Empowering Scientific Discovery

GOP Instruments (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCO N7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-extractive, Immersion-style Sensor)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Temp.1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Ambient Temp.1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61000-4 (Overvoltage Category II)
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPROCON7000
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Environmental Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Sample Temperature Range1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Enclosure RatingIP55
Electrical SafetyCompliant with EN 61010-1 and IEC 664 Category II
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON N7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel touch screen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Dimensions (H×W×D)215 × 242 × 73 mm
Weight2.25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPROCON 7000
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence-based Hydrocarbon Detection (UV-Excited Emission)
Measurement Range0–99 ppm (as hydrocarbon equivalent)
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel TFT touchscreen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Dimensions (H×W×D)215 × 242 × 73 mm
Weight2.25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPRO CON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-extractive, In-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm 1 Delay0–60 s (adjustable)
Alarm 2 Delay10–240 s (adjustable)
Display240×128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Temp.1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Ambient Temp.1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61010-1, Overvoltage Category II
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Dimensions (H×W×D)215 × 242 × 73 mm
Weight2.25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPROCON7000
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Environmental Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Sample Temperature1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Enclosure RatingIP55
Electrical SafetyComplies with EN 61010-1 and IEC 61000-6-2/6-4 (Overvoltage Category II)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOMD-24 / OMD-15
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (IMO MEPC.107(49)-compliant)
Measurement Range0–30 ppm (trending up to 50 ppm), IMO-compliant range: 0–15 ppm
Detection Limit< 2% of full scale
Accuracy±1% FS
Resolution0.1 ppm
Measurement FrequencyUser-adjustable
Linearity±2% FS
Power Supply24 V AC/DC ±10%
Power Consumption< 10 VA
Sample Flow Rate0.1–4 L/min
Sample Temperature Range+1 °C to +65 °C
Process ConnectionR ¼" internal thread
Alarm SetpointsTwo independent, adjustable within 1–15 ppm (default: 15 ppm)
Alarm Delay (Point 1)1–540 s (default: 2 s)
Control Delay (Point 2)1–20 s (default: 10 s)
Relay OutputPassive, 3 A / 240 V AC/DC
Analog Output4–20 mA, max. load < 150 Ω
DisplayGraphical LCD
Ambient Operating Temperature+1 °C to +55 °C
Enclosure RatingIP65
Dimensions (Control Unit)185 × 210 × 65 mm (W×H×D)
Dimensions (Measurement Cell)140 × 160 × 65 mm (W×H×D)
Weight2.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCO N7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based optical detection (non-extractive, in-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Power Consumption≤10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPR-OCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Temperature1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROC ON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Detection (Non-Extractive, UV-Excited)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240×128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61000-6-2, Overvoltage Category II
Power Supply230 V / 115 V AC or 24 V AC
Power Consumption≤10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (Adjustable)
Alarm Delay 10–60 s (Adjustable)
Alarm Delay 210–240 s (Adjustable)
Display240×128 Pixel Touchscreen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61010-1, Overvoltage Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON 7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240×128 pixel touch screen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCO N70 00
Instrument TypeOnline
Measurement PrincipleFluorescence-based optical detection (non-extractive, in-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUK
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPR OCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based optical detection (non-extractive, in-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Temperature1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPR OCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence Spectrophotometry
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel touchscreen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Ambient Temperature1–60 °C
Relative Humiditymax. 90 % RH at 55 °C
Sample Temperature1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Enclosure RatingIP55
Electrical Installation Overvoltage CategoryEN 61010-1 / IEC 664 Category II
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240×128 pixel touchscreen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61000-4 (Overvoltage Category II)
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Dimensions (H×W×D)215 × 242 × 73 mm
Weight2.25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPROCON7000
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel TFT touchscreen
Output Signals0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61000-6-2 & -6-3, Overvoltage Category II
Power Supply230 V / 115 V AC or 24 V AC, Max. 10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPRO CON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Temperature1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPROCON7000
Instrument TypeOnline Analyzer
Measurement PrincipleInfrared Spectrophotometry (IR)
Measurement Range1–99 ppm
Detection Limit1 ppm
Accuracy±2 ppm
Resolution1 ppm
Measurement FrequencyReal-time
Display240 × 128 pixel touchscreen
Output Signals0–20 mA, 4–20 mA (min. load 820 Ω), 0–5 V DC, 1–5 V DC (min. load 50 kΩ)
Ambient Temperature Range1–60 °C
Relative Humidity≤90 % RH at 55 °C
Sample Temperature Range1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure Range0.1–10 bar
Weight2.25 kg
Dimensions (W × H × D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Enclosure RatingIP55
Electrical Safety ComplianceEN 61010-1 / IEC 61000-4 (Overvoltage Category II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON 7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based optical detection (non-extractive, in-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm Delay 10–60 s (adjustable)
Alarm Delay 210–240 s (adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Temperature1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1, IEC 664 Category II
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPROCON7000
Instrument TypeOnline
Measurement PrincipleFluorescence-based optical detection (non-extractive, in-situ)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm 1 Delay0–60 s (adjustable)
Alarm 2 Delay10–240 s (adjustable)
Display240 × 128 pixel touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Temp.1–40 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Ambient Temp.1–60 °C
Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61000-4 (Overvoltage Category II)
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Power Supply230 V / 115 V AC or 24 V AC
Max. Power Consumption10 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGreenPrima
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelPROCON7000
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence-based Optical Detection (Non-Extractive, Solvent-Free)
Measurement Range0–99 ppm
Accuracy±2 ppm
Alarm Setpoint Range1–98 ppm (adjustable)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s (both adjustable)
Display240 × 128 pixel resistive touchscreen
Analog Outputs0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ)
Sample Flow Rate0.1–2 L/min
Sample Temperature1–40 °C
Sample Pressure0.1–10 bar
Ambient Operating Temperature1–60 °C
Relative Humidity≤90% RH at 55 °C
Enclosure RatingIP55
Electrical SafetyEN 61010-1 / IEC 61010-1, Overvoltage Category II
Power Supply230 V AC / 115 V AC or 24 V AC, max. 10 VA
Weight2.25 kg
Dimensions (H×W×D)215 × 242 × 73 mm
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0