto |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 190 µL (low-volume) |
| Sample Throughput | Multi-sample via integrated 96-well autosampler |
| Temperature Control | Active solid-state heating/cooling with ±0.01 °C stability |
| Automation Level | Fully automated titration, injection, cleaning, and cell positioning |
| Compliance | Designed for GLP/GMP environments |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| Temperature Precision | ±0.01 °C |
| DSC Heat Flow Range | ±500 mW |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 250 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Precision | ±0.008 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Capacity | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without liquid nitrogen) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 2500 |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | –180 °C to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Throughput | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without LN₂) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25P |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –130 °C to 550 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Pressure Range | 1 Pa to 7 MPa (0.0001–1,000 psi) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC2500 |
| Temperature Range | –180 to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Baseline Flatness (–50 to 300 °C) | <5 μW |
| Baseline Repeatability (–50 to 300 °C) | <10 μW |
| Enthalpy Accuracy | ±0.04 % |
| Heating/Cooling Rate | 0.1–100 K/min |
| Modulated DSC | Standard |
| Tzero® Technology | Advanced (T4P) |
| Direct Cp Measurement | Supported |
| User-Replaceable Furnace | Yes |
| 54-Position Autosampler | Standard |
| Dual-Gas Delivery Module | Standard |
| Color Touchscreen Interface | Standard |
| Optical Accessory Compatibility | Optional |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery X3 DSC |
| Sample Capacity | Up to 3 simultaneous samples |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | –180 °C to 550 °C |
| Temperature Accuracy | ±0.025 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Cell Volume | < 200 µL (capillary-based) |
| Pressure Control | Integrated solid-state linear actuator with ±0.1 psi regulation |
| Automation | Optional DSC Auto autosampler (HPLC-grade precision) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RS-DSC |
| Sample Throughput | Multi-sample simultaneous measurement |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | 20–100 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM IV |
| Simultaneous Sample Capacity | Multiple |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM 48 |
| Simultaneous Sample Capacity | Up to 48 |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Instrument Type | Isothermal Titration & Reaction Microcalorimeter |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CRY-2A / CRY-1A |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DSC30 |
| Temperature Range | Ambient to 750 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Stability | < ±0.1 µW over 30 min |
| Atmosphere Control | Dual-channel, 0–200 mL/min (0.1 mL/min resolution) |
| Cooling Speed | 550 °C → −40 °C in ≤35 min |
| Temperature Control Precision | < ±0.03 °C (isothermal), Linearity Error < 0.1 °C @ 10 °C/min |
| Sensor | Integrated NiCr/NiSi thermopile with symmetrical sample-stage electrodes |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Temperature Range | RT to 700 °C |
| Heating Rate | 0.05–200 °C/min |
| Baseline Stability | ≤100 µW (100–300 °C, uncorrected) |
| Baseline Repeatability | ≤40 µW |
| Heat Flow Noise | <8 µW (peak-to-peak) |
| Enthalpy Accuracy | ±0.8% (In) |
| Enthalpy Precision | ±0.08% (In) |
| Phase Transition Temperature Accuracy | ±0.1 °C (In) |
| Phase Transition Temperature Precision | ±0.02 °C (In) |
| Indium Peak Height / FWHM | ≥20.0 mW/K |
| Sampling Frequency | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel, inert/oxidizing, static/dynamic, 0–300 mL/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Sample Capacity | Single-sample |
| Temperature Range | –90 °C to 550 °C (with optional imported high-performance mechanical cryocooler) |
| Cooling Method | Mechanical refrigeration + air cooling |
| Heating/Cooling Rate | 0.05–200 °C/min (heating), 0.1–100 °C/min (cooling) |
| Temperature Accuracy | ±0.1 °C (In), Precision: ±0.02 °C (In) |
| Baseline Drift | ≤100 µW (–50–300 °C, no baseline correction) |
| Baseline Repeatability | ≤40 µW |
| Peak Noise (Heat Flow) | <8 µW |
| Enthalpy Accuracy | ±0.8% (In), Precision: ±0.08% (In) |
| Indium Peak Height/FWHM | ≥20.0 mW/K |
| Data Acquisition Rate | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel mass-flow-controlled atmosphere (inert/oxidizing, static/dynamic, 0–300 mL/min) |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Model | DTA-1350 |
| Temperature Range | RT to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DTA Signal Range | 0–±2000 µV |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Control Method | PID-based Programmable Temperature Control |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Sensor Material | Corrosion- and oxidation-resistant alloy |
| Atmosphere Control | Automated internal gas switching |
| Calibration Standard | Certified Sn reference material included |
| Compliance | ASTM E794, ISO 11357-1, GB/T 19466.1–2004 |
| Brand | Jiubin Instruments |
|---|---|
| Model | DSC-300L |
| Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C (extended capability to 1050 °C per specification) |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| DSC Dynamic Range | ±800 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas line |
| Gas Flow Range | 0–300 mL/min |
| Gas Pressure Limit | ≤1 MPa |
| Display | 7-inch industrial-grade capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect protocol |
| Compliance | GB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999 |