| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | HFRR |
| Frequency Range | 10–200 Hz |
| Stroke Range | 20 µm–2.0 mm |
| Load Capacity | 0–1.0 kg (via calibrated weights) |
| Maximum Friction Force | up to 10.0 N (amplitude-dependent) |
| Operating Temperature | ambient to 150 °C (up to 400 °C with optional high-power heating module) |
| Standard Counterface | 10.0 mm diameter × 3.0 mm thick steel disc |
| Standard Indenter | 6.0 mm diameter hardened steel ball |
| Compliance | ASTM D6079, ASTM D7688, ISO 12156-1, SH/T 0765–2021 |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ETM |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 100–1650 N |
| Maximum Contact Pressure | 3.5 GPa (standard steel test specimens) |
| Sliding Velocity | up to 3.5 m/s |
| Temperature Range | 10–150 °C |
| Sample Volume | 30 mL (10 mL with optional filler insert) |
| Operating System | Windows 10 |
| Safety Features | Dual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid |
| Power Supply | 100–240 V, 50/60 Hz, 1600 VA |
| Weight (main unit) | 52 kg |
| Dimensions (H × W × D) | 425 mm × 400 mm × 605 mm |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPR |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 0–2000 N |
| Contact Pressure | 0–3.2 GPa |
| Sliding/Rolling Ratio | 0–200% |
| Temperature Range | Ambient to 150 °C |
| Specimen Volume | 150 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | MTM2 |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Sample Volume | 10–35 mL |
| Load Range | 0–75 N |
| Contact Pressure Range | 0–1.25 GPa (standard test geometry) |
| Sliding/Rolling Velocity | −4 to +4 m·s⁻¹ |
| Temperature Range | Ambient to 150 °C (sub-ambient operation supported via external refrigerated oil bath) |
| Power Supply | 100–240 V AC, 50/60 Hz, 750 VA |
| Host Weight | 30 kg |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Principle | Kjeldahl Method |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | RSD ≤ 0.5% |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Distillation Time | 3–8 min/sample |
| Distillation Flow Rate | 15–30 mL/min |
| Alkali Addition Time | 0–99 s |
| Distillation Duration Setting | 0–99 min |
| Power Adjustment | 0–1500 W |
| Data Storage | 10 programmable distillation/alkalization protocols |
| Safety Features | Real-time liquid-level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Integrated ABS engineering plastic enclosure |
| Tubing | Acid- and alkali-resistant custom polymer tubing (≥3-year service life) |
| Dimensions | 370 × 300 × 680 mm |
| Net Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-200 |
| Measurement Principle | Kjeldahl Method |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | ±0.5% RSD |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Distillation Time | 3–8 min/sample |
| Distillation Flow Rate | 15–30 mL/min |
| Power Adjustment | 0–1500 W |
| Alkali Addition Time | 0–99 s (stepwise) |
| Acid Addition Time | 0–99 s |
| Distillation Duration Setting | 0–99 min |
| Data Storage | 10 programmable methods |
| Safety Features | Overpressure protection, dry-run prevention via real-time liquid level monitoring, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid/alkali resistant) |
| Tubing | Custom corrosion-resistant polymer tubing (≥3-year service life) |
| Dimensions | 370 × 300 × 680 mm |
| Net Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Cooling Water Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Principle | Kjeldahl digestion and distillation followed by colorimetric titration |
| Nitrogen Range | 0.1–240 mg N |
| Repeatability | RSD ≤ 0.5% |
| Detection Limit | 0.1–240 mg N |
| Recovery Rate | >99.5% |
| Distillation Time | 3–8 min/sample |
| Distillation Rate | 15–30 mL/min (adjustable) |
| Titration Resolution | 0.002 µL/step |
| Minimum Titration Volume | 0.8 µL/step |
| Sample Capacity | ≤6 g solid or ≤16 mL liquid |
| Alkali Addition | 1–10 segments, 0–15 s interval |
| Delay Time | 0–1800 s |
| Dimensions | 500 × 350 × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3104 / SKD-3106 |
| Configuration | 4-channel or 6-channel modular distillation system |
| Detection Range | 1–600 g SO₂ (as per sample matrix and digestion protocol) |
| Control Interface | 7-inch high-resolution capacitive touchscreen |
