Empowering Scientific Discovery

Hangzhou Kexiao Chemical Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Instrument TypeBenchtop Laboratory Conductivity Meter
Measurement ParameterSingle-parameter (Conductivity)
Conductivity Range0.00 µS/cm to 200 mS/cm
Accuracy±1.0% FS
Minimum Resolution0.01 µS/cm (auto-ranging)
Temperature CompensationManual
Calibration1-point calibration with auto-recognition of 4 GB-standard conductivity solutions
Electrode Constant SupportAutomatic frequency switching compatible with K = 1.0 cell
Data Storage50 measurement sets
DisplayHigh-resolution LCD with key-based navigation
Enclosure RatingIP54
Power SupplyAC/DC adapter (Input: 100–240 V AC
Output20 V DC / 1500 mA)
Dimensions (W×D×H)242 × 195 × 68 mm
Weight0.9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDBJ-351L
PortabilityPortable
ApplicationLaboratory
Conductivity Range0.000 µS/cm to 3000 mS/cm
TDS Range0.000 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range(0.00–8.00)%
Temperature Range(−10.0–135.0) °C / (14.0–275.0) °F
Accuracy±0.5% FS (conductivity, resistivity, TDS), ±0.1% FS (salinity), ±0.1 °C (temperature)
Minimum Resolution0.001 µS/cm (conductivity), 0.01 Ω·cm (resistivity), 0.001 mg/L (TDS), 0.01% (salinity), 0.1 °C/°F (temperature)
IP RatingIP65
ComplianceGLP-compliant data management, supports ASTM D1125, ISO 7888, USP <645>, and IEC 61000-4 EMC standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDZS-708L (EC-T Conductivity & Temperature Module Kit)
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range0.000 μS/cm to 3000 mS/cm
TDS Range0.00 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range0.00–8.00 %
Temperature Range−10.0–135.0 °C (14.0–275.0 °F)
Accuracy±0.5 % FS (Conductivity/Resistivity/TDS), ±0.1 % FS (Salinity), ±0.3 °C (0.0–60.0 °C), ±1.0 °C (other ranges)
Minimum Resolution0.001 μS/cm (conductivity), auto-ranging
IP RatingIP54
ComplianceGLP-compliant data management, supports 21 CFR Part 11 audit trail via optional software configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDSJ-307F
Instrument Class1.0
Measurement ParametersConductivity, Resistivity, TDS, Salinity, Temperature
Conductivity Range0.000 µS/cm to 1000 mS/cm
TDS Range0.00 mg/L to 300 g/L
Resistivity Range5.00 Ω·cm to 20.00 MΩ·cm
Salinity Range(0.00–8.00)%
Temperature Range(−5.0–110.0) °C / (23.0–230.0) °F
Minimum Conductivity Resolution0.001 µS/cm (auto-ranging)
Temperature Resolution0.1 °C / 0.1 °F
Conductivity Accuracy±1.0% FS
Temperature Accuracy±0.2 °C
Input PowerAC 100–240 V → DC 9 V
Dimensions242 × 195 × 68 mm
Weight0.9 kg
Protection RatingIP54
Data Storage500 datasets per parameter
InterfaceRS-232, USB
ComplianceGLP-compliant data logging with audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDDB-303A
PriceUSD 205 (FOB Shanghai)
Measurement ParametersConductivity only
PortabilityHandheld
Intended UseField and Lab
Conductivity Range0.000 µS/cm to 100 mS/cm
Accuracy±1.0% FS
Minimum Resolution0.01 µS/cm (auto-ranging)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDB-301
PortabilityPortable
Application EnvironmentLaboratory & Field
Measurement ParameterElectrical Conductivity (Single-Parameter)
Resolution1 pS/m
