Life Science Instruments
Filter
Showing 4231–4260 of 7566 results
| Brand | MENTS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MS-100 |
| Instrument Type | Multi-Function Heated Shaker |
| Timer Range | 99 h 59 min |
| Oscillation Speed | 200–1800 rpm |
| Horizontal Amplitude | 3 mm |
| Temperature Range | Ambient +5 °C to 100 °C |
| Number of Shaking Platforms | 1 |
| Brand | MEPSGEN |
|---|---|
| Origin | South Korea |
| Model | PROMEPS |
| Weight | ~50 kg |
| Power Consumption | ~2000 W |
| Input Voltage | 100–130 VAC / 200–240 VAC, 60 Hz |
| CO₂ Supply Pressure | 1.2 bar |
| CO₂ Purity | 100% |
| Operating Temperature | 20–30 °C |
| Relative Humidity (Operating) | 30–80% RH |
| Storage Temperature | 0–60 °C |
| Storage Humidity | 30–90% RH |
| CO₂ Control Range | 1–20% |
| Media Flow Rate | 200 mL/min |
| Temperature Control Range | Ambient to 45 °C |
| Impedance Channels | 32 |
| Impedance Measurement Range | 0–100 kΩ |
| Display Resolution | 800 × 480 px |
| Touchscreen Type | Capacitive |
| Connectivity | Ethernet, USB |
| Brand | MEPSGEN |
|---|---|
| Model | ProMEPS |
| Origin | South Korea |
| Category | Imported |
| Weight | ~50 kg |
| Power Consumption | ~2000 W |
| Input Voltage | 100–130 VAC / 200–240 VAC, 60 Hz |
| CO₂ Supply | 100% CO₂ at 1.2 bar |
| Gas Flow Rate (Media) | 200 mL/min |
| Temperature Control Range | Ambient to 45 °C |
| Humidity Control Range | 30–80 % RH (Operating), 30–90 % RH (Storage) |
| Impedance Channels | 32 |
| Impedance Measurement Range | 0–100 kΩ |
| Display | 800 × 480 px capacitive touchscreen |
| Connectivity | Ethernet & USB |
| Operating Temperature | 20–30 °C |
| Storage Temperature | 0–60 °C |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CellStream |
| Product Type | Flow Cytometry Analyzer |
| Lasers | Up to 7 (configurable) |
| Detection Channels | 22 |
| Fluorescence Sensitivity (MESF) | FITC < 10, PE < 5 |
| Flow Rate | 3.66–14.64 µL/min |
| Fluorescence Detection Limit | 20,000 events/sec |
| Cell Analysis Throughput | FITC MESF < 10, PE MESF < 5 |
| Detector Technology | Time-Delay Integration CCD (TDI-CCD) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | guava easyCyte 6-2L |
| Product Type | Flow Cytometer |
| Sample Vial Format | 1.2 mL or 1.5 mL microtubes |
| Fluorescence Channels | Red2 (661/19 nm), Red1 (690/50 nm), Yellow (583/26 nm), Green (525/30 nm) |
| Excitation Lasers | 488 nm blue laser, 638 nm red laser |
| Parameters Measured | 6-parameter (4 fluorescence + 2 light scatter) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | guava easyCyte 6HT-2L |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck Millipore (acquired Amnis) |
| Product Type | Imported Instrument |
| Model | FlowSight |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Category | Imported |
| Model | Mobius® |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Category | Imported |
| Model | Muse |
| Product Type | Flow Cytometry-Based Cell Analyzer |
| Pricing | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SNAP i.d. 2.0 |
| Automation Level | Semi-Automatic Western Blotting System |
| Operating Principle | Vacuum-Driven Fluidic Processing |
| Brand | Millipore |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Steritest™ Symbio with 3-canisters |
| Instrument Type | Fully Automated Sterility Testing System |
| Compliance | Designed for ISO 13408-1, USP <71>, EP 2.6.1, and FDA Aseptic Processing Guidance compliance |
