| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Excitation Source | Xenon Arc Lamp |
| Monochromator Type | Dual Grating |
| Slit Width Range | 1–20 nm |
| Typical S/N Ratio (Water Raman, 350 nm ex/397 nm em) | ≥450:1 |
| Detection Limit (Fluorescein in Aqueous Solution) | ≤1 × 10⁻¹² mol/L |
| Lamp Lifetime | ≥2,000 hours |
| Scan Speed | Up to 60,000 nm/min |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Compliance | ISO/IEC 17025-compatible optical validation protocols, ASTM E275 and E387 spectral performance standards |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 39.2 MPa |
| Flow Accuracy | ≤0.075% RSD |
| Injection Volume Range | 0.1–50 µL |
| Sample Tray Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 65 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | COM-28/28S |
| Measurement Range | −200 mV to +2000 mV |
| Potential Resolution | 0.1 mV |
| Display | 4.3-inch TFT LCD touchscreen (Chinese UI) |
| Data Storage | 50 internal records + up to ~9,900 via USB flash drive |
| Dimensions | 255 mm (W) × 290 mm (D) × 420 mm (H) |
| Optional accessories | C-1712 autosampler (12-position), photometric titration unit, dual external burettes |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EA1280 |
| Configuration | Benchtop |
| Instrument Type | Conventional ED-XRF |
| Application Scope | General-Purpose |
| Elemental Range | Al (Z=13) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <150 eV (Mn Kα) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromasterUltra Rs |
| Instrument Category | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–2.5 mL/min |
| Maximum System Pressure | 140 MPa |
| Flow Precision | ≤0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–20 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 90 °C |
| UV-Vis Wavelength Range | 100–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | U-5100 |
| Optical System | Ratio-Beam Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Scanning Speed | 12,000 nm/min |
| Standard Sample Holder | Automatic 6-Cell Carousel (10 mm square cuvettes) |
| Light Source | Pulsed Xenon Lamp |
| Display | Backlit LED, 320 × 240 dots |
| Dimensions (W×D×H) | 355 × 425 × 235 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V, 50/60 Hz, 60 VA |
| Brand | Hitachi |
|---|---|
| Origin | Japan (manufactured by Hitachi High-Tech Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Volume Range | 0.1–100 µL |
| Autosampler Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromAssist Data Station |
| Pricing | Upon Request |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ChromAssist Database Edition |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) System Software |
| Deployment Options | Standalone & Networked |
| Regulatory Compliance | FDA 21 CFR Part 11, ALCOA+ Principles, ISO/IEC 17025 Annex A.3, ICH GCP, USP <1058> Analytical Instrument Qualification |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | AQ-300 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Dimensions (W × D) | 310 mm × 270 mm |
| Interface | Dual RS-232C ports |
| Compliance | Designed for ISO 8533, ASTM E203, and USP <921> moisture determination protocols |
| Software Integration | Compatible with PC-based data acquisition and GLP-compliant reporting systems |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Operating Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Sample Injection Positions | 200 |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | MOICO-A19 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Display | 8.4-inch Color TFT Touchscreen with 16-Step Tilt Adjustment |
| Data Storage | USB Flash Drive Interface |
| Output | Built-in 58-mm Thermal Printer |
| Simultaneous Analysis | Up to 4 Independent Moisture Determinations |
| Stirrer Speed Control | 40 Adjustable Steps via LED Indication |
| Electrolytic Cell | Single-Chamber Coulometric Cell (No Catholyte or Diaphragm Required) |
| Status Indication | Tri-color LED + Dual-color Operation LED |
| Audio Guidance | Integrated Voice Prompt System |
| Blank Subtraction | Rapid Automatic Blank Compensation |
| Brand | Hitachi |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | UH4150AD+ |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–2000 nm |
| Wavelength Accuracy | ±0.2 nm (UV-Vis), ±1.0 nm (NIR) |
| Wavelength Repeatability | ±0.1 nm (UV-Vis) |
| Spectral Bandwidth | UV-Vis: auto-adjustable up to 14.4 nm, manually selectable from 0.01–8 nm |
| NIR | auto-adjustable up to 36 nm, manually selectable from 0.1–20 nm |
| Stray Light | ≤0.00005% at 220 nm (NaI), ≤0.00004% at 370 nm (NaNO₂) |
| Photometric Range | 8 Abs (UV-Vis), 7 Abs (NIR) |
