Environmental Monitoring Instruments
Filter
Showing 3361–3390 of 9112 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-74 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Measurement Principle | Glass Electrode (pH), Redox Electrode (ORP), Ion-Selective Electrode (ISE), AC Two-Electrode Conductometry (Conductivity) |
| Display | Capacitive Touchscreen |
| Data Storage | 2000 Sets |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVII, ChP |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Weight | 0.7 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-74 |
| Instrument Type | Benchtop Multi-Parameter Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Display | Dual-channel capacitive touchscreen |
| Data Storage | 2000 measurements |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC adapter (100–240 V, 50/60 Hz), ~9.8 VA |
| Weight | ~700 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-74BW |
| Measurement Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Display | Dual-channel capacitive touchscreen |
| Data Storage | 999 measurement records |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVI, CP 2020 |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-74BW |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Display | Dual-channel capacitive touchscreen |
| Data Storage | 999 measurement records |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, ChP |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-74BW |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS |
| Display | Dual-channel capacitive touchscreen |
| Data Storage | 999 measurement records |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVI, CP 2020 |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC adapter (100–240 V, 50/60 Hz), ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FIA-510 |
| Instrument Type | Flue Gas Analyzer for Total Hydrocarbons (THC) |
| Measurement Principle | Sub-atmospheric Hydrogen Flame Ionization Detection (FID) |
| THC Range | 0–50 ppmC (low-sensitivity mode) to 0–30,000 ppmC (high-range mode) |
| Accuracy | ±3% of reading |
| Repeatability | ±0.5% FS (standard range), ±1% FS (high-sensitivity range) |
| Drift | ±1% FS/day (standard range), ±2% FS/day (high-sensitivity range) |
| Response Time (T90) | ≤10 s |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Dimensions (W×D×H) | 430 × 550 × 132 mm |
| Weight | 20 kg |
| Dynamic Range | 4-step programmable range (standard) |
| optional 20 | 1 extended ratio |
| Calibration | Single-touch zero/span adjustment |
| Self-Diagnosis | Integrated CPU with real-time status monitoring |
| Compliance | Designed for continuous emission monitoring (CEM) in accordance with ISO 8712, JIS B 7982, and EPA Method 25A equivalents |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FIA-510 |
| Measurement Principle | Partially Pressurized Hydrogen Flame Ionization Detection (FID) |
| Measurand | Total Hydrocarbons (THC) as ppmC |
| Range | 0–50 ppmC (min) to 0–30,000 ppmC (max) |
| Repeatability | ±0.5 %FS (standard range), ±1.0 %FS (high-sensitivity range) |
| Drift | ±1.0 %FS/day (standard range), ±2.0 %FS/day (high-sensitivity range) |
| Response Time (T90) | 10 s |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Dimensions (W×D×H) | 430 × 550 × 132 mm |
| Weight | 20 kg |
| Linearity | ≤±1.0 %FS |
| Dynamic Range | 4-step standard (10:1), optional 20:1 |
| Calibration | Single-touch zero/span adjustment |
| Self-Diagnostic Function | Yes |
| Housing | 19-inch rack-mountable or benchtop configuration |
| Compliance | Designed for continuous emissions monitoring (CEM) in accordance with ISO 8712, JIS B 7982, and applicable EPA Method 25A guidelines |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FIA-510 |
| Measurement Principle | Partially depressurized hydrogen flame ionization detection (FID) |
| Measurand | Total Hydrocarbons (THC) as ppmC |
| Range | 0–50 ppmC (min) to 0–30,000 ppmC (max) |
| Repeatability | ±0.5 %FS (±1 %FS in high-sensitivity range) |
| Drift | ±1 %FS/day (±2 %FS/day in high-sensitivity range) |
| Response Time (T90) | 10 s |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Dimensions (W×D×H) | 430 × 550 × 132 mm |
| Weight | 20 kg |
| Dynamic Range | 4-step standard (10:1), optional 20:1 |
| Display & Control | Built-in CPU, digital concentration readout, one-touch zero/span calibration, self-diagnostic functions |
| Mounting | Benchtop or 19-inch rack-mountable |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Output Signals | DC 0–1 V, RS-232C |
| Data Storage | CF card |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% of Full Scale (FS) |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Output Signals | DC 0–1 V analog, RS-232C serial interface |
| Data Storage | CompactFlash (CF) card |
| Safety Features | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Data Storage | CompactFlash (CF) card |
