| Brand | Mightex |
|---|---|
| Origin | Canada |
| Model | OASIS Macro & Micro Platforms |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Available Upon Request |
| Brand | MILLET |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BactEasy |
| Instrument Type | Automated Digital Colony Counter |
| Counting Speed | 150 colonies per second |
| Camera | 1″ Sony IMX183 CMOS sensor, 20 MP resolution |
| Onboard Computer | 6-core CPU / 8 GB RAM / 256 GB SSD |
| Illumination | Adjustable LED light guide array, 100-step intensity control |
| Illumination Uniformity | ≥90% |
| Petri Dish Compatibility | 90–100 mm diameter |
| Enclosure Material | 6061-T6 aluminum alloy frame + UL94-V0 rated ABS housing |
| Dimensions (W×D×H) | 300 × 300 × 355 mm |
| Weight | 5 kg |
| Brand | Millet |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | MLT-YDYTT |
| Price Range | USD 7,000 – 14,000 |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Configuration | Sterile, Pre-assembled Transwell-Compatible Insert System |
| Membrane Material | Polycarbonate (PCF) or Polyester (PET) |
| Pore Size | 0.4 µm (PCF) or 1.0 µm (PET) |
| Well Count | 24 |
| Format | Integrated Insert + Receiver Plate + Lid |
| Sterility | Certified Sterile, Non-Pyrogenic, DNase/RNase-Free |
| Packaging | Individual Blister Pack or Multi-Pack |
| Compliance | ISO 13485–Certified Manufacturing |
| Intended Use | In vitro cell culture, co-culture, permeability assays, differentiation studies, and barrier function analysis |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | MDCI10000 |
| Dimensions (L×W×H) | 6 in × 11 in × 12 in |
| Weight | 5.67 lb |
| Connectivity | USB / Ethernet / Wi-Fi |
| Sample Compatibility | Adherent cells, microtissues, organoids |
| Data Management | Web-based cloud platform with audit-trail-capable image archiving and time-series growth analytics |
| Regulatory Context | Designed to support GLP-compliant cell culture monitoring |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Type | Epithelial Resistance & Voltage Measurement System |
| Model | Millicell® ERS-2 |
| Measurement Principle | AC-based impedance spectroscopy (12.5 Hz sinusoidal current) |
| Electrode Type | Dual Ag/AgCl miniaturized probe electrodes |
| Probe Tip Diameter | ≤1.0 mm |
| Voltage Range | ±100 mV |
| Resistance Range | 0–10,000 Ω |
| Resolution | 1 Ω (0–1,000 Ω), 10 Ω (1,000–10,000 Ω) |
| Accuracy | ±2% of reading |
| Power Supply | 9 V alkaline battery (included) |
| Compliance | Designed for GLP-compliant TEER monitoring in vitro |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Nucleic Acid & Protein Purification Portfolio |
| Price | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | Japan |
| Model | BM-100 |
| Category | Imported Instrument |
| Primary Function | Automated 2D Electrophoresis Platform |
| Compliance | Designed for GLP-compliant proteomics workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MERS00002 |
| Price | USD 3,950 (excl. VAT & shipping) |
| Voltage Range | ±999.0 mV |
| Voltage Resolution | 0.1 mV |
| Resistance Range | 0–10,000 Ω |
| Resistance Resolution | 1 Ω |
| Excitation Current | ±10 µA nominal at 12.5 Hz AC square wave |
| Power Supply | Rechargeable 6 V NiMH 2200 mAh battery |
| Battery Life | 8–10 hrs per full charge |
| Analog Output | 1–10 V (1 mV/Ω scaling) |
| Operating Temperature | 10–38 °C |
| Relative Humidity | 0–90% non-condensing |
| Dimensions | 19 × 11 × 6 cm |
| Weight | 1.4 kg |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Milliflex® Quantum |
| Instrument Type | Automated Microbial Enumeration System |
| Detection Throughput | 1 sample per run |
| Detection Limit | 1 CFU/sample |
| Filter Area | 55 mm diameter Milliflex membrane |
| Dimensions (Reader) | 14.2 × 24.9 × 12.5 cm |
