| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GM200 / GM200e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| TOC Range | 0.000–30.000 mg/L |
| IC Range | 0.000–5.000 mg/L |
| Repeatability Error | ≤2% (per JB/T 20178–2017) |
| Max. Permissible Error | TC ±5%, IC ±4% (per JJG 821–2005) |
| Analysis Time | 2.5 min |
| Dimensions | 400 mm × 400 mm × 200 mm |
| Ingress Protection | IP65 |
| Data Integrity | Audit Trail Enabled |
| User Access Control | Four-Tier Password Authentication |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-ESAC100 |
| Pricing | Upon Request |
| Illumination Source | Shadow-Free White LED Light Source |
| Detection Method | High-Resolution Digital Camera + AI-Powered Image Recognition Algorithm |
| Interface | USB-A |
| Special Function | Auto-Dilution Mode Support |
| Identification Speed | <10 seconds per quantitative tray |
| Operating Ambient Temperature | 0–45 °C |
| Dimensions (W×D×H) | 380 × 243 × 364 mm |
| Weight | 12 kg |
| Power Supply | AC 220 V ±10% |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-F100 |
| Power Supply | AC 220 V / 50 Hz |
| Maximum Sample Volume | 0–9999 L |
| Filtration Material | 316L Stainless Steel + Titanium Alloy Filter Discs |
| Touchscreen Interface | 7-inch Foldable Color LCD |
| Concentration Flow Rate | 0–2.2 L/min (adjustable) |
| Filter Cartridge Actuation | One-Touch Electric Control |
| Rated Power | ≤200 W |
| Net Weight | 15 kg |
| Pressure Sensor Range | 0–2.0 MPa |
| Sterilization Methods | Chemical Disinfectant Rinse / Moist Heat Sterilization |
| Membrane Replacement Alert | Automatic Notification |
| Channel Scalability | Up to 8 Units in Parallel Configuration |
| Average Recovery Efficiency | >35% (Cryptosporidium oocysts & Giardia cysts, per EPA Method 1623.1/ISO 15553) |
| Workflow Customization | User-Defined SOP Sequencing, Adjustable Sample Volume Input, Real-Time Status Alerts & Emergency Stop Functionality |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-S100 |
| Price | Upon Request |
| Water Processing Capacity | 10 L per cycle |
| Pretreatment Time | ≤15 min |
| Touchscreen Interface | 7-inch foldable color LCD |
| Sample Loading | Motorized or manual |
| Power Consumption | ≤300 W |
| Unit Weight | 18 kg |
| Settling Timer Range | 0–99 h |
| Turbidity Sensor Range | 0–200 NTU |
| Pressure Sensor Range | 0–2.0 MPa |
| Stirring Speed Range | 0–1500 rpm |
| Disinfection Method | Integrated UV-C lamp (254 nm) |
| pH Sensor Range | 0–14 |
| Parallel Operation | Up to 8 units via master-slave configuration |
| Average Protozoan Recovery Efficiency | >35% (per ASTM D5421 / ISO 15553 validated methodology) |
| Workflow Customization | User-defined SOPs with real-time status alerts and auto-halt on anomaly detection |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HTY-GM2000 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.000–20.000 mg/L |
| Repeatability | ≤3% |
| Sample Volume Requirement | 12 mL per analysis |
| Analysis Time | ≤20 min per sample |
| Detection Limit | <10 µg/L |
| IC Range | 0.000–5.000 mg/L |
| Accuracy (Indicated Value Error) | ±5% |
| Injection Speed | 0.6 mL/min |
| Dimensions | 480 × 300 × 540 mm |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTY-UVB01 |
| UV Wavelengths | 254 nm (short-wave) & 366 nm (long-wave) |
| Lamp Voltage | 50 V ± 10 V |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (L×W×H) | 320 × 240 × 320 mm |
