Empowering Scientific Discovery

Hangzhou Kexiao Chemical Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
OriginShanghai, China
ModelSJG-791
Instrument TypeOnline Analyzer
Measurement PrincipleElectrochemical Amperometric Sensor
Measured ParameterFree Residual Chlorine
Range0.00–20.00 mg/L
Accuracy±10% (≥0.5 mg/L) or ±0.05 mg/L (<0.5 mg/L)
Resolution0.01 mg/L (Cl₂), 0.01 pH, 0.1 °C
pH Range0.00–14.00 pH
Temperature Range0.0–60.0 °C
pH Accuracy±0.05 pH
Temp Accuracy±0.5 °C
Linear Error±3.0% FS (Cl₂)
Electronic Unit Stability±1% FS/24 h
90% Response Time2 min
Enclosure RatingIP65
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions166 × 166 × 110 mm
Weight2 kg
OutputDual isolated 4–20 mA DC (configurable for Cl₂ or pH), RS-232/RS-485 (Modbus RTU)
Data Storage2000 records
Auto CompensationpH and temperature compensated for residual chlorine measurement
AlarmConfigurable upper/lower limits with hysteresis
Power Failure ProtectionYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelSJG-792
Instrument TypeOnline Analyzer
Measurement PrincipleElectrochemical Amperometric Sensor Method
Measured ParametersResidual Chlorine, Total Chlorine
Range(0.00–5.00) mg/L
Accuracy±5% (for values >1 mg/L) or ±0.05 mg/L (for values ≤1 mg/L)
Repeatability±0.025 mg/L (≤1 mg/L)
Resolution0.01 mg/L
Limit of Detection (LOD)≤0.05 mg/L
DisplayDot-matrix LCD
Data StorageUp to 700 records with SD card export
OutputIsolated 4–20 mA DC (configurable span), RS-232 or RS-485 (Modbus RTU)
Ingress ProtectionIP65
Power SupplyAC (220 ± 22) V, (50 ± 0.5) Hz
Calibration OptionsFactory pre-loaded calibration curves, manual zero + up to two-point span calibration, in-process calibration support
Alarm FunctionsProgrammable high/low concentration thresholds
DiagnosticsBuilt-in self-diagnostic system
Power Failure ProtectionNon-volatile memory retention
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandLeiCi
OriginShanghai, China
ModelDGB-402F
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measurable ParametersResidual Chlorine, Total Chlorine
Range0–5 mg/L
Accuracy±0.05 mg/L (≤1 mg/L)
Repeatability≤2.0%
ResolutionConcentration: 0.001 mg/L
Absorbance0.001 ABS
LOD≤0.02 mg/L
Wavelength515 nm LED
Calibration1–3 point user-defined or factory-default curves
Data Storage200 entries per parameter
Protection RatingIP65
Operating Temperature5–35 °C
Relative Humidity≤85% RH
PowerRechargeable Li-ion battery
Dimensions85 × 230 × 50 mm
Weight~0.5 kg]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelSJG-791B
Instrument TypeOnline Analyzer
Measurement PrincipleElectrochemical Amperometric Sensor Method
Measurable ParametersResidual Chlorine / Total Chlorine / Chlorine Dioxide / Ozone (user-selectable single parameter)
Measurement Range0.005–2.000 mg/L (standard range)
Accuracy±1% FS (for residual chlorine with DCS4H-M0c electrode)
Resolution0.001 mg/L
Temperature CompensationAutomatic (5–40 °C sample range)
OutputIsolated 4–20 mA (600 Ω max load), RS-485 Modbus RTU
Enclosure RatingIP65
Power SupplyAC 220 V ±10%, 50 Hz
InstallationWall-mounted analyzer + flow-through sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDGB-402A
Instrument TypePortable Colorimeter
Measurement PrincipleDPD Spectrophotometric Method
Measured ParametersResidual Chlorine, Total Chlorine
Range(0.02–3.00) mg/L
Accuracy±3% or ±0.02 mg/L
Repeatability≤1%
Resolution0.01 mg/L
Detection Limit≤0.02 mg/L
Light Source515 nm LED
Wavelength AccuracyFixed at 515 nm
Cuvette Size25 mm diameter
Data Storage200 measurement records
Power SupplyRechargeable Li-ion battery
AC/DC adapter (InputAC 100–240 V, Output: DC 5 V)
Protection RatingIP65
Dimensions (L×W×H)80 × 200 × 75 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDGB-403F
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measurable ParametersResidual Chlorine (LR/HR), Total Chlorine (LR/HR), Chlorine Dioxide (LR/HR), Monochloramine (LR/HR), Chlorite, Chlorate, Hydrogen Peroxide
Residual Chlorine HR Range0.20–12.0 mg/L
Accuracy (Residual Cl₂ HR)±0.1 mg/L or ±5%
Repeatability (Residual Cl₂ HR)≤1%
Resolution (Residual Cl₂ HR)0.1 mg/L
LOD (Residual Cl₂ HR)≤0.2 mg/L