| Safety Feature | Automatic H₂ shutoff and alarm upon flame-out |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Output Signals | DC 0–1 V, RS-232C |
| Data Storage | CompactFlash (CF) card |
| Safety Features | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 s |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Data Storage | CF card |
| Safety Features | Automatic H₂ shutoff and alarm upon flame extinction |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable |
| Detection Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Data Storage | CompactFlash (CF) card |
| Safety Feature | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260 (W) × 260 (H) × 510 (D) mm |
| Data Storage | CF card |
| Safety Feature | Automatic H₂ shutoff and alarm upon flame-out |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 seconds |
| Drift | ±1.0% FS / 8 hours |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 hour |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Data Storage | CompactFlash (CF) card |
| Safety Features | Automatic H₂ shutoff and alarm upon flame extinction |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 s |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260 W × 260 H × 510 D mm |
| Output Signals | DC 0–1 V, RS-232C |
| Data Storage | CompactFlash (CF) card |
| Safety Feature | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | <2.0 s |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | <85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Output Signals | DC 0–1 V, RS-232C |
| Data Storage | CompactFlash (CF) card |
| Safety Features | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 s |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Output Signals | DC 0–1 V, RS-232C |
| Data Storage | CompactFlash (CF) card |
| Safety Features | Automatic H₂ shutoff and alarm upon flame-out |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | FV-250 |
| Instrument Type | Portable VOC Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 ppmC |
| Resolution | ±1.0% FS |
| Accuracy | ±1.0% FS |
| Response Time (T90) | < 2.0 s |
| Drift | ±1.0% FS / 8 h |
| Linearity | ±1.0% FS |
| Sampling Flow Rate | ~600 mL/min |
| Warm-up Time | ~1 h |
| Operating Temperature | 5–35 °C |
| Operating Humidity | < 85% RH |
| Output Signals | DC 0–1 V, RS-232C |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 50 VA |
| Dimensions | 260(W) × 260(H) × 510(D) mm |
| Data Storage | CF card |
| Safety Feature | Automatic H₂ shutoff and alarm upon flameout |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GA-370 |
| Measurement Principle | Dual-Beam Alternating Flow Modulated NDIR |
| Response Time | ≤ 180 s |
| Detection Limit | 10 ppb (for CO, CO₂, CH₄) |
| Gas Compatibility | N₂, O₂, He, Ar, H₂, Air |
| Compliance Notes | Designed for use in ISO/IEC 17025-accredited labs and GMP-aligned gas production facilities |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | H-519 |
| Instrument Type | Portable Oil Content Analyzer |
| Measurement Principle | Infrared Absorption (at 3.4 µm) |
| Measurement Range | 0–200 mg/L |
| Detection Limit | < 0.2 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 1 test per 2 minutes (0.5 Hz equivalent sampling rate) |
| Compliance Context | Designed for use with OCMA-505H/555H analyzers per ASTM D7678, ISO 9377-2, and EPA Method 1664B workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3200044462 |
| Application | Dedicated extraction reagent for OCMA-series oil analyzers |
| Compatibility | Designed for use with SR-305 solvent recovery system |
| Regulatory Context | Compliant with ISO 9377-2 (petroleum hydrocarbons in water) and EPA Method 1664A (n-hexane extractable material) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HD-200 |
| Protection Rating | IP65 |
| Measurement Principle | Clark-type Polarographic Membrane Sensor |
| DO Range | 0–20 mg/L (Resolution: 0.01 mg/L) |
| Saturation Range | 0–200% (Resolution: 1%) |
| Temperature Range | 0–50 °C (Resolution: 0.1 °C) |
| Repeatability | ±0.5% FS (DO), ±0.5 °C (Temp) |
| Linearity | ±0.5% FS (DO), ±0.5 °C (Temp) |
| Output | Three isolated 4–20 mA analog channels (max load: 900 Ω), three SPDT relay outputs, one dry-contact input, RS-485 Modbus RTU interface |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤15 VA |
| Operating Ambient | −20 to +55 °C |
| Enclosure Material | Anodized Aluminum |
| Weight | ~4.5 kg |
| Compliant | CE, FCC, RoHS, WEEE |
| Compatible Probes | DO-1100 (integrated Pt1000 temperature sensor), Electrodes: 5505, 5510 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HD-300 |
| Measurement Principle | Clark-type Polarographic Membrane Sensor |
| DO Range | 0–20 mg/L (resolution: 0.01 mg/L) |
| Saturation Range | 0–200% (resolution: 1%) |
| Temperature Range | 0–50 °C (resolution: 0.1 °C) |
| Repeatability | ±0.5% FS (DO), ±0.5 °C (temperature) |
| Linearity | ±0.5% FS (DO), ±0.5 °C (temperature) |
