Life Science Instruments
Filter
Showing 4261–4290 of 7567 results
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Second-Generation Sequencer |
| Platform | DNBSEQ™ Technology |
| Form Factor | Benchtop |
| Regulatory Status | Medical Device |
| Read Lengths | SE100, PE50, PE150, PE300, SE400 |
| Throughput per Run | 8–96 Gb |
| Q30 Score | >85% (PE150) |
| Run Time | 12 h (PE150) |
| Compliance | CE-IVDR, NMPA Class II/III registered (as applicable), supports 21 CFR Part 11-compliant software modules |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MGISEQ-T7 |
| Instrument Type | Second-Generation Sequencer |
| Medical Device Classification | Yes (Class II/III per NMPA) |
| Throughput | 1–6 Tb per run |
| Read Lengths | SE50, PE100, PE150 |
| Accuracy | Q30 ≥ 85% (PE100), ≥ 80% (PE150) |
| Run Time | ~20 h (PE100), ~24 h (PE150), ~5 h (SE50) |
| Maximum Effective Reads per Flow Cell | 5,000 M |
| Flow Cells per Run | 1–4 (independently controlled) |
| Data Output per Flow Cell | up to 1.5 Tb |
| Daily Max Output | 6 Tb (4-flow-cell mode) |
| Brand | MGI |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MGICLab-LT Series |
| Pricing | Available Upon Request |
| Instrument Category | Cryogenic Biobanking Systems |
| Footprint | Customizable |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MGS-1/4 |
| Price | Upon Request |
| Brand | MicaSense |
|---|---|
| Origin | USA |
| Model | RedEdge-P Triple |
| Weight | 1080 g (including mounting hardware, DLS2, and cables) |
| Dimensions | 21.9 cm × 11.4 cm × 9 cm |
| RGB Output Resolution | 5.1 MP (global shutter, co-registered with all spectral bands) |
| Multispectral Sensor Resolution | 1456 × 1088 (1.6 MP per band) |
| Panchromatic Resolution | 2464 × 2056 (5.1 MP) |
| GSD at 120 m | 7.7 cm/pixel (multispectral), 3.98 cm/pixel (panchromatic) |
| FOV | 50° H × 38° V (multispectral), 44° H × 38° V (panchromatic) |
| Capture Rate | Up to 3 raw DNG images/sec |
| Spectral Bands | 15 total (comprising narrowband blue, green, red, red-edge ×2–4, NIR ×2, plus panchromatic) |
| Radiometric Calibration | Dual-source (integrated DLS2 + CRP2 reflectance panel) |
| Operating Temperature | 0–40 °C (no airflow), 0–50 °C (airflow >0.5 m/s) |
| IP Rating | IP4X |
| Power Input | 7.0–25.2 V DC |
| Power Consumption | 11 W (standby), 14 W (average), 20 W (peak) |
| Interface | Three configurable GPIOs, USB 2.0 (Wi-Fi), serial, 10/100/1000 Ethernet |
| Storage | CFexpress Type B card |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | R14005-13 |
| Unit Price | USD 39.50 |
| Brand | MICHEM (MechaTech) |
|---|---|
| Origin | United Kingdom |
| Model | Hyscan II |
| Measurement Principle | Quantitative Pressure-Reduction Solidification Method |
| Analysis Time | ≤ 5 min per sample |
| Detection Limit | 0.01 cm³/100 g Al |
| Accuracy | ±<5% RSD |
| Compliance | Designed for GLP/GMP-aligned foundry QA workflows |
| Portability | Benchtop with integrated vacuum system and field-deployable rugged chassis |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | F12002-12 |
| Pricing | Available Upon Request |
| Brand | Micro-Field / Guangzhou Micro-field Optical Technology Co., Ltd. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HM-SR-01 |
| Imaging Modality | dSTORM (direct Stochastic Optical Reconstruction Microscopy) & TIRF (Total Internal Reflection Fluorescence) |
| Objectives | Plan-Apochromat 40×/0.95 (WD: 0.25–0.16 mm) |
| Apochromat 100×/1.45 Oil (WD | 0.13 mm) |
| Excitation Lasers | 405 nm (60 mW), 432 nm (80 mW), 488 nm (20 mW), 561 nm (80 mW), 638 nm (60 mW) |
