| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE |
| Filtration Rating (Liquid) | 0.22 µm & 0.45 µm |
| Filtration Rating (Gas) | 0.01 µm |
| Bubble Point | ≥ 0.08 MPa (95% IPA) |
| Diffusion Flow | ≤ 5.5 mL/min (60:40 IPA:Water at 0.064 MPa) |
| Gas Flow Rate (Hydrophobic, 0.01 µm) | ≥ 6 m³/min (ΔP = 0.015 MPa at 0.13 MPa inlet) |
| Water Flow Rate (Hydrophilic, 0.22 µm) | ≥ 6.89 L/min (ΔP = 0.01 MPa at 0.13 MPa inlet) |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Reverse Pressure | 0.21 MPa @ 25°C |
| Max Service Temperature | 65°C @ 0.21 MPa (Standard), 95°C @ 0.1 MPa (High-Temp Grade) |
| Sterilization | 142°C @ 0.276 MPa (Autoclave) |
| Online Steam | 135°C @ 0.1 MPa, 30 min per cycle (up to 160 cycles) |
| Max ΔP for Replacement | 0.20 MPa |
| Housing Material | Polypropylene (PP) |
| Core Support | PP, 304 SS, or 316 SS |
| End Cap & Connector | PP |
| Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Food-Grade EPDM, Silicone, or FKM |
| Effective Filtration Area | 0.70 m² (10-inch format) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE-NWF |
| Filtration Rating | 0.2 µm (liquid), <0.01 µm (gas), <0.003 µm (dual-layer) |
| Max Operating Temperature | 90 °C @ 0.20 MPa |
| Sterilization | 121 °C, 30 min (≥50 cycles) |
| Forward Pressure Rating | 0.42 MPa @ 25 °C |
| Reverse Pressure Rating | 0.21 MPa @ 25 °C |
| Endotoxin Level | <0.25 EU/mL |
| Extractables | <10 mg per 10-inch cartridge (Φ69 mm) |
| Chemical Resistance | Broad compatibility with acids, bases, and organic solvents |
| Brand | NeuronBC |
|---|---|
| Model | PVDF |
| Filter Material | Polyvinylidene Fluoride (PVDF) Microporous Membrane |
| Filtration Area (10″) | 0.60 m² |
| Liquid Sterile Filtration Rating | 0.22 µm |
| Gas Filtration Rating | 0.01 µm |
| Bubble Point (Isopropanol, 0.22 µm) | ≥ 0.065 MPa |
| Air Flow Rate | ≥ 6 m³/min at ΔP = 0.015 MPa (inlet pressure 0.13 MPa) |
| Forward Pressure Drop | 0.42 MPa at 25 °C |
| Reverse Pressure Drop | 0.21 MPa at 25 °C |
| Operating Temperature | ≤ 65 °C (standard), ≤ 95 °C (high-temp grade, 0.1 MPa) |
| Steam Sterilization | 121 °C, 0.1 MPa, 30 min per cycle (validated for ≥ 100 cycles) |
| Housing & Endcap Material | Polypropylene (PP) or PVDF |
| Core Support | Imported Polyester Nonwoven |
| Seal Material | Silicone or FKM (Fluoroelastomer) |
| Chemical Compatibility | Broad resistance to strong acids, aliphatic/aromatic hydrocarbons, ketones, ethers, and halogenated solvents |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 68506 |
| Pricing | Upon Request |
| Base Plate Dimensions | 400 mm × 255 mm |
| Ear Bar Angle | 18° |
| Ear Bar Scale Resolution | 0.1 mm |
| Ear Bar Height from Base | 55.5 mm |
| Track Length | 255 mm |
| Track Zero Alignment | Coincident with Ear Bar Center |
| Track Graduation Range | ±100 mm from Zero |
| Adapter Anterior–Posterior Travel | 43.5 mm |
| Adapter Vertical Adjustment Range | +10 mm to –20 mm (30 mm total) |
| Vertical Adjustment Resolution | 0.1 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NeuroStar LA-Stereo |
| Price Range | USD 7,000 – 14,000 |
| Track Travel Range | ±100 mm (200 mm total), 0.1 mm resolution |
| Positioning Accuracy | 100 µm (vernier scale readout) |
| Arm Rotation | Vertical ±90°, Horizontal 360° |
| Max. Mounted Arms | 6 (dual parallel rail system) |
| Upgrade Option | Digital Readout (DRO) Kit Available |
| Animal Compatibility | Canis lupus familiaris, Macaca fascicularis, Sus scrofa, Rattus norvegicus, Mus musculus (with species-specific adapters) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Lite Series |
| Quotation | Available Upon Request |
| Base Plate Dimensions | 400 mm × 255 mm |
| Inter-aural Rod Height Above Base | 35.5 mm |
| Ear Bar Groove Scale Resolution | 0.1 mm |
| Ear Bar Graduation Range | 35 mm (1 mm graduation) |
| Adapter Anterior–Posterior Travel | 43.5 mm |
