Industry-specific Instruments
Filter
Showing 4981–5010 of 6218 results
| Brand | Sylab |
|---|---|
| Origin | France |
| Model | IF2000G |
| Maximum Furnace Temperature | 1650 °C |
| Operating Temperature Range | 200–1550 °C |
| Heating Rate | 4–12 °C/min (programmable) |
| Temperature Accuracy | ±5 °C at 1064 °C (verified with 99.98% pure gold wire) |
| Image Resolution | 1280 × 1024 pixels |
| Frame Rate | up to 30 fps |
| Gas Flow Control | N₂, air, O₂/CO₂ (oxidizing), CO/CO₂ (reducing) |
| Sample Capacity | 4 × ASTM/ISO/AFNOR/EDF pyramidal samples (6×6×19 mm) OR 4 × DIN/CEN/Chinese cylindrical samples (3×3 mm) OR 2 × custom molds |
| Safety | Integrated CO sensor with audible alarm and automatic gas shutoff |
| Exhaust | 160 CFM, 4-inch (10.2 cm) duct interface |
| Power Supply | 215–253 V~, 50/60 Hz, single-phase, 30 A |
| Dimensions (W×D×H) | 60 × 80 × 40 cm |
| Net Weight | 70 kg |
| Compliance | ASTM D1857, ISO 540, CEN/TS 15104, AFNOR NF M 03-016, BS EN 606, AS 1038.12 |
| Brand | Sylab |
|---|---|
| Origin | France |
| Model | TGA3000 |
| Sample Capacity | 19 positions |
| Max Sample Weight | 5 g (customizable) |
| Balance Resolution | 0.1 mg |
| Temperature Programmability | Ramp rate, start/end temperature, gas flow control, lid actuation sequence |
| Software Platform | Windows-based proprietary control and analysis suite |
| Compliance | Designed for ASTM D3172, ASTM D3174, ASTM D3175, ISO 1171, ISO 562, ISO 589 |
| Brand | SYNTEC |
|---|---|
| Origin | Ireland |
| Model | TrichinEasy |
| Power Supply | 85–250 VAC ±10%, 60/65 Hz |
| Operating Temperature | +10°C to +40°C |
| Max. Relative Humidity | 85% |
| Sample Capacity | 100 g per run |
| Dimensions | 55 × 35 × 45 cm |
| Weight | 22.5 kg |
| Digestion Time | ≤30 min |
| Washing Cycle | ≤10 min |
| Fluorescent Staining Compatibility | Yes |
| Included Kit | Plytricons™ (30 assays, 100 g/sample) |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SysNova SF1000 |
| Pricing | Available Upon Request |
| Temperature Range | Up to 1000 °C |
| Current Accuracy | ±0.03% F.S. |
| Voltage Accuracy | ±0.02% F.S. |
| Fuel Compatibility | H₂, CO, CO₂, NH₃, reformate gas mixtures |
| Cell/Stack Compatibility | Button, planar, and tubular SOFC configurations |
| Safety Features | Integrated H₂ leak detection, dual-stage thermal monitoring, emergency shutdown logic |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7101 |
| Pricing | Available Upon Request |
| Measurement Range | 0.002–70 g/(m²·d) (unmasked) |
| Temperature Control Range | 10–40 °C (50–104 °F) |
| Relative Humidity Control Range | 20–90 % RH |
| Sample Area | 50 cm² (adapters available for smaller specimens) |
| Sensor Technology | High-sensitivity Coulometric P₂O₅ sensor |
| Compliance | ASTM F3299–18 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8101e |
| Test Gas | O₂ |
| RH Control Range | 0–90% ±2% |
| Temperature Control Range | 10–40°C ±0.1°C |
| Sensor Type | eMetric™ Coulometric Sensor |
| Sample Types | Flexible Films & Rigid Packaging |
| Maximum Configurable Stations | 32 |
| Operating System | Windows®-based Platform |
| Sealing Method | Q-Seal™ Chamberless Seal |
| Compliance | ASTM F2622, ASTM D3985, ISO 15105-2, ISO 1186 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | Lyssy L80-6000 |
| WVTR Range | 0.03 – 10,000 g/m²/day (standard) |
| Test Temperature Range | 5 – 50°C |
| Relative Humidity Control Range | 5 – 60% RH |
| Ambient Humidity Tolerance | 10 – 90% RH (non-condensing) |
| Dimensions | 400 × 400 × 350 mm |
| Weight | 24 kg |
| Software | Permetrace™ |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | DIT-ASTM D1709 |
| Test Methods | ASTM D1709 (Method A & B), GB/T 9639, JIS K7124 |
| Mass Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Resolution | 0.1 g (0.1 J) |
| Sample Clamping | Pneumatic, ≤1.1 MPa air supply required |
