Differential Scanning Calorimeter
Filter
Showing 61–90 of 207 results
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-750L |
| Temperature Range | −150 to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| DSC Sensitivity | 0.001 mW |
| DSC Dynamic Range | ±500 mW |
| Temperature Resolution | 0.01 °C |
| Atmosphere Control | Dual-gas mass flow controller (N₂/O₂) |
| Interface | USB 2.0 with auto-reconnect |
| Display | 7-inch 24-bit color LED touchscreen |
| Calibration | Pre-loaded standard reference materials (In, Sn, Zn, KCl), one-click temperature calibration |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1050 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 mW |
| Temperature Repeatability | ±0.1 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Atmosphere Control | Dual-gas (N₂/O₂) with digital mass flow meters (0–200 mL/min) |
| Power Supply | 220 V, 50 Hz |
| Operating Environment | 20–25 °C, 55–75% RH |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Temperature Range | Ambient to 800 °C (air-cooled) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 K/min |
| Heat Flow Resolution | 0.1 μW |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 °C/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Resolution | 0.01 °C |
| DSC Noise Level | 0.001 mW |
| DSC Sensitivity & Resolution | 0.01 mW |
| Atmosphere Control | Automated Gas Switching (N₂, O₂, Air) |
| Gas Flow Rate | 0–200 mL/min |
| Gas Pressure | 0.2 MPa |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration | Integrated reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 600 W |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Temperature Range | Ambient to 800 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 K/min |
| Heat Flow Resolution | 0.1 μW |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800L |
| Instrument Type | DSC |
| Temperature Range | Ambient to 800 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Heat Flow Range | ±200 mW |
| Sample Capacity | Single-sample configuration |
| Detection Sensitivity | 0.1 μW |
| Brand | Jiubin |
|---|---|
| Model | JB-DSC-500B |
| Origin | Shanghai, China |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 °C/min (heating), 0.1–10 °C/min (cooling) |
| DSC Sensitivity | 0.1 µW |
| DSC Range | ±500 mW |
| Temperature Resolution | 0.01 °C |
| DSC Accuracy | ±1% |
| Atmosphere Control | Dual-gas (N₂/O₂) mass flow control with automatic switching |
| Interface | USB 2.0 |
| Display | 7-inch 24-bit LED touch screen |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-500B |
| Sample Capacity | 1 |
| Instrument Type | DSC |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | ±600 mW |
| Compliance | GB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-500B |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Single-sample configuration |
| Compliance | Designed for ASTM E794, ISO 11357, and USP <1163> thermal analysis workflows |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-600 |
| Sample Capacity | 1 |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sensitivity | 0.01 mW |
| Noise Level | 0.001 mW |
| Thermal Resolution | 0.001 mW |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Gas Flow Control | 0–200 mL/min (0.2 MPa max) |
| Interface | USB |
| Display | 7-inch 24-bit color touchscreen LCD |
| Power Supply | AC 220 V, 50 Hz, 600 W |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JB-DSC-600 |
| Price Range | USD 7,000–14,000 (FOB) |
| Sample Capacity | Single-position |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Sensitivity | 0.01 mW |
| DSC Noise Level | 0.001 mW |
| DSC Resolution | 0.001 mW |
| DSC Accuracy | 0.01 mW |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Gas Flow Control | 0–200 mL/min |
| Gas Pressure Rating | 0.2 MPa |
| Display | 7-inch 24-bit LCD touchscreen |
| Data Interface | Standard USB |
| Calibration | Integrated with certified reference materials and one-click thermal & enthalpy calibration |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 600 W |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DSC-800 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 800 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Display | 7-inch 24-bit color TFT touchscreen |
| Control Core | ARM Cortex-M3 microcontroller |
| Communication | USB 2.0 bidirectional interface |
| Sensor Material | High-stability alloy thermopile |
| Furnace Design | Fully enclosed metallic furnace housing |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-DTA-1150 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 °C/min |
| DTA Signal Range | 0 to ±2000 μV |
| DTA Sensitivity | 0.01 μV |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Furnace Type | Top-opening dual-wound Fe-Cr-Al heating element (1 kW) |
| Atmosphere Control | Automated internal gas switching |
| Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Calibration | Built-in reference materials with one-click temperature calibration |
| Baseline Adjustment | Adjustable slope and intercept |
| Power Supply | AC 220 V, 50 Hz |
