- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration | Standalone Detectors for HPLC Systems |
| Model Designation | 1100/1200 FLR Detector (G1321A/G1321B) and 1200 RID (G1362A) |
| Compliance | Fully Tested per Agilent Functional Specifications |
| Condition | Professionally Refurbished, Factory-Calibrated, Ready for GLP-Compliant Operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-40X3B |
| Category | Liquid Chromatograph (HPLC/UHPLC) |
| Configuration | LC Front-End for LC-MS Coupling |
| Warranty | 12 months |
| Compliance | Designed for ISO/IEC 17025, GLP, and FDA 21 CFR Part 11–ready workflows |
| Software Platform | LabSolutions LCMS v5.1 or later |
| Power Consumption (Standby) | ≤68% reduction vs. prior generation |
| Auto-sampler Injection Speed | ≤5 sec per injection |
| Carryover | <0.001% (typical, validated with caffeine/benzodiazepine test mixtures) |
| Sample Capacity | Up to 44 × 96-well MTP plates via optional Plate Changer |
| Dual-Independent Flow Path Support | Yes (via SIL-40CX dual-inlet configuration) |
| Temperature Control | Active airflow management in sample compartment (±0.5 °C stability, condensation-suppressed) |
| Brand | SEDEX (by S.E. Industries) |
|---|---|
| Origin | France |
| Model | ELSD-LT / ELSD-LT II / ELSD-LT III (Sedex 75/85/100) |
| Light Source | LED (470 nm) |
| Detector | High-sensitivity photomultiplier tube with digital signal processing |
| Detection Limit | 100 pg (C12EO8, micro-HPLC) |
| Typical Quantitation Range | 0.5–5 µg |
| Evaporation Temperature Range | Ambient to 100 °C (1 °C resolution) |
| Flow Rate Compatibility | 100 µL/min – 5 mL/min |
| Nebulizer Options | 4 types (HPLC, CC, Micro, UPLC) |
| Carrier Gas Consumption | <3.0 L/min |
| Required Gas Supply | N₂ or clean dry air, ≥5 L/min at 2–4.5 bar |
| Baseline Noise | <1 mV/h (aqueous), <3 mV/h (non-aqueous, GAIN-dependent) |
| Signal Output | 0–1 V analog |
| Gain Setting | 1–12 (2048-point digital resolution) |
| Data Acquisition Rate | 100 Hz |
| Interface | RS-232 |
| Software Control | Optional full-parameter programming (Agilent-compatible drivers available) |
| GLP Compliance Features | Audit trail, user authentication, parameter locking |
| Dimensions | 250 × 480 × 550 mm |
| Weight | 18.5 kg |
| Power | 230 V / 50 Hz / 1.7 A |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 7300DV |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Warranty | 1 Year |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D |
| Sample Introduction System | GemCone™ Nebulizer with Sapphire Tip & Corrosion-Resistant Polymer Spray Chamber |
| RF Generator | 40.68 MHz Solid-State Self-Oscillating Design |
| Optical System | Dual-Path UV/Vis Spectrometer with Echelle Grating (80 × 160 mm), 75 mm Collimating Mirror |
| Detector | SCD (Solid-State Charge-Detector) Array |
| Detection Limits | <1 ppt for most metals |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | SIL-10AF |
| Type | Liquid Chromatography Autosampler |
| Condition | Refurbished |
| Compliance | Designed for Shimadzu LC Systems (e.g., LC-10AT, LC-10AVP) |
| Interface | Standard RS-232C / TTL control signals |
| Sample Capacity | Up to 100 × 1.5 mL vials (with optional tray) |
| Injection Volume Range | 1–100 µL (adjustable in 0.1 µL increments) |
| Precision | RSD ≤ 0.5% (at 10 µL injection) |
| Carryover | < 0.01% (with standard wash protocol) |
| Cycle Time | ≤ 25 s (including needle wash and injection) |
| Power Supply | 100–120 V AC, 50/60 Hz |
| Operating Environment | 15–35 °C, 30–80% RH (non-condensing) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1200 (Binary/Quaternary) |
| Flow Rate Range | 0.001–10 mL/min |
| Gradient Delay Volume | 120 µL (low-volume) / 600–1100 µL (standard) |
| Detector Compatibility | DAD-SL, VWD, MWD-SL, FLR, RID |
| Software Control | Agilent ChemStation, EZChrom, Instant Pilot |
| Degasser | Integrated Micro-Vacuum Degasser (He-free operation) |
| Maintenance | Front-panel accessible modules |
| Diagnostics | Built-in self-test, EMF (Early Maintenance Feedback), event logging |
| Regulatory Compliance | Designed for GLP/GMP environments with audit-trail-capable software options (e.g., ChemStation with 21 CFR Part 11 compliance package) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model(s) | LC-20AB, LC-20AD, LC-30AD |
| System Controller | CBM-20A or CBM-20A Lite |
| Pump Type | Parallel dual-plunger (LC-20AB/LC-20AD) or series dual-plunger (LC-20AT) |
