Life Science Instruments
Filter
Showing 4141–4170 of 7577 results
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC-JSF-1T/3 |
| Vessel Volume | 10 L (per vessel) × 3 |
| Aeration System | Quadruple sterile air supply lines |
| pH Control Range | 2.0–12.0 |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Temperature Control Range | 5–65 °C (via chilled water + electric heating) |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | MC-JSF-50 |
| Vessel Volume | 0.5–500 L (Standard Config: 50 L) |
| Aeration System | Integrated Deep-Flow Sterile Air Supply |
| pH Control Range | 2.0–12.0 |
| Dissolved Oxygen (DO) Control Range | 0–100% (or 0–200%) |
| Temperature Control Range | 0–100 °C |
| Design Pressure | 0.3 MPa |
| Operating Pressure | 0.15 MPa |
| Material | SUS316L/SUS304 Stainless Steel |
| Internal Surface Finish | Ra ≤ 0.4 µm |
| External Finish | Bead-Blasted or Polished |
| Stirring Speed | 50–600 rpm (±1% accuracy, 1 rpm resolution) |
| Sterilization | In-situ Steam Sterilization (SIP), 121 °C for 30 min |
| Compliance | Meets ISO 8573-1 (compressed air purity), ASME BPE-2021 (bioprocessing equipment), and GLP/GMP design principles |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC-NFS-II |
| Reactor Volume | 1 L per vessel |
| Max. Simultaneous Reactors | 4 |
| Sample Batch Capacity | ≤100 bags |
| Measurement Resolution | 3.5 (unitless, dimensionless digestibility index) |
| Detection Range | 0–6000 (arbitrary units correlating to gas production or metabolite accumulation) |
| Temperature Control Range | Ambient to 45 °C |
| Standard Setpoint | 39.5 °C |
| Accuracy | ±0.1 °C |
| Oscillation | 3D spatial shaking |
| Filtration Pore Size | 25–30 µm |
| Sample Mass per Bag | 0.25–1.5 g |
| Digestibility Range | 0–100% |
| Reproducibility (RSD) | ≤0.2% |
| Data Logging Intervals | 1/5/10/30 min |
| Output Format | Excel (.xlsx) via USB export |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single-Well Format |
| Application Domain | In Vitro Electrophysiology |
| Electrode Configurations | 32-, 64-, 128-, and 256-channel flexible or rigid substrates |
| Substrate Options | Polyimide-based flexible arrays (thickness down to 10 µm) and glass-based rigid arrays (50 × 50 × 1 mm base |
| electrode diameters | 20/30/50 µm |
| well inner diameter | 22 mm) |
| Compatibility | Langendorff-perfused hearts, open-chest in vivo preparations, tissue slices, monolayer cardiomyocyte cultures |
| Mechanical Integration | Compatible with MappingLab multi-axis micromanipulator (universal joint mount), perfusion chambers, Faraday cages, and humidified incubator environments |
| Regulatory Context | Designed for GLP-compliant preclinical cardiac electrophysiology studies |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MVC-801 |
| Instrument Type | Semi-Automatic |
| Control Interface | Analog (0–5 V / 0–10 V) & Digital (TTL/BNC) |
| Valve Count | 8 Independent Solenoid Valves |
| Valve Specifications | 12 V DC, Max 4 W per valve, Min 24 Ω resistance |
| Cascade Capability | 11 Isolated BNC Trigger Inputs/Outputs |
| Memory Function | Yes (Last Valid Configuration Retained) |
| Overflow Protection | Integrated Flow Monitoring with Audible/Visual Alert |
| Software Compatibility | Native Integration with pCLAMP (Axon), PatchMaster (HEKA), and Custom LabVIEW/Python Scripts |
| Regulatory Context | Designed for GLP-compliant electrophysiology laboratories |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Model | SG-WH012 |
| Instrument Type | Manual |
| Temperature Control Range | Ambient to 100 °C |
| Flow Rate Range | 0.02–380 mL/min |
| Pump Speed Range | 0.1–100 rpm (bidirectional adjustable) |
| Temperature Accuracy | ±0.5 °C |
| Water Bath Dimensions | 390 × 330 × 180 mm |
| Perfusion Chamber Volume | 200 mL / 500 mL |
| Return Reservoir Volume | 100 mL / 200 mL |
| Speed Resolution | 0.1 rpm |
| Peristaltic Pump Dimensions | 232 × 142 × 149 mm |
| Operating Environment | 0–40 °C, RH < 80% |
| Ingress Protection Rating | IP31 |
| Brand | MappingLab |
|---|---|
| Model | VCS-3002 |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | ±90 V |
| Current Range | ±32 mA |
| Voltage Accuracy | ±0.1 V |
| Current Accuracy | ±20 µA |
| Max Output Frequency | 30 kHz |
| Pulse Duration Stability | Up to 200 h continuous operation |
| Isolation | Built-in galvanic isolation (no external isolator required) |
| I/O Interface | TTL-triggered stimulation, analog/digital I/O connectors |
| Protection | Integrated overcurrent and overvoltage protection |
| Brand | Marzhauser |
|---|---|
| Origin | Germany |
| Model | SCAN IM |
| Travel Range | 30 mm to 300 mm (X/Y) |
| Compatibility | Upright, Inverted & Stereo Microscopes |
| Mounting Interface | Standard dovetail and screw-hole patterns per DIN/ISO microscope stage specifications |
| Drive Type | Stepper motor with closed-loop position verification |
| Positioning Resolution | ≤ 0.1 µm (dependent on controller and microstepping configuration) |
