- All
- Favorite
- Popular
- Most rated
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Prosan 8200 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Turbidity |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit LCD, multi-line |
| Sample Pressure | 1–200 psi (built-in pressure regulator preset to 15 psi) |
| Operating Temperature | 1–50 °C |
| Mounting | Wall-mounted |
| Output Signals | Isolated 4–20 mA or RS-485 (MODBUS RTU protocol, optional) |
| Ingress Protection | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | HEYL (Neomeris) |
|---|---|
| Origin | Germany |
| Model | Testomat ECO / Testomat 2000 |
| Measurement Parameter | Total Calcium and Magnesium Hardness (as CaCO₃) |
| Power Supply | 230 V or 24 V ±10 %, 50–60 Hz |
| Power Consumption | ≤30 VA |
| Ingress Protection | IP65 |
| Electrical Safety Class | Class I |
| Compliance | EN 50081-1, EN 50082-2, EN 61010-1 |
| Operating Ambient Temperature | 10–45 °C |
| Sample Inlet Temperature | 10–40 °C |
| Operating Pressure Range | 0.1–3 bar (optional pressure regulator: 1–8 bar) |
| Dimensions (W×H×D) | 380 × 480 × 280 mm |
| Weight | ~9.5 kg |
| Display | Backlit LCD with text-based menu navigation |
| Output Signals | Two programmable relay outputs |
| Maintenance Alert Output | Yes |
| Analog Output | 4–20 mA |
| Mounting | Wall-mounted |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Measurement Principle | Colorimetric photometric analysis using EDTA-based titration chemistry |
| Optional Configurations | Dual-channel measurement (Testomat 2000 only) |
| Sampling Frequency Modes | Time-based interval, pulse-triggered (e.g., flow meter signal), volume-proportional, or factory preset cycle |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200I |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium Ion (Ca²⁺) |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | 0–70 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output Signals | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS), RS485 MODBUS RTU |
| Relay Output | 1 multifunctional relay (cleaning control, periodic alarm, fault alarm) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Electrode Model | Bsens740 |
| Electrode Range | 0–40,000 mg/L Ca²⁺ |
| Electrode Resolution | 0.01 mg/L |
| Electrode Accuracy | ±3% FS |
| Electrode Body Material | Polyphenylsulfone (PPS) |
| Electrode Max. Pressure | 3.5 bar |
| Electrode Connection | PG13.5 fixed thread |
| Electrode Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON 8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Calcium and Magnesium Hardness (as CaCO₃) |
| Output Interfaces | 4–20 mA analog output, RS485 digital communication |
| Operating Mode | Continuous or Interval Measurement |
| Wetted Materials | Chemically resistant (e.g., PTFE, PVDF, borosilicate glass, EPDM/FKM seals) |
| Display | Touchscreen HMI with bilingual (English/Chinese) interface |
| Reagent Delivery | Precision peristaltic metering pump |
| Brand | PRIMA (UK) |
|---|---|
| Origin | Taiwan |
| Model | innoLab 10D |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measured Parameters | Dissolved Oxygen (DO), mg/L and % Saturation |
| Measurement Range | 0.00–40.00 mg/L, 0.0–400.0% sat |
| Temperature | −5.0–120.0°C / 23.0–248.0°F |
| Resolution | 0.01 mg/L, 0.1% sat, 0.1°C/0.1°F |
| Accuracy | ±1.5% F.S. (DO), ±0.3°C / ±0.5°F (Temp) |
| Calibration | Manual 1-point or 2-point (air-saturated water or zero-oxygen solution) |
| Salinity Compensation | 0.0–45.0 ppt (manual input) |
| Atmospheric Pressure Compensation | 450–800 mmHg / 0.600–1.100 bar (manual input) |
| Depth Compensation | 0.0–10.0 m (liquid level) |
| Memory Capacity | 100 data sets |
| Auto Power-Off | After 10 min inactivity |
| Power Supply | 2 × AA batteries |
| Enclosure Rating | IP67 |
| Dimensions | 73 × 152 × 42 mm |
| Weight | 250 g |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic (China-made) |
| Model | TH7001 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium & Magnesium Hardness (as CaCO₃) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GP8200MAS |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, ORP, Free Chlorine, Turbidity, Dissolved Oxygen (DO), Electrical Conductivity (EC) |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Method | Titrimetric Colorimetry |