| Data Mode | Optical Density (O.D.) |
| Multi-scan Capability | Wavelength-range-dependent scan speed & neutral density filter selection |
| Resolution Modes | Four-step high-resolution processing (High/Medium/Standard/Low) |
| ND Filter Wheel | Automatic insertion of five calibrated neutral density filters |
| Detector Calibration | Full 0%T baseline acquisition across measurement range |
| High-Absorbance Calibration | Dual-mode correction (negative transmittance compensation & offset adjustment) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Excitation Source | Xenon Arc Lamp |
| Monochromator | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Wavelength Scanning Speed | Up to 60,000 nm/min |
| Typical Detection Limit (Fluorescein) | 1 × 10⁻¹³ mol/L |
| Lamp Lifetime | ≥2,500 hours |
| Software Platform | FL Solutions v3.x (with ASTM E2899-compliant audit trail, USP <1058> validated operation mode) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UH4150 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.1 nm (UV-Vis) |
| Spectral Bandwidth | UV-Vis: Auto-adjustable up to 14.4 nm |
| NIR | Auto-adjustable up to 36 nm |
| Stray Light | ≤0.00008% at 220 nm (NaI) |
| Scan Speed | Up to 1200 nm/min (1 nm data interval) |
| Beam Geometry | Collimated Parallel Beam |
| Detector Switching | Seamless dual-detector transition with minimized absorbance discontinuity |
| Integrating Sphere Options | Multiple 60 mm spheres (BaSO₄ or Spectralon® coating), optional 150 mm sphere and goniometric absolute reflectance accessory |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | AQV-300 |
| Titration Method | Fully Automatic Volumetric Karl Fischer Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Dimensions (W × D) | 310 mm × 270 mm |
| Interface | Dual RS-232C ports |
| Compliance | Designed for GLP-compliant environments |
| Software Integration | Compatible with standard PC-based data acquisition and balance synchronization |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–2600 nm |
| Wavelength Accuracy | ±0.1 nm |
| Spectral Bandwidth | 0.1 / 0.5 / 1 / 2 / 4 / 5 nm |
| Automation Level | Motorized Wavelength Scanning |
| Monochromator Configuration | UH3900S — Single Monochromator |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–3300 nm |
| Wavelength Accuracy | ±0.05 nm (UV-Vis), ±0.2 nm (NIR) |
| Spectral Bandwidth | UV-Vis: 0.1, 0.2, 0.5, 1, 2, 5, 10 nm |
| NIR | 0.25, 0.5 nm |
| Wavelength Scanning Mode | Automatic |
| Slit Control | Motorized continuous variable slit |
| Optical System | Etched holographic diffraction grating, high-flux monochromator |
| Software | UV Solutions Plus with customizable reporting, data table view, instrument performance verification module |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator | Custom High-Resolution Grating (Motor-Driven for ZA4800) |
| Detector | Photomultiplier Tube (Dual-Detector Configuration) |
| Background Correction | Polarized Zeeman Correction (Full-Wavelength, Real-Time) |
| Baseline Stability | ≤ 0.0004 Abs / 30 min |
| Element Simultaneity | Up to 12 Elements in Sequential Mode (ZA4800) |
| Compliance | ASTM E1756, ISO 8289, USP <731>, FDA 21 CFR Part 11 (Audit Trail & Electronic Signature Ready), GLP/GMP-Ready Software Architecture |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | EEM View |
| Pricing | Upon Request |
| Dispersive Element | Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | GL Sciences Inc. & Hitachi High-Tech Corporation |
| Column Type | Reversed-Phase C18, C8, NH₂ |
| Packing Material | Fully Porous Silica-Based Particles (1.9–5 µm) |
| Endcapped | Yes |
| Pore Size | 100 Å (standard), 120 Å (wide-pore variants available) |
| Surface Area | ~300 m²/g |
| Carbon Load | 12–18% (C18), 8–12% (C8), 4–6% (NH₂) |
| pH Stability | 1.5–10.0 (C18/C8), 2.0–8.5 (NH₂) |
| Max. Pressure | 600 bar |
| Temperature Range | 5–60 °C |
| Dimensions | 50–250 mm × 2.1–4.6 mm ID |
| Particle Size Options | 1.9, 3, and 5 µm |
| Brand | Hiranuma |
|---|---|
| Origin | Japan |
| Model | COM-A19 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Measurement Range | −2000 to +2000 mV |
| Display Resolution | 0.1 mV |
| Touchscreen | 8.4-inch Color LCD with 16-step Adjustable Viewing Angle |
| Stirrer Speed Control | 40-step Adjustable |
| Stirring Mode | Continuous Forward/Reverse Rotation |
| Status Indication | Dual-color LED Operational Indicator & Tri-color LED System Status Light |
| Data Interface | USB Port + LAN (Web-based Remote Access) |
| Built-in Thermal Printer | 58 mm Paper Width |
| Titration Head Design | Plug-and-Play Reagent Cartridge System |
| Audio Feedback | Voice Prompt Function |