Industry-specific Instruments
Filter
Showing 3571–3600 of 6344 results
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NBC-1002 |
| Price | USD 28,000 (FOB Beijing) |
| Excitation Wavelength | 785 nm |
| Laser Power | ≤500 mW (adjustable) |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | ≤8 cm⁻¹ |
| Detector | TE-cooled CCD |
| Battery Life | ≥6 hours (continuous operation) |
| Connectivity | Wi-Fi 5 (802.11ac), Bluetooth 5.0, USB-C |
| Data Storage | Internal 64 GB + cloud-sync capable |
| Compliance | Meets ISO/IEC 17025 calibration traceability requirements |
| Brand | NeuronBC |
|---|---|
| Model | NSTS-1000 |
| Origin | Beijing, China |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 120 W |
| Pump Speed Range | 20–300 rpm |
| Height of Suspension Assembly | 45 cm |
| Net Weight | 18 kg |
| Construction Material | Electropolished Stainless Steel (316L-grade compatible) |
| Motor Type | Brushless DC Motor with Continuous Speed Control |
| Display | High-Resolution Color Touchscreen Interface |
| Safety Protections | Overcurrent, Overvoltage, Overload, Stall Detection, Adjustable Pressure-Limit Protection |
| Tubing Clamping | One-Touch Linear Pump Head with Quick-Release Cap |
| Compliance | Designed to support USP <71>, EP 2.6.1, and ISO 11737-1 workflows |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Model | RIT-1000 |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GAMP 5 |
| Test Principle | Pressure Decay Method |
| Port Compatibility | Universal RTP interface (ISO 14644-3 compliant flange dimensions) |
| Sensitivity | ≤0.1 Pa/s pressure decay detection threshold |
| Operating Environment | ISO Class C/D cleanrooms |
| Form Factor | Portable benchtop unit with integrated pressure sensor and vacuum pump |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-200 |
| Price | USD 25,000 (FOB) |
| Measurement Range | 0.1–30,000 mg/L TOC |
| Detection Principle | Catalytic Combustion Oxidation + Non-Dispersive Infrared (NDIR) Detection |
| Sample Throughput | ≤60 samples/hour |
| Oxidation Temperature | 680–900 °C (adjustable) |
| NDIR Detector Resolution | 24-bit |
| Control System Architecture | 32-bit embedded signal processing |
| Gas Flow Monitoring | Integrated mass flow sensor with auto-leak detection |
| Sample Introduction | Programmable syringe pump with 0.1–5 mL injection volume |
| Compliance | Designed to meet ISO 8466-2, EPA Method 415.3, and ASTM D7573 requirements |
| Brand | NeuronBC |
|---|---|
| Model | V4.0 |
| Display | 5.7″ backlit digital LCD |
| Interface | Chinese-language GUI |
| Data Visualization | Real-time test curve and numerical display |
| Processing | Dual-core embedded controller |
| Software | PC-based upper-computer software with audit trail capability |
| User Management | Multi-level password-protected access control |
| Safety Protection | Automatic pressure-limiting and overpressure cutoff for filter safeguard |
| Test Methods | Forward flow (diffusion), bubble point, and water intrusion (for hydrophobic membranes) |
| Compliance Support | Configurable report generation aligned with FDA 21 CFR Part 11 and EU Annex 11 requirements |
| Reporting | Optional integrated thermal printer interface |
| Membrane Compatibility | Flat-sheet membranes, cartridge filters, and disc filters |
| Origin | Beijing, China |
| Price | USD 5,600 (FOB) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | V4.0 |
| Price | USD 5,300 (FOB) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar |
| Test Accuracy | Bubble Point ±50 mbar |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Water Intrusion Range | 0.01–30 mL/min |
| Display | 5.7″ monochrome TFT LCD with backlight |
| Data Storage | 500 test records |
| Interface | RS232 serial port |
| Language Support | English & Chinese |
| Operating Modes | Online & Offline |
