| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/61 |
| Test Chambers | 6 × 10 cm² |
| Sample Types | Films & Rigid/ Flexible Packages (up to 3 L) |
| OTR Range (per chamber) | 0.5–1000 cm³/m²·day |
| Combined 6-chamber range | 0.1–200 cm³/m²·day |
| RH Control | 0–90% RH (film), 100% RH on O₂ side only |
| Temperature Range | Ambient to 65°C |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-C® 4/30 |
| Detection Limit | 0.5 cm³/(m²·day) |
| Measurement Principle | Modulated Infrared Spectroscopy |
| Compliance | ASTM F2476 |
| Test Chamber | Dual independent horizontal chambers with interchangeable fixtures |
| Temperature Control | Automated, ±0.1 °C stability |
| Flow Control | Fully automated mass flow regulation |
| Throughput | High—real-time CO₂ concentration monitoring enables rapid equilibrium detection |
| Sample Types | Films, laminates, pouches, trays, bottles, and rigid containers |
| Range | 0.5–8,000 cm³/(m²·day), extendable to ~72,000 cm³/(m²·day) via area reduction factor (×9) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® 1/50 |
| Test Range | 0.1–100 cm³/m²·day |
| Temperature Range | 5–50 °C (W-type configuration) |
| Humidity Range | 35–90 %RH (standard), up to 100 %RH (W-type) |
| Test Area | 2 chambers × 50 cm² |
| Repeatability | ±0.05 g/m²·day or ±3 % of reading (whichever is greater) |
| RH Sensor Accuracy | ±3 %RH |
| Carrier Gas | Dry nitrogen or oil-free compressed air |
| Compliance | ASTM E398, ISO 15106-1, GB/T 30412–2013 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PERMATRAN-W® Model 101K |
| Quotation | Upon Request |
| Test Range | 500–100,000 g/m²·day |
| Test Temperature | 20–50 °C with Automatic Temperature Control |
| Atmospheric Pressure Compensation | Standard |
| Flow Rate Compensation | Standard |
| Number of Test Cells | 6 |
| Cell Area | 10 cm² per cell |
| Compliance | ASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34 |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Range | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 × 10.8 cm |
| Package Capacity | Up to 3 L |
| Compliance | ASTM F1249, ISO 15106-2, JIS K7129, TAPPI T557, GB/T 26253–2010, GB/T 31355–2014, YBB00092003–2015 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34G |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber Area | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Package Capacity | Up to 3 L |
| Sensor Type | Coulometric Moisture Detector |
| Sealing Technology | TruSeal™ Nitrogen Perimeter Purge |
| Interface | Touchscreen + Ethernet/USB |
| Data Storage | Internal (100 test records) + PermNet® Lite remote software support |
| Compliance | ASTM F1249, ISO 15106-3, TAPPI T464, USP <671>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/61 |
| Test Principle | Infrared Detection (ASTM F1249-compliant) |
| Sample Capacity | 6 independent test cells (10 cm² each) |
| WVTR Range (per cell) | 0.05–500 g/m²·day |
| Combined 6-cell Range | 0.01–85 g/m²·day |
| RH Control | 35–90% RH (film), up to 100% RH (container mode) |
| Temperature Range | Ambient to 65°C |
| Calibration Traceability | NIST-traceable standard films |
| Sample Types | Flat films (10.8 × 10.8 cm), rigid/flexible packages (≤3 L) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ProSpect TS/TD-30 |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Application | Real-time milk composition analysis |
| Automation Level | Fully Automatic |
| Analysis Time | 20–30 seconds per measurement |
| Spectral Range | 850–1100 nm |
| Repeatability | ±0.5–2 mm (pathlength-dependent optical consistency) |
| Accuracy | ±35–50 µm (wavelength calibration stability) |
| Brand | CK |
|---|---|
| Origin | Austria |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MoleMax HD |