| Weight | 4.4 kg |
| Power Input | 100–220 VAC, 50–60 Hz |
| Operating Temperature | 15–40 °C |
| Relative Humidity | < 90% |
| Altitude Limit | < 3000 m |
| Compliance | CE-marked, EMC Directive 89/336/EEC |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | NovAseptic® Magnetic Stirrer |
| Pricing | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Scepter 3.0 |
| Measurement Time | ≤30 s per sample |
| Sample Volume | 5 µL |
| Cell Size Detection Range | 10–30 µm |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Throughput | Up to 100 samples per day |
| Principle | Electrical Impedance (Coulter Principle) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SNAP i.d. 2.0 |
| Automation Level | Semi-Automatic Western Blot Processing System |
| Voltage Options | 115 V/60 Hz or 220 V/50 Hz |
| Maximum Membrane Capacity | 6 membranes (simultaneous) |
| Processing Time for Blocking, Washing & Antibody Incubation | ≤30 minutes |
| Compatible Membrane Formats | Single-, Dual-, and Triple-slot blotting cassettes |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Steritest™ Symbio |
| Instrument Type | Fully Automated Microbial Limit Tester |
| Sample Throughput | Up to 6 samples per run (dual-channel parallel filtration) |
| Compliance | Designed for ISO 13408-1, USP <71>, EP 2.6.1, and FDA Aseptic Processing Guidance |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × D × H) | 360 × 420 × 390 mm |
| Weight | 18.5 kg |
| Display | 11 cm (4.3″) color LCD with glove-compatible touchscreen interface |
| Language Support | English, Chinese (Simplified), French, German, Italian, Japanese, Portuguese, Spanish |
| Data Integrity | Audit trail enabled, user access levels (admin/operator), electronic signature support per 21 CFR Part 11 requirements |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Oasis |
| Instrument Type | Automated Microbial Limit Testing System |
| Dimensions (H×W×D) | 90 mm × 230 mm × 310 mm |
| Weight (with filter head) | 3.4 kg |
| Throughput | Up to 6 parallel filtration channels (via connection of up to 3 external vacuum pumps) |
| Design | Benchtop, biosafety cabinet–compatible, low-profile ergonomic base |
| Filtration Integrity | Integrated removable check valve in filter head to prevent backflow contamination |
| Cleanability | Smooth, wipe-clean surface |
| key filter head components accessible and autoclavable (note | pump unit is non-autoclavable) |
| Regulatory Alignment | Designed for compliance with USP <61>, <62>, EP 2.6.12, ISO 8573-7, and FDA 21 CFR Part 11–ready data handling when integrated with validated software |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SMCxPRO™ |
| Compliance | CE-IVD, FDA-cleared for RUO and clinical research use |
| Detection Principle | Digital immunoassay with magnetic bead-based single-molecule counting |
| Sensitivity | Sub-fg/mL (e.g., TNF-α: 0.1 pg/mL |
| IL-2 | 0.2 pg/mL |
| cTnI | 0.4 pg/mL) |
| Dynamic Range | >4 logs (up to 5–6 logs depending on analyte and assay configuration) |
| Sample Throughput | Up to 96 samples per run |
| Sample Types | Human serum, plasma, CSF, saliva, cell culture supernatant |
| Antibody Pairs Validated | >600 pre-qualified matched pairs |
| Software | SMCxPRO™ Control & Analysis Suite v3.2 (21 CFR Part 11 compliant audit trail, user role management, electronic signature support) |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Steritest™ Equinox 3-Canister |
| Instrument Type | Fully Automated Aseptic Testing System |
| Throughput | 3 Samples Simultaneously |
| Filter Pore Size | 0.45 µm |
| Membrane Material | Mixed Cellulose Ester (MCE) |
| Housing Material | Styrene Acrylonitrile (SAN) |
| Tubing Material | PVC |
| Needle Adapter Material | Stainless Steel & Polyamide 6-6 |