| Measurement Range | 0.447–625.8 ppm CaCO₃ |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD (bilingual: English/Chinese) |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Digital Inputs | 2 programmable (IN1: start analysis |
| IN2 | stop analysis) |
| Data Storage | Internal logging |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Ambient Temp. | 10–40 °C |
| Operating Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Compatible Reagents | TH7001, TH7003, TH7005, TH7010, TH7030, TH7050, TH7100 |
| Optional Multi-Channel Expansion | MCS series distributor (2–8 channels) |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | PROCON 8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Detection Principle | Automated Potentiometric Titration with Colorimetric Endpoint Detection |
| Output Signals | 4–20 mA analog output, RS485 Modbus RTU |
| Measurement Mode | Continuous or Programmable Interval Sampling |
| Enclosure Rating | IP65 |
| Wetted Materials | PTFE, PVDF, Borosilicate Glass, EPDM |
| Reagent Consumption | ≤1.2 mL per measurement cycle |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Operating Temperature | 5–45 °C |
| Storage Temperature | –20–60 °C |
| Dimensions (W×H×D) | 400 × 500 × 220 mm |
| Weight | 18 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8200I |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium Ion (Ca²⁺) |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0.00–20,000 ppm as CaCO₃ |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | -10–130 °C (NTC10K or PT1000 sensor, manual/automatic) |
| Operating Temperature | 0–70 °C |
| Storage Temperature | -20–70 °C |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS), RS485 MODBUS RTU |
| Relay Output | 1 multifunctional relay (cleaning, periodic alarm, fault alarm) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens740 |
| Sensor Range | 0–40,000 mg/L as CaCO₃ |
| Sensor Resolution | 0.01 mg/L |
| Sensor Accuracy | ±3% FS |
| Sensor Material | Polyphenylsulfone (PPS) |
| Sensor Max. Pressure | 3.5 bar |
| Sensor Connection | PG13.5 threaded fitting |
| Sensor Cable Length | 5 m |
| Brand | PRIMA |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20D |
| Instrument Type | Benchtop Dissolved Oxygen Analyzer |
| Measurement Range | 0.00–40.00 mg/L (ppm) and 0.0–400.0% saturation |
| Temperature Range | −5.0–120.0°C (23.0–248.0°F) |
| Resolution | 0.01 mg/L, 0.1%, 0.1°C/0.1°F |
| Accuracy | ±1.5% F.S. (DO), ±0.3°C (temperature) |
| Calibration | Manual 1-point or 2-point (air-saturated water / zero-oxygen solution) |
| Salinity Compensation | 0.0–45.0 ppt (manual input) |
| Atmospheric Pressure Compensation | 450–800 mmHg (0.600–1.100 bar) |
| Depth Compensation | 0.0–10.0 m (hydrostatic pressure correction) |
| Data Storage | 100 measurement records |
| Interface | USB (virtual COM port) |
| Power Supply | 100–240 VAC adapter |
| Battery | Built-in rechargeable Li-ion (for portable operation within benchtop form factor) |
| Enclosure Rating | IP54 |
| Dimensions | 150 × 194 × 56 mm |
| Weight | 1.0 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202P |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, ORP, Temperature |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | −10 to 130 °C (NTC10K or PT1000, manual/auto) |
| Operating Temperature | −10 to 70.0 °C |
| Storage Temperature | −20 to 70.0 °C |
| Display | Backlit dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS, configurable for pH/ORP/temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable cleaning interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, with hysteresis setting) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Aqualysis200SCD |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Streaming Current |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet/Outlet Connections | 1/2″ inlet, 3/4″ outlet |
| Response Time | 1 second |
| Auto-zero Calibration | Yes |
| Sensor Materials | Delrin housing, 316 stainless steel wetted parts, PTFE seals |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication Protocol | MODBUS RTU (optional) |
| Alarm Outputs | High/Low relay contacts |
| Enclosure Rating | IP65 |
| Dimensions | 230 × 330 mm (W × H) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 8 kg |
| Brand | PRIMA (UK) |
|---|---|
| Origin | Taiwan |
| Model | innoLab 10P |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Measured Parameters | pH, ORP (mV), Temperature |
| pH Range | -2.00 to 16.00 pH |
| ORP Range | -2000 to +2000 mV |
| Temperature Range | -5.0 to 120.0 °C |
| Resolution | 0.01 pH / 0.1 mV (±600.0 mV) / 0.1 °C |
| Accuracy | ±0.01 pH / ±0.2 mV (±600 mV), ±1 mV (full range) / ±0.3 °C |
| Temp. Compensation | Automatic or Manual |
| Calibration | Up to 5-point (NIST/USA buffers) |
| Memory | 100 data sets |
| Auto-Off | 10 min inactivity |
| Power | 2 × AA batteries |
| IP Rating | IP65 (pH mode), IP67 (conductivity/DO mode, not applicable here) |
| Dimensions | 73 × 152 × 42 mm |
| Weight | 250 g |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Output Signals | 4–20 mA, RS485 |
| Measurement Principle | Automated Potentiometric Titration with Colorimetric Endpoint Detection |
| Reagent Consumption | Low |
| Enclosure Rating | IP65 |
| Wetted Materials | PTFE, PVDF, EPDM, Borosilicate Glass |
| Operating Mode | Continuous or Interval Measurement |
| Display | 7-inch TFT Touchscreen with Multilingual UI (English/Chinese) |
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | SCD8200 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Streaming Current |
| Power Supply | 230 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Flow Rate | 1 L/min |
| Inlet/Outlet | 1/2″ and 3/4″ barbed fittings |
| Response Time | 1 s |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | Modbus (optional) |
| Alarm Outputs | Hi/Lo relay |
| Enclosure Rating | NEMA 4X, IP65 |
| Dimensions | 11″ × 6″ |
| Weight | 9 kg |
| Brand | PRIMASCI |
|---|---|
| Origin | Taiwan |
| Model | innoLab 10D |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measuring Parameter | Dissolved Oxygen (DO) |
| Measurement Range | 0.00–40.00 mg/L & 0–400.0% saturation |
| Resolution | 0.01 mg/L, 0.1%, 0.1 °C / 0.1 °F |
| Accuracy | ±1.5% of full scale, ±0.3 °C / ±0.5 °F |
| Temperature Compensation Range | 0.0–60.0 °C (auto/manual) |
| Calibration | 1- or 2-point automatic calibration |
| Salinity Compensation | 0.0–45.0 ppt |
| Atmospheric Pressure Compensation | 450–800 mmHg (0.600–1.100 bar) |
| Hydrostatic Pressure Compensation | 0.00–1.00 kg/cm² |
| Depth Compensation | 0.0–10.0 m |
| Data Storage | 100 measurement records |
| Auto Power-Off | Selectable (10 min inactivity) |
| Power Supply | 2 × 1.5 V AA batteries (>500 h operation) |
| Electrode Options | Clark-type polarographic or galvanic cell DO sensor |
| IP Rating | IP67 |
| Dimensions | 73 × 152 × 42 mm (W × L × H) |
| Weight | 250 g |
| (English product name follows international B2B naming convention | origin + function + model + device type) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Total Calcium & Magnesium Hardness (as CaCO₃) |
| Measurement Principle | DPD-based Colorimetric Titration |
| Accuracy | ±5% of selected reagent range upper limit |
| Repeatability | ±2.5% of selected reagent range upper limit |
| Dimensions | 300 × 300 × 200 mm (H × W × D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample pH Range | 4–10 |
| Interferent Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Measurement Cycle | Programmable interval (5–360 min), external trigger, or flow-pulse synchronized |
| Analysis Time | ~3 minutes (hardness-dependent) |
| Display | Graphical backlit LCD |
| Output Interfaces | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 0/4–20 mA analog output (750 Ω max), CAN bus interface |
| Digital Inputs | 2 programmable (IN1: analysis start / flow switch / pulse meter |
| IN2 | system reset) |
| Flushing Duration | Adjustable (15–1800 s) |
| Data Storage | SD card (event logs, fault records, measurement history) |
| Units | °dH, °f, ppm CaCO₃, mmol/L, mg/L, mval/L, °e |
| Mounting | Wall-mounted |
| Brand | PRIMA |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20C |
| Instrument Type | Benchtop Water Quality Analyzer |
| Measured Parameters | Conductivity, TDS, Salinity |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm and 0.01–0.1 mS/cm |
| Conductivity Accuracy | ±1% F.S. |
| Resistivity Range | 0–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C |
| Temperature Accuracy | ±0.3 °C |
| Auto Temperature Compensation (ATC) | Yes |
| Reference Temp | 15.0–30.0 °C (default 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (default 2.00%) |
