BrandBoxun
OriginShanghai, China
ModelBXM-75M
Instrument TypeVertical
Max Temperature135°C
Max Working Pressure0.22 MPa
Chamber DimensionsØ400 × 700 mm
External Dimensions750 × 800 × 1080 mm
Chamber Volume75 L
Sterilization Temp Range105–135°C
Drying Temp Range102°C
Melting Temp Range40–100°C
Holding Temp Range25–85°C
Sterilization Time4–120 min
Drying Time0–999 min
Melting/Holding Time0–999 min
Delay StartUp to 99 h 60 min
Design Pressure0.25 MPa
Drying Residual Moisture<1%
Heating Power5.9 kW
Power Supply~220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Conditions5–40°C, 20–80% RH
Chamber & Basket MaterialSUS304 stainless steel
Cooling MethodForced-air rapid cooling
Air Intake FiltrationBuilt-in HEPA-grade filter
Dual Water Inlet SystemSelectable pure water or tap water
Condensate Recycling System (C.W.S.)Integrated
Waste Gas & Effluent Purification System (W.P.S.)Integrated
Standard Sample Temperature ProbeYes
Data Logging & ExportYes
Safety FeaturesMechanical self-locking + electronic interlock door, overtemperature cutoff, independent safety limiter, overpressure relief valve, fault self-diagnosis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield (BOXUN)
OriginShanghai, China
ModelBXM-60EI
Instrument TypeVertical
Max Temperature150 °C
Max Pressure0.38 MPa
Chamber DimensionsØ400 × 635 mm
External Dimensions535 × 640 × 1075 mm
Chamber Volume60 L
Temperature Uniformity±0.5 °C
Temperature Fluctuation< +1 °C
Sterilization Time Range0–120 min (customizable up to 6000 min)
Power Supply~220 V ±22 V, 50 Hz ±1 Hz
Heating Power3.2 kW
Ambient Operating Conditions5–40 °C, 20–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoxun
OriginShanghai, China
ModelBXM-85VE
Instrument TypeVertical Autoclave
Max Temperature150 °C
Max Pressure0.38 MPa
Chamber DimensionsØ400 × 725 mm
External Dimensions535 × 640 × 1165 mm
Chamber Volume85 L
Temperature Uniformity±0.5 °C
Temperature Fluctuation< +1 °C
Sterilization Time Range0–120 min (customizable up to 6000 min)
Power Supply~220 V ±22 V, 50 Hz ±1 Hz
Ambient Operating Conditions5–40 °C, 20–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-100A
Instrument TypeVertical Autoclave
Max Temperature135°C
Max Pressure0.22 MPa
Chamber DimensionsØ400 × 830 mm
Chamber Volume100 L
External Dimensions485 × 605 × 1290 mm
Power Rating3.5 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Operating Temperature Range105–135°C
Design Temperature138°C
Design Pressure0.25 MPa
Timer Range0–120 min
Basket DimensionsØ360 × 240 mm (3 pcs)
Safety FeaturesAutomatic water-level monitoring, overtemperature cutoff, pressure relief valve, self-sealing gasket, cold-air purge cycle, programmable exhaust modes (fast/slow/no exhaust), audible end-of-cycle alert
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoxun
OriginShanghai, China
ModelBXM-50M
Instrument TypeVertical
Max Temperature150 °C
Max Working Pressure0.22 MPa
Chamber DimensionsØ400 × 520 mm
External Dimensions750 × 800 × 950 mm
Chamber Volume50 L
Sterilization Temp Range105–135 °C
Drying Temp102 °C
Melting Temp Range40–100 °C
Holding Temp Range25–85 °C
Sterilization Time4–120 min
Drying Time0–999 min
Melting/Holding Time0–999 min
Delay Startup to 99 h 60 min
Design Pressure0.25 MPa
Drying Residual Moisture<1%
Heating Power5.1 kW
Supply Voltage220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Temp5–40 °C
Ambient Humidity20–80% RH
Chamber & Basket MaterialSUS304 Stainless Steel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-50A
Instrument TypeVertical Autoclave
Max Operating Temperature135 °C
Max Operating Pressure0.22 MPa
Chamber DimensionsØ300 × 755 mm
Chamber Volume50 L
External Dimensions445 × 525 × 1120 mm
Power Supply220 V ±10%, 50 Hz ±2%
Rated Power2.7 kW
Timer Range0–120 min
Safety Design Pressure0.25 MPa
Safety Design Temperature138 °C
Basket DimensionsØ280 × 210 mm (3 pcs)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-50SII
Instrument TypeVertical
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsΦ400 × 630 mm
Chamber Volume50 L
External Dimensions485 × 485 × 1120 mm
Power3.1 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Timer Range0–120 min
Design Temp/Pressure138 °C / 0.25 MPa
Basket SizeΦ360 × 240 mm (2 pcs)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-100G
Instrument TypeVertical
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsØ400 mm × 850 mm
Chamber Volume100 L
External Dimensions485 mm × 605 mm × 1290 mm
Sterilization Power4.5 kW
Drying Power1.0 kW