| Sample Size | >150 mm × 150 mm |
| Dimensions (A/B) | 450×450×1365 mm / 450×450×2160 mm |
| Power | AC 220 V, 50 Hz |
| Weight | 70 kg |
| Interface | Standard RS232/USB |
| Data Analysis | Built-in min/max/mean/SD calculation |
| Optional | Ball Impact Module, DSM Lab Data Management System, Safety Guard Kit |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GB 8809-1988 Pendulum Impact Tester |
| Impact Energy Options | 1 J, 2 J, 3 J, 5 J (selectable) |
| Resolution | 0.001 J |
| Impact Head Diameter | Ø25.4 mm, Ø19 mm, Ø12.7 mm |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Pressure Range | 0.3–1.5 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 492 × 383 × 752 mm |
| Net Weight | 44 kg |
| Compliance | GB/T 8809–1988, ASTM D3420, NF T54-116 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTR-7004 |
| Price Range | USD 14,000–21,500 |
| Test Range | 15–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Sample Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Sample Thickness | ≤5 mm |
| Test Gas | Clean compressed air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions | 320 × 380 × 410 mm (L×D×H) |
| Power | AC 220 V, 50 Hz |
| Net Weight | 25 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL |
| Resolution | 0.1 s/100 mL |
| Sample Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Max Sample Thickness | ≤5 mm |
| Gas Supply | Clean compressed air (0.3–1.0 MPa) |
| Interface | Ø6 mm pneumatic fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions | 370 × 320 × 220 mm (L×D×H) |
| Weight | 20 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Specimen Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Specimen Thickness | ≤5 mm |
| Test Gas | Clean Compressed Air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions (L×D×H) | 370 × 320 × 220 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 20 kg |
| Standards Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTESTER GTR-1 |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Vacuum Pressure-Difference Method |
| Test Chamber | Single-cell |
| Temperature Control | Circulating medium thermostatic control (5 °C to 95 °C, optional) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Permeation Range | 0.01–170,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Thickness Limit | ≤3 mm |
| Effective Test Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source, 0.3–1.0 MPa) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance Standards | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Software Features | Audit trail, system logging, 5-level user permission management, DSM LIMS integration (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jinan SYSTESTER Heat Sealing Tester |
| Price Range | USD 4,200 – 7,000 |
| Touchscreen Interface | Industrial TFT LCD |
| UI Design | Zero-navigation-depth flat interface |
| Temperature Control | Dual independent sealing bars |
| Max Operating Temperature | 300 °C |
| Temp Range | RT + 6 °C to 300 °C |
| Temp Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–1.1 MPa |
| Sealing Area | 265 mm × 12 mm (customizable) |
| Sealing Mode | Dual-bar independent control |
| Pneumatic Interface | Ø6 mm |
| Air Supply Requirement | 0.05–1.1 MPa (user-supplied) |
| Dimensions (L×W×H) | 410 × 396 × 416 mm |
| Weight | 33 kg |
| Power | AC 220 V, 50 Hz |
| Safety Features | Emergency stop button, anti-scald housing, fanless design |
| Noise Level | <35 dB(A) |
| Standard Compliance | QB/T 2358 (equivalent to ZBY 28004), ASTM F2029, YBB00212005-2015 |
| Data Output | Integrated thermal printer |
| Communication Interface | Standard RS232/USB |
| Optional Integration | DSM Laboratory Data Management System (sold separately) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | Membrane Separation Performance Evaluation System |
