Life Science Instruments
Filter
Showing 4351–4380 of 7558 results
| Brand | Molecular Devices |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QPix 400 |
| Instrument Type | Fully Automated Microbial Colony Screening and Picking System |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | QPix FLEX |
| Detection Method | Fluorescence Intensity |
| Functionality | Multimodal |
| Automation Level | Fully Automated |
| Assay Type | Automated Microbial Identification & Colony Isolation |
| Detector Type | Fluorescence Imaging Sensor |
| Sample Handling | Integrated Liquid Handling, Streaking, Plating, and Colony Picking |
| Dimensions | Compact Footprint (Designed for Benchtop & Anaerobic Chamber Integration) |
| Traceability | 2D Barcode Scanning for Microplate & Pick Log Registration |
| Compliance Context | Supports GLP/GMP-aligned workflows with full audit trail capability |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QPix FLEX |
| Instrument Type | Fully Automated Microbial Colony Picking and Screening System |
| Dimensions | 600 × 650 × 620 mm (W × D × H) |
| Weight | 48 kg |
| Operating Environment | Compatible with standard lab benches and anaerobic chambers (O₂ < 1%) |
| Imaging System | High-resolution color CMOS camera with adjustable white balance and dynamic exposure control |
| Pick Accuracy | >99% |
| Throughput | Up to 1,200 colonies per hour (dependent on plate layout and pick strategy) |
| Tip Options | Sterilizable stainless-steel pins and disposable polymer pins (tool-free switching) |
| Liquid Handling | 4-channel positive-displacement pipettor, volume range 1–200 µL, CV < 3% at 20 µL |
| Data Traceability | Integrated 2D barcode scanner for plate-level and pick-event-level audit trail |
| Software Compliance | Supports ALCOA+ principles |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument Software |
| Model | SoftMax Pro GxP v7.1.1 |
| Functionality | Multi-Mode Microplate Data Acquisition & Analysis Platform |
| Automation Level | Fully Integrated GxP-Compliant Software for Microplate Readers |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SpectraMax ABS & ABS PLUS |
| Function Type | Single-Mode Absorbance Detection |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Detector Type | Grating Monochromator |
| Wavelength Range | ABS PLUS: 190–1000 nm |
| ABS | 340–850 nm |
| Absorbance Range | –0.000 to 4.000 OD |
| Absorbance Linearity | 0.000–4.000 OD |
| Read Speed | 96-well plate: 9 s |
| 384-well plate | 29 s |
| Accuracy | < ±0.003 OD ±1.0% (0–2 OD) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SpectraMax Drop |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SpectraMax Gemini EM |
| Function Type | Dedicated Fluorescence Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan, Well-Scan |
| Curve Fitting | SoftMax Pro software supports 11 standard curve models (e.g., 4PL, 5PL, linear, exponential) |
| Detector Type | Photomultiplier Tube (PMT) |
| Excitation & Emission Wavelength Range | 250–850 nm |
| Wavelength Accuracy | < ±2 nm |
| Wavelength Scanning Speed | ≤15 sec per scan (full range) |
| Dual Monochromator Architecture | Independent excitation and emission grating monochromators |
| Reading Modes | Top-read and bottom-read fluorescence |
| Well-Scan Capability | Multi-point per well (up to 9×9 grid) |
| Plate Formats | 6–384-well microplates, including tissue-culture treated and membrane-based plates |
| Compliance | FDA 21 CFR Part 11 compliant with optional IQ/OQ/PQ documentation packages and SpectraTest™ FL1 Performance Verification Kit |
| Brand | Molecular Devices |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SpectraMax i3x |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software |
| Detector Types | Photomultiplier Tube (PMT) and Photodiode |
| Wavelength Ranges | Absorbance 230–1000 nm |
| Absorbance Range | 230–1000 nm |
| Absorbance Linearity | 0–2.0 OD |
| Optical Density Accuracy | ±0.010 OD (±1.0% from 0 to 2 OD) |
| Precision | <0.01 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SpectraMax iD3 |
| Detection Methods | Absorbance, Fluorescence, Luminescence |
| Functionality | Multi-mode |
| Automation Level | Fully Automated |
| Assay Formats | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software (Log-Log, 4PL, 5PL, PLA) |
| Detector Type | PMT and Photodiode |
| Wavelength Ranges | Absorbance 230–1000 nm |
| Absorbance Range | 0–4.0 OD |
| Linearity | ±0.010 OD (0–2.0 OD) |
| 96-Well Absorbance Read Time | ≤25 sec |
| Temperature Control | Ambient to 65 °C |
| Plate Formats | 6–384-well, SpectraDrop™ Microvolume Plates |
| Scan Density | Up to 20 × 20 wells/plate |
| Optical System | Dual-monochromator (QuadraGrating™), Xenon Flash Lamp, Cooled (−5 °C) PMT |
| Injection System | Dual SmartInject™ Reagent Injectors with Overflow Protection |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready via SoftMax Pro GxP Edition |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SpectraMax iD3 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software-Based |