| Focus Stability | Active autofocus with ≤50 nm axial drift correction |
| Z-Stage | Closed-loop nanopositioning stage (150 µm travel, 0.8 nm resolution) |
| XY-Stage | Motorized stage (110 × 75 mm travel, ±1 µm repeatability) |
| Camera Interface | High-sensitivity scientific CMOS or EMCCD compatible |
| Dimensions | 840 × 345 × 750 mm |
| Brand | LuMeley |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Instrument Type | Semi-Automatic Microbial Filtration System |
| Filtration Capacity | 6 Samples Simultaneously |
| Dimensions (L×W×H) | 670 × 130 × 100 mm |
| Weight | 4.5 kg |
| Compatible Pump | LM-B02 Diaphragm Liquid Pump |
| Surface Finish | Electrolytically Polished & Brushed Stainless Steel |
| Filter Head Mounting | Threaded, Quick-Release |
| Sterilization Compatibility | Autoclavable (reusable cups), Flame-Sterilizable (pump heads), EO/Gamma-compatible (disposable cups) |
| Brand | Microblox |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Microblox-PDMS |
| Chip Material | Polydimethylsiloxane (PDMS) |
| Channel Feature Size | Customizable down to 1 µm |
| System Configuration | Modular, Full Turnkey Lab Integration Supported |
| Compliance | Designed for ISO Class 5–7 cleanroom environments |
| Brand | Microblox |
|---|---|
| Model | ECO-M |
| Category | CO₂ Incubator for Microfluidic Platforms |
| Origin | Beijing, China |
| Temperature Range | Ambient to 50 °C (customizable up to 65 °C) |
| Humidity Range | 5–95% RH |
| Internal Dimensions | 152 × 110 × 32 mm (L × W × H) |
| Chip Compatibility | Standard microscope slides (75 × 25 × 2 mm), dual 45 × 15 × 2 mm formats, PDMS/glass/plastic chips |
| Heating Method | Transparent metal-oxide conductive glass (uniform thermal distribution) |
| Observation Windows | Bottom optical glass (0.7–1.0 mm thick, customizable), top quartz or heated glass |
| Fluidic Interface | 1/16″ stainless steel ferrule ports |
| Gas Interface | Push-to-connect fittings (CO₂/O₂/N₂ mixing capable) |
| Electrical Interface | Quick-lock IEC 60320 C14 input |
| Sensor Accuracy | ±0.1 °C (PT1000 RTD) |
| Optional CO₂ Control | 0–15% v/v, flow rate 0.6–1.0 L/min |
| Brand | Microdrop |
|---|---|
| Origin | Germany |
| Model | Autodrop Gantry ECO |
| Spotting Type | Non-contact piezoelectric inkjet |
| Minimum Spot Size | <5 µm |
| Spotting Throughput | 2000 spots/sec |
| Substrate Capacity | Up to 384-well microplates or standard microscope slides |
| Repeatability & Positioning Accuracy | ±5 µm |
| Compatible Fluid Viscosity Range | 20–10,000 mPa·s (heated operation supported) |
| Drive Technology | Piezoelectric actuation with inert fluidic path (glass/PTFE/PEEK) |
| System Architecture | Modular gantry-based platform with integrated liquid handling and real-time motion compensation |
| Brand | Microfluidic ChipShop (MCS) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Sample Preparation Chip |
| Instrument Type | Microfluidic Chip System |
| Membrane Configuration | Crossflow Filtration Architecture |
| Interface Standard | Luer & Mini-Luer |
| Compatible Sample Volume Range | 25–100 µL Whole Blood |
| Plasma/Serum Yield | 12–35 µL per chip unit |
| Membrane Diameter Options | 10 mm (Fluidic 168/200/1113), Dual-Geometry (Fluidic 783), On-Chip Detection-Optimized (Fluidic 973), Open-Access (Fluidic 234/235), Transwell-Compatible (Fluidic 219) |
| Customization | Membrane Material & Pore Size Available on Request |
| Brand | Microfluidic ChipShop (MCS) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Straight-Channel Chip |