| Heating Method | Far-infrared ceramic radiant heating (flame-free, uniform, corrosion-resistant) |
| Temperature Range | Ambient to 450 °C |
| Distillation Time Control | 1–600 min (per channel, independently programmable) |
| Cooling System | External compact compressor-based chiller with closed-loop water circulation |
| Anti-siphon Protection | Integrated one-way valve in condensate path |
| Automation Features | Independent channel control, built-in method library, programmable magnetic stirring (per receiver), automated nitrogen flow regulation, one-touch start/stop, timer-based endpoint detection |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3106 |
| Type | Intelligent Automated Distillation System |
| Heating Method | Far-infrared Ceramic Radiant Heating |
| Temperature Range | Ambient to 450 °C |
| Time Control | 1–600 min |
| Distillation Channels | 4 or 6 independent channels |
| Cooling System | External Compact Compressor-based Closed-loop Chiller |
| Display | 7-inch HD Touchscreen LCD |
| Control Core | Microcontroller-based Embedded System |
| Anti-siphon Protection | Integrated One-way Flow Valve |
| Nitrogen Flow Control | Built-in Regulated Pneumatic Module |
| Method Storage | Preloaded & User-Editable SOPs |
| Automation Level | Fully Unattended Operation (Heating, Cooling, Stirring, Distillation, N₂ Triggering, Endpoint Termination) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-380 |
| Detection Range | 0–50 mg SO₂ |
| Detection Limit | ≤100 g solid or ≤100 mL liquid (sample-dependent) |
| SO₂ Recovery Rate | >99.5% |
| Repeatability (RSD) | ≤0.5% |
| Distillation Time | Programmable, 0–99 min per sample |
| Distillation Speed | 3–8 min/sample |
| Heating Power | Adjustable, 750–1500 W |
| Sample Processing Mode | Automatic & Manual dual mode |
| Memory Capacity | 100 programmable methods (acid volume, absorbent volume, distillation time) |
| Safety Features | Real-time liquid-level monitoring (acid, absorbent, condensate), dry-run protection for digestion cup (Peiou patented), automatic alarm & state-resume function |
| Optional | N₂ purge interface (specify at order) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-800 |
| Price Range | USD 1,400 – 7,200 (FOB) |
| Instrument Type | Protein Nitrogen Determinator |
| Measurement Principle | Classical Kjeldahl Method |
| Nitrogen Recovery Rate | >99.5% |
| Repeatability (RSD) | <0.5% |
| Detection Range | 0.08–240 mg N |
| Sample Capacity | ≤6 g solid or ≤16 mL liquid |
| Distillation Time | 1–99 min |
| Adjustable Distillation Power | 1500 W |
| Distillation Flow Rate | 15–30 mL/min |
| Data Storage | 100 pre-programmed methods + >1,000 sample records |
| Cooling Water Requirement | ≥1.5 L/min at ≤20 °C |
| Operating Pressure | ≥0.15 MPa |
| Dimensions (W×D×H) | 370 × 300 × 680 mm |
| Enclosure Material | Molded ABS engineering plastic |
| Brand | EUROTECH |
|---|---|
| Origin | Germany |
| Model | Pelletizing-20D |
| Screw Diameter | 20 mm |
| L/D Ratio | 25:1 |
| Max. Screw Speed | 150 rpm |
| Heating Zones | 4 (independent microprocessor-controlled) |
| Temperature Range | Ambient to 350 °C per zone |
| Strand Cooling | Water bath + forced-air cooling |
| Die Options | 3 mm and 4 mm round orifices |
| Feed Hopper | Equipped with material-level sensor and empty-feed alarm |
| Torque Monitoring | Real-time display with overload shutdown |
| Control Interface | TFT touchscreen panel with dedicated soft-keys for each heating zone |
| Screw Configuration | Three-zone design with dedicated mixing section (mixing length ratio: 4:1) |
| Safety Features | High/low temperature alarm, torque limit lockout, emergency stop |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-25 |
| Application | Educational Hydraulics & Turbomachinery Laboratory Equipment |
| Enclosure | Cast Housing with Transparent Observation Panel |
| Torque Measurement | Spring-Balanced Mechanical Dynamometer |
| Pressure Indication | Remote Bourdon-Tube or Digital Pressure Gauge |
| Speed Measurement | Optional Non-Contact Tachometer (100–2000 rpm range) |
| Load Control | Calibrated Weights for Pelton Injector Needle Actuation |
| Software Option | Armfield Educational Software Suite (Data Logging, Real-Time Plotting, Efficiency Calculation) |
| Brand | Harold |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | LI-II |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600-SA |