| Detector Type | PMT and Photodiode |
| Wavelength Range | Absorbance 230–1000 nm |
| Absorbance Range | 230–1000 nm |
| Absorbance Linearity | 0–2.0 OD |
| Absorbance Speed | 96-well plate in 25 sec |
| Accuracy | < ±0.010 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SpectraMax iD3 |
| Detection Methods | Absorbance, Fluorescence, Luminescence |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | SoftMax Pro Software-Based |
| Detector Types | Photomultiplier Tube (PMT), Photodiode |
| Wavelength Ranges | Absorbance 230–1000 nm |
| Absorbance Range | 230–1000 nm |
| Absorbance Linearity | 0–2.0 OD |
| Absorbance Speed | 96-well plate in 25 sec |
| Accuracy | < ±0.010 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SpectraMax iD3s |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | SpectraMax iD5 |
| Detection Modes | Absorbance, Fluorescence (including TRF, FP), Luminescence (top/bottom), TR-FRET, HTRF, BRET, Dual-Luciferase (with injectors) |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.010 OD or ±1.0% (0–3.0 OD) |
| Detector | –5°C Cooled Photomultiplier Tube (PMT) and UV-Enhanced Silicon Photodiode |
| Wavelength Scanning Speed | 30 sec per scan |
| Temperature Control | Ambient to 66°C |
| Shaking Modes | Linear, Orbital, Double-Orbital |
| Plate Formats | 6–384-well, including Western blot membranes |
| Optical System | Hybrid Quad-Grating + Filter-Based Pathway |
| Scan Density | Up to 20 × 20 points per well |
| Software | SoftMax Pro 7 with GxP Compliance (21 CFR Part 11, GLP/GMP audit trail) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SpectraMax iD5 |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Methods | ELISA, Kinase Assays, Nucleic Acid & Protein Quantitation, Reporter Gene Assays (e.g., Dual-Luciferase), Calcium Flux, TR-FRET, HTRF, BRET, Western Blot Imaging |
| Curve Fitting Models | Linear, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL), Logarithmic, Power, Double-Logarithmic |
| Detector Types | –5°C Cooled Photomultiplier Tube (PMT) and UV-Silicon Photodiode |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±0.010 OD or ±1.0% (whichever is greater) across 0–3.0 OD |
| Wavelength Scan Speed | ≤30 seconds per full spectrum |
| Precision | <±0.010 OD ±1.0% (0–3.0 OD) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SpectraMax iD5e |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | SpectraMax L |
| Functionality | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Fast Kinetic, Dual-Color Luminescence |
| Curve Fitting | SoftMax Pro Software (supports 4PL, 5PL, linear, log-log, spline, and custom equation models) |
| Detector | Low-Noise Photomultiplier Tube (PMT) with Synchronous Ultra-Fast Photon Counting |
| Wavelength Range | 380–630 nm |
| Absorbance Range | Not applicable (chemiluminescence-only instrument) |
| Linearity Range | 380–630 nm (luminescence spectral response) |
| Read Time per Plate | ≤10 seconds (96-well, single-channel) |
| Precision (CV) | <0.001 (R² for calibration curves), typical inter-well CV <2.5% across dynamic range |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SpectraMax M2 |
| Functionality | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Full-Wavelength Scan, Single-Well Scan |
| Curve Fitting | SoftMax Pro Software (Comprehensive Nonlinear Regression Library) |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 250–850 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | 0–3 OD |
| Plate Read Time | 18 sec per 96-well plate |
| Absorbance Precision | < ±0.005 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SpectraMax M4 |
| Functionality | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Full-Wavelength Scan, Single-Well Multi-Point Scan |
| Curve Fitting | SoftMax Pro Software (supports 4PL, 5PL, linear, quadratic, sigmoidal, exponential, and custom equation models) |
| Detectors | Dual Photomultiplier Tubes (PMTs) + Four Photodiodes |
| Wavelength Range | 200–1000 nm (Abs) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | 0–3 OD |
| Plate Read Time | 18 sec per 96-well plate |
| Absorbance Precision | < ±0.005 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | SpectraMax M5 |
| Detection Methods | Absorbance, Fluorescence Intensity (FI), Fluorescence Polarization (FP), Time-Resolved Fluorescence (TRF), Luminescence |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan, Well Scan |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Linearity | 0–3 OD |
| 96-Well Plate Scan Speed | 18 sec |
| Absorbance Precision | <0.005 OD |
| Detectors | Dual PMT + 4 Photodiodes |
| Cuvette Slot | Integrated |
| HTRF® Certified | Yes |
| PathCheck™ Technology | Yes |
| Temperature Control | Precise incubation with virtual lid |
| Software | SoftMax Pro GxP (21 CFR Part 11 compliant) |
| Validation Kits | ABS1, FL1, LM1 |
| Automation Compatibility | StakMax stacker (up to 50 plates), LIMS & robotic integrations |