| Adapter Vertical Adjustment Range | 30 mm (−20 mm to +10 mm), 0.1 mm resolution |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NeuroStar Lite Mouse Stereotaxic Instrument |
| Pricing | Available Upon Request |
| Base Plate Dimensions | 255 mm × 255 mm |
| Ear Bar Material | Polyoxymethylene (POM) |
| Incisor Bar Vertical Adjustment Range | 0–20 mm |
| Ear Bar Vertical Adjustment Range | 0–20 mm |
| Ear Bar Graduation Scale | 1 mm resolution |
| Included Ear Bars | Two pairs — 18° and 45° blunt-tipped |
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | NB Innova 40 R |
| Instrument Type | Refrigerated Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Operation |
| Oscillation Speed | 25–500 rpm |
| Orbit Diameter | 190 mm (standard), 250 mm (Innova 40 R) |
| Temperature Range | 5°C above ambient to 80°C |
| Platform | Single 46 × 46 cm stainless-steel shaker platform |
| Certifications | cETL, UL, CSA, CE |
| Sample Capacity | Up to three 3-L Erlenmeyer flasks simultaneously |
| Brand | New Chi / SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TDL |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 0.5–15 mL |
| Number of Simultaneous Channels | 4 |
| Cooling Compatibility | Ice-bath or pre-chilled adapter (1.5–2 mL × 4 wells) |
| Control Mode | Programmable pulsed/continuous operation |
| Memory Capacity | Up to 50 user-defined protocols |
| Safety Features | Real-time temperature monitoring, overload protection, auto-diagnostic error reporting |
| Compliance | Designed for GLP-compliant labs |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-302M |
| Detection Principles | Catalytic Combustion (LEL), Galvanic Cell (O₂), Electrochemical (H₂S, CO) |
| Detection Gases | Combustible Gas (CH₄), Oxygen (O₂), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO) |
| Measurement Ranges | 0–100% LEL |
| 0–25 vol% (extended | 25.1–50 vol%) |
| 0–30 ppm (extended | 30.1–150 ppm) |
| 0–101 ppm (extended | 100–300 ppm) |
| Accuracy | ±2% LEL |
| Response Time | ≤25 s (1 m sampling tube) / ≤40 s (8 m sampling tube) |
| Operating Temperature | −10 °C to +40 °C, ≤95% RH |
| Power Supply | 4 × AA alkaline batteries |
| Continuous Operation | >8 h (20 °C, alarms/background light/data hold OFF) |
| Enclosure Rating | Intrinsic Safety (Ex ibd II BT3), LEL sensor: Flameproof (Ex d) |
| Dimensions | 152 × 152 × 42 mm (excl. protrusions) |
| Weight | ~870 g |
| Display | Backlit LCD (simultaneous 4-gas readout) |
| Alarms | 90 dB audible buzzer, flashing red LED, visual display alert |
| Key Functions | Auto backlight, flow-under detection (pressure sensor), battery/temperature/clock display, zero calibration, data hold, peak hold, alarm silencing, volume adjustment, alarm self-test |
| Standard Kits | 1-m or 8-m sampling hose configurations with filter/floating buoy, carrying case, or aluminum transport case with external alarm & AC adapter |
| Optional | Windows-compatible data logging kit (Windows 2000/XP) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-308B |
| Detection Principle | Potentiostatic Electrolytic (with DNPH-coated filter for VOC interference reduction) |
| Measurement Range | 0.01–0.38 mg/m³ (service range: 0.39–3.00 mg/m³) |
| 0.01–0.30 ppm (service range | 0.31–3.00 ppm) |
| Sampling Method | Micro-pump–driven active aspiration |
| Measurement Duration Options | 10-min or 30-min integrated sampling modes |
| Display | Digital LCD with bar graph and status indicators |
| Power Supply | Six AA alkaline/manganese batteries or optional DC 9 V AC adapter |
| Battery Life | ~50 measurements (30-min mode) / ~100 measurements (10-min mode) using manganese batteries |
| Filter Lifetime | 50 measurements (30-min mode) / 100 measurements (10-min mode) at 0.10 mg/m³ average formaldehyde concentration |
| Operating Temperature | 5–40 °C |
| Dimensions | 175 × 140 × 86 mm (W × H × D) |
| Weight | Approx. 2.5 kg (including batteries) |
| Data Storage | 32 measurement records |
