BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Industrial Online ORP Analyzer
ModelPM8202P
Instrument TypeIndustrial Online ORP Analyzer
Measurement Range−2000 to +2000 mV
Resolution1 mV
Accuracy±1 mV
Temperature Compensation−10 to 130 °C (NTC10K / PT1000, manual or automatic)
DisplayBacklit large-dot-matrix LCD
Data Storage600,000 records with query function
OutputDual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS), RS485 Modbus RTU
Relay Outputs2 independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC), 1 multifunction relay for cleaning/cycle/error alerts
Cleaning ControlAdjustable interval (0.1–1000 h) and duration (1–1000 s)
Enclosure RatingIP65
Mounting OptionsWall-mount, pipe-mount, panel-mount
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Electrode ModelBsens210
Electrode Measuring Range−2000 to +2000 mV
Electrode Accuracy±1 mV
Electrode Sensing ElementPlatinum reference electrode with glass body
ElectrolytePolymer-based gel
Max. Operating Pressure6 bar
ConnectionPG13.5 fixed thread
Reference JunctionOpen-flow junction
Cable Length5 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Industrial Online ORP Meter
ModelPM 820 2P
Instrument TypeIndustrial Online ORP Analyzer
pH Range-2.00 to 16.00 pH
ORP Range-2000 to +2000 mV
Temperature Range0 to 130 °C
pH Resolution0.01 pH
ORP Resolution1 mV
Temperature Resolution0.1 °C
pH Accuracy±0.01 pH
ORP Accuracy±1 mV
Temp. Accuracy±0.1 °C
Temperature Compensation-10 to 130 °C (NTC10K / PT1000, manual or auto)
Operating Temp.-10 to 70.0 °C
Storage Temp.-20 to 70.0 °C
DisplayBacklit graphic LCD
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or 24 VDC (optional)
Analog Outputs2 isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS)
CommunicationRS485 Modbus RTU
Cleaning OutputAdjustable interval (0.1–1000 h), duration (1–1000 s)
Alarm Outputs2 independent Hi/Lo relays (5 A / 250 VAC / 30 VDC)
Enclosure RatingIP65
Mounting OptionsWall-mounted, pipe-mounted, panel-mounted
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOEM Manufacturer
Origin CategoryImported
ModelPM8202P
Instrument TypeIndustrial Online ORP Meter
pH Range-2.00 to 16.00 pH
ORP Range-2000 to +2000 mV
Temperature Range0 to 130 °C
pH Resolution0.01 pH
ORP Resolution1 mV
Temperature Resolution0.1 °C
pH Accuracy±0.01 pH
ORP Accuracy±1 mV
Temp. Accuracy±0.1 °C
Temp. Compensation-10 to 130 °C (NTC10k or PT1000, manual/automatic)
Operating Temp.-10 to 70.0 °C
Storage Temp.-20 to 70.0 °C
DisplayBacklit Graphic LCD
Language SupportEnglish & Chinese
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or 24 VDC (optional)
Analog OutputsTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for measured value or range)
CommunicationRS485 Modbus RTU
Cleaning Control OutputAdjustable interval (0.1–1000 h) and duration (1–1000 s)
Alarm OutputsTwo independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, programmable hysteresis)
Mounting OptionsWall-mount, pipe-mount, panel-mount
Enclosure RatingIP65
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM 820 2P
Instrument TypeIndustrial Online ORP Meter
pH Range-2.00 to 16.00 pH
ORP Range-2000 to +2000 mV
Temperature Range0 to 130 °C
pH Resolution0.01 pH
ORP Resolution1 mV
Temp Resolution0.1 °C
pH Accuracy±0.01 pH
ORP Accuracy±1 mV
Temp Accuracy±0.1 °C
Temp Compensation-10 to 130 °C (NTC10K/PT1000, manual/auto)
Operating Temp-10 to 70.0 °C
Storage Temp-20 to 70.0 °C
DisplayBacklit dot-matrix LCD
LanguageEnglish/Chinese
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or 24 VDC optional
Isolated 4–20 mA Outputs2 channels, max loop resistance 500 Ω, accuracy 0.1% F.S.
CommunicationRS485 Modbus RTU
Cleaning OutputAdjustable interval (0.1–1000 h), duration (1–1000 s)
Alarm Outputs2 independent Hi/Lo relays, adjustable hysteresis, 5 A / 250 VAC / 30 VDC
Enclosure RatingIP65
MountingWall-mounted, pipe-mounted, panel-mounted
Dimensions144 × 144 × 108 mm
Cut-out138 × 138 mm
Weight0.87 kg