| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SCD-8200 |
| Price | Upon Request |
| Power Supply | 100–240 VAC |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Response Time | 1 second |
| Flow Rate | 1 L/min |
| Inlet Connection | 1/2" barbed |
| Outlet Connection | 3/4" barbed |
| Enclosure Rating | IP65, NEMA 4X non-metallic |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication | Optional MODBUS RTU |
| Alarm Outputs | High/Low relay |
| Sensor Materials | Delrin, 316 stainless steel, PTFE |
| Diagnostic LED | Integrated on sensor head |
| Weight | 9 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202I |
| Pricing | Available Upon Request |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (scale-dependent) |
| Temperature Compensation | -10 to 130 °C (manual or automatic |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD with bilingual (English/Chinese) interface |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed against dust and water ingress) |
| Electrode Compatibility | BSens710 Fluoride ISE, BSens720 Chloride ISE, BSens730 Ammonia ISE |
| Calibration | Manual or scheduled two-point calibration with password-protected access |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Measurement Principle | Acid-Base Titration with Photometric Endpoint Detection |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 180 mm |
| Weight | 4 kg |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Output Interfaces | 4 programmable relay outputs (max. 250 V, 4 A) |
| Input Interfaces | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample Water Quality Requirements | pH 4–10 |
| Flush Duration | Configurable (15–1800 s) |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | PM8200I |
| Pricing | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual/automatic |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit dot-matrix LCD with pH, temperature, time, and relay status |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485, MODBUS RTU protocol compliant |
| Relay Output | 1 multifunctional relay (for cleaning cycle activation, periodic alarm, fault indication) |
| Data Logging | 600,000 records with timestamped retrieval |
| Enclosure | Fully sealed IP65-rated housing (PPS-coated aluminum alloy & engineering plastics) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Electrode Model | Bsens740 |
| Electrode Range | 0–40,000 mg/L as CaCO₃ |
| Electrode Resolution | 0.01 mg/L |
| Electrode Accuracy | ±3% FS |
| Electrode Body Material | Polyphenylsulfone (PPS) |
| Electrode Operating Temp. | –5 to 70.0 °C |
| Max. Pressure Rating | 3.5 bar |
| Connection | PG13.5 threaded gland |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Aqualysis 800 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON2000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | USD 1 (Reference Only) |
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Prosan 8200 |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (user-adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit multi-line LCD |
| Sample Pressure | 1–200 psi (integrated pressure regulator preset to 15 psi) |
| Operating Temperature | 1–50 °C |
| Mounting | Wall-mounted |
| Output Signals | Isolated 4–20 mA and/or RS-485 with MODBUS RTU protocol |
| Ingress Protection | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Power Supply | 100–240 VAC |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON 5000 |
| Price | USD 1 (FOB) |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (range-dependent) |
| Temperature Compensation | -10–130 °C (NTC30K or PT1000 sensor, manual/automatic) |
| Operating Temperature | -10–70.0 °C |
| Storage Temperature | -20–70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS), RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, waterproof and gas-tight) |
| Calibration | Manual or scheduled two-point calibration using standard solutions |
| Security | Password-protected configuration interface |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | AquaLysis 800PA |
| Measurement Method | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD with Chinese/English interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Output | 4 programmable relay outputs (250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Input | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sample Flow Pressure | 0.2–5 bar (recommended: 1–2 bar) |
| Sample Temperature | 5–40 °C |
| Ambient Temperature | 10–40 °C |
| Sample pH Range | 4–10 |
| Interference Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Rinse Time Programmable | 15–1800 s |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (dependent on range) |
| Temperature Compensation | −10 to +130 °C (manual or automatic |
| Operating Temperature | −10 to +70.0 °C |
| Storage Temperature | −20 to +70.0 °C |
| Display | Backlit large-dot-matrix LCD with real-time concentration, temperature, timestamp, and relay status |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay alarms with hysteresis setting (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualys is800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202I |
| Pricing | Available Upon Request |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit high-contrast dot-matrix LCD |
| Languages | English & Chinese interface |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output Signals | Two isolated 4–20 mA analog outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Enclosure Rating | IP66/IP67 (fully sealed, dust-tight and water-resistant) |
| Electrode Compatibility | BSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N) |
| Calibration | Manual or scheduled automatic calibration support |
| Security | Password-protected configuration and operation |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200I |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (dependent on range) |
| Temperature Compensation | −10 to +130 °C (NTC30K or PT1000 sensor input, manual/automatic) |
| Operating Temperature | −10 to +70.0 °C |
| Storage Temperature | −20 to +70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS, configurable for concentration or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, programmable hysteresis) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PM8200I |
| Pricing | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 sensor, manual/automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit graphical LCD |
| Data Storage | 600,000 records |
| Communication | RS485 MODBUS RTU |
| Analog Outputs | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) |
| Relay Output | 1 multifunctional relay (cleaning, periodic alarm, fault alarm) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens740 |
| Sensor Range | 0–40,000 mg/L as CaCO₃ |
| Sensor Resolution | 0.01 mg/L |
| Sensor Accuracy | ±3% FS |
| Sensor Material | Polyphenylsulfone (PPS) |
| Sensor Max. Pressure | 3.5 bar |
| Sensor Connection | PG13.5 threaded fitting |
| Sensor Cable Length | 5 m |