Empowering Scientific Discovery

GOP Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM8202I
PriceUpon Request
Measurement Range0.00–20000 ppm
Resolution0.0 / 0.1 / 1 ppm
Accuracy±0.01 / ±0.1 / ±1 ppm
Temperature Compensation–10 to 130 °C (manual/automatic, NTC30K or PT1000)
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
LanguageChinese/English
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
OutputTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU
Enclosure RatingIP66/IP67 (fully sealed, waterproof & gas-tight)
Electrode CompatibilityBsens710 (F⁻), Bsens720 (Cl⁻), Bsens730 (NH₃-N)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON5000
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelPM 8202I
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM 8202I
PriceUpon Request
Measurement Range0.00–20,000 ppm F⁻
Resolution0.0 / 0.1 / 1 ppm (user-selectable)
Accuracy±0.01 / ±0.1 / ±1 ppm (dependent on range)
Temperature Compensation–10 to 130 °C (manual or automatic
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
Interface LanguageEnglish & Chinese
Data Storage Capacity600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Analog OutputsTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature)
Digital CommunicationRS485 Modbus RTU
Enclosure RatingIP66/IP67 (fully sealed, moisture- and gas-resistant)
Electrode CompatibilityBsens710 Fluoride ISE, Bsens720 Chloride ISE, Bsens730 Ammonia ISE
CalibrationManual or scheduled two-point calibration with password-protected access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Output Options4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min (configurable) or triggered by external/flow signal
Rinse Duration15–1800 s (user-configurable)
Sample Water RequirementspH 4–10
Environmental Operating Range10–40 °C
Compatible Units°dH, °f, ppm CaCO₃, mmol/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM8202I
Measurement Range0.00–20,000 ppm F⁻
Resolution0.0 / 0.1 / 1 ppm (selectable)
Accuracy±0.01 / ±0.1 / ±1 ppm (depending on range)
Temperature Compensation–10 to 130 °C (manual or automatic
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
LanguageEnglish & Chinese
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
OutputTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for measured value or temperature
CommunicationRS485 Modbus RTU
Enclosure RatingIP67-rated sealed housing
Electrode CompatibilityBSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelAqualysis 800A
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelPROCON3000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Output Options4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min (configurable) or triggered externally/flow-synchronized
Rinse Duration15–1800 s (user-configurable)
Sample Water RequirementspH 4–10
Environmental Operating Range10–40 °C
Units Supported°dH, °f, ppm CaCO₃, mmol/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Measurable Units°dH, °f, ppm CaCO₃, mmol/L
Outputs4 programmable relay outputs (max. 250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485
Inputs2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min, external trigger, or flow-signal synchronized
Rinse DurationConfigurable (15–1800 s)
Sample Water RequirementspH 4–10
Environmental Operating Temp.10–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON5000
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Output Options4 programmable relay outputs (250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 interface
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min (configurable) or triggered by external/flow signal
Rinse Duration15–1800 s (user-configurable)
Sample Water RequirementspH 4–10
Environmental Operating Temp.10–40 °C
Units Supported°dH, °f, ppm CaCO₃, mmol/L