| Brand | JWGB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 600 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −150 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Temperature Precision | ±0.1 °C |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | DSC600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | up to 130 °C/min |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DSC L64 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 to 160 °C (standard) |
| Heating/Cooling Rate | 0.001–10 K/min (standard) |
| Temperature Accuracy | ±100 µ°C |
| Sensitivity | 550 µV/mW (25 °C) |
| Sample Volume | 5–100 µL (standard) |
| Sensor Technology | Patented high-sensitivity thermopile-based sensor with direct sample temperature measurement and Joule-effect calibration |
| Sample Holder | Removable, hermetically sealed crucible |
| Dimensions (W×D×H) | 900 × 700 × 500 mm (standard) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 1 (Chip-DSC L66 Basic) |
| Instrument Type | DSC |
| Temperature Range | RT to 450 °C (no active cooling unit) |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.2 K |
| DSC Signal Range | ±2.5–±1000 mW |
| Temperature Repeatability | ±0.02 K |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration | Supplied with certified reference materials |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 10 (Chip-DSC L66 Advanced) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 to 600 °C (with optional quench cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–300 K/min (up to 500 K/min ballistic cooling from 400 °C) |
| DSC Signal Range | ±2.5 to ±1000 mW |
| Thermal Resolution | 0.03 µW |
| Digital Resolution | 16.8 million data points per trace |
| Atmosphere Options | Inert or oxidative (static/dynamic) |
| Calibration Frequency | Recommended every 6 months |
| Compliance | ASTM E794, ISO 11357-1 to -7, USP <1163>, GLP-ready audit trail support |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | Chip-DSC 100 (Chip-DSC L66 Ultimate) |
| Instrument Type | DSC |
| Temperature Range | −150 to 600 °C (Peltier, closed-loop internal cooler, or liquid nitrogen cooling) |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.02 K |
| Heating/Cooling Rate | 0.001–1000 K/min |
| DSC Signal Range | ±2.5–±1000 mW |
| Heat Flow Resolution | 0.03 µW |
| Atmosphere Control | Inert or oxidative (static/dynamic) |
| Recommended Calibration Interval | Every 6 months |
| Digital Imaging Resolution | 1680 megapixels (optical accessories only) |
| Power Consumption | Up to 80% lower than conventional DSC systems |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DSC L62 |
| Instrument Type | DSC |
| Temperature Range | −150 °C to 1750 °C |
| Heating/Cooling Rate | 0.001–50 K/min |
| DSC Signal Range | ±2.5 mW to ±250 mW |
| Sensor Types | DSC, DTA, DSC–Cp |
| Thermocouple Options | E, K, S, B |
| Vacuum Capability | down to 10⁻⁵ mbar |
| Atmosphere Control | inert, oxidizing, reducing (static/dynamic) |
| Modulated Temperature Function | Yes |
| Interface | USB |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Instrument Type | Differential Scanning Calorimeter |
| Model | DSC L63 |
| Temperature Range | −170 °C to 750 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Temperature Accuracy | ±0.1 K |
| DSC Signal Range | ±750 mW |
| Sample Capacity | Up to 96 positions (with optional autosampler) |
| Data Acquisition Rate | 100 Hz |
| Enthalpy Accuracy | <1% (verified with In, Zn standards) |
| Sensor Type | Ceramic/metal hybrid high-resolution sensor |
| Gas Control | Optional MFC (3 gases) or integrated MFC |
| 炉 Body & Crucible Interchangeability | Yes |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP-ready |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | DTA L61 |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | −150 °C to 2400 °C (configurable: −150–500 °C, −150–1000 °C, RT–1400 °C, RT–1500 °C, RT–1600 °C, RT–1750 °C, RT–2000 °C, RT–2400 °C) |
| Heating/Cooling Rate | 0.001–50 K/min |
| Vacuum Capability | down to 1×10⁻⁵ mbar |
| Sensor Types | E-, K-, S-, B-, and C-type thermocouples |
| Measurement Principle | Heat-Flux DTA |
| Atmosphere Control | Oxidizing, reducing, inert (static/dynamic) |
| Optional Coupling | Mass Spectrometry (MS), Fourier Transform Infrared Spectroscopy (FTIR) |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroCal PEAQ-DSC Automated |
| Sample Throughput | Up to 50 samples per unattended run |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Sample Format | Standard 96-well microplate compatibility |
| Regulatory Compliance | Designed for 21 CFR Part 11 and EU GMP Annex 11 compliance support |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-DSC |
| Sample Throughput | Multiple samples per run (manual loading) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 1 |
| Temperature Range | –150 °C to 700 °C |
| Sensor Configuration | 56- or 120-pair star-arranged thermocouples |
| Optional Modules | UV-DSC, HP-DSC (up to 100 bar / down to 10 mbar), DSC-Microscopy System |
| Autosampler Capacity | Up to 34 samples |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3+ |
| Temperature Range | -150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min |
| Sensor Options | FRS 6+ (56 thermocouples) or HSS 9+ (120 thermocouples) |
| TAWN Resolution (FRS/HSS) | 0.12/0.2 °C |
| TAWN Sensitivity (FRS/HSS) | 11.9/56 µW/°C |
| Indium Response Ratio (FRS) | >155 mW/°C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |