Empowering Scientific Discovery

GOP Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelSCD8200
PriceUpon Request
Power Supply100–240 VAC
Measurement Range−1000 to +1000 mV
Accuracy±0.1% of full scale
DisplayLED
Flow Rate1 L/min
Inlet Connection1/2"
Outlet Connection3/4"
Response Time1 s
Sensor MaterialDelrin / 316 Stainless Steel / PTFE
Output Signals4–20 mA, −10 to +10 V, 0–10 V
CommunicationMODBUS RTU (optional)
Alarm OutputsHigh/Low relay contacts
Enclosure RatingIP65
Dimensions279 × 152 mm (11.0" × 6.0")
Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelSCD8200
PriceUpon Request
Power Supply230 VAC, 50 Hz
Measurement Range−1000 to +1000 mV
Accuracy±0.1% of full scale
DisplayLED
Flow Rate1 L/min
Inlet Connection1/2"
Outlet Connection3/4"
Response Time1 s
Zero Auto-CalibrationYes
Sensor MaterialDelrin / 316 Stainless Steel / PTFE
Output Signals4–20 mA, −10 to +10 V, 0–10 V
Communication ProtocolMODBUS (optional)
Alarm OutputsHigh/Low relay
Enclosure RatingIP65
Dimensions11.0" × 6.00"
Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM8202I
PriceUpon Request
Measurement Range0.00–20000 ppm
Resolution0.0 / 0.1 / 1 ppm
Accuracy±0.01 / ±0.1 / ±1 ppm
Temperature Compensation–10 to 130 °C (manual/automatic, NTC30K or PT1000)
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
LanguageChinese/English
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
OutputTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU
Enclosure RatingIP66/IP67 (fully sealed, waterproof & gas-tight)
Electrode CompatibilityBsens710 (F⁻), Bsens720 (Cl⁻), Bsens730 (NH₃-N)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelSC D8200
Power Supply100–240 VAC, 50/60 Hz
Measurement Range–1000 to +1000 mV
Accuracy±0.1% of full scale
DisplayLED
Flow Rate1 L/min
Inlet Connection1/2" NPT
Outlet Connection3/4" NPT
Response Time≤1 s
Sensor MaterialDelrin / 316 Stainless Steel / PTFE
Output Signals4–20 mA, –10 to +10 V, 0–10 V
CommunicationMODBUS RTU (RS-485, optional)
Alarm OutputsDual SPDT relays (high/low)
Enclosure RatingIP65
Dimensions279 mm × 152 mm (11.0" × 6.0")
Weight9 kg
Zero CalibrationAutomatic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelDPD-Aqualysis800
PriceUpon Request
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (hardness-dependent)
Accuracy±2% of selected reagent’s upper range
Repeatability±2% of selected reagent’s upper range
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions (H×W×D)400 × 300 × 180 mm
Weight4 kg
DisplayColor LCD with bilingual (English/Chinese) interface
Measurement ModesContinuous or interval (1–360 min)
Sample Temperature Range5–40 °C
Ambient Operating Temperature10–40 °C
Sample Pressure Range0.2–5 bar (recommended: 1–2 bar)
Sample pH Range4–10
Interference LimitsFe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm
Output Options4 programmable relay outputs (max. 250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 Modbus RTU port
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Flush DurationConfigurable (15–1800 s)
Reagent KitsTH7000 to TH7100 (7 ranges, covering 0.177–625.8 ppm CaCO₃ equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Industrial Online Analyzer
ModelPM8202C
ApplicationContinuous Process Monitoring in Industrial Water, Wastewater, and Chemical Processing
Conductivity Range0.00–2000 mS/cm
Salinity Range0.00–78.00 ppt
TDS Range0–120,000 ppm
Conductivity Resolution0.01 mS/cm
Salinity Resolution0.01 ppt
TDS Resolution1 ppm
Accuracy±1% of Full Scale
Temperature Range–10 to +130 °C (manual/automatic compensation
Operating Temperature–10 to +70 °C
Storage Temperature–20 to +70 °C
DisplayBacklit large-dot-matrix LCD
LanguageEnglish & Chinese (configurable)
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Analog OutputsTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS)
Digital CommunicationRS485 Modbus RTU (HART optional)
Relay OutputsOne multifunction relay (programmable), two independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC)
Cleaning Control OutputAdjustable interval (0.1–1000 h) and duration (1–1000 s)
Enclosure RatingIP65
Mounting OptionsWall-mount, panel-mount, pipe-mount
Dimensions (W×H×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON5000
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelSCD 8200
PriceUpon Request
Power Supply100–240 VAC
Measurement Range−1000 to +1000 mV
Accuracy±0.1% of full scale
DisplayLED
Flow Rate1 L/min
Inlet Connection1/2"
Outlet Connection3/4"
Response Time1 s
Sensor MaterialDelrin / 316 Stainless Steel / PTFE
Output Signals4–20 mA, −10 to +10 V, 0–10 V
CommunicationOptional MODBUS RTU (RS-485)
Alarm OutputsHigh/Low Relay
Enclosure RatingIP65
Dimensions279 × 152 mm (11.0" × 6.00")
Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Industrial Online ORP Analyzer
ModelPM8202P
Instrument TypeIndustrial Online ORP Analyzer
Measurement Range−2000 to +2000 mV
Resolution1 mV
Accuracy±1 mV
Temperature Compensation−10 to 130 °C (NTC10K / PT1000, manual or automatic)
DisplayBacklit large-dot-matrix LCD
Data Storage600,000 records with query function
OutputDual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS), RS485 Modbus RTU
Relay Outputs2 independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC), 1 multifunction relay for cleaning/cycle/error alerts
Cleaning ControlAdjustable interval (0.1–1000 h) and duration (1–1000 s)
Enclosure RatingIP65
Mounting OptionsWall-mount, pipe-mount, panel-mount
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Electrode ModelBsens210
Electrode Measuring Range−2000 to +2000 mV
Electrode Accuracy±1 mV
Electrode Sensing ElementPlatinum reference electrode with glass body
ElectrolytePolymer-based gel
Max. Operating Pressure6 bar
ConnectionPG13.5 fixed thread
Reference JunctionOpen-flow junction
Cable Length5 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelPM 8202I
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM 8202I
PriceUpon Request
Measurement Range0.00–20,000 ppm F⁻
Resolution0.0 / 0.1 / 1 ppm (user-selectable)
Accuracy±0.01 / ±0.1 / ±1 ppm (dependent on range)
Temperature Compensation–10 to 130 °C (manual or automatic
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
Interface LanguageEnglish & Chinese
Data Storage Capacity600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Analog OutputsTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature)
Digital CommunicationRS485 Modbus RTU
Enclosure RatingIP66/IP67 (fully sealed, moisture- and gas-resistant)
Electrode CompatibilityBsens710 Fluoride ISE, Bsens720 Chloride ISE, Bsens730 Ammonia ISE
CalibrationManual or scheduled two-point calibration with password-protected access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPM8202I
Measurement PrinciplePotentiometric Ion-Selective Electrode (ISE) for Calcium
Range0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent)
Resolution0.01 / 0.1 / 1 ppm (user-selectable)
Accuracy±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm)
Temperature Compensation-10 to +130 °C (NTC30k or PT1000 sensor, manual/automatic)
Operating Temperature-10 to +70.0 °C
Storage Temperature-20 to +70.0 °C
DisplayBacklit high-resolution dot-matrix LCD
Language SupportEnglish & Chinese
Data Storage Capacity600,000 records
Power Supply90–260 VAC, 50/60 Hz
Optional24 VDC
OutputTwo isolated 4–20 mA analog outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for calcium concentration and temperature
Relay OutputOne multifunctional relay (cleaning trigger, periodic alarm, fault alert)
Enclosure RatingIP67-rated sealed housing
ElectrodeIntegrated BSENS740 calcium-selective composite electrode
CalibrationTwo-point calibration with standard solutions (e.g., 100 ppm & 1000 ppm Ca²⁺)