| Weight | 3.8 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Design Features | Integrated UV housing with magnetic sample door, dual-side access ports, UV-shielded operation |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | QYP Series Sterile Sampling Bottles |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SWS Series Sterile Water Sampling Bags |
| Pricing | Available Upon Request |
| Volume Options | 100 mL, 250 mL, 500 mL |
| Sterilization Method | Gamma Irradiation |
| Packaging | Individual Sterile Peel-Pouch |
| Membrane Structure | Triple-Layer Laminated Film (PET/AL/PE) |
| Closure | Integrated Single-Use Snap Lock Cap |
| Sodium Thiosulfate Option | Available (1.8 mg/bag, pre-loaded for chlorine neutralization) |
| Compliance | Meets ISO 19458:2006 (Water quality — Requirements for sterile sampling containers), USP <61> Microbial Enumeration Tests, and EPA Method 1603 (E. coli in water) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Enzyme-Substrate-Based Total Colony Count Detection Kit |
| Pricing | Available Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HTY-APM100 |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Sample Volume Range | 0.1–1.0 mL (recommended: 0.3 mL) |
| Measurable TOC Range | 0–1000 mg/L |
| Repeatability | ≤3% (at 50% of full scale, per JJG 821–2005) |
| Accuracy | TC ±5%, IC ±4% (at 20%, 50%, and 80% of full scale, per JJG 821–2005) |
| LOD | ≤0.1 mg/L (per HJ 501–2009) |
| LOQ | ≤0.5 mg/L (per HJ 501–2009) |
| Maximum Salt Tolerance | ≤90 g/L |
| Dimensions | 650 × 450 × 495 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Detection Range | 0.000–1000.0 µg/L |
| Repeatability | ≤2% (per JB/T 20178–2017) |
| Accuracy | ±5% (per JJG (Zhejiang) 98–2007) |
| Recommended Sample Conductivity | 0–5.1 µS/cm @ 25 °C |
| Analysis Time | 4 min |
| Sample Flow Rate | 0.5 mL/min |
| Dimensions | 400 × 300 × 300 mm |
| User Interface | Full-touchscreen LCD |
| Security | Multi-level password access control |
| Alarm Function | Audible alert upon exceeding user-defined TOC upper limit |
| Optional Accessory | Modular autosampler compatibility |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.500 mg/L |
| Accuracy | ±3% |
| Resolution | 1 ppb |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤±3% |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-DI1500-OL |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.000–1500.0 µg/L |
| Repeatability | ≤2% (per JB/T 20178–2017) |
| Accuracy | ±5% (per JJG (Zhejiang) 98–2007) |
| Recommended Sample Conductivity | 0–5.1 µS/cm @ 25 °C |
| Analysis Cycle Time | 4 minutes |
| Sample Flow Rate | 0.5 mL/min |
| Dimensions | 240 × 340 × 160 mm |
| Enclosure Rating | IP65 |
| Interface | RS485/Ethernet for multi-unit centralized control |
| Data Integrity Features | Electronic Signatures, Audit Trail, User Access Levels |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HTY-ESIC97 |
| Pricing | Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W × D × H) | 1320 × 835 × 1890 mm |
| Weight | ≤ 100 kg |
| Total Power Consumption | 5 kW |
| Operating Noise Level | ≤ 60 dB(A) |
| Target Microorganisms | Total Coliforms, Escherichia coli |
| Incubation Temperatures | 37 °C and 44.5 °C |
| Temperature Control Accuracy | ±0.4 °C |
| Quantification Plate Formats | 97-well and 51-well |
| Maximum Concurrent Plates | 100 |
| Integrated UV Observation Chamber | Yes |