| Software | Embedded touchscreen interface with audit trail, method versioning, and user access control (21 CFR Part 11 ready) |
| Filtration Architecture | Positive-pressure, dual-mode (constant pressure / adaptive flow rate reduction) per canister |
| Display | 11 cm (4.3 in) color LCD with tilt adjustment, multi-language support (EN/FR/DE/IT/ES/PT/JP/CN) |
| Method Storage | Up to 250 programmable sterility test protocols with revision tracking |
| Ergonomics | Low-profile design (≤28 cm height), glove-compatible buttons, adjustable bottle holder, passive cooling, particle-free enclosure |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CellASIC |
| Pricing | Available Upon Request |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MES-Lab |
| Chip Type | High-Pressure Microfluidic Chip |
| Chip Material | Stainless Steel |
| Flow Channel Dimensions | 20 µm – 1 mm |
| Sample Throughput | 0.1–200 mL |
| Target Analyte | Liposomes |
| Emulsion Output Size Range | Down to <100 nm |
| Polydispersity Index (PDI) | <0.1 |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | B-600 |
| Detection Time | 3 s (cuvette mode), 5 s (ultra-micro mode) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 190–1100 nm |
| Wavelength Resolution | 0.3 nm |
| Absorbance Range | 0–300 Abs (10 nm pathlength equivalent) |
| Detection Limit | 2 ng/µL (dsDNA) |
| Upper Detection Limit | 15,000 ng/µL (dsDNA) |
| Sample Volume | 1–2 µL |
| Pathlength Range | 0.01–1.2 mm (auto-adjusting) |
| Detector | 2048-pixel CCD array |
| Light Source | Xenon flash lamp |
| Dimensions | 220 × 280 × 220 mm |
| Weight | 3 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Power Consumption | 80–100 W |
| Compatible Samples | dsDNA, ssDNA, RNA, proteins (BSA), cell cultures (OD₆₀₀) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | LP-80 |
| Sensor Count | 80 PAR quantum sensors (1 cm spacing) |
| PAR Measurement Range (Probe) | 0–2500 µmol·m⁻²·s⁻¹ |
| Resolution | 1 µmol·m⁻²·s⁻¹ |
| Accuracy | ±5% |
| External PAR Sensor | Apogee SQ110, 0–4000 µmol·m⁻²·s⁻¹, Ø24 × 27 mm, 5-pin sealed circular connector, 5 m cable |
| Unattended Sampling Interval | 1–60 min |
| Data Storage | 1 MB RAM |
| Power | 4 × AAA alkaline batteries (typical 2-year field life) |
| Operating Environment | 0–50 °C, 0–100% RH |
| Compliance | ISO 9001:2015, ISO/IEC 17050:2010 (CE marked) |
| Dimensions (Probe) | 865 × 19.0 × 9.5 cm |
| Dimensions (Control Unit) | 15.8 × 9.5 × 3.3 cm |
| Weight (Control Unit, w/batteries) | 0.55 kg |
| Interface | 5-pin sealed circular to RS-232 cable included |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | PHYTOS 31 |
| Dimensions | 12.0 × 5.8 × 0.8 cm |
| Operating Temperature | -40 to +60 °C |
| Cable Length | Standard 5 m (customizable up to 40 m) |
| Interface | 3.5 mm stereo jack or bare wire |
| Supply Voltage | 2.5–5.0 VDC |
| Measurement Time | 10 ms |
| Output Signal | 300–1250 mV (proportional to excitation voltage) |
| Sensor Type | Frequency-Domain Dielectric Sensor |
| Output Resolution Compatibility | ≥12-bit single-ended voltage input |
| Certified Standards | ISO 9001:2015, CE (EMC per ISO/IEC 17050:2010) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | S2-411-SS (upward-facing), S2-412-SS (downward-facing) |
| Principle | Spectral Radiance Ratio Measurement |
| Type | Portable Canopy Sensor Pair |
| Wavelength Peaks | 650 ± 2 nm (Red) and 810 ± 2 nm (NIR), FWHM: 10 nm each |
| Field of View | Upward: 180° (cosine-corrected hemispherical) |