| Output | Isolated 4–20 mA DC (max. load: 600 Ω) |
| Digital Interface | RS-485 (2-wire, input/output isolated) |
| Power Supply | 24 V DC (21–32 V DC operating range), max. 0.6 W |
| Enclosure Rating | IP65 |
| Ambient Operating Temperature | −20 to +60 °C |
| Housing Material | Aluminum alloy |
| Mounting | Wall or 50A pipe column |
| Compatible Probes | DO-1100 (integrated Pt1000 temperature sensor) |
| Compliant Standards | CE, FCC, RoHS, WEEE |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HD-480 (Electrochemical Membrane-Type), HD-200FL (Optical Fluorescence-Based) |
| Measurement Principle | Clark-type membrane electrode (HD-480) |
| Output Signal | 4–20 mA, RS-485 (Modbus RTU) |
| Operating Temperature | 0–50 °C |
| IP Rating | IP66/IP67 |
| Power Supply | 12–24 VDC |
| Sensor Cable Length | Standard 5 m (extendable up to 30 m) |
| Compliance | CE, RoHS, ISO 5814:2012 (DO measurement), ASTM D888-22 (dissolved oxygen in water) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HD-480 |
| Measurement Principle | Galvanic Cell (Electrochemical) |
| DO Range | 0–20 mg/L (resolution: 0.01 mg/L) |
| Saturation Range | 0–200% (resolution: 1%) |
| Temperature Range | 0–40 °C (resolution: 0.1 °C) |
| Repeatability | ±0.5% FS (max) |
| Linearity | ±0.5% FS (max) |
| Output | Isolated 4–20 mA DC (max load: 900 Ω) |
| Relay Outputs | 2 × SPDT (240 V AC / 30 V DC, 3 A) |
| Calibration Options | Air saturation, saturated aqueous solution, salinity (0.0–5.0%), dual-point temperature compensation |
| Sensor Compatibility | DP-1100 probe with built-in Pt1000 thermistor |
| Power Supply | 90–264 V AC, 50/60 Hz |
| Max Power Consumption | 10 W |
| Operating Ambient | −5 to +45 °C |
| Compliance | CE, FCC, RoHS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HE-200C |
| Enclosure Rating | IP65 |
| Power Supply | 90–264 V AC, 50/60 Hz |
| Output | Three isolated 4–20 mA analog outputs (configurable per parameter) |
| Relay Outputs | Three SPDT dry-contact relays (R1–R3, user-assignable for high/low alarms, USP qualification, or fault indication) |
| Communication | RS-485 (2-wire, galvanically isolated input/output circuitry) |
| Temperature Compensation | Pt1000 sensor (0 °C reference), 0–100 °C range |
| Measurement Parameters | Conductivity (0.000 µS/cm to 200.0 mS/cm, selectable cell constant: 0.01, 0.1, or 1.0 cm⁻¹), TDS (0.00–2000 mg/L, user-defined conversion factor 0.30–1.00), and temperature (0–100 °C, ±0.1 °C accuracy at reference point) |
| Accuracy | Conductivity ±0.5% FS (max), TDS ±1.5% FS (max), temperature ±0.5 °C linearity error |
| Repeatability | Conductivity ±0.5% FS (max), TDS ±1.5% FS (max) |
| Environmental Rating | Outdoor-rated aluminum housing, CE/FCC/WEEE/RoHS compliant |
| Mounting | Pole-mounted (50A pipe) or wall-mounted |
| Weight | ~4.5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HE-200H |
| Measurement Principle | Four-Electrode Conductivity |
| Range | 0.0–200.0 mS/cm (auto-ranging, dual-scale: 0.00–20.00 mS/cm & 0.0–200.0 mS/cm) |
| Temperature Compensation | 0–100 °C (Pt1000 sensor) |
| Accuracy | ±0.5% FS (0–20.00 mS/cm), ±1.0% FS (20.0–200.0 mS/cm) |
| Repeatability | ±0.1 °C (temperature), linearity ±0.5 °C |
| Enclosure Rating | IP65 |
| Compliance | CE, FCC, RoHS, WEEE |
| Output | Three isolated 4–20 mA analog outputs (max load 900 Ω), three SPDT relay contacts (R1/R2/failure), RS-485 Modbus RTU interface |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤15 W |
| Operating Ambient | −20 to +55 °C |
| Weight | ~4.5 kg |
| Housing Material | Anodized aluminum alloy |
| Mounting | Pole-mounted (50A pipe) or wall-mountable |
| Electrode Constant Options | 0.1 cm⁻¹ or 1.0 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HE-200R |
| Measurement Principle | Two-Electrode Conductivity Method (Inverse Calculation for Resistivity) |
| Resistivity Range | 0.000–2.000 MΩ·cm (with K=0.01/cm electrode), 0.00–20.00 kΩ·cm, 0.0–200.0 kΩ·cm |
| Temperature Range | 0–100 °C |
| Temperature Compensation | Pt1000 sensor (0 °C reference), 0–100 °C range |
| Accuracy (Resistivity) | ±0.01 MΩ·cm max (at reference temperature, standard units) |
| Accuracy (Temperature) | ±0.02 °C max |
| Repeatability (Resistivity) | ±0.1% FS |
| Linearity (Resistivity) | ±0.5% FS |
| Output | Isolated 4–20 mA (2 points), SPDT relay outputs (3 points), dry-contact input (1 point) |
| Communication | RS-485 (2-wire, input/output isolated) |
| Enclosure Rating | IP65 |
| Compliance | CE, FCC, RoHS, WEEE |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤15 VA |
| Operating Ambient | −20 to +55 °C |
| Weight | ~4.5 kg |
| Sensor Compatibility | ERF-series resistivity sensors (K=0.01 cm⁻¹) |
| Calibration | Electrode constant entry, single-point temperature calibration, atmospheric or saturated solution reference modes |
| Special Functions | Ultrapure water resistivity mode, trim adjustment, real-time self-diagnosis (electrode fault, analyzer error) |