| Data Integrity Features | Audit Trail, Electronic Signature, Role-Based Access Control (3-Tier), Automatic Archiving, LIMS Compatibility, Customizable Report Templates, Cloud/Network Reporting |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS01 |
| Pricing | Upon Request |
| Operating Voltage | 220 V ±10% |
| Preheat Time | <15 min |
| Ambient Operating Temperature | −10 °C to 50 °C |
| External Housing Temperature | <40 °C |
| Dimensions (W×D×H) | 390 × 300 × 270 mm |
| Weight | 19 kg |
| Noise Level | <50 dB(A) |
| Compatible With | 51-well and 97-well Quanti-Tray®-style trays |
| Includes | MPN lookup tables (51- and 97-well), silicone sealing gasket |
| Maintenance | Front-access service door for routine cleaning and component inspection |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS02 |
| Pricing | Upon Request |
| Weight | 15 kg |
| Power Consumption | 1 kW |
| Input Voltage | AC 220 V / 50 Hz |
| Sealing Cycle Time | < 10 s |
| Warm-up Time | < 2 min |
| Heating Temperature Range | 150–200 °C (adjustable) |
| Dimensions (W × D × H) | 380 × 350 × 245 mm |
| Display | 5-inch TFT LCD touchscreen |
| UV Sterilization | Integrated germicidal UV-C lamp (254 nm) |
| Sealing Mechanism | Pneumatically assisted upward-pressing thermal sealing |
| Maintenance Access | Top-hinged service panel |
| Drainage | Spring-loaded pop-up drip tray |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | HTY-QTS02L |
| Pricing | Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Sealing Speed | ≤9 s per sample |
| Rated Power | 450 W |
| Preheating Time | ≤4 min |
| Weight | 8.5 kg |
| Ambient Temperature Limit | ≤40 °C |
| Operating Temperature Range | 5–45 °C |
| Operating Relative Humidity | ≤75 % RH |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-WOT100 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Sample Injection Volume | 0.5–20.0 mL (recommended: 5.0 mL) |
| Measurable TOC Range | 0–100 mg/L |
| Repeatability Error | ≤3% (at 50% of full scale per JJG 821–2005) |
| Accuracy (TC) | ±5% |
| (IC) | ±4% (at 20%, 50%, and 80% of full scale per JJG 821–2005) |
| Detection Limit | ≤25 ppb (per HJ 501–2009) |
| Dimensions | 550 × 450 × 530 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | SSE-10000 |
| Maximum Sample Carbon Load | 0.1–30.0 mg C |
| Sample Form Compatibility | Solid and Liquid |
| Oxidation Efficiency | ≥99% |
| Repeatability (RSD) | ≤5% |
| Dimensions | 800 × 310 × 270 mm |
| Brand | TCT |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Handset OBD |
| Response Time | 0.01 s |
| Compliance | GB 3847–2018, GB 18285–2018 |
| Connectivity | Bluetooth (BLE 4.2+), USB-C, 4G LTE Cat-4 |
| Integrated Hardware | VCI Diagnostic Interface + Rugged Industrial PDA (Android 11, IP65-rated) |
| Data Transmission | Secure HTTPS/FTP upload to Environmental Protection Bureaus’ OBD Remote Supervision Platforms |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Model | VEMEIS1.0 |
| Application | In-Use Vehicle Emission Compliance Testing (Gasoline, Diesel, Motorcycle) |
| Regulatory Compliance | GB 18285–2018, GB 3847–2018, GB 19758–2005, GB 14621–2002, GB 18352.6–2016 |
| Measurement Principles | NDIR (HC, CO, CO₂), Electrochemical (NO, NO₂, O₂), Lambda Calculation, Opacity (N, K), Charged Particle Counting (PN), Thermal & Inductive Sensing (Oil Temp, RPM) |
| Detection Range | HC 0–20,000 ppm |
| Resolution & Accuracy | As per GB standards (e.g., HC ±4 ppm or ±3% rel., Opacity ±1% abs., PN ±1% FS) |