| Instrument Category | Microfluidic Chip System |
| Form Factor | Microscope Slide Format (75.5 × 25.5 × 1.5 mm) & SBS-Compatible Microtiter Plate Format (85.48 × 127.76 mm) |
| Channel Configurations | 4–96 parallel straight channels |
| Interface Options | Through-Hole, Mini Luer, Luer, Olive |
| Channel Dimensions | Widths from 100 µm to 2 mm |
| Material Options | Polycarbonate (PC), Polystyrene (PS), Polymethylmethacrylate (PMMA), Cyclic Olefin Polymer (COP/Zeonor) |
| Surface Functionalization Compatibility | DNA probe spotting, poly-L-lysine, collagen coating, etc. |
| Compliance | Designed for ISO 8601-compliant lab automation workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110EH |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Max Flow Rate | 450 mL/min |
| Inlet Temp. Range | ≤75°C |
| Power Supply | 3-Phase, 380 V, 5 HP (3.7 kW) |
| Fluid Path Volume | 100 mL |
| Compressed Air Requirement | 35–150 psi |
| Dew Point | 0–35°F |
| Minimum Sample Volume | 120 mL |
| Dimensions | 73 × 87 × 148 cm |
| Weight | 205 kg |
| IXC Chamber Material | Synthetic Diamond |
| Regulatory Compliance | CE Certified |
| Cleaning | CIP-Compatible |
| Sterilization | SIP-Capable (Steam or Hot Water) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-140K |
| Pressure Range | 8,000–40,000 psi |
| Maximum Flow Rate | 500 mL/min (material-dependent) |
| Feed Temperature Range | −25–75 °C |
| Power Supply | 3-Phase, 380 V, 5.6 kW (7.5 HP) |
| Minimum Sample Volume | 1 L |
| Compressed Air Requirement | 35–150 psi, 1 SCFM at 50 psi, dew point −17.7–1.6 °C |
| Cooling Water Required | For hydraulic oil and optional product heat exchanger |
| Dimensions | 135 × 156 × 114 cm |
| Weight | 410 kg |
| Certification | CE-compliant |
| Brand | Guangdong Huankai / BHK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MID-64-A |
| Price Range | USD 14,000 – 70,000 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 78001 |
| Pricing | Available Upon Request |
| Max. Speed | 38,000 rpm |
| Control Modes | Manual Trigger & Foot Pedal |
| Mounting Compatibility | Stereotaxic Arm Adapter Interface |
| Drill Bit Options | 0.5–2.3 mm diameter, Round-Tip & Flat-Tip Configurations (HM-series) |
| Brand | NARISHIGE |
|---|---|
| Model | IM-300 |
| Origin | Japan |
| Operating Pressure Range | Up to 7 kgf/cm² (≈686 kPa) |
| Power Consumption | ~35 W |
| Dimensions | 425 × 205 × 90 mm (W × D × H) |
| Weight | 3.7 kg |
| Includes | Inlet/Outlet Tubing, Foot Switch, Silicone Gasket, Power Cord, HI-7 Microinjector Holder |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iTOXcontrol |
| Pricing | Upon Request |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Chip Material | Borosilicate Glass |
| Chip Dimensions | 45 mm × 15 mm × 1800 µm |
| Channel Width | 50 µm |
| Channel Height | 20 µm |
| Internal Volume | 5.0–5.7 µL |
| Inlet/Outlet Count | 1 each |
| Structural Variants | Regular, Random, and Rock-Mimicking (Geologically Representative) |
| Application Domain | Core-scale Fluid Flow Simulation in Porous Media |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | FC_PRO_CH4515, FC_FC4515, Sideconnect Starter Kit (15 mm × 15 mm), Sideconnect Starter Kit (15 mm × 30 mm) |
| Chip Compatibility | Top-Entry Chips (45 mm × 15 mm), Side-Entry Chips (15 mm × 15 mm or 15 mm × 30 mm) |
| Body Material | Aluminum Alloy / Stainless Steel / PEEK |
| Sealing Material | FFKM (Perfluoroelastomer) / PEEK / FEP |
| Max Operating Temperature | 80 °C |
| Max Operating Pressure | 4–5 bar (FC_PRO_CH4515), 100 bar (FC_FC4515), 10 bar (Sideconnect Kits) |