Measurement Range0–1999 pS/m
DisplayLCD
Power SupplyTwo 476A 6V Alkaline Batteries
Operating Temperature0–40 °C
Relative Humidity≤85% RH
Dimensions85 × 220 × 50 mm
Weight~350 g
Explosion ProtectionEx ia IIA T5 Ga (Certificate No.: GYB23.2384X)
Standard ElectrodeDJSY-0.01 Fuel Conductivity Cell
AccessoriesSilicone Protective Sleeve, Metal Measuring Beaker
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDS-307A
Form FactorBenchtop
Application EnvironmentLaboratory
Conductivity Range0.00 µS/cm to 200 mS/cm
TDS Range0.00 mg/L to 100 g/L
Temperature Range−5.0 °C to 110.0 °C
Accuracy±1.0% FS
Minimum Conductivity Resolution0.01 µS/cm (auto-ranging)
TDS Resolution0.01 mg/L (auto-ranging)
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Conductivity ClassClass 1.0 per GB/T 11018
IP RatingIP54
Data Storage50 measurement sets
CalibrationSingle-point conductivity calibration with auto-recognition of 4 standard GB solutions
Temperature CompensationAutomatic and manual modes
Electrode Constant SupportAuto-frequency switching for K = 1.0 cell
Power SupplyAC/DC adapter (Input: 100–240 VAC, Output: 20 VDC / 1500 mA)
Dimensions (W×D×H)242 × 195 × 68 mm
Weight0.9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDBJ-350
PortabilityPortable
ApplicationLaboratory Use
Conductivity Range0.000 µS/cm to 500 mS/cm
TDS Range0.000 mg/L to 300 g/L
Resistivity Range5.00 Ω·cm to 20.00 MΩ·cm
Salinity Range(0.00–8.00)%
Temperature Range(−5.0–110.0) °C / (23.0–230.0) °F
Accuracy±1.0% FS (conductivity, resistivity, TDS), ±0.2% FS (salinity), ±0.2 °C (temperature)
Minimum Resolution0.001 µS/cm (conductivity), 0.01 Ω·cm (resistivity), 0.01 mg/L (TDS), 0.01% (salinity), 0.1 °C/°F (temperature)
IP RatingIP65
Electrode CompatibilityAuto-recognized 4 GB standard solutions
Compensation ModesNon-compensated, linear (with reference at 20 °C or 25 °C), and pure-water compensation
Data Storage500 datasets per parameter
InterfaceUSB, RS-232
PowerRechargeable Li-ion battery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Instrument TypeBenchtop Laboratory Conductivity Meter
Measurement ParameterConductivity Only
Measurement Range0.00 μS/cm to 100.0 mS/cm
Accuracy±1.5% of Full Scale (FS)
Minimum Resolution0.01 μS/cm (auto-ranging)
Temperature CompensationManual
Electrode Constant InputAdjustable (default 1.0 cm⁻¹)
Auto Frequency SwitchingYes
DisplayLCD with Stability Indicator
Enclosure RatingIP54
Power SupplyDC 20 V / 1500 mA (AC 100–240 V input adapter)
Dimensions200 × 160 × 63 mm
Weight0.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDBJ-350F
PortabilityPortable
ApplicationLaboratory
Conductivity Range0.000 µS/cm to 1000 mS/cm
TDS Range0.000 mg/L to 300 g/L
Resistivity Range5.00 Ω·cm to 20.00 MΩ·cm
Salinity Range(0.00–8.00)%
Temperature Range(−5.0–110.0) °C / (23.0–230.0) °F
Accuracy±1.0% FS (conductivity, resistivity, TDS), ±0.2% FS (salinity), ±0.2 °C (temperature)
Minimum Resolution0.001 µS/cm (conductivity), 0.01 Ω·cm (resistivity), 0.001 mg/L (TDS), 0.01% (salinity), 0.1 °C/°F (temperature)
IP RatingIP65
Electrode CompatibilityAuto-recognized 4 GB standard solutions
Compensation ModesNon-compensated, linear (with selectable reference temp: 20 °C or 25 °C), and pure water compensation