| TDS Factor | 0.40–1.00 (default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Interface | USB |
| Power Supply | 100–240 VAC |
| IP Rating | IP54 |
| Dimensions | 150 × 194 × 56 mm |
| Weight | 1.0 kg |
| Data Storage | 100 measurement records |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200I |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium Ion (Ca²⁺) |
| Measurement Range | 0.00–20,000 ppm as CaCO₃ |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 sensor, manual/automatic) |
| Operating Temperature | 0–70 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output Signals | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS), RS485 MODBUS RTU |
| Relay Output | 1 multifunctional relay (for cleaning control, periodic alarm, fault alarm) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens740 |
| Sensor Range | 0–40,000 mg/L Ca²⁺ (as CaCO₃ equivalent) |
| Sensor Resolution | 0.01 mg/L |
| Sensor Accuracy | ±3% FS |
| Sensor Material | Polyphenylsulfone (PPS) |
| Sensor Max. Pressure | 3.5 bar |
| Connection | PG13.5 fixed thread |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Aqualysis 800 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Measurement Method | Titrimetric Colorimetry (Photometric Endpoint Detection) |
| Measurement Range | 0.447–625.8 ppm as CaCO₃ (configurable via reagent kits TH7001–TH7100) |
| Accuracy | ±2% of selected reagent’s upper limit |
| Repeatability | ±1% of selected reagent’s upper limit |
| Cycle Time | ~3 minutes (hardness-dependent) |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Dimensions | 400 × 300 × 180 mm (W×H×D) |
| Weight | 4 kg |
| Enclosure Rating | IP65 |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Outputs | 4 programmable relay contacts (250 VAC, 4 A), 1 isolated 4–20 mA analog output (max. 750 Ω), 1 RS485 Modbus RTU port |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Data Logging | Internal storage for time-stamped measurement records |
| Sample Requirements | pH 4–10 |
| Sample Temp. | 5–40 °C |
| Operating Ambient Temp. | 10–40 °C |
| Sample Pressure | 0.2–6 bar (recommended: 1–2 bar) |
| Mounting | Wall-mounted |
| Brand | PRIMA (UK) |
|---|---|
| Origin | Taiwan |
| Model | innoLab 10C |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | Conductivity, TDS, Salinity |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm, 0.01–0.1 mS/cm |
| Conductivity Accuracy | ±1% F.S. |
| Resistivity Range | 0–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C |
| Temperature Accuracy | ±0.3 °C |
| Auto Temperature Compensation (ATC) | Yes, reference temp 15.0–30.0 °C (default 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (default 2.00%) |
| TDS Factor | 0.40–1.00 (default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 100 readings |
| Display | Backlit LCD, 120° viewing angle |
| Power | 2 × AA batteries |
| Enclosure Rating | IP67 |
| Dimensions | 73 × 152 × 42 mm |
| Weight | 250 g |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON 8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Output Interfaces | 4–20 mA analog output, RS485 digital communication |
| Sample Contact Materials | Chemically resistant (e.g., PTFE, PVDF, borosilicate glass) |
| Measurement Mode | Continuous or programmable interval analysis |
| Reagent Consumption | Low-volume precision dosing via peristaltic metering pump |
| Display & Interface | Touchscreen HMI with bilingual (English/Chinese) menu system |
| Compliance | Designed for industrial process monitoring in accordance with ISO 9001 manufacturing standards |
| Brand | PRIMA (UK) |
|---|---|
| Origin | Taiwan |
| Model | innoLab 20I |
| Ion Measurement Range | 0.000–9999 mg/L |
| pH Range | −2.000–20.000 |
| mV Range | −2000.0–2000.0 |
| Temperature Range | −10.0–120.0 °C |
| pH Accuracy | ±0.2% F.S. ±3 LSD |
| mV Accuracy | ±0.1% F.S. ±3 LSD |
| Ion Accuracy | ±0.5% F.S. ±3 LSD |
| Calibration Points | up to 7-point ISE calibration |
| Memory Capacity | 1000 data sets (pH: 500, mV: 250, ION: 250) |
| Display | Backlit dot-matrix LCD |
| Interface | USB 2.0 |
| Power Supply | 100–240 VAC |
| Dimensions | 150 × 194 × 56 mm |
| Weight | 1.0 kg |
| Electrode Interface | BNC |
| Temperature Compensation | Automatic/Manual |
| ISE Compatibility | All standard liquid- and gel-filled ISEs (NH₄⁺, F⁻, Cl⁻, CN⁻, Na⁺, NO₃⁻, K⁺, Ca²⁺, Cu²⁺, Pb²⁺, Ag⁺, etc.) |
Show next