| Repeatability | ±0.5 µm |
| Load Capacity | Up to 1.5 kg (static, centered) |
| Environmental Rating | Designed for ISO Class 5–7 laboratory environments |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | F31039-14 |
| Pricing | Available Upon Request |
| Brand | 908 Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAVERICK |
| Price Range | USD 1,500 – 150,000 (FOB) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S13047-14 |
| Pricing | Available Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Models | F31034-15, F31034-18 |
| Pricing | Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Numbers | S13031-17 (Straight), S13032-17 (Curved) |
| Pricing | Available Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & Direct Producer |
| Country of Origin | China |
| Model Numbers | S13049-14 (Straight), S13050-14 (Curved) |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MB99-1 |
| Price | USD 2,850 (FOB Shanghai) |
| Brand | MBS |
|---|---|
| Origin | Netherlands |
| Model | cyQlone™ |
| Instrument Type | Ultra-Fast Real-Time PCR System |
| Sample Throughput | 6-Channel Detection |
| Power Supply | 80–240 V, 50/60 Hz |
| Max Power | 800 W |
| Avg Power | 150 W |
| Dimensions (W×L×H) | 197 × 580 × 375 mm |
| Weight | 22 kg |
| Display | LCD |
| Detection Method | Integrated Fiber-Optic Fluorescence Detection |
| Compatible Plate Format | NextGenPCR™ Polypropylene Microplates |
| Fluorophore Channels | FAM, ROX, Cy5, ATTO425, TET, Cy7 |
| Cycle Detection Time per Channel | ≤20 ms |
| Full 96-Well Run Time | ≤9 min |
| Brand | MBS S.r.l. |
|---|---|
| Origin | Italy |
| Model | MBS (Fitlylab) |
| Instrument Type | Fully Automated Microbial Detection & Quantification System |
| Detection Throughput | 8 independent channels |
| Sample Types | Liquid, solid, surface swabs, semi-solid (e.g., pastes, gels) |
| Target Microorganisms | Total viable count, *Escherichia coli*, *Staphylococcus aureus*, *Salmonella* spp., *Pseudomonas aeruginosa*, *Listeria monocytogenes*, *Enterococcus faecalis*, coliforms, fecal coliforms, *Enterobacteriaceae*, yeasts |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | ≥99.999% |
| Detection Principle | Multi-modal optical biosensing based on real-time monitoring of redox-mediated chromogenic response in VL detection vials |
| Regulatory Compliance | ISO 16140:2003 (validation of alternative methods), ISO/IEC 17025:2017 (testing laboratory competence), ISO/TR 13843:2000 (water microbiology) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MBS (Fitlylab) |
| Detection Method | Chromogenic & Redox-Based Colorimetric Assay |
| Instrument Type | Fully Automated |
| Detection Targets | Total Bacterial Count, *Salmonella* spp., Total Coliforms, *Staphylococcus aureus*, *Escherichia coli*, *Listeria monocytogenes* |
| Sample Types | Compound Feeds (layer/broiler chicken, swine, duck), Animal-Origin Feeds (blood meal, meat-and-bone meal, fish meal, feather meal, whey powder), Plant-Origin Feeds (corn, bran, soybean meal, peanut meal, cottonseed meal) |
| Detection Throughput | 8 independent channels |
| Dimensions | 31.2 cm (L) × 17.5 cm (W) × 9.5 cm (H) |
| Regulatory Compliance | ISO 16140:2003 validated, ISO/IEC 17025:2005 aligned, T/SDAA 025–2021 certified |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Method | Chromogenic Enzyme-Substrate Assay Coupled with Redox-Based Colorimetric Monitoring |
| Target Microorganisms | Escherichia coli, Staphylococcus aureus, Salmonella spp., Pseudomonas aeruginosa, Listeria monocytogenes, Enterococcus faecalis, Total Viable Count, Coliforms, E. coli (specific), Fecal Coliforms, Enterobacteriaceae, Yeasts |
| Sample Types | Solid, Liquid, Surface Swabs, Paste, Slurry |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Throughput | 8 independent, temperature-controlled detection channels |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% |
| Compliance | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs — Validation of Alternative Methods), ISO/IEC 17025:2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L02 |
| Price Range | USD 14,000 – 70,000 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal Oxidative-Reductive Kinetic Assay with Tri-wavelength Photometric Monitoring |
| Sample Throughput | 8 Independent Channels |
| Detection Limit | 1 CFU per test |
| Specificity | ≥99.999% |
| Sample Types | Liquid, Solid, Surface Swab, Paste, Aerosol Condensate |
| Regulatory Compliance | Validated for Food, Water, Environmental & Clinical Surveillance per ISO, EN and FDA-aligned protocols |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L03 |
| Instrument Type | Benchtop |
| Detection Principle | Respirometric Colorimetric Culture-Based Assay |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Capacity | 8 Independent Channels |
