- All
- Favorite
- Popular
- Most rated
| Brand | GreenPrima |
|---|---|
| Origin | Austria |
| Manufacturer | GreenPrima GmbH |
| Model | PM8200M |
| Type | Online Suspended Solids Analyzer |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Range | 0–50 g/L |
| Resolution | 0.01 g/L |
| Temperature Compensation | -10–130 °C (NTC10K/PT1000) |
| Display | Backlit Graphic LCD (Bilingual: EN/CH) |
| Outputs | Dual Isolated 4–20 mA (0.1% FS), RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable Interval (0.1–1000 h) & Duration (1–1000 s) |
| Alarm | 2 Independent Hi/Lo Relays (5 A / 250 VAC) |
| Enclosure Rating | IP65 (Controller), IP68 (Bsens550 Sensor) |
| Power | 90–260 VAC, 50/60 Hz or 24 VDC |
| Dimensions (W×H×D) | 144 × 144 × 106 mm |
| Weight | 0.86 kg |
| Sensor Material | Delrin® |
| Max Pressure | 5 bar |
| Response Time | <30 s |
| Cable Length | 7 m (standard) |
| Brand | GreenPrima |
|---|---|
| Model | PM 8200S |
| Measurement Principle | Infrared Monochromatic Light Scattering |
| Range | 0.00–4000.00 NTU / 0.00–4500.00 mg/L |
| Resolution | 0.1 NTU (display), 0.01–1 NTU/mg/L (sensor) |
| Accuracy | ±2% F.S. |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | −20–70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max 500 Ω, 0.1% F.S.) |
| Communication | RS485, MODBUS RTU protocol |
| Relay | 1 multifunctional relay (cleaning, periodic alarm, fault alarm) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting | Wall-mount, pole-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens580 |
| Sensor Material | PVC & Delrin |
| Max Pressure | 5 bar |
| Cable Length | 7 m |
| Response Time | <1 s |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8200 S |
| Instrument Type | Online |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Compliance | EN ISO 7027 |
| Sensor Type | Bsens580 High-Turbidity Sensor |
| Measuring Range | 5–4000 NTU / 0–4500 mg/L (as SS) |
| Resolution | 0.01–1 NTU (or mg/L) |
| Accuracy | < ±5% of reading |
| Temperature Compensation | NTC10K or PT1000, -10 to 130 °C (manual/automatic) |
| Operating Temperature (Controller) | 0–70 °C |
| Operating Temperature (Sensor) | 0–50 °C |
| Storage Temperature | -20 to 70 °C |
| Max. Pressure (Sensor) | 5 bar |
| Sensor Housing | IP68 |
| Controller Enclosure | IP65 |
| Display | Backlit dot-matrix LCD with Chinese/English menu |
| Output | Dual isolated 4–20 mA (0.1% FS, max. 500 Ω), RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (Controller) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight (Controller) | 0.86 kg |
| Sensor Dimensions | Ø27 × 170 mm |
| Standard Cable Length | 7 m |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8200S+BSens550 |
| Instrument Type | Online |
| Measurement Principle | 90° Light Scattering (EN ISO 7027 Compliant) |
| Controller Display | Sludge Concentration, Relay Status, Sensor Model |
| Language | English/Chinese |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (Concentration & Temperature), Max. Load 600 Ω |
| Digital Output | RS485 Modbus RTU |
| Alarm Outputs | Two Independent Hi/Lo Setpoints with Hysteresis, 5 A / 250 VAC |
| Cleaning Interval | Field-Configurable (1–999 hours) |
| Operating Temperature (Controller) | −10 to +60 °C |
| Enclosure Rating (Controller) | IP65 / NEMA 4X |
| Mounting | Wall-Mount |
| Dimensions (Controller) | 144 × 144 × 108 mm |
| Sensor Model | innoSens 550 |
| Sensor Measurement Range | 0–50 g/L |
| Resolution | 0.1 NTU / 0.1 mg/L |
| Accuracy | ±2% of Full Scale |
| Sensor Housing Material | Delrin® |
| Cable Length | Standard 7 m |
| Max. Pressure Rating (Sensor) | 5 bar |
| Sensor Operating Temperature | 0–60 °C |
| Sensor Enclosure Rating | IP68 |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8202T |
| Instrument Type | Online |
| Measurement Principle | Infrared 90° Nephelometry (Compliant with EN ISO 7027) |
| Temperature Compensation Range | –10 to 130 °C (Manual/Automatic, NTC30k or PT1000 sensor support) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Interface | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% F.S.) |
| Digital Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable cleaning interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay alarms (5 A / 250 VAC / 30 VDC, hysteresis configurable) |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200S |
| Instrument Type | Online |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Compliance | EN ISO 7027 |
| Sensor Type | Bsens580L Low-Turbidity Sensor |
| Range | 0–10 NTU / 0–100 NTU |
| Resolution | 0.01 NTU (0–10 NTU), 0.1 NTU (0–100 NTU) |
| Accuracy | ±1% FS (0–10 NTU), ±2% FS (0–50 NTU), ±5% FS (0–100 NTU) |
| Operating Temp. | 0–50 °C (sensor), –10–70.0 °C (controller) |
| Max. Pressure | 4 bar |
| Output | Dual isolated 4–20 mA, RS485 Modbus RTU, optional HART |
| Enclosure Rating | IP65 (controller), IP68 (sensor) |
| Display | Backlit dot-matrix LCD with Chinese/English menu |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC option |
| Dimensions (controller) | 144 × 144 × 106 mm |
| Mounting | Wall, pipe, or panel mount |
| Weight | 0.86 kg |