Data Storage1000 datasets per parameter
InterfaceUSB Type-B, RS-232
PowerRechargeable Li-ion battery (DC5V input via AC adapter, 100–240 VAC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
OriginShanghai, China
ModelDDSJ-319L
Detection ParametersSingle-parameter (Conductivity, Resistivity, TDS, Salinity, Temperature)
Form FactorBenchtop
Intended UseLaboratory
Conductivity Range0.000 µS/cm to 3000 mS/cm
TDS Range0.000 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range(0.00–8.00)%
Temperature Range(−5.0–130.0) °C
Accuracy±0.5% FS (Conductivity/Resistivity/TDS), ±0.1% FS (Salinity), ±0.1 °C (Temperature)
Minimum Resolution0.001 µS/cm (Conductivity), 0.01 Ω·cm (Resistivity), 0.001 mg/L (TDS), 0.01% (Salinity), 0.1 °C (Temperature)
ComplianceGLP-compliant data management, supports ASTM D1125, ISO 7888, USP <645>, and GB/T 6682 for water quality testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDDB-305A
PortabilityPortable
Intended UseLaboratory
Conductivity Range0.00 μS/cm to 200 mS/cm
TDS Range0.00 mg/L to 100 g/L
Temperature Range(−5.0 to 110.0) °C / (23.0 to 230.0) °F
Accuracy±1.0% FS
Minimum Resolution0.01 μS/cm (auto-ranging)
TDS Resolution0.01 mg/L (auto-ranging)
Temp. Resolution0.1 °C / 0.1 °F
Temp. Accuracy±0.2 °C
IP RatingIP65
Data Storage200 sets
PowerRechargeable Li-ion battery, DC5V adapter input (AC100–240V)
Dimensions80 × 225 × 35 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Leici
OriginShanghai, China
ModelDDSJ-318T
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range0.000 µS/cm to 2000 mS/cm
TDS Range0.000 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.0 MΩ·cm
Salinity Range0.00–8.00 %
Temperature Range−10.0 to 135.0 °C
Accuracy±0.5% FS (Conductivity/TDS/Resistivity), ±0.1% FS (Salinity), ±0.1 °C (Temperature)
Minimum Resolution0.001 µS/cm (Conductivity), 0.01 Ω·cm (Resistivity), 0.001 mg/L (TDS), 0.01% (Salinity), 0.1 °C (Temperature)
ComplianceGLP, GMP-ready, ASTM D1125, ISO 7888, USP <645>, EN 27888
ConnectivityRS-232, USB, Optional Auto-sampler Interface
Data Storage1000 measurement records with audit trail
IP RatingIP54
Electrode SupportAutomatic recognition of 0.01, 0.1, and 1.0 cm⁻¹ conductivity cells
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Leici
OriginShanghai, China
ModelDDSJ-308F
Form FactorBenchtop
ApplicationLaboratory
Conductivity Range0.000 µS/cm to 1000 mS/cm
TDS Range0.000 mg/L to 1000 g/L
Resistivity Range5.00 Ω·cm to 100.00 MΩ·cm
Salinity Range0.00–8.00 %
Temperature Range−10.0 to 135.0 °C
Accuracy±0.5% FS (conductivity/resistivity/TDS), ±0.1% FS (salinity), ±0.1 °C (temperature)
Resolution0.001 µS/cm (conductivity), 0.01 Ω·cm (resistivity), 0.001 mg/L (TDS), 0.01% (salinity), 0.1 °C/°F (temperature)
Compensation ModesNon-compensated, Linear, Pure Water
Auto-CalibrationSupports 1–3 point calibration with automatic recognition of four GB-standard conductivity solutions
InterfaceRS-232, USB
Data Storage500 sets per parameter
ComplianceGLP-compliant data logging with audit trail support
Enclosure RatingIP54
PowerDC 9 V (AC 100–240 V input adapter)
Dimensions242 × 195 × 68 mm
Weight0.9 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0