| Accessories Included | Three DNPH filter cartridges, six AA manganese batteries, sampling tube, ten particulate filter discs, tweezers |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3110 |
| Detection Principle | Catalytic Bead (Pellistor) |
| Detection Range | 0–10% LEL and 0–100% LEL (dual-range) |
| Display | 4-digit LCD with backlight |
| Accuracy | ±5% of full scale |
| Response Time (T90) | <3 seconds |
| Alarm Threshold | 20% LEL (audible/visual) |
| Power Supply | 4 × AA alkaline batteries (6 V DC) |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions | 82 mm (W) × 162 mm (H) × 36 mm (D) |
| Weight | ~450 g (including batteries) |
| Sampling Method | Built-in micro diaphragm pump (active draw) |
| Certification | Intrinsically Safe (Ex ib IIB T4 Ga) |
| Compliance | JIS T 8201, JIS Z 8001, JIS C 0901, ATEX Directive 2014/34/EU (via representative EU importer), IEC 60079-0/-11 |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3140 |
| Weight | 450 g |
| Power Supply | AA alkaline batteries or dedicated rechargeable battery pack |
| Display | Dual-mode (digital + bar-graph) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Bead (Contact Combustion) |
| Detection Method | Pump-Aspirated |
| Measurable Gases | Combustible gases & vapors of combustible organic solvents (e.g., diesel, propane, methane, hexane) |
| Range | 0–5000 ppm or 0–1 vol% (auto-ranging) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm / 500 ppm (user-selectable) |
| Display | Backlit LCD with dual-mode output — numeric (0–5000 ppm / 0–1 vol%) and bar-graph scale (auto-switching between L-range: 0–500 ppm / 0–1000 ppm and H-range: 0–5000 ppm / 0–1 vol%) |
| Alarm Output | Audible buzzer + red LED flash (gas/fault) |
| Intrinsic Safety Rating | Ex ib d IIB T3 (combined intrinsic safety + flameproof enclosure) |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | Four AA alkaline batteries or optional Ni–Cd rechargeable pack |
| Battery Life | ~20 h (alkaline, no alarm/backlight), ~5 h (Ni–Cd, no alarm/backlight) |
| Dimensions | 82 × 162 × 36 mm (W × H × D) |
| Weight | ~450 g (without batteries) |
| Data Logging | Internal memory (standard) |
| Flow Anomaly Self-Check | Yes |
| Accessories Included | Leather carrying case, 4 × AA alkaline batteries, 1 m sampling hose, filter cartridge, filter disc, stainless steel probe tube, rubber suction tip |
| Optional Accessories | Extended sampling hose, gas mixer, data download kit (CD-ROM + USB cable), Ni–Cd battery pack, charger |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-329M |
| Sensor Type | High-sensitivity tin oxide (SnO₂) sintered semiconductor |
| Display | 7-segment LED, 3.5-digit (000–999) |
| Measurement Range | 000–999 arbitrary odor units |
| Repeatability | ±5% ±1 digit (under identical conditions) |
| Sampling Method | Active aspiration (flow rate: 350 ± 100 mL/min) |
| Response Time (90%) | ≤20 s (with calibration odor) |
| Power Supply | 3 × AA alkaline batteries |
| Battery Life | Up to 10 h (at 25°C, typical use) |
| Operating Environment | 0–40°C, 10–80% RH (non-condensing) |
| Storage Environment | −10–50°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 60 × 140 × 40 mm (excl. protrusions) |
| Weight | ≈300 g (incl. batteries) |
| Analog Output | DC 0–0.99 V (corresponding to 000–999 display) |
| Data Memory Capacity | 18,000 records |
| Included Accessories | Filter unit, 3 × AA alkaline batteries, set of 10 filter discs |
| Brand | New Environmental Protection Industry in Qingdao |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XY-HS006 |
| Internal Dimensions | 2200 × 1400 × 1500 mm |
| External Dimensions | 2800 × 1300 × 1400 mm |
| Filtration Efficiency | ≥99.95% for 0.3 µm particles |
| Rated Power | ≤3000 W |
| Noise Level | ≤70 dB(A) |
| Air Supply Volume | Not specified (redundant entry in source |
| Occupancy Capacity | 1–3 operators |