| Environmental Class | ISO Class B or better |
| Weight | 7.5 kg |
| Dimensions (L×W×H₁×H₂) | 400 × 240 × 270 × 220 mm |
| Relative Humidity | 10–80% RH |
| Ambient Temperature | +5 °C to +40 °C |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V6.5 Audit-Trail |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar |
| Temperature Range | +5°C to +40°C |
| Relative Humidity | 10–80% |
| Dimensions (mm) | 400(D) × 240(W) × 270(H1) × 220(H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable parameters with timestamp |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Compliance | Fully aligned with FDA 21 CFR Part 11, ALCOA+ data integrity principles, and ISO 13485 / ASTM F838-22 / USP <1207> guidance for filter integrity testing |
| Brand | NeuronBC |
|---|---|
| Model | V6.5 |
| Origin | Beijing, China |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 (D) × 240 (W) × 270/220 (H1/H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusive Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Test Accuracy | ±4% |
| Bubble Point Range | 100–8,000 mbar |
| Diffusive Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable events with timestamped traceability |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Data Storage | ≥5,000 test records, USB backup of full datasets including real-time curves |
| Display | 7" high-resolution color touchscreen |
| Interface Options | RS232, USB, optional industrial fieldbus (e.g., Modbus TCP, Profibus DP) and analog I/O |
| Language Support | English / Chinese |
| Compliance | FDA 21 CFR Part 11, ALCOA+ principles, Annex 11 (EU GMP), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Operating Pressure Range | 100–10,000 mbar (150 psi) |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 480 × 300 × 190 mm |
| Weight | 10 kg |
| Compliance | CE Marked, FDA 21 CFR Part 11, GMP-Aligned Audit Trail & Electronic Signature Support |
| Display | 10-inch true-color touchscreen |
| Data Export | USB (raw test data, configuration files, audit logs) |
| Connectivity | RS232, USB |
| Sensor Accuracy | High-precision pressure transducers with low drift and extended pneumatic line compensation up to 100 m |
| Integrated Thermal Printer | Non-ink, particle-free, archival-grade print retention (>10 years) |
| User Management | Four-tier role-based access control with customizable permissions, mandatory electronic signatures, and password-protected login |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | WGT-1000 |
| Power Supply | DC 12 V, 20 W |
| Test Accuracy | Detects leaks equivalent to ≥300 µm aperture |
| Test Duration | 3–8 min |
| Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Noise Level | ≤50 dB(A) |
| Communication Method | Wi-Fi |
| Gas Source | Built-in sanitary air pump |
| Maximum Sealing Pressure | ≤200 kPa |
| Data Storage Capacity | >12,000 test records |
| Glove Identification | RFID or manual input |
| Enclosure Rating | IP65 |
| Weight | 4.2 kg |
| Display | Color touchscreen interface |
| Compliance | FDA 21 CFR Part 11, GMP, ISO 14644-7:2004, GB/T 25915.7–2010 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | WGT-1200 |
| Price | Upon Request |
| Power Supply | DC 12 V, 20 W |
| Built-in Battery | 12 V Li-ion |
| Detection Accuracy | Minimum Detectable Hole Size: 300 µm |
| Test Duration | 3–8 min |
| Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Noise Level | ≤50 dB(A) |
| Communication | Wi-Fi |
| Air Source | Integrated Sanitary-Grade Diaphragm Pump |
| Maximum Seal Pressure | ≤200 kPa |
| Data Storage Capacity | >12,000 test records |
| Data Storage Medium | Onboard Flash Memory |
| Glove Identification | RFID or Manual Entry |
| Unit Weight | 4.2 kg |
| Max. Controlled Test Units per Controller | 10 |
| Operating Time | Up to 8 h continuous / >48 h standby |