| Downward | 30° full cone |
| Calibration Uncertainty | ±5% |
| Measurement Repeatability | <1% |
| Long-term Drift | <2% per year |
| Response Time | <0.6 s |
| Operating Temperature | −40 to +70 °C |
| IP Rating | IP68 |
| Housing | Anodized Aluminum with Acrylic Diffuser |
| Cable | 5 m shielded twisted pair, TPR jacket, stainless steel connector |
| Power | 5.5–24 V DC |
| Output | SDI-12 compliant |
| Weight (incl. cable) | 140 g |
| Dimensions | Ø30.5 × 37 mm (S2-411-SS), Ø30.5 × 34.5 mm (S2-412-SS) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | S2-421-SS (upward), S2-422-SS (downward) |
| Principle | Effective photosynthetically active radiation (PAR)-weighted reflectance measurement |
| Type | Portable canopy-mounted optical sensor |
| Spectral peaks | 532 ± 2 nm and 570 ± 2 nm |
| FWHM | 10 nm per channel |
| Field of view | 180° (S2-421-SS), 35° (S2-422-SS) |
| Cosine response error | ±2% @ 45°, ±5% @ 75° zenith angle |
| Calibration uncertainty | ±5% |
| Measurement repeatability | <1% |
| Long-term drift | <2% per year |
| Response time | <0.6 s |
| Operating temperature | −40 to +70 °C |
| Relative humidity range | 0–100% RH |
| IP rating | IP68 |
| Power supply | 5.5–24 V DC |
| Output | SDI-12 |
| Housing | Anodized aluminum with acrylic diffuser |
| Cable | 5 m shielded twisted pair, TPR jacket, stainless steel (316) strain relief |
| Weight (incl. cable) | 140 g (S2-421-SS), 110 g (S2-422-SS) |
| Dimensions | Ø30.5 × 37 mm (S2-421-SS), Ø23.5 × 43 mm (S2-422-SS) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC-1 |
| Pricing | Upon Request |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | TEROS 21 |
| Measurement Range | 0 to –100,000 kPa |
| Temperature Range | –40 to +60 °C |
| Resolution | 0.1 kPa / 0.1 °C |
| Accuracy | ±(10% of reading + 2 kPa) from –5 to –100 kPa / ±1 °C |
| Sensor Type | Frequency-domain ceramic matrix with calibrated thermistor |
| Output | SDI-12 or DDI serial interface |
| Power Supply | 3.6–15 VDC |
| Dimensions | 9.6 × 3.5 × 1.5 cm (L×W×D) |
| sensing head diameter | 3.2 cm |
| Cable Length | 5 m (customizable up to 75 m) |
| Compliance | ISO 9001:2015, ISO/IEC 17050:2010 (CE) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | TEROS 31 |
| Measurement Range | –150 to +50 kPa (standard range: –85 to +50 kPa) |
| Temperature Range | –30 to 60 °C |
| Resolution | ±0.0012 kPa / ±0.01 °C |
| Accuracy | ±0.15 kPa / ±0.5 °C |
| Output Protocols | SDI-12, Modbus RTU, TensioLink, DDI Serial |
| Power Supply | 3.6–28.0 VDC |
| Dimensions | 23.5 × 17.5 × 49.0 mm |
| Ceramic Tip Area | 0.5 cm² |
| Rod Diameter | 5 mm |
| Cable Length | 1.5 m |
| Connector | 3.5 mm 4-pole stereo plug |
| Operating Temperature | 0–50 °C |
| Certifications | ISO 9001:2015, CE (EN ISO/IEC 17050:2010) |
| Brand | METHER |
|---|---|
| Model | MDF-86V588 |
| Type | Upright |
| Effective Volume | 588 L |
| Inner Dimensions (W×D×H) | 606 × 738 × 1310 mm |
| External Dimensions (W×D×H) | 891 × 1155 × 1994.5 mm |
| Power Supply | 220 V / 50 Hz |
| Rated Power Consumption | 815 W |
| Temperature Range | –86 °C stable operation |
| Origin | Anhui, China |
| Manufacturer Status | Domestic OEM with certified quality control system |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | CytoDirect |
| Sample Volume | 20 µL |
| Pixel Size | 1.1 µm × 1.1 µm |
| Cell Diameter Range (Counting) | 2–80 µm |
| Display Resolution | 1280 × 800 px |
| Screen Size | 7 in |