| Test Range | 0.01–2×10⁴ Barrer |
| Gas Flow Rate | 0–100 mL/min (200/300 mL/min optional) |
| Measurement Accuracy | ±0.01 Barrer |
| Vacuum Accuracy | ±0.1 Pa |
| Test Pressure Differential | 0–10 bar (system rated to 16 bar) |
| Temperature Control Range | 5–95 °C (±0.1 °C with optional chiller/heater) |
| Effective Test Area | Φ20 mm (3.14 cm²) |
| Sample Thickness Limit | ≤2 mm |
| Sample Capacity | 1 specimen per run |
| Detector Sensitivity | ≥5000 or 10000 mV·mL/mg (configurable) |
| Baseline Drift | ≤0.10 mV |
| Noise | ≤0.015 mV |
| Carrier Gas Pressure | 2 bar |
| Compatible Carrier Gases | N₂, H₂, He, Ar |
| Dimensions (Host) | 320 × 625 × 335 mm (W×D×H) |
| (GC Unit) | 590 × 480 × 500 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QBT 2411 |
| Price Range | USD 18,000 – 24,500 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.001–220 µg/(m²·s) |
| Permeability Range | 1×10⁻³–40,000 ng/(m²·s·Pa) |
| Sample Capacity | 6 independent stations |
| Weight Resolution | 0.0001 g |
| WVTR Resolution | 0.00001 µg/(m²·s) |
| Temperature Range | 15–55 °C (±0.1 °C control accuracy) |
| Humidity Range | 10–95 %RH (±1 %RH control accuracy |
| Air Sweep Velocity | 0.5–2.5 m/s |
| Specimen Thickness Limit | ≤25 mm |
| Test Area | 33.17 cm² |
| Specimen Diameter | Φ81 mm |
| Chamber Volume | 36 L |
| Air Supply | Compressed air, 0.2–1.0 MPa, Φ8 quick-connect fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 550 × 475 mm |
| Net Weight | 67 kg |
| Compliance | GB/T 1037, QB/T 2411–1998 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |
| Brand | μfactory |
|---|---|
| Origin | France |
| Model | T-Skin |
| Application | In vitro skin barrier function assessment |
| Regulatory Context | Designed for GLP-compliant cosmetic ingredient screening and formulation development |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FP-2260 |
| Price Range | USD 14,000 – 70,000 |
| Standards Compliance | ASTM D1894, D4521, D3330, F88 |
| Load Cell Options | 0.5 kg, 1 kg, 2 kg, 10 kg |
| Resolution | 0.1 g |
| Accuracy | ±0.25% of full scale |
| Force Units | g, kg, oz, lb, N |
| Test Speed | Standard: 1–20 in/min |
| High-Speed | 10–110 in/min |
| Standard Sled Masses | 200 g, 500 g, 1000 g, 3 lb |
| Test Duration | 0.1–99 s |
| Travel Distance | 0.1–14.0 in |
| Display | 240 × 64 pixel LCD |
| Data Storage | 127 test records |
| Test Area | 225 mm × 350 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 27 in × 12 in × 7 in |
| Weight | 20 kg |
| Brand | T&R |
|---|---|
| Origin | United Kingdom |
| Model | 750ADM MK4 |
| Output Capacity | 750 A (primary), 40 A / 16 V (secondary) |
| Open-Circuit Voltage | 5.0 V (230 V supply) |
| Continuous Current Rating | 125 A |
| Short-Term Current Rating | 750 A for 20 s (230 V) |
| True RMS Measurement Accuracy | ±0.5% rdg + 2–5 digits |
| Timing Resolution | 1 ms |
| Timing Accuracy | ±0.01% rdg + 2d (conventional mode) |
| Storage | USB-based CSV logging with real-time clock timestamping |
| Safety Compliance | BS EN 61010-1, UKCA certified |
| Dimensions (metal enclosure) | 560 × 456 × 265 mm |
| Weight | 27.4 kg |
| Power Input | Auto-ranging 115 V / 230 V ±10%, 50/60 Hz, single-phase |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MDR one |
| Compliance | ASTM D5289, ISO 6502, DIN 53529-1 |
| Temperature Control Range | Ambient to 200 °C (standard), optional refrigeration unit for sub-ambient testing |
| Torque Measurement Range | 0.001–10 N·m |
| Angular Displacement Resolution | ≤ 0.001° |
| Drive System | Direct-drive servo motor |
| Frame Stiffness | > 10⁶ N/m |
| Sample Geometry | Sealed dual-cone die (standard), interchangeable with oscillating disk or rotorless rectangular dies |
| Automation | Optional robotic sample handler with pneumatic die clamping |
| Software | Scarabaeus v5.x (multi-language UI, 21 CFR Part 11-compliant audit trail, raw data export in ASTM E1382-compliant format) |