| User Accounts | 120 max |
| Predefined Test Protocols | 120 max |
| Access Control | Four-Tier Role-Based Permissions |
| Software Compliance | FDA 21 CFR Part 11 (Electronic Records & Signatures), GMP Annex 11, ALCOA+ Principles |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DD110M / DD110 / DD109M / DD109 |
| Quotation | Upon Technical Specification Review |
| Neutron Yield (DD110M) | 1 × 10¹⁰ n/s |
| Thermal Neutron Flux (DD110M) | 1 × 10⁷ n/cm²/s |
| Neutron Yield (DD109M) | 2 × 10⁹ n/s |
| Thermal Neutron Flux (DD109M) | 2 × 10⁶ n/cm²/s |
| Primary Neutron Energy | 2.5 MeV (D–D fusion) |
| Operational Mode | Continuous or Pulse-on-Demand (≥ 50 µs pulse width, optional) |
| Mean Time Between Maintenance | ≥ 2000 hours |
| Key Consumables | Replaceable deuterium target, vacuum pump assembly |
| Safety | Interlocked beam shutter, vacuum interlock, radiation-free at standby |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ND25 / ND40 |
| Pricing | Upon Technical Consultation |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Core Architecture | FPGA-Based Event-Driven Acquisition |
| Time Resolution | 100 ns (48-bit timestamp, range up to 325 days) |
| Timing Reference | TOF-zero synchronized absolute/relative timestamps |
| Compliance | Designed for neutron facility integration per IEC 61508 SIL-2 functional safety guidelines and ISO/IEC 17025-compliant data integrity workflows |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Neutronoptics |
| Pricing | Upon Request |
| Brand | New Chi Scientific (Scientz) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CSD01 |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | W Flex Tester |
| Pricing | Upon Request |
| Brand | Linetronic |
|---|---|
| Origin | Switzerland |
| Model | 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage compressor (–85 °C min) or single-stage compressor (–40 °C min) |
| Temperature Sensor | PT100 Class A |
| Detection Method | Coaxial fiber-optic IR pulse reflection with mirror-based crystallization monitoring |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Software | LabLink v.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail capability |
| Brand | Newton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NM200E |
| Pricing | Available Upon Request |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NGD-01 |
| Price | USD 3,950 (FOB) |
| Temperature Range | −20 to 30 °C |
| Temp. Resolution | 0.001 °C |
| Inter-Parallel Deviation | ±0.001 °C |
| Stirring Speed | 0–800 rpm (continuously adjustable) |
| Cold Bath Control Range | Ambient to −20 °C |
| Temperature Stability | ±0.05 °C |
| Data Acquisition Rate | 1 sample/sec |
| Power Consumption | 600 W |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NIJI-2 |
| Pricing | Upon Request |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | SO-260 |
| Instrument Type | Seed Flowability Tester |
| Moisture Measurement Range | 0–100% (optional integrated moisture module) |
| Weighing Resolution | 0.1 g |
| Sample Mass Capacity | 0–100 g |
| Heating Temperature Range | Ambient to 80 °C |
| Frame Dimensions | 750 × 750 × 2000 mm |
| Funnel Capacity | 37 L |
| Cylindrical Accumulation Chamber Volume | 49 L |
| Chamber Diameter | 500 mm |
| Chamber Height | 250 mm |
| Standard Discharge Orifice | DN60 |
| Optional Orifice Adapter | DN50 |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 5–6 bar |
| Bulk Density Range | 0.5–0.85 kg/L |
| Maximum Particle Size | 6 mm |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N. 14 |
| Coating Capacity | 2–14 t/h |
| Liquid Dosing Range | 0.3–2.6 mL/kg, 0.9–4.2 mL/kg, 2.7–6.3 mL/kg, 3.7–8.6 mL/kg |
| Dual-Liquid Capability | Yes |
| Compliance | JKI Federal Research Centre Certified |
| Construction | Stainless Steel Mixing Drum with Nylon-Brush Auger |
