| Brand | Timepower |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP582 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Beijing Shidai Xinwei Measurement & Control Equipment Co., Ltd.) |
| Compliance | GB/T 5096, GB/T 7327, SH/T 0232, SH/T 0023, ASTM D130 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Timing Range | 1 min to 24 h |
| Sample Capacity | 4–12 copper strips per test cycle |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤1800 W |
| Operating Environment | 10–35 °C, RH ≤85% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Quotation | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | 4 test cells (up to 12 samples per run) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 mm × 360 mm × 520 mm |
| Net Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Price | Upon Request |
| Power Supply | 220 V ±10%, 50 Hz |
| Temperature Sensor | Pt100 |
| Temperature Control Range | Ambient to 100 °C (adjustable) |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | Main heater 600 W + Auxiliary heater 1000 W |
| Timing Range | 1 min to 24 h (adjustable) |
| Sample Capacity | 4 sample wells (supports 4–12 test specimens per run) |
| Display | LED digital display for temperature and time |
| Ambient Operating Conditions | ≤35 °C, RH ≤85% |
| Overall Power Consumption | ≤1800 W |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Quotation | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | Up to 12 copper strips (4 test wells per bath, configurable multi-bath operation) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 × 360 × 520 mm |
| Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | TimePower |
|---|---|
| Model | TP582 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 5096, GB/T 7327, SH/T 0232, SH/T 0023, ASTM D130 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensor | Pt100 |
| Heating Power | Main 600 W + Auxiliary 1000 W |
| Timing Range | 1 min to 24 h |
| Sample Capacity | 4 sample wells (expandable to 12 test positions) |
| Display | LED digital display for temperature and time |
| Power Supply | 220 V ±10%, 50 Hz |
| Ambient Operating Conditions | ≤35 °C, RH ≤85% |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Total Power Consumption | ≤1800 W |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP586 |
| Pricing | Upon Request |
| Temperature Sensor | Pt100 (JUMO Germany OEM) |
| Bath Temperature Range | 0–400 °C |
| Standardized恒温 Points & Accuracy | 150 ±1.0 °C, 180 ±1.0 °C, 250 ±1.0 °C |
| Programmable Setpoint | Yes |
| Temperature Control Accuracy | ±1 °C |
| Oil Bath Dimensions | Φ200 × 220 mm |
| Power Consumption | <2500 W |
| Rated Current | 10 A |
| Test Port Count | 3 |
| Thermometer Range | –5 to 400 °C, Graduation: 1.0 °C |
| Air Flowmeter Range | 40–70 L/min |
| Ambient Operating Conditions | 10–40 °C, RH 30–80% |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Net Weight | 45 kg |
| Overall Dimensions | 400 × 350 × 450 mm |
| Compliance Standards | GB/T 509, GB/T 8019 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 261, ASTM D93 |
| Repeatability | ≤4 °C |
| Ignition Methods | Fully automatic electronic arc, gas flame, electric spark, pilot flame, and manual ignition modes |
| Temperature Range | −25 °C to 400 °C |
| Measurement Range | 40 °C to 370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Display | 260K-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English support) |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Range | 5–40 °C, RH ≤85% |
| Atmospheric Pressure Compensation | Yes |
| Ignition Options | Switchable gas flame scanning or electronic spark ignition |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automated test arm retraction |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated Forced-Air Cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Ignition Options | Gas flame scanning or electronic spark ignition (user-selectable) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261 compliant) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Safety Features | Over-temperature cutoff, self-diagnostic system, atmospheric pressure compensation, flame detection lockout |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity | ≤85% |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character width, Chinese character support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English output) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Ignition Modes | Switchable gas flame scanning or electronic spark ignition |
| Safety Features | Over-temperature cutoff, self-diagnostic system, ventilation cabinet operation requirement |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Compliance Standards | GB/T 261, ASTM D93 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (Pensky-Martens / Tag Closed Cup) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 261, GB/T 3536, ASTM D92, ASTM D93 |
| Repeatability | ≤4 °C |
| Ignition Methods | Fully automatic electronic arc ignition, manual gas flame ignition, electric spark ignition, pilot gas flame ignition, and user-selectable scanning modes |
| Temperature Range | Ambient to 400 °C (standard configuration) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Standards Compliance | GB/T 261, ASTM D93 |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C (for flash point < 110 °C) |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480 × 272) |
| Cooling Method | Integrated Forced-Air Cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85 % |
| Safety Features | Overtemperature cutoff, self-diagnostic system, atmospheric pressure compensation, flame-scan mode selection (gas or electronic ignition) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP611 (Open-Cup) / TP612 (Closed-Cup) |
| Detection Method | Cleveland Open-Cup (ASTM D92) and Pensky-Martens Closed-Cup (ASTM D93, GB/T 261) |
| Operation Mode | Fully Automatic |
| Temperature Range | 40–370 °C |
| Ignition Method | Motorized Electronic Igniter with Precise Positioning |
| Repeatability | ≤2 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Display | 5.0-inch capacitive touchscreen, Chinese UI |
| Cooling Method | Integrated High-Flow Air Cooling System |
| Printer | Thermal printer, 36-character line, Chinese character support |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions (W×D×H) | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Included Accessories | Standard test cup (ASTM E1–compliant), motorized ignition arm, LPG gas regulator assembly (for butane/propane), calibration certificate |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (stainless steel sheath) |
