| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 39.2 MPa |
| Flow Accuracy | ≤0.075% RSD |
| Injection Volume Range | 0.1–50 µL |
| Sample Tray Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 65 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromasterUltra Rs |
| Instrument Category | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–2.5 mL/min |
| Maximum System Pressure | 140 MPa |
| Flow Precision | ≤0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–20 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 90 °C |
| UV-Vis Wavelength Range | 100–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan (manufactured by Hitachi High-Tech Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Volume Range | 0.1–100 µL |
| Autosampler Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ChromAssist Database Edition |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) System Software |
| Deployment Options | Standalone & Networked |
| Regulatory Compliance | FDA 21 CFR Part 11, ALCOA+ Principles, ISO/IEC 17025 Annex A.3, ICH GCP, USP <1058> Analytical Instrument Qualification |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Operating Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Sample Injection Positions | 200 |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | GL Sciences Inc. & Hitachi High-Tech Corporation |
| Column Type | Reversed-Phase C18, C8, NH₂ |
| Packing Material | Fully Porous Silica-Based Particles (1.9–5 µm) |
| Endcapped | Yes |
| Pore Size | 100 Å (standard), 120 Å (wide-pore variants available) |
| Surface Area | ~300 m²/g |
| Carbon Load | 12–18% (C18), 8–12% (C8), 4–6% (NH₂) |
| pH Stability | 1.5–10.0 (C18/C8), 2.0–8.5 (NH₂) |
| Max. Pressure | 600 bar |
| Temperature Range | 5–60 °C |
| Dimensions | 50–250 mm × 2.1–4.6 mm ID |
| Particle Size Options | 1.9, 3, and 5 µm |