| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | FH62C14 |
| Measurement Method | Beta-Ray Absorption |
| Measured Parameter | PM2.5 |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Activity | <3.7 MBq (<100 μCi) |
| Measurement Range | 0–5000 μg/m³ or 0–10000 μg/m³ |
| LOD (24-h avg) | <1 μg/m³ |
| LOD (1-h avg) | <4 μg/m³ |
| Accuracy | ±2 μg/m³ (24-h) |
| Resolution | ±1 μg/m³ (instantaneous) |
| Correlation Coefficient | R > 0.98 |
| Sampling Flow Rate | 1 m³/h (16.67 L/min), adjustable 0–20 L/min via built-in critical orifice |
| Operating Temperature | −30 °C to +60 °C |
| Data Averaging Intervals | 0.5, 1, 3, and 24 hours |
| Storage Capacity | >1 year of half-hourly averages |
| Communication Interfaces | Dual RS-232 serial ports |
| Analog Outputs | 4–20 mA or 0–10 V |
| Power Supply (Analyzer) | 100–240 VAC, 50/60 Hz, 15 W |
| Power Supply (Pump) | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Analyzer) | 483 mm (W) × 311 mm (H) × 330 mm (D) |
| Weight (Analyzer) | 22.5 kg |
| Dimensions (Pump) | 210 mm (W) × 222 mm (H) × 108 mm (D) |
| Weight (Pump) | 8.16 kg |
| Regulatory Certifications | U.S. EPA and California Air Resources Board (CARB) equivalency for PM₂.₅ and PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific GM-5000 |
| Measurement Principle | Optical Scattering (for PM), Electrochemical (for SO₂, NO₂, NO, CO), Photoionization Detection (for TVOC), UV Absorption (for O₃) |
| Measured Parameters | PM₂.₅, PM₁₀, SO₂, NO₂, NO, O₃, CO, TVOC |
| Measurement Range | PM₂.₅ / PM₁₀: 0–1500 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 0–500 ppb |
| CO | 0–50 ppm |
| TVOC | 0–40 ppm |
| Sampling Interval | 10 s |
| Sample Flow Rate | >1.5 L/min |
| Detection Limits | PM₂.₅ / PM₁₀ <1.0 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 5 ppb |
| CO | 0.02 ppm |
| TVOC | 5 ppb |
| Flow Stability | ±2.5% of full scale (all sensors) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | GM-5000 |
| Instrument Type | Online Fixed-Station Monitor |
| Measured Gases | NO₂, SO₂, O₃, CO |
| Response Time (T90) | 120 s (all sensors) |
| Measurement Accuracy | ±10 ppb (gaseous pollutants) |
| Measurement Ranges | NO₂: 0–20 ppm |
| SO₂ | 0–50 ppm |
| O₃ | 0–20 ppm |
| CO | 0–500 ppm |
| PM₂.₅ | 0–1500 µg/m³ |
| PM₁₀ | 0–1500 µg/m³ |
| Detection Limits (2σ) | NO₂: 30 ppb |
| SO₂ | 40 ppb |
| O₃ | 30 ppb |
| CO | 25 ppb |
| PM₂.₅ & PM₁₀ | <1.0 µg/m³ |
| Linearity | ±5% of full scale |
| Zero Drift | ±1% of full scale |
| Repeatability | ±2.5% of full scale |
| Resolution | 10 ppb (gases), 0.1 µg/m³ (PM) |
| Sample Flow Rate | >1.5 L/min |
| Data Logging Interval | 1 min to 1 h |
| Onboard Storage | >500,000 records (~1 year) |
| Operating Temperature | –10 °C to +45 °C |
| Operating Humidity | 15–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Dimensions | 406 mm (H) × 305 mm (W) × 152 mm (D) |
| Weight | 5 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD |
| Instrument Category | Radiation Dosimetry / Dose Rate Meter |
| Form Factor | Personal/Environmental Wearable |
| Measured Radiation Types | Photons, Beta Particles, Thermal Neutrons, Fast Neutrons |
| Detector Material | LiF:Mg,Cu,P |
| LiF | Mg,Ti |
| Dosimetric Quantities | Hp(10), Hp(3), Hp(0.07), H*(10), H′(0.07), Neutron Fluence-to-Dose Conversion |
| Window Thickness | 3.3 mg/cm² (beta), 42 mg/cm² (photon), 7 mg/cm² (TLD-100/H/700H), 100 mg/cm² (TLD-100 for high-energy photon attenuation) |
| Element Dimensions | 3 mm × 0.4 mm (neutron-sensitive chips) |
| Compliance | ANSI N545-1993, ANSI N13.32-1995, ANSI N13.37 (draft), DOELAP, NVLAP-accredited testing protocols |
| Software | Integrated dose calculation software with ANSI/ISO traceable algorithms |
| Packaging | Hermetically sealed, barcoded, contamination-resistant encapsulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Hg CEMS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRAN SapphIRe |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 3880i |
| Instrument Type | Flue Gas PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM) |
| Traceability | NIST-traceable mass concentration |
| Compliance | EPA PS-11, QA/QC Procedure 2, Method 5/17 Verified |
| Range | 0–250 mg/m³ (extendable to 0–5 mg/m³ low-range mode) |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integrated) |
| Response Time (T90) | 15 min |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Purge Air | 80 slpm at 0.55–0.7 MPa |
| Max Flue Gas Temp | 200 °C |
| Operating Ambient Temp (Controller) | 4–50 °C, non-condensing |
| Analog Outputs | 6 × 0–100 mV / 1/5/10 V, 6 × 0–20 mA / 4–20 mA |
| Digital I/O | 1 power-fail alarm, 10 relay outputs |
| Probe Dimensions | 1117.85 mm (W) × 474.73 mm (H) × 7.09 mm (D), with 914/1524 mm sheath |
| Probe Weight | 59 kg |
| Controller Dimensions | 482.6 mm (19″ W) × 189.5 mm (H) × 655.32 mm (D) |
| Controller Weight | 25 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410 |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Model 5014i Beta |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Range Options | 0–1.0 / 2.0 / 3.0 / 5.0 / 10.0 mg/m³ (equivalent to 0–100 / 1,000 / 2,000 / 3,000 / 5,000 / 10,000 µg/m³) |
| LOD | 6 µg/m³ (0.5-hr avg), 4 µg/m³ (1-hr avg), 3 µg/m³ (3-hr avg), 1 µg/m³ (24-hr avg) |