| Ignition Modes | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Cooling Method | Integrated forced-air cooling |
| Display | 480×272 TFT color LCD (260K colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Type | Domestic |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Imported Pt100 (stainless steel sheath) |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction |
| Cooling Method | Integrated high-efficiency air cooling |
| Display | 480×272 TFT color LCD (260K colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Operating Environment | 5–40 °C, RH ≤85% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (stainless steel sheath) |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction |
| Cooling Method | Integrated forced-air cooling |
| Display | 5.0-inch capacitive touch LCD (Chinese UI) |
| Printer | Thermal printer, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower (OEM/ODM Capable) |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (ASTM D92 / GB/T 3536) |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (Imported, Stainless Steel Housing) |
| Display | 5.0-inch Touchscreen LCD (Chinese UI) |
| Cooling | Integrated High-Flow Air Cooling System |
| Printer | Thermal, 36-character Chinese/English Output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Environmental Operating Range | 5–40 °C, RH ≤85% |
| Safety Features | Overtemperature Auto-Shutoff, Atmospheric Pressure Compensation, Self-Diagnostic Fault Detection |
| Ignition Options | Switchable Gas Flame (LPG Propane/Natural Gas) or Electronic Spark Scanning Mode |
| Compliance | ASTM D92, GB/T 3536, ISO 2592 (Referenced), IEC 61000-4 EMC Immunity |
| Brand | Timepower |
|---|---|
| Model | TP 612 |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Temperature Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Heating Control | Adjustable ramp rate |
| Ignition Modes | Switchable gas flame or electronic arc scanning |
| Detection System | High-precision ionization ring sensor |
| Atmospheric Pressure Compensation | Built-in correction algorithm |
| Safety Features | Over-temperature cutoff, self-diagnostic error reporting |
| Cooling Method | Integrated high-flow air cooling |
| Display | 480×272 TFT color LCD (262k colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Brand | Timepower |
|---|---|
| Model | TP612 |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (stainless-steel sheathed) |
| Display | 5.0-inch touch LCD (Chinese interface) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English output) |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction, flame detection via ionization ring |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP612 Cleveland Open-Cup Flash Point Tester |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 3536, ASTM D92 |
| Repeatability | ≤4 °C |
| Ignition Mode | Fully Automatic |
| Temperature Range | 79–370 °C |
| Accuracy | ±2 °C |
| Resolution | 0.1 °C |
| Cooling Method | Integrated Forced-Air Cooling |
| Display | TFT Color LCD (480×272, 260K colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Brand | Timepower |
|---|---|
| Model | TP612 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Detection Method | Cleveland Open Cup (COC) |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 5.0-inch touch LCD (Chinese interface) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English output) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Temperature Sensor | Imported Pt100 (stainless steel sheath) |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction, flame detection via high-precision ionization ring |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP612 |
| Detection Method | Cleveland Open Cup (COC) |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Heating Rate | Adjustable |
| Ignition Modes | Gas Flame Scanning or Electronic Spark Ignition (user-selectable) |
| Temperature Sensor | Imported Pt100 RTD, Stainless Steel Housing |
| Display | TFT Color LCD (480 × 272, 260K colors) |
| Cooling | Integrated High-Flow Air Cooling System |
| Printer | Thermal Printer (36-character width, Chinese/English support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Overtemperature Auto-Shutoff, Self-Diagnostic Fault Detection, Automatic Test Arm Retraction, Ventilation Cabinet Requirement |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower (Beijing Shidai Xinwei Measurement & Control Equipment Co., Ltd.) |
| Type | TP622 |
| Compliance Standards | SH/T 0811, SH/T 0206 |
| Heating Method | Precision Metal Bath (Oil-Free) |
| Temperature Control | PID-Based with ±0.1 °C Stability |
| Safety Features | Dual-Stage Over-Temperature Protection |
| Gas Flow Monitoring | Calibrated Soap-Bubble Flowmeter (±2% accuracy) |
| Timing Function | Programmable Digital Timer with Auto-Start/Stop |
| Certification Support | NIST-Traceable Calibration Certificate Available |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TP622 |
| Pricing | Available upon request |
| Temperature Control Range | Ambient to 160 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1100 W |
| Sample Capacity | 6 parallel test channels |
| Heating Method | Metal bath (oil-free) |
| Temperature Regulation | PID feedback control |
| Safety Features | Built-in over-temperature protection |
| Gas Flow Measurement | Calibrated soap-bubble flowmeter |
| Timing Function | Integrated digital timer |
| Calibration Documentation | NIST-traceable calibration certificate available |
| Brand | TimePower |
|---|---|
| Model | TP 622 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Application Standard Compliance | SH/T 0811, SH/T 0206 |
| Heating Method | Metal Bath (Oil-Free) |
| Temperature Control | Digital PID Controller with RTD Sensor |
| Temperature Range | Ambient to 160 °C |
| Temperature Stability | ±0.5 °C at Setpoint |
| Sample Capacity | 6 Parallel Reaction Vessels |
| Gas Flow Measurement | Calibrated Soap-Bubble Flowmeter |
| Timing Function | Integrated Digital Timer |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1100 W |
| Dimensions (W×D×H) | 480 mm × 350 mm × 595 mm |
| Safety Features | Dual-Stage Over-Temperature Protection, Automatic Gas Shutoff Interlock (Optional), Ventilation Monitoring Interface |
| Calibration Documentation | Optional NIST-Traceable Metrology Certificate Available |