| Pricing | Upon Request |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | M-VS 3000 |
| Cutting Die Diameter | 45 mm |
| Max. Sample Thickness | ≤ 20 mm |
| Volume Reproducibility | ±0.1 % |
| Nominal Sample Volume | ~15 cm³ |
| Adjustable Cutting Cycle Time | 1–15 s |
| Dimensions (H×W×D) | 600 × 430 × 380 mm |
| Net Weight | ~50 kg |
| Minimum Operating Air Pressure | 5.0 bar |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | MDR 3000 |
| Standard Compliance | ISO 6502, ASTM D5289, DIN 53529 |
| Cavity Type | Sealed Dual-Conical |
| Drive System | Direct-Drive DC Servo Motor |
| Oscillation Frequency | 1.667 Hz |
| Amplitude Range | Software-Controlled ±0.01° to 5° (mechanical fixed option: 0.5°) |
| Temperature Range | Ambient to 232 °C |
| Measured Parameters | Torque (dN·m), Temperature (°C), Frequency (Hz), Strain (%), Derived Moduli (S′, S″, S*, tan δ) |
| Cavity Material | Hardened & Polished Stainless Steel |
| Enclosure | Anodized Aluminum Alloy Housing |
| Control Interface | Dedicated PC with MonControl v5.x (32-bit Windows-based Analysis Suite) |
| Data Output | Real-time torque/temperature curves, modulus profiles, cure kinetics (ts1, tc50, tc90), hysteresis analysis |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | MV 3000 |
| Standards Compliance | ISO 289:2005, ASTM D1646, DIN 53523, BS 903 Part A58, JIS K6300, GOST 10722–76 |
| Rotor Options | Large rotor (38.10 mm), Small rotor (30.48 mm) |
| Rotational Speed | 2 rpm ± 0.02 rpm |
| Temperature Range | Ambient to 232 °C |
| Temperature Accuracy | ±0.03 °C |
| Measurement Units | Mooney Units (MU), °C / °F, min:min or min:sec |
| Test Modes | Mooney Viscosity, Mooney Scorch, Stress Relaxation, Mold Release Performance, Delta Mooney |
| Sealing | Long-life elastomeric seal assembly |
| Control System | Digital microprocessor-based PID temperature and torque control |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | PO 3000 Plastometer Aging Oven |
| Construction | Stainless Steel Enclosure |
| Heating Chambers | 4 Independent PID-Controlled Zones |
| Temperature Range | Ambient to 200 °C (Standard Operating Point: 140 ± 0.2 °C) |
| Temperature Recovery Time | ≤ 1 min after Sample Insertion |
| Max. Sample Capacity | 48 specimens (12 per Tray × 4 Trays) |
| Air Exchange Rate | 0–120 air changes/hour (adjustable) |
| Chamber Dimensions (W × H × D) | 500 × 120 × 280 mm |
| Max. Power Consumption | 2.5 kW |
| Compliance | ASTM D3194, BS 903-A59 |
| Safety Features | Overheat Protection, Stability Monitoring, Timeout Alert |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | V-MV 3000 |
| Standards Compliance | ISO 289:2005, ASTM D1646, DIN 53523, DIN 53525 Parts 1–3, BS 903 Part A58, AFNOR T43-00/005, JIS K6300, GOST 10722–76 |
| Rotor Options | Large rotor (38.10 mm), Small rotor (30.48 mm) |
| Rotational Speed Range | 0–50 rpm, adjustable in 0.01 rpm increments |
| Temperature Range | Ambient to 232 °C, control accuracy ±0.03 °C |
| Measurement Units | Mooney Units (MU), °C / °F, time (min:min or min:sec) |
| Test Modes | Mooney viscosity, Mooney scorch, stress relaxation, mold release evaluation, Delta Mooney, variable Mooney, stepwise stress relaxation, programmable multi-step test sequences |
| Sealing | Long-life precision sealing system |
| Application Scope | QC, R&D, and production fast-check for raw rubber, compounded elastomers, and thermoplastic elastomers (TPEs) |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8005 |
| Pricing | Upon Request |
| Brand | Morphious |
|---|---|
| Origin | Italy |
| Model | Morphious C1 |
| Detection Principle | High-Resolution Color Imaging + Real-Time Image Processing |
| Pixel Resolution | 1600 × 1200 @ 60 fps |
