BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelBSC-1360A2
Instrument TypeClass II A2 Biological Safety Cabinet
External Dimensions (L×W×H)1420 × 860 × 2225 mm
Internal Work Area Dimensions (L×W×H)1300 × 500 × 640 mm
HEPA Filter Efficiency≥99.99% @ 0.3 µm
Inflow Velocity0.55 m/s ±0.02 m/s
Downflow Velocity0.35 m/s ±0.02 m/s
Air Recirculation Ratio70%
Exhaust Ratio30%
Noise Level≤67 dB(A)
Vibration Peak-to-Peak≤5 µm
Average Illuminance≥650 lux
Operating Temperature Range10–30 °C
Relative Humidity Limit≤70% @ 25 °C
Atmospheric Pressure Range80–105 kPa
Personnel Protection Factor (KI Test)≥1×10⁵
Product Protection (Settle Plate)≤5 CFU/plate/test
Cross-Contamination Protection (Impactor Sampler)≤2 CFU/plate/test
Lighting & UV Lamp30 W × 1 each
Total Power Consumption1.4 kW
Electrical SupplyAC 220 V ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelBSC-1360B2
Instrument TypeClass II Biological Safety Cabinet
External Dimensions (L×W×H)1420 × 895 × 2340 mm
Internal Work Area Dimensions (L×W×H)1300 × 500 × 640 mm
HEPA Filter Efficiency≥99.99% @ 0.3 µm
Inflow Velocity0.55 m/s
Downflow Velocity0.33 m/s
Downflow Control Accuracy±0.015 m/s
Pressure Differential Range0–500 Pa
Noise Level≤67 dB(A)
Vibration Half-Peak≤5 µm
Average Illuminance≥650 lx
Operating Ambient Temperature10–30 °C
Relative Humidity≤70% @ 25 °C
Atmospheric Pressure Range80–105 kPa
Power SupplyAC 220 V ±10%, 50/60 Hz
Total Power Consumption2.2 kW
Lighting2 × 40 W fluorescent lamps + 1 × 30 W UV lamp
Supply Filter Size1326 × 606 × 70 mm
Exhaust Filter Size782 × 515 × 90 mm
Work SurfaceRemovable SUS304 stainless steel with integrated liquid collection trough and drain valve
Airflow SensorsImported U.S.-made constant-velocity anemometers
Fan SystemEBMPAPST (Germany) centrifugal blowers
Safety InterlocksUV/light interlock, sash position alarm, fan shutdown at sash closure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
ModelHY-1
TypeVortex Mixer
Speed Range2800 rpm
Orbit Diameter4 mm
Voltage100–120 VAC / 200–240 VAC (configurable)
Power60 W
Frequency50/60 Hz
Motor TypeShaded-pole motor
Operating ModesTouch-start & Continuous
Dimensions (L×W×H)170 × 120 × 140 mm
Weight~1.8 kg
ComplianceCE-marked per IEC 61010-1 for laboratory equipment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBSC-1000B2
Instrument TypeClass II Biological Safety Cabinet
External Dimensions (L×W×H)1120 × 895 × 2340 mm
Internal Work Area Dimensions (L×W×H)1000 × 500 × 640 mm
HEPA Filter Efficiency≥99.99% @ 0.3 µm
Inflow Velocity0.55 m/s
Downflow Velocity0.35 m/s
Downflow Control Accuracy±0.015 m/s
Pressure Differential Range0–500 Pa
Noise Level≤67 dB(A)
Vibration Peak-to-Peak≤5 µm
Average Illuminance≥650 lx
Operating Ambient Temperature10–30 °C
Relative Humidity≤70% (at 25 °C)
Atmospheric Pressure Range80–105 kPa
Lighting2 × 30 W fluorescent lamps + 1 × 18 W UV lamp
Power Consumption2.1 kW
Electrical SupplyAC 220 V ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBSC-1000A2
Instrument TypeClass II Biological Safety Cabinet
External Dimensions (L×W×H)1220 × 860 × 2225 mm
Internal Dimensions (L×W×H)1100 × 500 × 640 mm
Filter Efficiency (for 0.3 µm particles)≥99.99%
Inflow Velocity0.55 m/s ± 0.02 m/s
Downflow Velocity0.35 m/s ± 0.02 m/s
Airflow Pattern70% recirculated, 30% exhausted
Work Area ClassificationISO 5 (equivalent to US FED STD 209E Class 100)
Personnel Protection Factor (KI test)≥1 × 10⁵
Product Protection (colony count)≤5 CFU/test
Cross-Contamination Protection (impactor sampling)≤2 CFU/test
Noise Level≤67 dB(A)
Vibration Peak-to-Peak≤5 µm
Illumination≥650 lux
Operating Temperature10–30 °C
Relative Humidity≤70% at 25 °C
Ambient Pressure Range80–105 kPa
Power SupplyAC 220 V ±10%, 50/60 Hz
Total Power Consumption1.25 kW (including integrated AC outlets)