| Calibration | User-performed torque and temperature calibration with NIST-traceable reference standards |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MV one |
| Motor Speed Range | 0.1–10 rpm (standard test at 2 rpm) |
| Rotor Options | 38.10 mm (large) and 30.48 mm (small) diameter |
| Compliance | ASTM D1646, ISO 289, DIN 53523 |
| Temperature Control | High-precision, PID-regulated, ±0.1 °C stability |
| Torque Measurement | Auto-calibrating, high-resolution digital torque sensor |
| Frame | Ultra-rigid monolithic steel construction |
| Drive System | Direct-drive brushless motor with <0.01 rpm speed resolution |
| Software | Scarabaeus v5.x (multi-language, GLP-compliant audit trail, FDA 21 CFR Part 11 ready) |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 150-E |
| Measurement Range | 0–10,000 Taber Stiffness Units (g·cm) |
| Compliance | CE Marked |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Display | 4×20 Vacuum Fluorescent Display |
| Data Storage | 1,000 readings with timestamp & user-defined labels |
| Interface | RS-232 serial port, parallel printer port |
| Test parameters programmable | deflection angle, direction, cycle count |
| Accuracy | ±1% full scale (factory calibrated) |
| Sample thickness range | 0.1–5.5 mm |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 150-E |
| Sample Thickness Range | 0.1–5.5 mm |
| Applicable Materials | Paper, Foil, Thin Metal Sheets, Plastic Films, Cardboard, Rubber, Melamine Board, Vinyl, Wires, Tubing, Textiles, Felt, Leather |
| Drive Mechanism | Constant-Speed Motor with Gear-Driven Rotating Disc |
| Measurement Principle | Pendulum Deflection Under Controlled Torsional Load |
| Output | Analog Dial or Digital Display (Configurable) |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | Taber 1750 |
| Compliance | ASTM D3884, ASTM D4060, ISO 9352, ISO 5470-1, JIS K7204, TAPPI T476, DIN 52347, EN 13329 |
| Operating Environment | 21–24°C (70–75°F), 50% RH |
| Sample Mounting | Flat, rigid specimens secured on rotating turntable |
| Abrasion Mechanism | Dual counter-rotating abrasive wheels applying controlled load in crossed-arc motion |
| Vacuum-Assisted Debris Removal | Adjustable suction for real-time particulate extraction |
| Control Interface | Digital display with programmable cycle count, vacuum activation, and power-on resume memory |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 5135 |
| Power Supply | 115 V, 50/60 Hz AC |
| Compliance | ASTM D3884, ASTM D4060, ISO 9352, ISO 5470-1, JIS K7204, TAPPI T476 |
| Sample Area | 30 cm² |
| Load Range | Adjustable in grams (g) |
| Rotation Count | Electronically measured |
| Vacuum Dust Extraction | Integrated |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | Taber 551 |
| Sample Thickness Capacity | 0.5" to 4" (12.7 mm to 101.6 mm) |
| Adjustable Normal Load Range | 0–1000 g |
| Standard Compliant | ASTM D7027, ISO 4586-2, EN 438-2, JIS K6902, DIN 53799, AS/NZS 2924.2, CEN/TS 14688, UNI 9428, Federal Specifications L-F-00450A, L-T-00345, L-T-751, SS-T-307, SS-T-312 |
| Brand | SDL Atlas |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | M270 |
| Pricing | Available Upon Request |
| Brand | Taber Instruments (USA) |
|---|---|
| Origin | USA |
| Model | Grit Feeder-255 |
| Abrasive Capacity | 4500 g |
| Mounting Flexibility | Left- or Right-Side Installation |
| Adjustable Nozzle Height | Up to +40 mm via Cantilever Extension Kit |
| Compatible Testers | Taber Rotary Wear Testers (Model 5135, 5155) |
| Standard Abrasive | Taber S-41 #240 Aluminum Oxide |
| Calibration Reference | Taber S-38 Standard Calibration Plate |
| Compliance | EN 14354, ISO 24338 Method B (with Alodur ESK 240) |
| Dust Extraction Interface | Integrated vacuum port for synchronization with tester’s vacuum system |