BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose with Pesticide Residue Focus
Temperature Control Zones6 independent zones (including column oven, injector, detector, AUX1–AUX3)
Column Oven Temp Range+7 °C to 420 °C
Programmed Temperature Ramping5-step linear ramping
Injector Max Temp420 °C
Carrier Gas Pressure ControlElectronic pressure control (EPC) compatible
Carrier Gas Flow ControlMass flow controller (MFC) optional
Detector CompatibilityFID, TCD, FPD, NPD, ECD (up to 3 simultaneously)
Injection ModesSplit/splitless, on-column, packed-column vaporizing, WBC for wide-bore capillary, 6-port gas sampling valve
Safety ProtectionsOver-temperature, over-current (TCD), and system crash protection circuits
Data InterfaceRS-232 or USB (legacy PC connectivity)
ComplianceDesigned to support GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelGC1690 for DME in Fuels
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose with DME-Specific Configuration
Temperature Control Range+7 °C to 420 °C
Programmable Ramp Stages5-step oven temperature programming
Carrier Gas Flow ControlExternal modular flow controller (capillary/twin-channel configuration)
Carrier Gas Pressure ControlAdjustable via external pressure regulator
Injector Maximum Operating Temperature≤420 °C
Injector Pressure Setting Range0–100 psi (adjustable)
Total Injector Flow Range0–100 mL/min (carrier + makeup gases)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose with Baijiu (Chinese Liquor) Analysis Optimization
Temperature Control Zones6 Independent Channels (including Column Oven, Injector, Detector, AUX1–AUX3)
Column Oven Temp Range+7 °C to 420 °C
Programmed Ramp Stages5-Stage Linear/Nonlinear
Oven Cooling RateAmbient air-cooled with motorized auto-backdoor
Carrier Gas ControlExternal modular gas control boxes (capillary, carrier, fuel/oxidant circuits) with manual flow/pressure adjustment
Injector Max Temp450 °C
Injector Pressure Range0–100 psi (adjustable)
Total Injector Flow Range0–200 mL/min
Detector CompatibilityUp to three simultaneous detectors (FID, TCD, FPD, NPD, ECD)
Safety ProtectionsOver-Temperature, Over-Current (TCD), and System Crash Protection
DisplayBacklit LCD with color-coded membrane keyboard (green = temp, blue = detector, white = numeric, black = event)
Physical DesignVertical column oven
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLC-1280 Series
Price RangeUSD 14,000–28,000
Instrument TypeConventional HPLC System
Application ScopeGeneral-Purpose Analytical Use
Flow Rate Range0.001–10.000 mL/min (0.001 mL/min increment)
Maximum Pressure9000 psi
Flow Accuracy±0.2% RSD
Injection VolumeStandard 100 µL (Optional: 10, 20, 50 µL)
Sample Tray CapacityDual 48-position vial racks (Optional: 96-well and 384-well plate compatibility)
Column Oven Temperature Range+5 °C to 70 °C above ambient
UV-Vis Wavelength Range190–800 nm
Data Acquisition Rate100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopePower Industry SF₆ & Insulating Gas Analysis
Temperature Control Zones6 (including column oven, injector, detector, AUX1–AUX3)
Column Oven Temp Range+7 °C to 420 °C
Programmed Ramp5-step ramp capability
Oven CoolingForced-air active cooling with auto rear door opening
Carrier Gas ControlExternal modular gas control boxes (capillary, carrier, fuel/oxidant circuits)
Injector Max Temp420 °C
Injector Pressure Range0–100 psi (adjustable)
Injector Total Flow Range0–100 mL/min
Detector CompatibilityFID, TCD, FPD, NPD, ECD (up to 3 simultaneously)
Safety ProtectionsOver-temperature, over-current (TCD), and system crash protection circuits
ComplianceDesigned for GLP-compliant operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Gas Chromatograph
ApplicationEO Residue Quantification in Medical Devices
Temperature Control RangeUp to 400 °C (Oven), 200 °C (Injector), 250 °C (Detector)
Heating Rate0.1–40 °C/min (programmable)
Cooling RateAmbient cooling with forced air assist
Carrier Gas Flow ControlDigital electronic pressure/flow control (EPC) for N₂, H₂, Air
Carrier Gas Pressure Range0–100 psi
Injector Max Temp200 °C
Injector Pressure Setting Range0–100 psi
Total Injector Flow Range0–100 mL/min
Compliance StandardAligned with GB/T 14233.1–2008, ISO 10993-7, USP <88>, ASTM F2889