Voltage220 V ±10%, 50 Hz ±2%
Sterilization Timer4–120 min
Drying Timer30–240 min
Safety Design Pressure0.25 MPa
Safety Design Temperature138 °C
Basket DimensionsØ360 mm × 240 mm × 3 units
Cold Air PurgeAutomatic
SealingSelf-expanding silicone gasket
Door MechanismHandwheel-operated with safety interlock
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield (BOXUN)
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBXW-SD
Instrument TypeHorizontal
Max Temperature131 °C
Max Pressure0.2 MPa
Chamber DimensionsØ472 mm × 1025 mm
External Dimensions764 mm × 1460 mm × 1590 mm
Chamber Volume150 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-70A
Instrument TypeVertical Autoclave
Maximum Temperature135 °C
Maximum Working Pressure0.22 MPa
Chamber DimensionsØ400 mm × 720 mm
Chamber Volume75 L
External Dimensions485 mm × 605 mm × 1170 mm
Power Supply220 V ±10%, 50 Hz ±2%
Rated Power3.5 kW
Timer Range0–120 min
Safety Design Pressure0.25 MPa
Safety Design Temperature138 °C
Basket DimensionsØ360 mm × 280 mm × 2 units
Control ModesFast Exhaust / Slow Exhaust / No Exhaust
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-75G
Instrument TypeVertical
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsØ400 mm × 720 mm
Chamber Volume75 L
External Dimensions485 mm × 605 mm × 1190 mm
Sterilization Power3.5 kW
Drying Power0.8 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Design Temp/Pressure138 °C / 0.25 MPa
Sterilization Timer4–120 min
Drying Timer30–240 min
Basket SizeØ360 mm × 280 mm × 2 units
Safety FeaturesAutomatic cold-air purge, self-sealing gasket, overpressure relief, low-water alarm, dry-run protection, dual-limit temperature cutoff, interlocked handwheel door
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-75SII
Instrument TypeVertical
Maximum Temperature135 °C
Maximum Working Pressure0.22 MPa
Chamber Diameter × HeightΦ400 mm × 720 mm
Chamber Volume75 L
External Dimensions (W×D×H)485 mm × 485 mm × 1190 mm
Power Supply220 V ±10%, 50 Hz ±2%
Rated Power3.5 kW
Sterilization Timer Range0–120 min
Design Temperature/Pressure138 °C / 0.25 MPa
Safety FeaturesAutomatic cold-air purge, self-sealing gasket, low-water level alarm, overpressure relief valve, overtemperature protection, door interlock system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelYXQ-LS-18SI
Instrument TypePortable
Max Temperature126 °C
Max Pressure0.142 MPa
Chamber DimensionsΦ280 × 290 mm
External DimensionsΦ390 × 530 mm
Chamber Volume18 L
Power2 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Operating/Design Temp.126 °C / 128 °C
Operating/Design Pressure0.142 MPa / 0.165 MPa
Timer Range0–60 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelBXM-60VF
Instrument TypeVertical Steam Sterilizer
Maximum Temperature150 °C
Maximum Working Pressure0.38 MPa
Chamber DimensionsØ400 × 635 mm
External Dimensions585 × 750 × 1075 mm
Chamber Volume60 L
Temperature Uniformity±0.3 °C
Temperature Fluctuation< +1 °C
Sterilization Time Range0–120 min (extendable to 6000 min)
Drying Temperature Range80–130 °C
Melting/Soaking Range50–100 °C
Holding Range40–60 °C
Power Input4.8 kW
Voltage220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Conditions5–40 °C, 20–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoxun
OriginShanghai, China
ModelBXW-JDM
TypeHorizontal
Max Temperature138 °C
Max Working Pressure0.242 MPa
Chamber Dimensions671 × 600 × 600 mm
External Dimensions927 × 1236 × 1780 mm
Chamber Volume240 L
Design Pressure (Chamber)−0.1 to 0.26 MPa
Jacket Design Pressure0.26 MPa
Pulse Range0–99 cycles
Pulse Amplitude (Positive)0.065–0.09 MPa
Pulse Amplitude (Negative)−0.05 to −0.09 MPa
Air Removal Efficiency>99% (≥3 pulses)
Vacuum Leakage Rate<0.13 kPa/min
Drying Time Range0–9999 s
Safety Valve Set Pressure0.25 MPa
Reseat Pressure0.22 MPa
Steam SupplyIntegrated electric steam generator or external source (0.3–0.5 MPa)
Compressed Air Supply0.5–0.7 MPa
Water Supply Pressure0.15–0.30 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield (BOXUN)
OriginShanghai, China
ModelYXQ-LS-75G
Instrument TypeVertical
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsØ400 × 720 mm
Chamber Volume75 L
External Dimensions485 × 605 × 1190 mm
Sterilization Power3.5 kW
Drying Power0.8 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Sterilization Timer4–120 min
Drying Timer30–240 min
Safety Design Pressure/Temperature0.25 MPa / 138 °C
Basket SizeØ360 × 280 mm × 2 pcs
MaterialSUS304 stainless steel chamber, door, and baskets