| Dosing Principle | Patented Niklas Metering System (Mechanical Seed Roller + Precision Liquid Metering Wheel) |
| Liquid Delivery | Centrifugal Pump with Overflow-Regulated Metering Trough and Recirculation Loop |
| Optional Features | Dust Extraction Unit, Cross-Flow Sieve, Compressed Air Interface (for Pneumatic Actuation), Dual-Bagging Nozzle Adapter (DN 150 mm) |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/01 |
| Instrument Type | Laboratory-scale seed coating system |
| Moisture Measurement Range (%) | 0–100 |
| Minimum Weighing Resolution (g) | 0.1 |
| Sample Mass Capacity (g) | 0–100 |
| Heating Temperature Range (°C) | Ambient to 80 |
| Power Supply | 3-phase, 400 V / 50 Hz, 2.0 kW |
| Dimensions (L×W×H) | 1200 × 700 × 1300 mm |
| Weight | 170 kg |
| Construction | Stainless steel working surface with four swivel casters |
| Dust Extraction | Integrated recirculating suction system with filter bag |
| Compressed Air Required | No |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/100 |
| Batch Capacity | 35–140 L |
| Throughput | 16 t/h |
| Control System | Integrated PLC with Weight & Time-Based Dosing |
| Liquid Delivery | Precision Metering Pumps with 20 L Load Cell System |
| Spray Nozzle | Fine Mist Dispenser at Parabolic Seed Flow Core |
| Compliance | Designed for ISO 9001-aligned seed treatment workflows and compatible with EU Plant Protection Product (PPP) Regulation (EC) No 1107/2009 application protocols |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/200 |
| Batch Capacity | 75–270 L |
| Throughput | 30 t/h |
| Control System | Integrated PLC with Weight & Time-Based Dosing |
| Liquid Dosing | Precision Metering Pumps + 20 L Weighing System |
| Powder Dosing | Synchronized Volumetric Feeders |
| Spray Nozzle | Fine-Mist Parabolic Distribution System |
| Compliance | Designed for ISO 9001-aligned seed treatment facilities, compatible with GLP/GMP documentation workflows |
| Brand | Niklas |
|---|---|
| Origin | Germany |
| Model | W.N.5/50 |
| Batch Capacity | 25–70 L |
| Throughput | 9 t/h |
| Control System | Integrated PLC with Weight- and Time-Based Dosing |
| Liquid Dosing | Precision Metering Pump with 20 L Weighing System |
| Powder Dosing | Synchronized Volumetric Feeder |
| Spray Nozzle | Fine-Mist Atomizer Positioned at Parabolic Seed Trajectory Center |
| Compliance | Designed for ISO 22000-aligned food-grade seed processing environments |
| Software | Recipe-Driven Batch Management with Storage for Multiple Seed Types and Formulations |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NIM-2 |
| Pricing | Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MDS-2008 |
| Instrument Type | On-line Dissolution Tester |
| Dissolution Vessels | 6 or 8 |
| Temperature Range | Ambient to 45.0 °C |
| Temperature Accuracy | ≤ ±0.2 °C |
| Rotation Speed Range | 25.0–250.0 rpm |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45.0 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 28 L |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | On-line Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Control Range | Ambient to 45 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤0.5 mm |
| Water Bath Volume | 32 L |
| Vessel Options | 250 mL and 1000 mL (amber glass option available) |
| Independent Temperature Monitoring | 14 built-in PT100 probes |
| User Interface | 10-inch color capacitive touchscreen |
| Method Storage Capacity | 144 protocols |
| Audit Trail Compliance | 3-tier user permission system with electronic signature support |
| Data Output | Built-in thermal printer + USB export (proprietary .scd format) |
| Automation Features | Auto-dosing module (simultaneous or sequential 8-vessel dosing), auto-level monitoring, voice status alerts, unattended pre-heating scheduling |