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
ModelGC1690
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose analysis of organic/inorganic compounds and gases (boiling point ≤ 399 °C)
Temperature Control Zones6 independent zones (including column oven, injector, detector, AUX1)
Column Oven Temp Range+7 °C to 420 °C
Programmed Ramp5-step programmable heating
Injector Max Temp420 °C
Carrier Gas Pressure ControlExternal modular pressure controllers (single/dual channel)
Carrier Gas Flow ControlExternal modular flow controllers (single/dual channel)
Detector OptionsFID, TCD, FPD, NPD, ECD (up to three simultaneously installed)
Injection ModesPacked-column on-column, split/splitless, wide-bore capillary (WBC), packed-column vaporizing, 6-port gas sampling valve
Safety ProtectionsOver-temperature, over-current (TCD), and system crash protection with automatic power cutoff and audible/visual alarm
Data InterfaceRS-232 or USB (optional)
ComplianceDesigned for GLP-compliant laboratory environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao/Kexiao
OriginZhejiang, China
ModelGC1690 NMHC
Instrument TypeLaboratory Gas Chromatograph
Application ScopeEnvironmental Air & Exhaust Monitoring
Detection PrincipleDual-Packed-Column Parallel Separation with Single FID Detection
Minimum Detectable Concentration0.05 mg/m³ (as methane equivalent)
Regulatory ComplianceGB 16297–1996, “Methods for Monitoring and Analysis of Air and Waste Gas” (4th Ed.)
Sample Introduction10-Port Valving System with 1 mL Gas Loop
Column ConfigurationTwo Parallel Packed Columns (Total Hydrocarbons Column + Methane-Specific Column)
DetectorFlame Ionization Detector (FID), 150 °C Operating Temperature
Injector Temperature150 °C
Oven Temperature RangeAmbient to 300 °C (programmable)
Carrier GasHigh-Purity Nitrogen or Helium
Flow ControlMechanical or Electronic Pressure/Flow Regulation (model-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGC1690 for Mixed Inorganic & Organic Gases
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range+7 °C to 420 °C (Column Oven)
Programmable Ramp Rate5-Stage Programmed Temperature Ramping
Carrier Gas Flow ControlExternal Modular Flow Controller (Capillary, Carrier, Fuel/Auxiliary Gas Boxes)
Carrier Gas Pressure ControlElectronic Pressure Control (EPC)-Compatible Design
Injector Maximum Operating Temperature≤420 °C
Injector Pressure Setting Range0–100 psi (adjustable)
Total Injector Flow Setting Range0–500 mL/min (dependent on configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose with H₂ production process gas analysis focus
Temperature Control Zones6 independent zones (including column oven, injector, detector, AUX1)
Column Oven Temp Range+7 °C to 420 °C
Programmed Ramp5-step temperature programming
Injector Max Temp≤420 °C
Carrier Gas Pressure ControlExternal modular pressure controllers (dual-channel optional)
Carrier Gas Flow ControlExternal modular mass flow controllers (dual-channel optional)
Detector CompatibilityFID, TCD, FPD, NPD, ECD (up to three simultaneously)
Injection ModesPacked-column on-column, split/splitless, wide-bore capillary (WBC), packed-column vaporizing, 6-port gas sampling valve
Safety ProtectionsOver-temperature, over-current (TCD-specific), and system crash auto-shutdown with audible/visual alarm
Column Oven ArchitectureVertical design with active rear-door cooling
DisplayBacklit LCD with color-coded membrane keyboard (green = temp, blue = detector, white = numeric, black = event control)
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application FocusIndoor Air VOC Analysis
Temperature Control Zones6 (including column oven, injector, detector, AUX1–AUX3)
Column Oven Temp Range+7 °C to 420 °C
Programmable Ramp Stages5-step linear heating
Oven CoolingAmbient air-cooled with motorized rear door
Carrier Gas ControlExternal modular gas control boxes (capillary, carrier, fuel/oxidant circuits)
Injector OptionsSplit/splitless, on-column, packed-column vaporizing, WBC for wide-bore capillaries, 6-port gas sampling valve
Detector CompatibilityUp to three simultaneous detectors (FID, TCD, FPD, NPD, ECD)
Safety ProtectionsOver-temperature cutoff, TCD over-current protection, system-level hardware watchdog and power-fail recovery