| Microvolume Capability | Compatible with SpectraDrop™ (2 µL, 24/64-well format) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SpectraMax Mini |
| Detection Methods | Fluorescence Intensity, Absorbance, Luminescence |
| Functionality | Multimode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL) |
| Detector | Thermoelectrically Cooled (–5°C) Photomultiplier Tube (PMT) and Photodiode |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±2 nm |
| Wavelength Switching Speed | <1 second per wavelength |
| Absorbance Accuracy | <±0.003 OD ±1.0% (0–3 OD) |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SpectraMax Mini |
| Functionality | Multimode |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, Spectral Scanning |
| Curve Fitting Options | Linear, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL) |
| Detector | Thermoelectrically Cooled Photomultiplier Tube (PMT) at –5°C and Silicon Photodiode |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±2 nm |
| Wavelength Scan Speed | >1 well/sec |
| Absorbance Accuracy | < ±0.003 OD ±1.0% (0–3 OD) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SpectraMax MiniMax 300 Cell Imaging System |
| Instrument Type | Optical Imaging System |
| Compatibility | Designed exclusively for integration with SpectraMax i3x Multi-Mode Microplate Readers |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SpectraMax Paradigm |
| Detection Methods | Absorbance, Fluorescence Intensity (FI), Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), Homogeneous Time-Resolved Fluorescence (HTRF), AlphaScreen/AlphaLISA, Chemiluminescence (GL) |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan, Linear Scan, Well Scan |
| Wavelength Range | 230–1000 nm |
| Absorbance Range | 0–3.5 OD (linear) |
| Wavelength Accuracy | ±1 nm |
| Photometric Precision | ±1% + 0.005 OD |
| Detector System | Dual Independent Photomultiplier Tubes (PMTs) |
| Upgrade Mechanism | Hot-swappable Application-Specific Cartridges (≤2 min installation) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SpectraMax Plus384 |
| Detection Method | Absorbance (UV-Vis-NIR) |
| Function Type | Single-Mode Absorbance Reader |
| Automation Level | Fully Automated Microplate Reader |
| Assay Modes | Endpoint, Kinetic, and Spectral Scan |
| Curve Fitting | SoftMax Pro Software with Comprehensive Algorithm Library (Including Linear, Log-Log, Four-Parameter Logistic, etc.) |
| Detector Type | Photodiode Array (PDA)-Based Dual-Beam Optical System |
| Wavelength Range | 190–1000 nm (Monochromator-Based Continuous Scanning) |
| Absorbance Range | 0–4.0 OD |
| Linearity Range | 0–3.0 OD (R² ≥ 0.999) |
| Wavelength Switching Speed | ≤9 seconds per wavelength |
| Absorbance Precision | ±0.006 OD (at 0.5 OD, 450 nm, n=20) |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SpectraMax® M3 |
| Functionality | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Full-Wavelength Scanning, Well-Scan (Single-Well Point Scan) |
| Curve Fitting | SoftMax Pro Software (Supports 4PL, 5PL, Linear, Log-Log, Exponential, and Custom Equations) |
| Detectors | Dual Photomultiplier Tubes (PMTs) + Four Silicon Photodiodes |
| Wavelength Range | 200–1000 nm (Abs) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | 0–3 OD (R² ≥ 0.999) |
| Read Time per 96-Well Plate | ≤18 sec |
| Absorbance Precision | < ±0.006 OD |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Molecular Devices, LLC |
| Product Type | Imported Instrument |
| Model | Threshold® |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Momentum |
| Instrument Type | Tomographic Imaging |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Speed | 10 s per volume |
| Field of View (FOV) | 6 cm × 6 cm × 12 cm |
| Sample Capacity | 1 animal |
| Brand | Monaco |
|---|---|
| Model | MS-1 |
| Type | Manual Microplate Heat Sealer |
| Compatible Plate Formats | 96-well and 384-well microplates |
| Sealable Materials | Pressure-sensitive sealing films and adhesive films |
| Additional Compatibility | Flat-cap 8-tube strips |
| Construction | Corrosion-resistant stainless steel housing |
| Operating Principle | Manual thermal compression sealing |
| Origin | Jiangsu, China |
| Regulatory Classification | CE-compliant design for laboratory use under ISO 13485-aligned manufacturing practices |
| Brand | Monad |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AutoDrip 1 |
| Pricing | Available Upon Request |
| Dispensing Range | 5–2000 µL |
| Precision & Accuracy | <3% CV and %Error (per ISO 8655-6) |
| Calibration | Dual-point volumetric calibration (low/high range) |
| Compatible Plate Formats | 24-well, 48-well, 96-well microplates |
| Pump Technology | Dual-head peristaltic pump system |
| Included Tubing Sets | Five pre-calibrated disposable tubing paths (GLA9005–GLA9009) |
| Standard Accessories | Small nozzle holder (GLA9001), large nozzle holder (GLA9002), small-pump calibrator (GLA9003), spare small-nozzle gaskets (5/pk, GLA9004) |