| Pricing | Available Upon Request |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC7980 |
| Pricing | Upon Request |
| Column Oven | 8-Step Programmable Temperature Ramp |
| Temperature Control Zones | 6 Independent Zones (Including Oven, Injector, Detector(s), etc.) |
| Control Functions | Memory Storage, Self-Diagnosis, Time-Based Event Programming |
| Detector Options | TCD (Thermal Conductivity Detector) with Automatic Carrier-Gas Failure Protection |
| TCD Max Operating Temp | 400 °C |
| TCD Absolute Temp Accuracy | ±0.5% of Setpoint |
| TCD Sensitivity (S) | ≥2500 mV·mL/mg (n-Hexadecane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV / 15 min |
| TCD Dynamic Range | ≥10⁶ |
| FID (Flame Ionization Detector) | Auto-Ignition via Host or Workstation Control |
| FID Max Operating Temp | 400 °C |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-Hexadecane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Baseline Drift | ≤5×10⁻¹³ A (30 min, after 150 min warm-up) |
| Software | Fully Remote-Controlled Chromatography Data System (CDS) |
| Injector Options | Packed-Column Injector |
| Optional Accessories | Modular Nickel Methanizer |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom V1 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GAP TW |
| Price | Upon Request |
| Detection Gases | O₂ (0–30.0 %vol), Combustible Gas (CH₄, 0–100 %LEL) |
| Detection Principles | Electrochemical (O₂), Catalytic Bead (Combustible) |
| Sampling Method | Natural Diffusion |
| Measurement Accuracy | ±3% FS (O₂), ±5% FS (Combustible) |
| Display Resolution | 0.1 %vol (O₂), 1 %LEL (Combustible) |
| Alarm Thresholds (Configurable) | O₂ Low: 19.5 %vol, O₂ High: 23.5 %vol |
| Combustible | 25 %LEL |
| Response Time | ≤60 s (both gases) |
| Alarms | Visual (LED), Audible (≥75 dB @ 30 cm), Vibration, Voice Prompt |
| Power | ICR18500 Li-ion Battery, 3.7 V / 2000 mAh |
| Operating Time | ≥10 h (continuous) |
| Operating Temperature | −10 to +55 °C |
| Operating Humidity | 0–95 %RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | PR-GDS-100 |
| Pricing | Upon Request |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | PaddyCheck™ PC 6800 |
| Compliance | AACCI Method No. 61-10.01 |
| Power | Rechargeable battery (3 h analysis / 8 h standby) |
| Dimensions | Compact, portable design |
| Sensor Suite | Polarized light sensor, visible-light RGB sensor, precision force sensor (17 N max load) |
| Brand | Perkone |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PF-E |
| Price Range | USD 7,000 – 14,000 |
| Mixing Bowl Capacity | 300 g |
| Torque Range | 0–1000 FU |
| Torque Accuracy | ≤0.5% of full scale |
| Torque Measurement | Electronic transducer |
| Main Mixer Blade Speed | 63 rpm |
| Auxiliary Mixer Blade Speed | 94.5 rpm |
| Mixing Bowl & Blades | German-sourced hardened stainless steel (corrosion- and wear-resistant, >10-year service life) |
| Dropper Tip Material | PTFE |
| Interchangeable Mixing Heads | Yes |
| Includes | Farinograph主机, thermal printer, water supply unit, thermostatic water bath (±0.2°C stability), dual calibrated burettes, proprietary farinogram analysis software |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Persee GMP Data Integrity Compliance Solution |
| Pricing | Available Upon Request |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | doughLAB |
| Price Range | USD 68,000 – 109,000 |
| Torque Measurement Range | 0–25 N·m |
| Rotational Speed Range | 0 or 10–200 rpm |
| Temperature Control Range | 10–80 °C (standard), with ±0.2 °C stability at 30 °C |
| Water Dispensing Range | 1–300 mL |
| Sample Bowl Options | 50 g or 300 g |
| Dimensions (H×W×D) | 970 × 490 × 370 mm |
| Weight | 91 kg (with bowl), 70 kg (without bowl) |
| Ambient Operating Conditions | 5–40 °C, <80% RH at 31 °C |
| Data Interface | RS-232 to USB converter |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | FN1000 |
| Compliance | ASTM/ICC/AACC/ISO/GB Standards |
| Sample Type | Wheat, Durum, Rye, Barley, Flour, and Other Cereal Grains |
| Measurement Principle | Viscosity-based enzymatic hydrolysis kinetics (Hagberg-Perten method) |
| Temperature Control | Precise 100 °C water bath with auto-leveling system |
| Dispensing Accuracy | 25.0 ± 0.2 mL deionized water per test |