ComplianceDesigned per IEC 61000-6-2 (EMC immunity), IEC 61000-6-4 (EMC emission), and EN 61326-1 (laboratory & industrial measurement equipment)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Industrial Online ORP Meter
ModelPM 820 2P
Instrument TypeIndustrial Online ORP Analyzer
pH Range-2.00 to 16.00 pH
ORP Range-2000 to +2000 mV
Temperature Range0 to 130 °C
pH Resolution0.01 pH
ORP Resolution1 mV
Temperature Resolution0.1 °C
pH Accuracy±0.01 pH
ORP Accuracy±1 mV
Temp. Accuracy±0.1 °C
Temperature Compensation-10 to 130 °C (NTC10K / PT1000, manual or auto)
Operating Temp.-10 to 70.0 °C
Storage Temp.-20 to 70.0 °C
DisplayBacklit graphic LCD
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or 24 VDC (optional)
Analog Outputs2 isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS)
CommunicationRS485 Modbus RTU
Cleaning OutputAdjustable interval (0.1–1000 h), duration (1–1000 s)
Alarm Outputs2 independent Hi/Lo relays (5 A / 250 VAC / 30 VDC)
Enclosure RatingIP65
Mounting OptionsWall-mounted, pipe-mounted, panel-mounted
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRIMASCI
OriginShanghai, China
ModelinnoLab 10 C
PortabilityHandheld
Conductivity Range0–500 mS/cm
TDS Range0–500,000 ppm (as NaCl)
Resistivity Range0–100.0 MΩ·cm
Salinity Range0–325 ppt (Practical Salinity Scale)
Temperature Range−5 to +120 °C
Accuracy±1% F.S. (Conductivity), ±0.3 °C (Temperature)
Resolution0.001 µS/cm (low range), 0.01 mS/cm (high range), 0.1 °C
CalibrationAuto-ranging 1-point or manual multi-point (up to 3 points)
Temperature CompensationAutomatic/manual, −5 to +120 °C, selectable reference temp (15–30 °C, default 25 °C)
Electrode Constants0.01, 0.1, 1.0, 10.0 cm⁻¹
TDS Factor0.40–1.00 (adjustable)
Salinity Factor0.65 (PSS-78 compliant)
Memory Capacity100 data sets with timestamp
Display40 × 70 mm LCD, 120° viewing angle
IP RatingIP67
Power2 × AA alkaline batteries (>500 h operation)
Dimensions73 × 152 × 42 mm (W × L × H)
Weight250 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRIMA SCI (UK)
OriginShanghai, China
ModelinnoLab 10P
Instrument TypePortable
Parameter TypeSingle-Parameter (pH/ORP/Temp)
Measurement Range0.00–14.00 pH (extended: –2.00 to +16.00 pH), –2000 to +2000 mV, –5.0 to 120.0 °C
Resolution0.01 pH, 0.1 mV (±600.0 mV), 1 mV (full range), 0.1 °C/0.1 °F
Accuracy±0.01 pH, ±0.2 mV (±600.0 mV), ±1 mV (full range), ±0.3 °C / ±0.5 °F
CalibrationAuto-recognition of 1–3 point NIST-traceable buffer calibration
Temperature CompensationAutomatic (ATC) or Manual (MTC), –5.0 to +120.0 °C
Electrode InterfaceBNC + 3.5 mm temperature probe jack
Display43 × 70 mm LCD, 120° viewing angle
Housing RatingIP65
Dimensions73 × 152 × 42 mm (W × H × D)
Weight250 g
Power2 × 1.5 V AA alkaline batteries (>500 h operation)
Data StorageOptional 100-point memory
Auto-OffSelectable (10 min idle timeout)
Key FeaturesDifferential signal circuitry, electrode health diagnostics (Slope/Offset), STABLE reading indicator, MTC fallback mode, ergonomic grip, scratch-resistant display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Output Options4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min (configurable) or triggered by external/flow signal
Rinse Duration15–1800 s (user-configurable)
Sample Water RequirementspH 4–10
Environmental Operating Range10–40 °C
Compatible Units°dH, °f, ppm CaCO₃, mmol/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelPM8202I
PriceUpon Request
Measurement Range0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent)
Resolution0.01 / 0.1 / 1 ppm (user-selectable)
Accuracy±0.01 ppm (≤10 ppm), ±0.1 ppm (10–100 ppm), ±1 ppm (>100 ppm)
Temperature Compensation–10 to +130 °C (NTC30k or PT1000 sensor input, manual/automatic)
Operating Temperature–10 to +70.0 °C
Storage Temperature–20 to +70.0 °C
DisplayBacklit large-dot-matrix LCD
Language SupportEnglish & Chinese