| Pass-Through Window Internal Size | 400 × 400 × 400 mm |
| Weight | 500 kg |
| Average Illuminance | ≥350 lx |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VisioTracker by NewBehavior |
| Pricing | Available Upon Request |
| Brand | FUJIKIN |
|---|---|
| Origin | Japan |
| Model | 112-605 |
| Power Supply | 100 V, 50/60 Hz AC |
| Maximum Stack Capacity | 25–30 sheets (64 g/m² paper) |
| Punch Cycle Time | 0.5 s per stroke (50/60 Hz) |
| Dimensions (W×D×H) | 277 × 436 × 308 mm |
| Weight | 37.7 kg |
| Die Block Compatibility | MOLE 605-112 |
| Compliance | Designed for GLP/GMP-aligned documentation integrity workflows |
| Brand | NewtonOptic |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 12 Samples per Run |
| Sample Volume Range | 50–1000 µL |
| Brand | Nexcope |
|---|---|
| Model | NSR950 |
| Technology | Structured Illumination Microscopy (SIM) |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 640 nm |
| Lateral Resolution | ≤86 nm (TIRF-SIM), ≤115 nm (3D-SIM) |
| Field of View | Square inscribed in Φ22 mm |
| Imaging Speed | 120 fps |
| Eyepieces | 10× (25 mm field number), EP 17.5 mm, diopter adjustment range −5 to +5 |
| Objectives | 10×, 20×, 40×, 60×, 100× |
| Brand | nGauge |
|---|---|
| Origin | USA |
| Model | BI2500 (3-channel SPR), BI4500 (5-channel modular SPR) |
| Detection Range | <100 Da |
| Sample Volume per Channel | <32 nL |
| Minimum Injection Volume | >50 µL |
| Data Acquisition Rate | 4 ms per point |
| Temperature Control | Ambient (RT only) |
| Configuration | Modular flow-cell architecture with electrochemical, gas-phase, and liquid-phase sensing options |
| Brand | BIO-RAD |
|---|---|
| Origin | USA |
| Model | NGC NFC |
| Max Flow Rate | 200 mL/min |
| Collection Vessel Compatibility | 96-well plates, microcentrifuge tubes, conical tubes, glass vials, and custom containers |
| Optional Features | Peltier-based cooling (4–25 °C), automated calibration routine |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, supports audit trail generation per FDA 21 CFR Part 11 requirements (when used with compliant NGC Chromatography Software) |
| Vendor Type | Authorized Distributor |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NicePlate-10 |
| Price Range | USD 1,400 – 2,800 |
| Dispensing Volume Range | 0–30 mL |
| Pump Speed | 0.1–600 rpm |
| Flow Rate | 0.006–2300 mL/min |
| Compatible Vessels | Petri Dishes (standard 90 mm diameter, up to 9 positions), Test Tubes, and Custom Open-Top Containers |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NicePlate-20 |
| Instrument Type | Fully Automatic Microbial Media Dispensing System |
| Dispensing Range | 1–1000 mL |
| Accuracy at 15 mL | ±1% |
| Throughput | 400 Petri Dishes/hour |
| Compatible Dish Diameters | Ø90 mm (standard), 55 mm, 35 mm, 70 mm |
| Adjustable Dish Height | 12–26 mm |
| Dispensing Interval | 1–10 sec |
| UV Lamp Output | 2.3 W @ 254 nm |
| Brand | NIKON |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | E100, EI |
| Instrument Type | Upright Microscope |
| Eyepiece Configuration | Binocular |
| Optical System | CFI Infinity-Corrected |
| Magnification Range | 40×–1500× |
| Illumination | 6 V / 20 W Halogen Lamp with Condenser |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (Coarse Travel: 22 mm |
| Coarse Rotation | 37.7 mm/rev |
| Fine Rotation | 0.2 mm/rev |
| Minimum Graduation | 2 µm) |
| Eyepiece Tube | E2-TB Binocular (30° Inclination, 360° Rotatable, Interpupillary Distance: 47–75 mm) |
| Condenser | Abbe Condenser, NA 1.25, Filter Holder for 33 mm Filters (Including Standard Blue Filter) |
| Objective Turret | 4-Position, Mechanical Centering, Multi-Ball Bearing Rotation |
| Objectives | Plan Achromat 4×, 10×, 40×, 100× (Anti-Fungal Coating) |
| Stage | Dual-Layer Mechanical Stage (155 × 134 mm), Graduated Movable Slide Clips |
| Weight | ~7.3 kg |
| Power Consumption | 50 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Model | E200 |