| Pixel Size | 4.5 µm |
| Minimum Detectable Particle Size | 20 µm |
| Throughput Range | 2–60 kg/h (material- and size-dependent) |
| Optical Configuration | Triple-CCD Color Calibration Module |
| Software Platform | Windows 10 or later, Mishell®-powered analysis engine |
| System Dimensions | 500 × 600 × 500 mm (L×W×H) |
| Weight | 32 kg |
| Power Consumption | 18 W |
| Operating Temperature | 15–40 °C |
| Integrated Auto-Cleaning Unit | Yes |
| Connectivity | Gigabit Ethernet, USB 3.0, HDMI |
| Display | 17″ Low-Emission Monitor |
| Data Export | CSV, PDF, PNG, Excel-compatible reports |
| Compliance Ready | ASTM D7269, ISO 1874-2, USP <788>, GLP/GMP audit trail support (software-configurable) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EFS-20 |
| Pricing | Available Upon Request |
| Pressure Sensor Range | −0.1–1 MPa, Accuracy ≥ 0.05% FS |
| Safety Relief Valve Set Point | 0.5 MPa |
| Solenoid Valve Rating | ≥ 3 MPa, Response Time ≤ 10 ms |
| Vacuum Pump | Pumping Speed ≥ 2 L/s, Ultimate Vacuum ≤ 1.0 kPa, Inlet OD: 10 mm |
| Ignition System | Dual Electrodes, Transformer Output 13–15 kV |
| Exhaust Scrubbing Unit | Acid Gas Neutralization & Particulate Adsorption |
| Observation Module | Angled Optical Port with Adjustable LED Illumination |
| Control Hardware | Advantech Industrial PC |
| Software | Dedicated Flame Kinematics Acquisition & Post-Processing Suite |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | LEL-5L |
| Explosion Chamber Volume | 5 L ± 0.25 L |
| Maximum Operating Pressure | 2 MPa |
| Design Pressure | 3 MPa |
| Heating Furnace Max Temp | 200 °C (Design: 250 °C) |
| Temp Control Accuracy | ±0.1 °C |
| Ignition Voltage | 13–15 kV |
| Pressure Gauge Range | 0–3 MPa (Accuracy: ≤2% FS) |
| K-Type Thermocouple | ≥1100 °C Rated, Class II Accuracy |
| Vacuum Pump | ≥1 L/s Pumping Speed, Ultimate Vacuum ≤1.0 kPa, 6 mm OD Inlet |
| Control System | Advantech Industrial PC with Dedicated Flammability Testing Software |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | LEL-8L |
| Vessel Volume | 8 L ±10% |
| Maximum Operating Pressure | 2 MPa |
| Design Pressure | 3 MPa |
| Vessel Material | Dual-layer 316 stainless steel |
| Temperature Control | Integrated water-jacketed circulation |
| Pressure Measurement Range | 0–2 MPa |
| Ignition System | Dual tungsten-alloy ignition pins with 13–15 kV transformer |
| Temperature Sensor | K-type thermocouple, Class II accuracy, rated ≥1100 °C |
| Vacuum System | Rotary vane pump, pumping speed ≥2 L/s, ultimate vacuum ≤1.0 kPa, inlet port OD: 10 mm |
| Output Parameters | Peak explosion pressure (Pmax), maximum rate of pressure rise (dP/dt)max, initial temperature, time-resolved pressure/temperature profiles |
| Brand | MOTWANE |
|---|---|
| Origin | India |
| Model | PCRM-200S |
| Test Current | 100 A / 200 A DC |
| Measurement Range | 0.1 µΩ to 20 mΩ |
| Minimum Resolution | 0.1 µΩ |
| Accuracy | ±2% of reading |
| Measurement Method | Kelvin 4-wire |
| Display | Backlit 3½-digit LCD |
| Memory Capacity | 199 test records |
| Printer | Built-in thermal printer |
| Interface | USB |
| Power Supply | 230 V AC ±10%, 50 Hz or 12 V / 7.2 Ah rechargeable sealed lead-acid battery |
| Enclosure Rating | IP54 |
| Safety Compliance | EN 61010-1, EN 61326-1, CAT II |
| Operating Temperature | 0 °C to 55 °C |
| Dimensions (L×W×D) | 502 mm × 395 mm × 188 mm |
| Weight | ~14 kg |
| Key | Brand: AMETEK |
|---|---|
| Origin | USA |
| Model | MPC-9604 |
| Detector Type | Flow-through proportional counter (P-10 gas) |
| Effective Detection Area | 20 cm² |
| Max Sample Size | Ø2" × 1/8" or 5/16" thick |
| Measurement Modes | α-only, β-only, simultaneous α/β, sequential α-then-β |
| Cross-Talk | ≤1 count per 100,000 counts |
