- All
- Favorite
- Popular
- Most rated
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZDY-501 |
| Pricing | USD 680 (FOB Shanghai) |
| Titration Mode | Fully Automatic Volumetric and Coulometric Dual-Mode |
| Instrument Type | Dual-Principle Karl Fischer Moisture Analyzer (Volumetric + Coulometric) |
| Water Content Range | 0.1 mg to 250 mg |
| Measurement Accuracy | ±3% RSD |
| Minimum Dispensing Resolution | 1/20,000 of full-scale burette volume |
| Polarization Current | 1 µA |
| Endpoint Detection Voltage Range | 40–120 mV |
| Sample Temperature Range | 5–30 °C |
| Dimensions (W×D×H) | 280 × 210 × 120 mm |
| Net Weight | 5 kg |
| Brand | Leichi |
|---|---|
| Model | SFS-101S |
| Heating Source | Circular Halogen Lamp |
| Temperature Range | Ambient to 180 °C |
| Weighing Range | 0.2–110 g |
| Readability | 5 mg (d), 10 mg (e) |
| Moisture Resolution | 0.02% |
| Sample Minimum Mass | 1 g |
| Pan Diameter | 90 mm |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 310 × 180 × 157 mm |
| Net Weight | 2.6 kg |
| Interface | RS-232 for printer output |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDY-504 |
| Titration Method | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Moisture Range | Volumetric: 0.1–250.0 mg H₂O |
| Coulometric | 10 μg–20 mg H₂O |
| Resolution | 0.1 mg |
| Accuracy | Volumetric: ≤0.5% RSD |
| Coulometric | RSD ≤3% at 100 μg H₂O |
| Minimum Dispensing Volume | 0.005 mL |
| Titration Control Precision | 1/12000 |
| Polarization Current | 1 μA ± 0.2 μA |
| Electrolysis Current Options (Coulometric) | 10, 20, 50, 100 mA |
| Water Equivalence Factors (Coulometric) | 1, 1.86, 5, 10 μg H₂O/s |
| Measurement Error (Coulometric) | ±(5% of reading + 3) μg |
| Dimensions (L×W×H) | 340 × 400 × 400 mm |
| Weight | ~10 kg |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SFS-105J |
| Price | USD 658 (FOB Shanghai) |
| Weighing Range | 0.2 g to 110 g |
| Readability (d) | 5 mg |
| Verification Scale Interval (e) | 10 mg |
| Moisture Readability | 0.02 % |
| Accuracy Class | OIML Class II |
| Minimum Sample Mass | 1 g |
| Heating Source | Circular Halogen Lamp |
| Temperature Control Range | Ambient to 200 °C |
| Sample Pan Diameter | 90 mm |
| Real-time Display | Temperature, Elapsed Heating Time, Dynamic Moisture %, Dry Weight %, ATRO Dry Basis %, ATRO Wet Basis % |
| Drying Modes | Standard, Rapid, and Gradual |
| Endpoint Detection | Auto, Manual, and Semi-Automatic |
| Communication Interface | RS-232 for Thermal Printer Output |
| Power Supply | 220 V ± 10 %, 50/60 Hz |
| Dimensions (W×D×H) | 330 × 200 × 200 mm |
| Net Weight | 5.8 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KLS-411 |
| Pricing | USD 1,650 (FOB Shanghai) |
| Titration Mode | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 10 µg to 20 mg |
| Measurement Accuracy | ≤ ±3% RSD |
| Electrolysis Current Settings | 10 mA / 20 mA / 50 mA / 100 mA |
| Polarization Current Error | ±0.2 µA |
| Electrolysis Current Basic Error | ±0.5% of reading |
| Indication Error | ±(5% of calibration point + 3) µg |
| Repeatability | ≤3% RSD |
| Power Supply | (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 300 × 235 × 100 mm |
| Weight | 3 kg |
| Interface | RS-232 for printer and data export |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | ZDY-502 |
| Titration Method | Fully Automatic |
| Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 0.1 mg to 250 mg (equivalent to 0.1 mg – 100% w/w water content) |
| Resolution | 0.1 mg |
| Accuracy | < ±0.75% RSD |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 1/12,000 |
| Polarization Current Accuracy | 1 μA ± 0.2 μA |
| Repeatability | ±0.5% |
| Power Supply | (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SFS-105S |
| Price | USD 445 (FOB Shanghai) |
| Weighing Range | 0.2 g to 110 g |
| Readability (d) | 5 mg |
| Verification Scale Interval (e) | 10 mg |
| Moisture Readability | 0.02 % |
| Accuracy Class | II (per OIML R76) |
| Minimum Sample Mass | 1 g |
| Heating Source | Circular Halogen Lamp |
| Temperature Control Range | Ambient to 180 °C |
| Heating Chamber Material | Heat-Resistant Polymer Housing |
| Sample Pan Diameter | 90 mm |
| Display | High-Resolution LCD with Real-Time Parameters |
| Drying Modes | Standard, Rapid, and Custom Timed |
| End Point Detection | Auto, Manual, and Semi-Automatic |
| Moisture Result Units | % Moisture, % Dry Weight, ATRO Dry Basis, ATRO Wet Basis |
| Interface | RS-232 Serial Port for Thermal Printer Output |
| Power Supply | 220 V ±10 %, 50/60 Hz |
| Dimensions (W×D×H) | 310 × 180 × 157 mm |
| Net Weight | 2.6 kg |
| Operating Environment | 10–30 °C, ≤80 % RH non-condensing |
Show next