| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD8200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | MODBUS RTU (optional) |
| Alarm Outputs | High/Low relay contacts |
| Enclosure Rating | IP65 |
| Dimensions | 279 × 152 mm (11.0" × 6.0") |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD8200 |
| Price | Upon Request |
| Power Supply | 230 VAC, 50 Hz |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Zero Auto-Calibration | Yes |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication Protocol | MODBUS (optional) |
| Alarm Outputs | High/Low relay |
| Enclosure Rating | IP65 |
| Dimensions | 11.0" × 6.00" |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20000 ppm |
| Resolution | 0.0 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic, NTC30K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | Chinese/English |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, waterproof & gas-tight) |
| Electrode Compatibility | Bsens710 (F⁻), Bsens720 (Cl⁻), Bsens730 (NH₃-N) |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SC D8200 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Measurement Range | –1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" NPT |
| Outlet Connection | 3/4" NPT |
| Response Time | ≤1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, –10 to +10 V, 0–10 V |
| Communication | MODBUS RTU (RS-485, optional) |
| Alarm Outputs | Dual SPDT relays (high/low) |
| Enclosure Rating | IP65 |
| Dimensions | 279 mm × 152 mm (11.0" × 6.0") |
| Weight | 9 kg |
| Zero Calibration | Automatic |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DPD-Aqualysis800 |
| Price | Upon Request |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (hardness-dependent) |
| Accuracy | ±2% of selected reagent’s upper range |
| Repeatability | ±2% of selected reagent’s upper range |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 180 mm |
| Weight | 4 kg |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Sample pH Range | 4–10 |
| Interference Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Output Options | 4 programmable relay outputs (max. 250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 Modbus RTU port |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Flush Duration | Configurable (15–1800 s) |
| Reagent Kits | TH7000 to TH7100 (7 ranges, covering 0.177–625.8 ppm CaCO₃ equivalent) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online Analyzer |
| Model | PM8202C |
| Application | Continuous Process Monitoring in Industrial Water, Wastewater, and Chemical Processing |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Conductivity Resolution | 0.01 mS/cm |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Accuracy | ±1% of Full Scale |
| Temperature Range | –10 to +130 °C (manual/automatic compensation |
| Operating Temperature | –10 to +70 °C |
| Storage Temperature | –20 to +70 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese (configurable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Digital Communication | RS485 Modbus RTU (HART optional) |
| Relay Outputs | One multifunction relay (programmable), two independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD 8200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" |
| Outlet Connection | 3/4" |
| Response Time | 1 s |
| Sensor Material | Delrin / 316 Stainless Steel / PTFE |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | Optional MODBUS RTU (RS-485) |
| Alarm Outputs | High/Low Relay |
| Enclosure Rating | IP65 |
| Dimensions | 279 × 152 mm (11.0" × 6.00") |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online ORP Analyzer |
| Model | PM8202P |
| Instrument Type | Industrial Online ORP Analyzer |
| Measurement Range | −2000 to +2000 mV |
| Resolution | 1 mV |
| Accuracy | ±1 mV |
| Temperature Compensation | −10 to 130 °C (NTC10K / PT1000, manual or automatic) |
| Display | Backlit large-dot-matrix LCD |
| Data Storage | 600,000 records with query function |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS), RS485 Modbus RTU |
| Relay Outputs | 2 independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC), 1 multifunction relay for cleaning/cycle/error alerts |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Electrode Model | Bsens210 |
| Electrode Measuring Range | −2000 to +2000 mV |
| Electrode Accuracy | ±1 mV |
| Electrode Sensing Element | Platinum reference electrode with glass body |
| Electrolyte | Polymer-based gel |
| Max. Operating Pressure | 6 bar |
| Connection | PG13.5 fixed thread |
| Reference Junction | Open-flow junction |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PM 8202I |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (dependent on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Interface Language | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, moisture- and gas-resistant) |
| Electrode Compatibility | Bsens710 Fluoride ISE, Bsens720 Chloride ISE, Bsens730 Ammonia ISE |
| Calibration | Manual or scheduled two-point calibration with password-protected access |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8202I |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) for Calcium |
| Range | 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent) |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm) |
| Temperature Compensation | -10 to +130 °C (NTC30k or PT1000 sensor, manual/automatic) |
| Operating Temperature | -10 to +70.0 °C |
| Storage Temperature | -20 to +70.0 °C |
| Display | Backlit high-resolution dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Optional | 24 VDC |
| Output | Two isolated 4–20 mA analog outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for calcium concentration and temperature |
| Relay Output | One multifunctional relay (cleaning trigger, periodic alarm, fault alert) |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode | Integrated BSENS740 calcium-selective composite electrode |