| Resolution | 1 µg/m³ |
| Accuracy | ±5% (mass measurement, NIST-traceable membrane standards) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Thermo Scientific 5030 SHARP (High-Volume Sampling Configuration) |
| Instrument Type | High-Volume Ambient Air Sampler |
| Sampling Path | Single-Channel |
| Flow Range | PM₁₀ & PM₂.₅: 40 SCFM (1,133 L/min) |
| Flow Accuracy | Mass Flow Control: ±2.5% deviation over 24 h |
| Volumetric Flow Control | <1% deviation over 24 h |
| Power | 750 W (Mass Flow) / 840 W (Volumetric Flow) |
| Motor | 0.6 HP (Mass Flow) / 0.1 HP (Volumetric Flow) |
| Compliance | EPA Reference Method for PM₁₀/PM₂.₅ (40 CFR Part 53), ISO 12103-1, ASTM D1424 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MPC 20 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluoride ISE (CS00F02) |
| Instrument Type | Fluoride Ion Selective Electrode |
| Measurement Range | 0.02 ppm to saturation |
| Compliance | ASTM D1129, ISO 10523, USP <771>, EPA Method 300.0 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Temperature Control | Integrated thermostatically controlled cuvette with magnetic stirring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue Reaction) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Sample Throughput | Continuous online operation (no batch processing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation Range | 0–45 ppt |
| Atmospheric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane sensor |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | Data logging (200 entries), calibration history (last 10), method storage (10), self-test diagnostics, password protection, network-enabled firmware/software updates |
| Power | 4×AA batteries + universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Enclosure Rating | IP54 (benchtop) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-24 |
| Pricing | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | Up to 0.001 µS/cm (4 significant digits) |
| Conductivity Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19,999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 point |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Sensor Interfaces | Conductivity – miniDIN |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Self-Diagnostic Function | Yes |
| Password Protection | Yes |
| Firmware/Method Update | Network-enabled |
| Power Supply | 4 × AA batteries or universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | IP54 (benchtop) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Orion 3150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measuring Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Range | 0–2 / 0–10 / 0–50 mg/L (user-selectable ranges per parameter) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Light Source (TN module) | Xenon flash lamp (rated for >10⁸ flashes) |
| Sample Handling | Integrated digestion-colorimetric cell with automated reagent dosing and thermal digestion |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 3150 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measurement Ranges | 0–2 mg/L, 0–10 mg/L, 0–50 mg/L (auto-ranging) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| [Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| DO Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | 200 data points, last 10 calibrations stored, 10 user methods, self-test diagnostics, password protection, network-enabled firmware/method updates |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| IP Rating | Benchtop—IP54 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410D-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410P-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 420D-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 420P-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 510M-01 (Benchtop), 520M-01 (Portable) |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Orion 7070iX TRO |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0.02–2) mg/L |
| Accuracy | ±3% of reading ±0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Resolution | 0.001 mg/L (<100 mg/L) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample pH | 4–9 |
| Max. Turbidity (NTU) | <30 |
| Max. Color (Pt-Co) | <180 |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM, FCC, CE-EMC, CE-RoHS, REACH, China RoHS |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | 0.02–2 mg/L |
| Accuracy | ±3% of reading + 0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Environmental Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample Requirements | TDS < 170 mg/L, TSS < 30 mg/L, pH 4–9, Color < 180 Pt-Co units |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM (safety) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 8030cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Heteropoly Molybdenum Blue Colorimetry |
| Detection Range | 0–5000 µg/L SiO₂ |
| LOD | <0.5 µg/L (typical, phosphate-compensated) |
| Enclosure Rating | IP65 |
| Reagent Replacement Interval | ≤100 days |
| User Interface | Capacitive Touchscreen Display |
| Platform Compatibility | Orion 8000 Series Multi-Parameter Platform |
| Compliance | Designed for GLP/GMP-aligned operation |