| Display | 5.7″ color touchscreen with multilingual UI (including Chinese) |
| Connectivity | USB 2.0 + Ethernet (RJ45) for LIMS integration, barcode readers, and thermal printers |
| Altitude Compensation | Automatic correction above 610 m (2000 ft) ASL |
| Dual-Mode Operation | Standard Falling Number (FN) and Fungal Falling Number (FFN) via firmware switch |
| Data Management | Sample ID registration, moisture-corrected reporting, audit-ready result logs |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | GM2000 |
| Gluten Washing Time | 5 min |
| Mixer Speed | 120 ± 5 rpm |
| Dough Mixing Time | 20 s |
| Compliance | AACC 38-12.02, ICC 155/158/137/1, ISO 21415-2 & -4, GB/T 5506.2 & 5506.4, IRAM 15864, CCAT Method 13 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LactoScope 300™ FT-IR |
| Detection Scope | Raw milk (cow, goat, sheep, camel), cream, whey, pasteurized milk, formulated milk, dairy beverages |
| Automation Level | Semi-automatic |
| Throughput | 60–80 samples/hour |
| Repeatability | ≤1.2% CV |
| Accuracy | ≤0.5% CV |
| Operating System | Windows 10 |
| Software Interface | Fully localized Chinese GUI with stepwise workflow navigation |
| Calibration Modules | Pre-configured, ready-to-use calibration packs for raw milk, cream, whey, pasteurized milk, goat milk, sheep milk |
| Data Storage | SQL-based database architecture with backup/restore capability and external storage support |
| Protein Range | 0–15% w/w |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FT-IR) with patented Dynascan™ interferometer |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-A |
| Automation Level | Semi-automatic |
| Analysis Speed | 100–120 samples/hour |
| Measurement Range | Fat: 0–55% |
| Protein | 0–25% (including 0–15% for protein-specific quantification) |
| Lactose | 0–22% |
| Total Solids | 0–60% |
| Repeatability | ≤ 0.25% CV |
| Accuracy | < 1% CV |
| Operating System | Windows-based |
| Interface Language | English (localized UI available) |
| Calibration Kits | Pre-validated, ready-to-use modules for raw milk, cream, whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup, restore, and external storage support |
| Optical Technology | Mid-infrared (MIR) Fourier Transform Infrared Spectroscopy |
| Measurement Time | 30–45 seconds per sample |
| Interferometer | Patented Dynascan™ technology |
| Environmental Protection | OpticsGuard™ desiccation system with molecular sieve |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-B |
| Automation Level | Semi-Automatic |
| Analysis Speed | 60–80 samples/hour |
| Detection Range | Fat: 0–40% |
| Protein | 0–15% |
| Lactose | 0–15% |
| Total Solids | 0–45% |
| Repeatability | ≤0.25% CV |
| Accuracy | <1% CV |
| Operating System | Windows-based GUI with localized Chinese interface |
| Calibration Kits | Pre-validated modules for raw milk, cream (up to 40% fat), whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup/recovery support and external storage compatibility |
| Optical System | Dynascan™ interferometer-based FTIR with OpticsGuard™ desiccation and molecular sieve protection |
| Compliance | ISO 9622 / IDF 141, AOAC 972.16, ICAR-certified |
| Sample Volume | 10 mL |
| Sample Temperature Range | 4–42 °C |
| Dimensions (W×D×H) | 49 × 70 × 49 cm |
| Weight | 86 kg |
| Power Supply | 100–120 V, 60 Hz or 220–240 V, 50 Hz |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4500 |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Measurement Time | 3 min (stirring value) |
| Sample Mass | 2–3 g |
| Compliance | GB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997) |
| Software | Thermocline for Windows (TCW3) |
| Drive System | Brushless DC motor |
| Temperature Control | Programmable ramping and holding (4–130 °C) |
| Shear Control | Variable rotational speed (up to 160 rpm) |
| Data Output | Time-temperature-viscosity profiles with automated parameter extraction (onset, peak, breakdown, setback, final viscosity) |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4800 |
| Temperature Range | Up to 140 °C |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Sample Mass | 2–3 g |
| Test Duration | 3 min (stirring value), 13 min (standard starch gelatinization) |
| Compliance | GB/T 22427.7–2023, GB/T 24852–2010, GB/T 24853–2010, AACC 61-02, AACC 22-08, AACC 76-21 |
| Software | TCW3 with 67 pre-validated methods |