| Dimensions (H×W×D) | 60 mm × 128 mm × 260 mm |
| Weight | 1.11 kg |
| Detection Technology | Digital Holographic Microscopy |
| Autofocus | Yes |
| Processing Time | < 15 s |
| Total Imaging Area | 31.28 mm² |
| Sensor Count | 2 |
| Battery | Rechargeable Li-ion |
| Power Input | USB-C |
| Connectivity | Wi-Fi, Ethernet |
| Data Export Formats | CSV, PDF, PNG, RAW |
| Sterilizable | Yes |
| Portability | Yes |
| CV (at > 5 × 10⁶ cells/mL) | ≤ 5% |
| Cell Types Supported | B cells, CHO, HEK293, HeLa, MSC, NK cells, PBMC, RBC, Sf9, T cells, iPSC, monocytes, granulocytes, *Saccharomyces cerevisiae*, oval/round plant cells |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | PlateDirect A96 |
| Detection Method | Absorbance (Optical Density) |
| Function Type | Single-Mode Absorbance Reader |
| Automation Level | Fully Automated |
| Measurement Mode | Endpoint and Kinetic Scanning |
| Microplate Format | 96-well, Flat-Bottom |
| Wavelength Options | Variant 1: 405 nm, 450 nm, 492 nm, 620 nm |
| Variant 2 | 492 nm, 570 nm, 600 nm, 650 nm |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Read Time | ≤5 seconds per 96-well plate |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Numbers | S13005-14 (Straight, Blunt-Blunt, 14.5 cm), S13006-14 (Curved, Blunt-Blunt, 14.5 cm) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-700 Series |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 40,000 psi |
| Max Flow Rate | 15.6 L/min |
| Inlet Temperature Range | Up to 75 °C |
| Power Supply | 3-Phase, 380 V, 15–50 HP |
| Air Supply | 50–150 psi, 1 SCFM @ 50 psi, Dew Point: 0–35 °F |
| Dimensions | 74 × 180 × 145 cm |
| Weight | 675–900 kg |
| Chamber Material | Diamond-Embedded Stainless Steel |
| Construction | Fully 316L Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110Y |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure Range | 3,000–23,000 psi |
| Max. Flow Rate | 250–600 mL/min |
| Feed Temperature Range | –25°C to +75°C |
| Minimum Sample Volume | 14 mL |
| Compressed Air Requirement | 57 scfm at 120 psi, 15 hp (11 kW) |
| Dimensions | 28 × 41 × 76 cm |
| Weight | 25 kg |
| Interaction Chamber Material | Diamond or Ceramic |
| Wetted Parts | 300-series Stainless Steel (Chromium-Plated Piston) |
| Integrated Cooling Coil | 17 ft (13 mL volume) |
| Cleaning | CIP-capable (Clean-in-Place) |
| Certification | Explosion-Proof & Portable Design |
| Brand | MGI |
|---|---|
| Origin | Shenzhen, China |
| Model | DNBelab C-TaiM 4 |
| Instrument Type | Library Construction System |
| Library Type | Single-Cell Library Preparation System |
| Throughput | Independent 4-Channel Configuration |
| Sample Format | Microfluidic Cartridge-Based |
| Core Function | Fully Automated Single-Cell Nucleic Acid Library Construction |
| Regulatory Classification | Research-Use-Only (RUO) Instrument |
| Compliance | Designed for ISO 13485-aligned manufacturing environment |
| Software Validation | Supports audit trail and user access control per FDA 21 CFR Part 11 requirements |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Second-Generation Sequencer |
| Platform | DNBSEQ™ Technology |
| Form Factor | Benchtop |
| Regulatory Status | Medical Device |
| Read Lengths | SE100, PE50, PE150, PE300, SE400 |
| Throughput per Run | 8–96 Gb |
| Q30 Score | >85% (PE150) |
| Run Time | 12 h (PE150) |
| Compliance | CE-IVDR, NMPA Class II/III registered (as applicable), supports 21 CFR Part 11-compliant software modules |