| Max Pressure | 40 MPa |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Flow Accuracy | ±1% or ±2 µL/min (whichever greater) |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD |
| Gradient Modes | High-pressure (2–3 solvents) or low-pressure (4 solvents) |
| UV-Vis Detector SPD-20A/SPD-20AV | Wavelength Range 190–700 nm (SPD-20A) or 190–900 nm (SPD-20AV), Wavelength Accuracy <1 nm, Noise ±0.25×10⁻⁵ AU |
| PDA Detector SPD-M20A | 512-diode array, 190–800 nm, Noise ±0.3×10⁻⁵ AU |
| Autosampler SIL-20A/SIL-20AC | Sample Capacity up to 768 (384-well MTP ×2), Injection Volume 0.1–100 µL (standard), Cooling Range 4–40 °C (SIL-20AC) |
| Column Oven CTO-20A/CTO-20AC | Temp Control Range (RT +10) to 85 °C (CTO-20A) or (RT −10) to 85 °C (CTO-20AC), Stability ≤0.04 °C (typ.) |
| Data Handling | 24-hr buffer (500 ms sampling, LCsolution only) |
| Warranty | 12 months |
| Operational Age | 5–10 years |
| Compliance | Designed for ASTM D4294, USP <621>, ISO 17025-aligned operation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration | Binary High-Pressure Pump (G4220A), Autosampler (G4226A) with Thermostatted Tray (G1330B), High-Capacity Column Compartment (G1316C, MCT, −20 °C to 110 °C), DAD (G4212A), VWD (G7114B) |
| Maximum System Pressure | 1300 bar |
| Gradient Delay Volume | < 100 µL |
| DAD Sampling Rate | Up to 240 Hz |
| Baseline Noise (DAD, 60-mm flow cell) | ±0.6 µAU/cm |
| Column Capacity | Up to 8 columns |
| Sample Capacity | Up to 6144 vials (with optional stack expansion) |
| Compliance | ASTM D5503, ISO 17025, USP <621>, FDA 21 CFR Part 11 (when operated with compliant CDS) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration Options | 1260 Dual-Gradient High-Pressure Pump / 1260 Infinity II Quaternary Low-Pressure Pump |
| Maximum Pressure | 600 bar |
| Flow Rate Range | 0.05–5 mL/min at 600 bar |
| Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Column Oven Temperature Range | –10 °C to 80 °C (up to 100 °C with optional 1290 Infinity Column Compartment) |
| Temperature Stability | < ±0.15 °C |
| UV Detector Data Acquisition Rate | 80 Hz (DAD, 60 mm flow cell) |
| Baseline Noise | ≤ 0.6 µAU/cm |
| Detection Options | UV/Vis DAD, Fluorescence, ELSD |
| Compliance Features | EMF (Early Maintenance Feedback), RFID-enabled consumables tracking (lamp, flow cell), Data Recovery Card (DRC), GLP/GMP-ready audit trail support via OpenLab CDS |
| Warranty | 12 months |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | CTO-10AVP |
| Type | HPLC Column Oven |
| Condition | Refurbished |
| Warranty | Not Applicable |
| Compliance | Designed for Shimadzu LC Systems (e.g., LC-10AT, SPD-10A, SCL-10A) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Vanquish VC-P21-A-01 |
| Category | Liquid Chromatograph (UHPLC) |
| Pump Type | Quaternary Solvent Manager |
| Maximum Pressure | 1500 bar |
| Flow Rate Range | 0.001–5.000 mL/min |
| Solvent Channels | 6 (2×3 configuration) |
| Column Oven Temperature Range | 5–120 °C |
| Detector | Diode Array Detector (DAD) with LightPipe™ Technology |
| Software | Dionex Chromeleon CDS v7.3 or later |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP-supportive audit trail, ASTM D7941, ISO 17025 applicable |
| Warranty | 12 months limited hardware warranty |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010CHT |
| Pump | Serial dual-plunger micro-pump (10 µL primary, 5 µL secondary) |
| Flow rate range | 0.001–5.0 mL/min (at 1.0–35.0 MPa) |
| Flow precision | ≤0.075% RSD (0.05–2.0 mL/min, methanol, 20 °C) |
| Low-pressure gradient elution | Up to 4 solvents, 0.1% increment |
| Autosampler injection volume | 0.1–100 µL |
| Injection repeatability | ≤0.3% RSD (10 µL) |
| Column oven temp. range | (ambient −15) to 60 °C, stability ±0.1 °C |
| UV-Vis detector | Deuterium lamp, 190–600 nm, wavelength accuracy ±1 nm, wavelength reproducibility ±0.1 nm, drift ≤1×10⁻⁴ AU/h (250 nm), S/N ≥0.25×10⁻⁵ AU (1 s response, air cell) |
| Dimensions (W×D×H) | 430 × 500 × 605 mm |
| Weight | 52 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-20AD XR |
| Category | Liquid Chromatography Pump System (HPLC, LC-MS Compatible) |
| Flow Accuracy | ≤ ±0.3% (RSD < 0.1% at 20°C) |
| Injection Speed | ≤ 10 s for 10 µL |
| Warranty | 12 months |
| Compliance | Designed for ISO/IEC 17025 and GLP-compliant laboratories |
| Software Interface | Native compatibility with Shimadzu LabSolutions LCMS and Class LC-10/20 series drivers |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | CBM-20 Alite System Controller |