| Optical Access | Full viewing window compatible with upright and inverted microscopy |
| Included Accessories | PTFE tubing, FFKM O-rings, precision-machined fittings |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Model | FF_DROP_75, FF_DROP_50, FF_DROP_10, FF_DROP_SC_5, FF_DROP_SC_10, FF_DROP_SC_50 |
| Chip Type | Droplet Generation Chip |
| Substrate Material | Borosilicate Glass |
| Chip Dimensions | 45 mm × 15 mm (top-connect) or 15 mm × 15 mm (side-connect) |
| Chip Thickness | 1800 µm (top-connect) / 1400 µm (side-connect) |
| Nozzle Diameter | 5–75 µm |
| Channel Height | 17–125 µm |
| Internal Volume | 0.09–4.3 µL |
| Inlets | 2–3 |
| Outlets | 1 |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Model | ooc_membrane 00738, ooc_membrane 01206, ooc_membrane 01060 |
| Substrate Material | Borosilicate Glass |
| Membrane Material | PET |
| Membrane Thickness | 12 µm, 9 µm, 16 µm |
| Pore Size | 0.45 µm, 3 µm, 8 µm |
| Chip Architecture | Three-layer (glass baseplate, PET membrane, glass coverplate) |
| Sealing Method | Mechanical clamping with silicone gaskets |
| Compliance | Designed for ISO 13485-aligned cleanroom fabrication and GLP-compatible experimental workflows |
| Brand | Micronit |
|---|---|
| Origin | Netherlands |
| Chip Material | Borosilicate Glass |
| Chip Dimensions | 45 mm × 15 mm |
| Chip Thickness | 1800 µm |
| Channel Width | 240 µm |
| Channel Height | 150 µm |
| Internal Volume | 2 µL |
| Inlets | 2 |
| Outlets | 2 |
| Mixer Architecture | Teardrop-shaped passive mixing structures |
| Compliance | ISO 13485–compatible manufacturing environment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MicroStep Craniotome System |
| Pricing | Available Upon Request |
| Max Speed | 35,000 rpm |
| Motor Torque | High-torque brushless DC |
| Noise Level | <45 dB(A) at 30 cm |
| Vibration Damping | Active isolation mount integrated |
| Control Options | Manual trigger + footswitch |
| Stall Detection | Audible & visual alarm |
| Drill Bit Compatibility | Nine standard tungsten carbide bits (0.019", 0.027", 0.031", 0.039", 0.047", 0.055", 0.063", 0.071", 0.083") |
| Wireless Handpiece | Rechargeable Li-ion battery (8 h runtime), 14,400 rpm, carbide-shafted tips (0.6 mm, 0.8 mm, 1.0 mm, 1.2 mm, 1.6 mm) |
| Optional Accessory | Part #58610V58609 Drill Bit Kit (sold separately) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Detection Range | DNA, proteins, lipids, and other biomolecules |
| Sample Volume | 0.1–2 mL |
| Injection Volume | Adjustable (50–500 µL typical) |
| Analysis Time | Real-time, down to 1 ms resolution (Biosense 2.5 software) |
| Temperature Control Range | 4–80 °C ± 0.1 °C |
| Detection Limit | <1 ng/cm² |
| Compliance | ISO/IEC 17025-ready architecture, supports GLP/GMP audit trails per FDA 21 CFR Part 11 |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MidiLab9000-Marker |
| Pricing | Available upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-8000 |
| Price Range | USD $14,000–$70,000 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1,000–8,000 psi |
| Max Flow Rate | 1,000 mL/min |
| Feed Temperature Limit | 75 °C |
| Compressed Air Requirement | 57 SCFM at 50 psi, dew point −17.7 to 1.6 °C, 15 hp (11 kW) |
| Minimum Sample Volume | 250 mL |
| Dimensions | 58 × 38 × 58 cm |
| Weight | 26.7 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Cleaning | CIP-capable high-pressure fluid path |
| Drive Mechanism | Pneumatic, explosion-proof |
| Sterilization Compliance | Autoclavable and SIP-compatible components |