| Tubing Length | 850 mm |
| Max Operating Pressure | 3.15 bar at 25°C (45 psi at 77°F) |
| Shelf Life | 2 Years |
| Compliance | Designed for ASTM D1980, USP <71>, ISO 11737-1, and FDA 21 CFR Part 11–ready software architecture |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Model | autoMACS® Pro |
| Automation Level | Fully Automatic |
| Sample Throughput | Up to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run |
| Max Total Cells per Sample | 4 × 10⁹ |
| Max Magnetically Labeled Cells per Sample | 2 × 10⁸ |
| Sample Volume Range | 0.2–50 mL |
| Compatible Starting Materials | Whole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines) |
| Species Compatibility | Human, mouse, rat, non-human primates, and others via indirect MicroBeads |
| Column Types | Reusable autoMACS Columns (single or dual configuration) |
| Separation Modes | Positive selection, untouched isolation, depletion |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Dimensions (w × d × h) | 605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm) |
| Cooling System | Integrated Chill Racks (2–8 °C sample/ reagent storage) |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MACSima |
| Pricing | Upon Request |
| Brand | Mindray |
|---|---|
| Model | BC-60R Vet |
| Origin | Shanghai, China |
| Instrument Type | Veterinary Hematology Analyzer |
| Detection Principle | SF-Cube Platform — Laser Scatter + Fluorescent Staining (S-Scatter & F-Fluorescence) |
| Analysis Dimensionality | 3D Multi-Parameter Cell Discrimination |
| WBC Differential Technology | Third-Generation Animal-Specific Fluorescent Staining |
| Reticulocyte (RET) Detection | Optimized RNA-Specific Fluorescent Dye with 650 nm Excitation |
| Compliance | Designed for GLP-aligned veterinary diagnostic workflows |
| Software | Embedded veterinary-specific analysis algorithms with audit trail capability |
| Brand | Mindray |
|---|---|
| Model | BeneFusion VP3 Vet / SP3 Vet |
| Origin | Shanghai, China |
| Instrument Type | Veterinary Infusion Pump |
| Regulatory Classification | Class II Medical Device (China NMPA) |
| Intended Use | Continuous or intermittent intravenous, intra-arterial, or subcutaneous fluid and drug delivery in veterinary clinical settings |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BS-240 Vet |
| Instrument Type | Veterinary Clinical Chemistry Analyzer |
| Regulatory Certification | CNAS-Accredited Reference Laboratory (ISO/IEC 17025) |
| Sample Volume Minimum | 2 µL |
| Reaction Volume Minimum | 100 µL |
| Temperature Control | Reaction Disk at 37 ± 0.1 °C (enclosed thermostatic system), Reagent Storage at 2–12 °C (continuous refrigeration) |
| Carryover Rate | < 0.05% |
| Software Interface | Fully Localized Chinese GUI with Veterinary-Specific Workflow Logic |
| Parameter Flexibility | Up to 64 selectable assays |
| Reference Intervals | Species-specific (canine and feline), validated against multi-center clinical serum cohorts |
| Data Traceability | AAA Traceability Architecture (Analytical–Algorithmic–Archival), compliant with GLP audit requirements |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ePM 12M Vet |
| Instrument Type | Electrocardiography (ECG)-Enabled Multi-Parameter Veterinary Monitor |
| NIBP Algorithm | Species-Specific Cuff-Based Blood Pressure Algorithm |
| SpO₂ Technology | Motion-Tolerant and Low-Perfusion Resistant Pulse Oximetry |
| ECG Analysis | Multi-Lead Digital Signal Processing with CrozFusion™ Signal Fusion |
| Expandable Modules | CO₂ (Capnography), IBP (Invasive Blood Pressure, up to 4 channels), Cardiac Output (C.O.), Anesthetic Gas (AG), O₂/CO₂ (Artema® Technology) |
| Display | 12.1-inch Capacitive Touchscreen with Gesture Support |
| Data Storage | Internal Flash Memory + USB Export Capability |