| Calibration | Two-point calibration with standard solutions (e.g., 100 ppm & 1000 ppm Ca²⁺) |
| Compliance | Designed per IEC 61000-6-2 (EMC immunity), IEC 61000-6-4 (EMC emission), and EN 61326-1 (laboratory & industrial measurement equipment) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online ORP Meter |
| Model | PM 820 2P |
| Instrument Type | Industrial Online ORP Analyzer |
| pH Range | -2.00 to 16.00 pH |
| ORP Range | -2000 to +2000 mV |
| Temperature Range | 0 to 130 °C |
| pH Resolution | 0.01 pH |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH |
| ORP Accuracy | ±1 mV |
| Temp. Accuracy | ±0.1 °C |
| Temperature Compensation | -10 to 130 °C (NTC10K / PT1000, manual or auto) |
| Operating Temp. | -10 to 70.0 °C |
| Storage Temp. | -20 to 70.0 °C |
| Display | Backlit graphic LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Analog Outputs | 2 isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | 2 independent Hi/Lo relays (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | PRIMASCI |
|---|---|
| Origin | Shanghai, China |
| Model | innoLab 10 C |
| Portability | Handheld |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–100.0 MΩ·cm |
| Salinity Range | 0–325 ppt (Practical Salinity Scale) |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±1% F.S. (Conductivity), ±0.3 °C (Temperature) |
| Resolution | 0.001 µS/cm (low range), 0.01 mS/cm (high range), 0.1 °C |
| Calibration | Auto-ranging 1-point or manual multi-point (up to 3 points) |
| Temperature Compensation | Automatic/manual, −5 to +120 °C, selectable reference temp (15–30 °C, default 25 °C) |
| Electrode Constants | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Factor | 0.40–1.00 (adjustable) |
| Salinity Factor | 0.65 (PSS-78 compliant) |
| Memory Capacity | 100 data sets with timestamp |
| Display | 40 × 70 mm LCD, 120° viewing angle |
| IP Rating | IP67 |
| Power | 2 × AA alkaline batteries (>500 h operation) |
| Dimensions | 73 × 152 × 42 mm (W × L × H) |
| Weight | 250 g |
| Brand | PRIMA SCI (UK) |
|---|---|
| Origin | Shanghai, China |
| Model | innoLab 10P |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH/ORP/Temp) |
| Measurement Range | 0.00–14.00 pH (extended: –2.00 to +16.00 pH), –2000 to +2000 mV, –5.0 to 120.0 °C |
| Resolution | 0.01 pH, 0.1 mV (±600.0 mV), 1 mV (full range), 0.1 °C/0.1 °F |
| Accuracy | ±0.01 pH, ±0.2 mV (±600.0 mV), ±1 mV (full range), ±0.3 °C / ±0.5 °F |
| Calibration | Auto-recognition of 1–3 point NIST-traceable buffer calibration |
| Temperature Compensation | Automatic (ATC) or Manual (MTC), –5.0 to +120.0 °C |
| Electrode Interface | BNC + 3.5 mm temperature probe jack |
| Display | 43 × 70 mm LCD, 120° viewing angle |
| Housing Rating | IP65 |
| Dimensions | 73 × 152 × 42 mm (W × H × D) |
| Weight | 250 g |
| Power | 2 × 1.5 V AA alkaline batteries (>500 h operation) |
| Data Storage | Optional 100-point memory |
| Auto-Off | Selectable (10 min idle timeout) |
| Key Features | Differential signal circuitry, electrode health diagnostics (Slope/Offset), STABLE reading indicator, MTC fallback mode, ergonomic grip, scratch-resistant display |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered by external/flow signal |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Compatible Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PM8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent) |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm) |
| Temperature Compensation | –10 to +130 °C (NTC30k or PT1000 sensor input, manual/automatic) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for Ca²⁺ concentration or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle Control | Interval adjustable from 0.1 to 1000 h |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC), with user-defined hysteresis |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for measured value or temperature |
| Communication | RS485 Modbus RTU |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode Compatibility | BSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N) |
| Brand | PRIMASCI |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20C |
| Form Factor | Benchtop |
| Conductivity Range | 0–500 mS/cm |
| TDS Range | 0–500,000 ppm (as NaCl) |
| Resistivity Range | 0–18.30 MΩ·cm |
| Salinity Range | 0–325 ppt |
| Temperature Range | −5 to +120 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm (at lowest range) |
| Electrode Constants Supported | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic or Manual (−5 to 120 °C), Reference Temp: 15–30 °C (default 25 °C) |
| TDS Conversion Factor | Adjustable 0.40–1.00 |
| Salinity Conversion Factor | Fixed 0.65 |
| Data Storage | 100 measurement records |
| Power | AC 100–240 V + internal rechargeable Li-ion battery (1300 mAh) |
| Dimensions | 150 × 194 × 56 mm (W × L × H) |
| Weight | 1.0 kg |
| Key | Brand: GreenPrima |
|---|---|
| Origin | Switzerland |
| Model | PM8202P |
| Measurement Range | 0.00–14.00 pH, −2000 to +2000 mV, 0–130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Calibration Standard | NIST-traceable buffers |
| Temperature Compensation | Automatic/manual (NTC10k or PT1000) |
| Output | Dual isolated 4–20 mA, RS485 Modbus RTU |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC / 50–60 Hz or 24 VDC option |
| Mounting | Wall, panel, or pipe |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualysis 800A |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON3000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered externally/flow-synchronized |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Measurable Units | °dH, °f, ppm CaCO₃, mmol/L |
| Outputs | 4 programmable relay outputs (max. 250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min, external trigger, or flow-signal synchronized |
| Rinse Duration | Configurable (15–1800 s) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Temp. | 10–40 °C |