| Origin | Shanghai, China |
| Model | BXM-75M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 700 mm |
| External Dimensions | 750 × 800 × 1080 mm |
| Chamber Volume | 75 L |
| Sterilization Temp Range | 105–135°C |
| Drying Temp Range | 102°C |
| Melting Temp Range | 40–100°C |
| Holding Temp Range | 25–85°C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air rapid cooling |
| Air Intake Filtration | Built-in HEPA-grade filter |
| Dual Water Inlet System | Selectable pure water or tap water |
| Condensate Recycling System (C.W.S.) | Integrated |
| Waste Gas & Effluent Purification System (W.P.S.) | Integrated |
| Standard Sample Temperature Probe | Yes |
| Data Logging & Export | Yes |
| Safety Features | Mechanical self-locking + electronic interlock door, overtemperature cutoff, independent safety limiter, overpressure relief valve, fault self-diagnosis |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-60EI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 535 × 640 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Heating Power | 3.2 kW |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-85VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 535 × 640 × 1165 mm |
| Chamber Volume | 85 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-100A |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135°C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 830 mm |
| Chamber Volume | 100 L |
| External Dimensions | 485 × 605 × 1290 mm |
| Power Rating | 3.5 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating Temperature Range | 105–135°C |
| Design Temperature | 138°C |
| Design Pressure | 0.25 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Ø360 × 240 mm (3 pcs) |
| Safety Features | Automatic water-level monitoring, overtemperature cutoff, pressure relief valve, self-sealing gasket, cold-air purge cycle, programmable exhaust modes (fast/slow/no exhaust), audible end-of-cycle alert |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-50M |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 520 mm |
| External Dimensions | 750 × 800 × 950 mm |
| Chamber Volume | 50 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.1 kW |
| Supply Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Temp | 5–40 °C |
| Ambient Humidity | 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-50A |
| Instrument Type | Vertical Autoclave |
| Max Operating Temperature | 135 °C |
| Max Operating Pressure | 0.22 MPa |
| Chamber Dimensions | Ø300 × 755 mm |
| Chamber Volume | 50 L |
| External Dimensions | 445 × 525 × 1120 mm |
| Power Supply | 220 V ±10%, 50 Hz ±2% |
| Rated Power | 2.7 kW |
| Timer Range | 0–120 min |
| Safety Design Pressure | 0.25 MPa |
| Safety Design Temperature | 138 °C |
| Basket Dimensions | Ø280 × 210 mm (3 pcs) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-50SII |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Φ400 × 630 mm |
| Chamber Volume | 50 L |
| External Dimensions | 485 × 485 × 1120 mm |
| Power | 3.1 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Timer Range | 0–120 min |
| Design Temp/Pressure | 138 °C / 0.25 MPa |
| Basket Size | Φ360 × 240 mm (2 pcs) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-100G |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 mm × 850 mm |
| Chamber Volume | 100 L |
| External Dimensions | 485 mm × 605 mm × 1290 mm |
| Sterilization Power | 4.5 kW |
| Drying Power | 1.0 kW |
| Voltage | 220 V ±10%, 50 Hz ±2% |
| Sterilization Timer | 4–120 min |
| Drying Timer | 30–240 min |
| Safety Design Pressure | 0.25 MPa |
| Safety Design Temperature | 138 °C |
| Basket Dimensions | Ø360 mm × 240 mm × 3 units |
| Cold Air Purge | Automatic |
| Sealing | Self-expanding silicone gasket |
| Door Mechanism | Handwheel-operated with safety interlock |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXW-SD |
| Instrument Type | Horizontal |
| Max Temperature | 131 °C |
| Max Pressure | 0.2 MPa |
| Chamber Dimensions | Ø472 mm × 1025 mm |
| External Dimensions | 764 mm × 1460 mm × 1590 mm |
| Chamber Volume | 150 L |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-70A |
| Instrument Type | Vertical Autoclave |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 mm × 720 mm |
| Chamber Volume | 75 L |
| External Dimensions | 485 mm × 605 mm × 1170 mm |
| Power Supply | 220 V ±10%, 50 Hz ±2% |
| Rated Power | 3.5 kW |
| Timer Range | 0–120 min |
| Safety Design Pressure | 0.25 MPa |
| Safety Design Temperature | 138 °C |
| Basket Dimensions | Ø360 mm × 280 mm × 2 units |
| Control Modes | Fast Exhaust / Slow Exhaust / No Exhaust |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-75G |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 mm × 720 mm |
| Chamber Volume | 75 L |
| External Dimensions | 485 mm × 605 mm × 1190 mm |
| Sterilization Power | 3.5 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Design Temp/Pressure | 138 °C / 0.25 MPa |
| Sterilization Timer | 4–120 min |
| Drying Timer | 30–240 min |
| Basket Size | Ø360 mm × 280 mm × 2 units |
| Safety Features | Automatic cold-air purge, self-sealing gasket, overpressure relief, low-water alarm, dry-run protection, dual-limit temperature cutoff, interlocked handwheel door |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-75SII |