| Compliance | IEC 60601-1, IEC 60601-2-51 (for Veterinary Monitors), ISO 13485 Certified Manufacturing |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | UA-60V |
| Instrument Type | Semi-Automated Urine Dipstick Analyzer |
| Operating Temperature | 15–30 °C |
| Operating Humidity | 30–85% RH |
| Power Supply | DC 5 V / 1 A (adapter input: AC 220 V, 50 Hz) |
| Compatible Test Strips | Strips-11 (11-parameter) and Strips-15 (15-parameter) |
| Strip Capacity | 50 strips per roll |
| Shelf Life | 24 months (unopened) |
| Storage Conditions | 0–30 °C, dry, protected from direct sunlight |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | Vetus 9 |
| Imaging Platform | ZST+ Zone Scanning Technology |
| Core Modalities | B-mode, Color/Power Doppler, Pulsed-wave & Continuous-wave Spectral Doppler, Contrast-enhanced Ultrasound (UWN+), Shear Wave Elastography, Tissue Doppler Imaging (TDI), Tissue Tracking Quantification |
| Regulatory Status | CE Marked, FDA 510(k) cleared for veterinary use |
| Intended Use | Diagnostic imaging and functional assessment in companion animals, equine, and large animal clinical practice |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | WATO EX-20Vet |
| Instrument Type | Veterinary Anesthesia Delivery System |
| Compliance | Designed to meet ISO 80601-2-13 (Medical Electrical Equipment – Part 2-13: Particular Requirements for Anesthesia Equipment) and IEC 60601-1 safety standards |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-35Vet |
| Instrument Type | Veterinary Anesthesia and Monitoring System |
| Display | 10.4-inch TFT high-resolution touchscreen |
| Ventilation Modes | Volume-Controlled (VCV), Pressure-Controlled (PCV), Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG), Spontaneous Breathing Support |
| Minimum Tidal Volume | 5 mL |
| Gas Monitoring Options | EtCO₂, Oxygen (O₂), Nitrous Oxide (N₂O), Halogenated Anesthetics (e.g., Isoflurane, Sevoflurane) |
| Vaporizer | Precision V60 calibrated halogenated anesthetic vaporizer (CE & FDA cleared) |
| Breathing Circuit | Integrated dual-mode (rebreathing/non-rebreathing), tool-free soda lime canister replacement |
| Leak Test | Automated self-test with graphical troubleshooting guidance |
| Waste Gas Scavenging | Optional passive or active scavenging system |
| Compliance | Designed to meet IEC 60601-1, IEC 60601-2-13, ISO 80601-2-13, and applicable veterinary medical device regulatory requirements |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-65 Pro Vet |
| Instrument Type | Integrated Veterinary Anesthesia & Ventilation System |
| Regulatory Classification | Class II Medical Device (CN), CE-marked for Veterinary Use |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Z70 Vet |
| Instrument Type | Veterinary Diagnostic Ultrasound System |
| Display | 15-inch Full-View LCD Touchscreen |
| Application Focus | Canine, Feline, Equine, Bovine, and Ovine Imaging |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | MJ-70-I / MJ-150-I / MJ-250-I / MJ-300-I |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range | 0–60 °C |
| Temp. Uniformity | ±0.5 °C (at high temp), ±1.0 °C (at low temp) |
| Temp. Resolution | 0.1 °C |
| Humidity Control | Optional microprocessor-based system (Model “II”) |
| Max. Timer Setting | 99 h 59 min |
| Programmable Stages | Up to 15 segments × 30 steps (optional controller) |
| Internal Chamber Volume | 70 L to 300 L |
| Refrigerant | R134a or R406a (eco-friendly, non-CFC) |
| Air Circulation | JAKEL centrifugal blower + optimized duct design |
| Safety | Independent over-temperature cutoff with audible/visual alarm |
| UV Sterilization | Top-mounted germicidal UV lamp (254 nm) |
| Interface Options | RS485, USB (optional), printer/data logger compatibility |