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield (BOXUN)
OriginShanghai, China
ModelBXM-110VF
Instrument TypeVertical Autoclave
Max Temperature150 °C
Max Pressure0.38 MPa
Chamber DimensionsØ400 × 835 mm
External Dimensions585 × 750 × 1275 mm
Chamber Volume110 L
Temperature Uniformity±0.3 °C
Temperature Fluctuation< +1 °C
Sterilization Time Range0–120 min (extendable to 6000 min)
Drying Temp Range80–130 °C
Melting Temp Range50–100 °C
Holding Temp Range40–60 °C
Power Input5.4 kW
Voltage220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Conditions5–40 °C, 20–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelBXM-100M
Instrument TypeVertical Steam Sterilizer
Maximum Temperature135 °C
Maximum Working Pressure0.22 MPa
Chamber DimensionsØ400 × 870 mm
External Dimensions750 × 800 × 1180 mm
Chamber Volume100 L
Heating Power6.8 kW
Power Supply~220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Conditions5–40 °C, 20–80 % RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-50G
Instrument TypeVertical Autoclave
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsØ400 × 640 mm
Chamber Volume50 L
External Dimensions485 × 605 × 1120 mm
Sterilization Power3.2 kW
Drying Power0.8 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Design Temp/Pressure138 °C / 0.25 MPa
Sterilization Timer Range4–120 min
Drying Timer Range30–240 min
Basket DimensionsØ360 × 240 mm (2 pcs)
Safety FeaturesAuto cold-air purge, overpressure relief, low-water alarm, dry-run protection, overtemperature cutoff, self-sealing gasket, interlocked manual door
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelBXM-110VE
Instrument TypeVertical Autoclave
Max Temperature150 °C
Max Pressure0.38 MPa
Chamber DimensionsØ400 × 835 mm
External Dimensions535 × 640 × 1275 mm
Chamber Volume110 L
Temperature Uniformity±0.5 °C
Temperature Fluctuation< +1 °C
Sterilization Temp Range105–135 °C
Melting Temp Range50–100 °C
Holding Temp Range40–60 °C
Sterilization Time Range0–120 min (customizable up to 6000 min)
Melting/Holding Time Range0–6000 min
预约 FunctionUp to 100 h
Heating Power3.5 kW
Power Supply~220 V ± 22 V, 50 Hz ± 1 Hz
Operating Ambient5–40 °C, 20–80% RH
Cooling SystemStandard air-cooling + secondary water-cooling + condenser
Safety ProtectionsOvertemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection
User Access LevelsEngineer / Administrator / Operator (3-tier permission management)
InterfaceCapacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelBXW-SD-A/G
Instrument TypeHorizontal
Max Temperature131 °C
Max Pressure0.22 MPa
Chamber DimensionsØ600 × 1050 mm
External Dimensions911 × 1432 × 1803 mm
Chamber Volume280 L
Power Supply380 V / 50 Hz
Heating Power (A-type)13 kW
Heating Power (G-type)14.5 kW
ComplianceDesigned for GLP-compliant sterilization workflows, compatible with ISO 17665-1, EN 285, and GB 8599 standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelYXQ-30SII
Instrument TypeVertical
Max Temperature135 °C
Max Pressure0.22 MPa
Chamber DimensionsΦ300 × 485 mm
Chamber Volume30 L
External Dimensions445 × 445 × 900 mm
Power2.3 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Operating Temperature Range105–135 °C
Operating Pressure Range0.07–0.22 MPa
Timer Range0–120 min
Safety Design Pressure0.25 MPa
Safety Design Temperature138 °C
Basket DimensionsΦ280 × 340 mm (1 unit)
MaterialSUS304 stainless steel chamber, door, and basket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBXM-30R
Instrument TypeVertical
Maximum Temperature126 °C
Maximum Pressure0.14 MPa
Chamber DimensionsΦ300 × 420 mm
External Dimensions395 × 395 × 780 mm
Chamber Volume29 L
Power Rating2 kW
Voltage/Frequency220 V ±10%, 50 Hz ±2%
Operating/Design Temp.126 °C / 128 °C
Operating/Design Pressure0.14 MPa / 0.165 MPa
Timer Range0–120 min
Basket DimensionsΦ280 × 340 mm (1 unit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
ModelBXM-150M
Instrument TypeVertical Steam Sterilizer
Max Temperature135 °C
Max Working Pressure0.22 MPa
Chamber DimensionsØ500 × 870 mm
External Dimensions850 × 910 × 1180 mm
Chamber Volume150 L
Sterilization Temp Range105–135 °C
Drying Temp Range102 °C
Melting Temp Range40–100 °C
Holding Temp Range25–85 °C
Sterilization Time Range4–120 min
Drying Time Range0–999 min
Melting/Holding Time Range0–999 min
Delay StartUp to 99 h 60 min
Design Pressure0.25 MPa
Drying Residual Moisture<1%
Heating Power10.5 kW
Power Supply380 V ±38 V, 50 Hz ±1 Hz
Ambient Operating Conditions5–40 °C, 20–80% RH
Chamber & Basket MaterialSUS304 Stainless Steel