| Optical Detection | Simultaneous Tri-Wavelength Photometry (450 nm, 540 nm, 630 nm) |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target Enterobacteriaceae and E. coli |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste) |
| Reporting | Automated PDF generation with timestamped audit trail, GLP-compliant data storage |
| Key | Brand: MBS.SRL |
|---|---|
| Origin | Italy |
| Type | Semi-Automatic Microbial Detection System |
| Throughput | 8 independent channels |
| Filter Cup Capacity | 11 mL |
| Filter Membrane Diameter | 47 mm |
| Detection Principle | Multi-modal (respirometric + enzymatic + immunogenic + nucleic acid–enhanced colorimetric assay) |
| Certified to ISO 16140 | 2003 (validation of alternative methods in food microbiology) and ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L22 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target analytes |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste, slurry) |
| Readout Method | Simultaneous tri-wavelength photometric monitoring (450 nm, 530 nm, 630 nm) |
| Report Output | PDF with audit trail, timestamped raw kinetic curves, and quantitative CFU/mL or CFU/g results |
| Software | Fitlylab v5.x (Windows-based, multilingual, GLP-compliant data management) |
| Brand | MBS |
|---|---|
| Origin | Netherlands |
| Model | NGPCR |
| Instrument Type | Ultra-Fast PCR Thermal Cycler |
| Sample Throughput | 96-well and 384-well plates |
| Thermal Architecture | Triple independent temperature control modules |
| Heating/Cooling Transition Time | <0.1 s between denaturation and annealing steps |
| Typical Cycle Time (100 bp amplicon) | 2 minutes for 30 cycles |
| Daily Throughput Capacity | Up to 80 × 384-well plates under optimal operational conditions |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L01 |
| Instrument Type | Fully Automated Microbial Detection & Enumeration System |
| Detection Principle | Multi-modal optical monitoring of redox-mediated chromogenic response in sealed VL detection vials |
| Throughput | 8 independent parallel detection channels |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Sensitivity | ≥1 CFU per test |
| Specificity | ≥99.999% |
| Compliance | ISO 16140:2003 (validation of alternative microbiological methods), ISO/IEC 17025:2005 (general requirements for competence of testing and calibration laboratories) |
| Sample Forms | Liquid, solid, surface swab, semi-solid (paste/gel), aerosol-derived (via impinger or filtration) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L04 |
| Price Range | USD 13,500 – 68,000 |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L06 |
| Certification | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs – Validation of Alternative Methods) |
| ISO/IEC 17025 | 2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per assay |
| Specificity | ≥99.999% for *Salmonella* spp. |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., milk, paste, homogenates) |
| Detection Time | 4–12 h (vs. 48–96 h for conventional culture) |
| Wavelengths | Simultaneous triple-wavelength photometric detection (450 nm, 540 nm, 630 nm) |
| Data Output | Automated PDF report with timestamped kinetic curves, CFU/mL or CFU/g quantification, pass/fail flagging against user-defined thresholds |
| Software | Fitlylab v3.x (Windows-based, multilingual, audit-trail enabled) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Fitlylab-L22 |
| Detection Range | Sample-dependent (validated per ISO 16140:2003) |
| Detection Time | 2–10 hours |
| Detection Throughput | 1 CFU per assay |
| Sampling Frequency | Single-point measurement per vial |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC99-3 |
| Price | USD 4,280 (FOB Shanghai) |
| UV Wavelengths | 220, 254, 280, 340 nm |
| Fraction Collection Capacity | 100 × 12 mL tubes |
| Timing Range | 1 s – 9999 min |
| Droplet Counting Range | 1–9999 drops |
| Peak Detection Range | 0–100 mV |
| Gradient Volume | 1000 mL (linear profile only) |
| Pump Flow Rate | 1–80 mL/min |
| Peristaltic Pump Speed | 0.1–100 rpm |
| Column Set | Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm |
| System Weight | 32 kg |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | RM21™ Microscope Platform |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Metal Halide Lamp |
| Eyepiece Compatibility | Standard 23.2 mm or 30 mm Mounts |
| Objective Compatibility | Standard RMS or M25 Thread Mounts |
| Fluorescence Configuration | Epi-illumination (Reflected Light) |
| Illumination Flexibility | Compatible with Broadband, LED, and Laser Sources |
| Observation Geometry | Inverted Optical Layout |
| Z-Axis Travel | 50 mm (2 in) with 95 nm Step Resolution |
| XY Positioning | Manual or Motorized Micropositioner (Optional) |
| Encoder Option | Closed-Loop Encoders Available for X, Y, and Z Axes |
| Integration Ready | Fully Compatible with Nano-Cyte® 3D Stability System, Nano-LPS/Nano-LPQ Linear Positioners, Nano-OP/Nano-F Objective Positioners, and LCC-Focus™ Autofocus Modules |