| Optical System | CFI60 Infinity-Corrected |
| Magnification Range | 40×–1000× |
| Eyepiece Tube | E2-TB Binocular (hinged, 30° inclination) or E2-TF Trinocular (30° inclination, 360° rotation, interpupillary distance 47–75 mm) |
| Eyepieces | CFI E10×/20 mm (field number 20 mm), optional CFI 15×/12 mm |
| Objectives | CFI E Plan Achromat 4× (NA 0.10), 10× (NA 0.25), 40× (NA 0.65), 100× oil (NA 1.25) |
| Nosepiece | Internal quadruple revolving nosepiece |
| Stage | Rectangular mechanical stage (216 × 150 mm), X–Y travel 78 × 54 mm, low-position coaxial controls, auto-return focusing mechanism |
| Condenser | E2 Abbe condenser (NA 1.25) with iris diaphragm and objective position markers |
| Illumination | 6 V / 20 W halogen lamp, centerable and height-adjustable |
| Focus Mechanism | Coarse focus (37.7 mm per revolution), fine focus (0.2 mm per revolution, 2 µm graduation), adjustable coarse torque, built-in stage stop for high-magnification protection |
| Compliance | Designed for ISO 10993-5 biocompatibility of user-contact components |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Configuration | Binocular |
| Illumination | High-Efficiency White LED (60,000 hr lifetime) |
| Optical System | CFI60 Infinity-Corrected |
| Eyepiece Field Number | 20 mm (10×), 12 mm (15×) |
| Objective Mount | Inclined Quadruple Nosepiece |
| Condenser | E2 Abbe Condenser, NA 1.25 |
| Focusing | Coaxial coarse/fine focus, fine focus graduation: 2 µm, coarse travel per revolution: 37.7 mm, fine travel per revolution: 0.2 mm |
| Stage | Rectangular mechanical stage, 216 × 150 mm, 78 × 54 mm travel |
| Ergonomic Tilting Eyepiece Tube | 30° inclination, interpupillary adjustment 47–75 mm, eyepoint height adjustable up to +34 mm |
| Anti-Fungal Protection | Integrated anti-mold coating and desiccant strips, validated for continuous operation at 30°C / 80% RH for ≥36 months |
| Compliance | Designed to support ISO/IEC 17025-compliant documentation workflows |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-E |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | Motorized CI-CE (NA 0.9 / 0.22), Abbe (NA 0.9), Achromatic (NA 0.8), Darkfield Oil (NA 1.2–1.43), Phase Contrast (NA 0.9), Apochromatic (NA 1.4), LWD Achromatic (NA 0.65) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter turret), D-FL (6-filter turret), ND4/ND8/ND16, Excitation Noise Suppression |
| Fluorescence Illuminators | C-LEDFI LED Epi-Illuminator, C-HGFI/HGFIE Fiber-Coupled 130 W Mercury Arc |
| Power Consumption | 6–38 W (Configuration-Dependent) |
| Weight | ~13.4–15.4 kg (Depending on Configuration) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | Eclipse Ci-L PLUS |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Efficiency LED (5.0 W) |
| Eyepiece Field of View | 22 mm (binocular), 25 mm (trinocular) |
| Eyepiece Tube Diameter | Φ30 mm |
| Focusing | Coaxial coarse/fine focus with 30 mm travel, 1 µm fine focus increment |
| Stage Travel | 78 × 54 mm (X–Y) |
| Stage Height Adjustment | Adjustable handle + optional shims |
| Ergonomic Tilting Head | 10°–30° inclination, 40 mm extension |
| Weight | 13.3 kg (binocular configuration) |
| Compliance | CE, ISO 13485 (design & manufacturing processes), RoHS-compliant components |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-L |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | CI-CE Motorized (NA 0.9 / 0.22), C-AB Abbe (NA 0.9), C-PH Phase Contrast, C-DO Oil Darkfield (NA 1.2–1.43), C-DD Dry Darkfield (NA 0.8–0.95), C-AA Achromat-Apochromat (NA 1.4) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter cube capacity), D-FL (6-filter cube capacity), ND4/ND8/ND16, Excitation Noise Suppression |
| Epi-Illuminators | C-LEDFI LED, C-HGFI/C-HGFIE Fiber-Coupled Mercury (130 W) |
| Power Consumption | 6–38 W (Config-Dependent) |
| Weight | ~13.4–15.4 kg (Configuration-Dependent) |