| Category | Networked HPLC System Controller |
| Condition | Refurbished |
| Warranty | Not Included |
| Compliance | Designed for Shimadzu LC-10/20/VP Series and Prominence Systems |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | PC-55N |
| Compatible Controller | CBM-20A |
| Category | LC System Peripheral Board |
| Warranty | None |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2040 |
| Maximum System Pressure | 66 MPa (9,500 psi) |
| Column Compatibility | Sub-2.5 µm and Core-Shell Packings |
| Detector | UV-Vis (Standard), Optional PDA or Fluorescence |
| Autosampler Injection Volume Range | 0.1–100 µL |
| Carryover | ≤0.0025% |
| Temperature Control | Dual-zone (Optics & Flow Cell) |
| Data System | LabSolutions v5.9+ with ICM (Interactive Communication Mode) |
| Compliance | FDA 21 CFR Part 11 Ready (Audit Trail, Electronic Signatures), GLP/GMP Support Enabled |
| Warranty | 12 Months Comprehensive Coverage |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2030 Plus |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum Pressure | 44 MPa |
| Autosampler Capacity | 216 positions (1.5 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient −10) to 85 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Warranty | 1 year |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-30AD |
| Category | Liquid Chromatography Pump (HPLC Solvent Delivery Module) |
| Maximum Pressure | 130 MPa |
| Flow Rate Range | 0–3 mL/min |
| Flow Precision | ≤0.06% RSD |
| Flow Resolution | 3 nL/min |
| Compliance | Designed for LC-MS interface applications |
| Warranty | 12 months limited warranty |
| Configuration | Single or dual pump module, refurbished and functionally validated |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7400 DUO |
| Instrument Age | 9 years |
| Warranty | 1 year |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry |
| Regulatory Compliance | Designed to support ASTM D5185, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Dual-View Configuration | Radial and Axial Simultaneous Viewing |
| RF Generator | Solid-State, 27.12 MHz, 1.5 kW |
| Nebulizer | Glass concentric or SeaSpray™ high-salt nebulizer (configurable) |
| Detector | Advanced solid-state CCD array with thermoelectric cooling |
| Resolution | ≤0.007 nm at 200 nm |
| Detection Limits | Sub-ppt to low-ppt range for most elements (e.g., 0.04 ng/mL for Mg II 280.270 nm, axial view) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | LC-1100 (Quaternary or Binary Pump) |
| Product Category | Chromatography System |
| Operational Age | >7 years |
| Warranty | 1 year |
| Pump Types Supported | Quaternary Pump, Binary Pump |
| Flow Rate Range (Quaternary) | 0.001–10 mL/min |
| Flow Rate Range (Binary) | 0.001–5 mL/min |
| Autosampler Capacity | Up to 100 × 2 mL vials or 2 × 96-well plates |
| Detection Options | VWD (190–600 nm), MWD (190–950 nm), DAD (190–950 nm), FLD, RID, ECD, MSD (LC/MS) |
| Column Oven Temp Range | 10 °C below ambient to 80 °C |
| Degasser | Integrated vacuum-based online degassing unit |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2060 |
| Configuration | Integrated HPLC System |
| Warranty | 1 Year |
| Category | Chromatography Instruments |
| Condition | Refurbished & Fully Qualified |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2050 |
| Configuration | Integrated HPLC System |
| Warranty | 1 Year |
| Category | Chromatography Instrument |
| Compliance | ASTM D7493, USP <621>, EP 2.2.46, ISO/IEC 17025-aligned operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexera LC-40D |
| Instrument Type | Liquid Chromatograph |
| Year of Manufacture / Service Duration | <1 year |
| Warranty | 12 months |
| Compliance | Imported instrument, CE-marked configuration (per standard Shimadzu factory specifications) |
| Software Platform | LabSolutions LC-40 Series (v5.9 or later, validated for GLP/GMP environments) |
| Detection | UV-Vis detector (SPD-M40), dual-wavelength simultaneous monitoring, 190–800 nm range |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Model | U3000 |
| Pump | LPG-3400SD Quaternary Low-Pressure Gradient Pump |
| Autosampler | WPS-3000SL Analytical |
| Detector | VWD-3100 Variable Wavelength UV-Vis Detector |
| Column Oven | TCC-3000RS |
| Software | Chromeleon™ 7.2 or later |
| Max Pressure | 62 MPa (620 bar) |
| Flow Rate Range | 0.001–10 mL/min |
| Injection Volume | 0.01–100 µL |
| Wavelength Range | 190–900 nm |
| Temperature Control Range | 5–110 °C |
| Warranty | 12 months |
Show next