| Data Transmission | Wireless (4G/LTE), Cloud-Ready API Interface |
| Software | Integrated Emission Database Management, Audit-Trail Logging, GLP-Compliant Reporting |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Model | VRMS1000 |
| Instrument Type | Portable System |
| Max. Permissible Error | ±1% |
| Zero Drift | ±1% |
| Span Drift | ±1% |
| Repeatability | ±1% |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with VECTRA Liquid Autosampler |
| Analytical Method | Combustion Microcoulometry |
| Measurement Range | 0–10,000 ppm |
| Accuracy | ≤2% CV |
| Detection Limit | 10 ppb |
| Resolution | ≤2% CV |
| Brand | LeadTech |
|---|---|
| Origin | Canada |
| Model | Tecta-B16 |
| Detection Principle | Enzyme-Substrate Fluorescence-Based Optical Sensing |
| Microbial Targets | Total Coliforms, Fecal Coliforms, Escherichia coli, Enterococci |
| Sample Throughput | 4 or 16 simultaneous assays |
| Detection Range | 1–10⁵ CFU/100 mL (no dilution required) |
| Limit of Detection | 1 CFU/100 mL |
| Incubation Temperature Control | 20–50 °C |
| Detection Time | 4–18 h (time-to-detection dependent on concentration) |
| Data Output | Direct display, Ethernet/Wi-Fi transmission, SMTP email alerts |
| Compliance | US EPA Method 1603 & 1604, GB/T 5750.12–2006, ISO 9308-1:2014, ASTM D6502-22 |
| Regulatory Readiness | FDA 21 CFR Part 11–compliant audit trail (software-enabled), GLP/GMP data integrity architecture |
| Brand | Tekmar |
|---|---|
| Origin | USA |
| Model | Fusion |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV Light + Sodium Persulfate |
| Measurement Range | 0.2 ppb C to 4,000 ppm C |
| Accuracy | ±1% |
| Detection Limit | 0.2 ppb C |
| Precision (RSD) | ≤1% |
| Regulatory Compliance | EPA Methods 415.1–415.3, 9060A |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 50 ppb |
| Linear Range | 0–20,000 ppm (with 0.5 mL injection volume) |
| Compliance Standards | EPA 415.1/415.3/9060A, ISO 8245, EN 1484, USP <643>, ASTM D2579, SM 5310B, HJ 501-2009, GB/T 32116-2015, AOAC 973.47 |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 500 ppb |
| Quantification Range | 50 ppb – 30,000 ppm |
| Compliance | HJ 501–2009, GB/T 32116–2015, EPA Methods 415.1, 415.3, and 9060A, Standard Methods 5310B, ISO 8245, EN 1484, USP <643>, ASTM D2579, AOAC 973.47 |
| Brand | Telaire |
|---|---|
| Origin | USA |
| Model | 7001 |
| Instrument Type | Portable |
| Detection Target | Multi-component (CO₂, Temperature) |
| CO₂ Range | 0–10,000 ppm |
| CO₂ Resolution | 1 ppm |
| Temperature Resolution | 0.1°C |
| Response Time | ≤60 s |
| Zero Drift | ≤20 ppm |
| Operating Temperature | 0–50°C |
| Storage Temperature | −20–60°C |
| Calibration Interval | 12 months |
| Output | RS-232, 0–4 VDC analog (CO₂ & temperature) |
| Power | 4×AA alkaline batteries (80 h) or 6 VDC external adapter |
| Brand | Teledyne Cetac |
|---|---|
| Origin | USA |
| Model | 465L |
| Measurement Principle | UV Absorption (254 nm) |
| Concentration Range | 0–1 ppm and 0–500 ppm selectable |
| Units | ppmv, ppbv, ppmw, pphm, µg/m³, mg/m³ |
| Accuracy | ±0.1% of full scale |
| Resolution | 0.001 ppm |
| Response Time (T90) | <30 s |
| Sample Flow Rate | 1–2.5 L/min |
| Operating Temperature | 5–45 °C |
| Signal Output | 4–20 mA (isolated), 0–5 V analog |
| Communication Interface | RS-232 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×H×D) | 483 × 133 × 388 mm |
| Weight | 6.17 kg |
| Certification | CE |