Data Storage Capacity600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
Analog OutputsTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for Ca²⁺ concentration or temperature)
CommunicationRS485 Modbus RTU
Cleaning Cycle ControlInterval adjustable from 0.1 to 1000 h
Alarm OutputsTwo independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC), with user-defined hysteresis
Enclosure RatingIP65
Mounting OptionsWall-mount, pipe-mount, panel-mount
Dimensions (H×W×D)144 × 144 × 108 mm
Panel Cutout138 × 138 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPM8202I
Measurement Range0.00–20,000 ppm F⁻
Resolution0.0 / 0.1 / 1 ppm (selectable)
Accuracy±0.01 / ±0.1 / ±1 ppm (depending on range)
Temperature Compensation–10 to 130 °C (manual or automatic
Operating Temperature–10 to 70.0 °C
Storage Temperature–20 to 70.0 °C
DisplayBacklit large-dot-matrix LCD
LanguageEnglish & Chinese
Data Storage600,000 records
Power Supply90–260 VAC, 50/60 Hz or optional 24 VDC
OutputTwo isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for measured value or temperature
CommunicationRS485 Modbus RTU
Enclosure RatingIP67-rated sealed housing
Electrode CompatibilityBSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRIMASCI
OriginTaiwan
ModelinnoLab 20C
Form FactorBenchtop
Conductivity Range0–500 mS/cm
TDS Range0–500,000 ppm (as NaCl)
Resistivity Range0–18.30 MΩ·cm
Salinity Range0–325 ppt
Temperature Range−5 to +120 °C
Accuracy±0.5% of Full Scale
Minimum Resolution0.001 µS/cm (at lowest range)
Electrode Constants Supported0.01, 0.1, 1.0, 10.0 cm⁻¹
Temperature CompensationAutomatic or Manual (−5 to 120 °C), Reference Temp: 15–30 °C (default 25 °C)
TDS Conversion FactorAdjustable 0.40–1.00
Salinity Conversion FactorFixed 0.65
Data Storage100 measurement records
PowerAC 100–240 V + internal rechargeable Li-ion battery (1300 mAh)
Dimensions150 × 194 × 56 mm (W × L × H)
Weight1.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: GreenPrima
OriginSwitzerland
ModelPM8202P
Measurement Range0.00–14.00 pH, −2000 to +2000 mV, 0–130 °C
Resolution0.01 pH, 1 mV, 0.1 °C
Accuracy±0.01 pH, ±0.1 mV, ±0.1 °C
Calibration StandardNIST-traceable buffers
Temperature CompensationAutomatic/manual (NTC10k or PT1000)
OutputDual isolated 4–20 mA, RS485 Modbus RTU
Enclosure RatingIP65
Power Supply90–260 VAC / 50–60 Hz or 24 VDC option
MountingWall, panel, or pipe
Dimensions144 × 144 × 108 mm
Weight0.87 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelAqualysis 800A
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelPROCON3000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Output Options4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface
Input Options2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min (configurable) or triggered externally/flow-synchronized
Rinse Duration15–1800 s (user-configurable)
Sample Water RequirementspH 4–10
Environmental Operating Range10–40 °C
Units Supported°dH, °f, ppm CaCO₃, mmol/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAqualysis 800A
Measurement PrincipleTitrimetric Colorimetry
Measurement Time2–8 min (alkalinity-dependent)
Accuracy±2% of selected reagent upper limit
Repeatability±2% of selected reagent upper limit
Power Supply85–265 VAC, 47–63 Hz
Power Consumption25 VA (operational), 3.5 VA (standby)
Enclosure RatingIP65
Dimensions400 × 300 × 180 mm (H×W×D)
Weight4 kg
DisplayColor LCD
Measurable Units°dH, °f, ppm CaCO₃, mmol/L
Outputs4 programmable relay outputs (max. 250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485
Inputs2 programmable digital inputs (IN1: start analysis
IN2stop analysis)
Sampling Interval1–360 min, external trigger, or flow-signal synchronized
Rinse DurationConfigurable (15–1800 s)
Sample Water RequirementspH 4–10
Environmental Operating Temp.10–40 °C
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0