- All
- Favorite
- Popular
- Most rated
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010A (Red-Black Label) |
| Category | Imported Used Analytical Instrument |
| Distribution Type | Authorized Distributor |
| Price Range | USD 6,800 – 19,000 (FOB Asia) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7820A |
| Dimensions (H×W×D) | 49 × 56 × 51 cm |
| Weight | 50 kg |
| Column Oven Temp Range | 8 °C above ambient to 425 °C |
| Max Ramp Rate | 75 °C/min |
| Temperature Stability | < 0.01 °C per 1 °C ambient change |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| EPC Pressure Control Accuracy | ±0.01 psi |
| FID MDL | < 3 pg C/s (tridecane) |
| TCD MDL | < 800 pg propane/mL (He carrier) |
| NPD MDL | < 0.4 pg N/s, < 0.2 pg P/s (azobenzene/mixture) |
| ECD MDL | < 0.02 pg/mL (lindane) |
| Operating Environment | 15–30 °C, 30–70% RH |
| Safety Compliance | UL 61010, CSA C22.2 No. 61010, IEC 61010, EN 61010 |
| EMC Compliance | CISPR 11 / EN 55011 Class A, IEC/EN 61326 |
| Quality System | ISO 9001 certified |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010Plus |
| Configuration | Multi-detector, Dual Autosampler (AOC-20i ×2 + AOC-20s) |
| Column Oven Temp Range | Ambient +4°C to 450°C (down to –50°C with liquid CO₂ cooling option) |
| Cooling Rate | 450°C → 50°C in ≈3.4 min |
| Detector Options | FID (1.5 pgC/s), ECD (6 fg/s), FPD (P: 55 fgP/s |
| S | 3 pgS/s), TCD, FTD/NPD |
| AFC Pressure Control | 0–970 kPa, 7-segment programming |
| Max Simultaneous Detectors | 4 |
| Max Simultaneous Inlet Units | 3 |
| Display | 240 × 320 dot graphic LCD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Configuration | Dual Inlet / Triple Detector (incl. TCD) |
| EPC Channels | Up to 16 |
| Temperature Range | –80 °C to 450 °C (with LN₂ cooling) |
| Retention Time Reproducibility | < 0.008% RSD |
| Peak Area Reproducibility | < 1% RSD |
| Column Oven Dimensions | 28 × 31 × 16 cm |
| Max Ramp Rate | 120 °C/min |
| Cooling from 450 °C to 50 °C | 4.0 min (standard), 3.5 min (with insert) |
| Pressure Control Precision | ±0.001 psi (0–99.999 psi range) |
| Data Acquisition Rate | Up to 500 Hz (FID) |
| Supported Detectors | FID, TCD, Micro-ECD, NPD, FPD, SCD, NCD, MSD (via interface) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2014A |
| Column Oven Temp Range | Ambient +10 °C to 420 °C (–50 °C to 420 °C with liquid CO₂ cooling) |
| Injector Temp Range | Up to 420 °C |
| Detector Temp Range | Up to 420 °C (FID/TCD/FTD), up to 400 °C (ECD/FPD) |
| Max Simultaneous Inlets | 3 |
| Max Simultaneous Detectors | 4 |
| Programmed Temperature Ramping | 20-step, –250 to +250 °C/min |
| Pressure Control | Digital AFC (0–970 kPa, ramp rate –400 to +400 kPa/min) |
| Display | 240 × 320-pixel graphical LCD |
| Dimensions (W×H×D) | 607 × 690 × 400 mm |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Column Oven Temperature Range | 0–450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Detector Compatibility | FID, TCD, ECD, NPD, FPD, MSD (with appropriate interface) |
| Software Platform | OpenLab CDS (ChemStation-compatible mode available) |
| Compliance | ASTM D3606, D5186, ISO 10301, USP <621>, FDA 21 CFR Part 11 (when configured with audit trail & electronic signature) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Detector Options | FID (detection limit <5 pg C/s on propane), TCD, ECD, NPD, FPD, FTD |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Integrated Control | Agilent 7683 Autoinjector |
| Compliance | ASTM D3606, D5503, ISO 10301, USP <621>, FDA 21 CFR Part 11 ready (with ChemStation Plus configuration) |
Show next