| Window | 80 μg/cm² ultra-thin polymer window |
| Window Replacement Time | ≤10 minutes |
| Shielding | 10 cm lead, 4π geometry |
| Gas System | Parallel independent flow paths per channel |
| Interlock | Automatic leak/break detection with system shutdown |
| Sample Access | Drawer-type modular design |
| Counting Method | Non-destructive, high-efficiency gas-flow counting |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MPD-01 |
| Price | USD 7,000 (FOB) |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Sampling Rate | 1 Hz |
| Power Consumption | 1 kW |
| Brand | MRG |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GREASE THIEF© |
| Pricing | Upon Request |
| Dimensions | 82 × 49 × 74 cm |
| Weight | 57 kg |
| Power Supply | 240 VAC, 50 Hz, 2.7 A |
| Operating Temperature Range | 15–27 °C |
| Measured Parameter | Grease Extrusion Index (% New Grease) |
| Sample Mass | 0.25 g |
| Sampling Standard | ASTM D7718 |
| Environmental Control | Microprocessor-based PID controller with thermocouple temperature sensor |
| Consumables | 12 pre-loaded disposable kits included |
| Data Storage | 512 MB SD card |
| Data Interface | RS-232 serial output |
| Display | 2.4-inch LCD with 20-key membrane keypad |
| Brand | MRG |
|---|---|
| Origin | USA |
| Model | GREASE THIEF |
| Compliance | ASTM D7718 (Standard Practice for Sampling In-Service Lubricating Grease) |
| Application | Manual, non-invasive grease extraction from sealed or confined bearing housings, gearboxes, and rotating equipment |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MS2100 |
| Pricing | Upon Request |
| Measurement Range (aw) | 0.000–1.000 aw |
| Accuracy | ±0.015 aw |
| Repeatability | ±0.005 aw |
| Resolution | 0.001 aw |
| Moisture Content Range | 0–100% w/w |
| Moisture Accuracy | ±2% abs |
| Moisture Repeatability | ±0.5% abs |
| Moisture Resolution | 0.1% |
| Sample Temperature Range | −40 to +85 °C |
| Power Supply | Internal rechargeable battery (4 h continuous operation |
| Intrinsic Safety Rating | Ia, Class 1, Groups A/B/C/D |
| Communication Interface | RS-232 & RS-485 dual-port |
| Data Storage | 100 sample records with timestamp, auto/manual logging |
| Calibration Options | Saturated salt solutions (ERH method) or certified reference standards |
| Sensor Principle | Capacitive polymer humidity sensor with integrated temperature compensation |
| Data Retention | Non-volatile memory (2 MB), retains all settings and logs after power loss |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ST300 |
| Pricing | Upon Request |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MSK-ESC-R2R |
| Pricing | Upon Request |
| Electrode Configuration | Linear 5-needle spinneret |
| Coating Width | 160 mm |
| Substrate Travel Speed | 2.2–117.2 mm/s |
| Heating Platform Max Temp | 100 °C |
| Temperature Control Accuracy | ±1 °C (PID) |
| High-Voltage Output | 0–50 kV, max 1 mA |
| Needle OD | 0.9 mm |
| Needle ID | 0.6 mm |
| Needle Length | 12 mm |
| Needle Spacing | 25 mm |
| Needle-to-Heater Distance Range | 70–235 mm |
| Syringe Pump Flow Rate | 0.1–45 mm/min (linear displacement) |
| Syringe Volume | 250 mL |
| System Footprint | 805 × 435 × 565 mm (L×W×H) |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MT Trees Ring Analysis Measurement System |
| Price | Upon Request |
| Brand | MicrOptik |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-Type |
| Price Range | USD 42,000 – 70,000 |
| Maximum Film Width | 1200 mm |
| Production Capacity | 400 kg/h |
| Layer Configuration | 1–7 layers |
| Primary Resins | Polyolefins (PP, PE), Barrier Polymers (EVOH, PA, PVDC) |
| Brand | MultiGel |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MC100 |
| Pricing | Upon Request |