| Instrument Type | Vertical |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Diameter × Height | Φ400 mm × 720 mm |
| Chamber Volume | 75 L |
| External Dimensions (W×D×H) | 485 mm × 485 mm × 1190 mm |
| Power Supply | 220 V ±10%, 50 Hz ±2% |
| Rated Power | 3.5 kW |
| Sterilization Timer Range | 0–120 min |
| Design Temperature/Pressure | 138 °C / 0.25 MPa |
| Safety Features | Automatic cold-air purge, self-sealing gasket, low-water level alarm, overpressure relief valve, overtemperature protection, door interlock system |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YXQ-LS-18SI |
| Instrument Type | Portable |
| Max Temperature | 126 °C |
| Max Pressure | 0.142 MPa |
| Chamber Dimensions | Φ280 × 290 mm |
| External Dimensions | Φ390 × 530 mm |
| Chamber Volume | 18 L |
| Power | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temp. | 126 °C / 128 °C |
| Operating/Design Pressure | 0.142 MPa / 0.165 MPa |
| Timer Range | 0–60 min |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-60VF |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 150 °C |
| Maximum Working Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 585 × 750 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temperature Range | 80–130 °C |
| Melting/Soaking Range | 50–100 °C |
| Holding Range | 40–60 °C |
| Power Input | 4.8 kW |
| Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXW-JDM |
| Type | Horizontal |
| Max Temperature | 138 °C |
| Max Working Pressure | 0.242 MPa |
| Chamber Dimensions | 671 × 600 × 600 mm |
| External Dimensions | 927 × 1236 × 1780 mm |
| Chamber Volume | 240 L |
| Design Pressure (Chamber) | −0.1 to 0.26 MPa |
| Jacket Design Pressure | 0.26 MPa |
| Pulse Range | 0–99 cycles |
| Pulse Amplitude (Positive) | 0.065–0.09 MPa |
| Pulse Amplitude (Negative) | −0.05 to −0.09 MPa |
| Air Removal Efficiency | >99% (≥3 pulses) |
| Vacuum Leakage Rate | <0.13 kPa/min |
| Drying Time Range | 0–9999 s |
| Safety Valve Set Pressure | 0.25 MPa |
| Reseat Pressure | 0.22 MPa |
| Steam Supply | Integrated electric steam generator or external source (0.3–0.5 MPa) |
| Compressed Air Supply | 0.5–0.7 MPa |
| Water Supply Pressure | 0.15–0.30 MPa |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-LS-75G |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 720 mm |
| Chamber Volume | 75 L |
| External Dimensions | 485 × 605 × 1190 mm |
| Sterilization Power | 3.5 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Sterilization Timer | 4–120 min |
| Drying Timer | 30–240 min |
| Safety Design Pressure/Temperature | 0.25 MPa / 138 °C |
| Basket Size | Ø360 × 280 mm × 2 pcs |
| Material | SUS304 stainless steel chamber, door, and baskets |
| Brand | Brookfield (BOXUN) |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VF |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-100M |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-50G |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 640 mm |
| Chamber Volume | 50 L |
| External Dimensions | 485 × 605 × 1120 mm |
| Sterilization Power | 3.2 kW |
| Drying Power | 0.8 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Design Temp/Pressure | 138 °C / 0.25 MPa |
| Sterilization Timer Range | 4–120 min |
| Drying Timer Range | 30–240 min |
| Basket Dimensions | Ø360 × 240 mm (2 pcs) |
| Safety Features | Auto cold-air purge, overpressure relief, low-water alarm, dry-run protection, overtemperature cutoff, self-sealing gasket, interlocked manual door |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Interface | Capacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXW-SD-A/G |
| Instrument Type | Horizontal |
| Max Temperature | 131 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Ø600 × 1050 mm |
| External Dimensions | 911 × 1432 × 1803 mm |
| Chamber Volume | 280 L |
| Power Supply | 380 V / 50 Hz |
| Heating Power (A-type) | 13 kW |
| Heating Power (G-type) | 14.5 kW |
| Compliance | Designed for GLP-compliant sterilization workflows, compatible with ISO 17665-1, EN 285, and GB 8599 standards |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-30SII |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.22 MPa |
| Chamber Dimensions | Φ300 × 485 mm |
| Chamber Volume | 30 L |
| External Dimensions | 445 × 445 × 900 mm |
| Power | 2.3 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating Temperature Range | 105–135 °C |
| Operating Pressure Range | 0.07–0.22 MPa |
| Timer Range | 0–120 min |
| Safety Design Pressure | 0.25 MPa |
| Safety Design Temperature | 138 °C |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Material | SUS304 stainless steel chamber, door, and basket |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-30R |
| Instrument Type | Vertical |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temp. | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-150M |
| Instrument Type | Vertical Steam Sterilizer |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp Range | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 0–999 min |
| Melting/Holding Time Range | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
Show next