Life Science Instruments
Filter
Showing 4591–4620 of 7558 results
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Static Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Bore Diameter | 60 mm |
| Application Scope | In vivo MRI of mice and rats using MR contrast agents |
| Target Applications | Spontaneous tumor detection (brain, subcutaneous, liver), longitudinal tumor growth & therapy response monitoring, obesity phenotyping, MR contrast agent development |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H+ |
| Pricing | Upon Request |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Animal RF Coil ID | 60 mm |
| Primary Applications | In vivo murine MRI for oncology, obesity, contrast agent development, and longitudinal disease modeling |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NM42-060H-I |
| Quotation | Upon Request |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Dedicated Animal RF Coil Diameter | 60 mm |
| Species Compatibility | Live mice and rats |
| Primary Application | In vivo glioma modeling, tumor progression monitoring, therapeutic response assessment, contrast agent evaluation |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Gradient Coil Bore Diameter | 60 mm |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo small animal MRI (mouse/rat), contrast agent evaluation, tumor monitoring (brain, subcutaneous, liver), obesity phenotyping, longitudinal therapeutic response assessment |
| Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42+ |
| Instrument Type | Preclinical MRI System for Rodent Research (Mouse/Rat) |
| Resonance Frequency | ~42 MHz |
| Static Magnetic Field Strength | 1.0 ± 0.05 T |
| Bore Diameter | 60 mm (Dedicated Animal RF Coil) |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo cell tracking, contrast agent evaluation, tumor modeling, metabolic phenotyping, longitudinal studies in mice and rats |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I-1 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Imaging System |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T ± 0.05 T |
| Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Capacity | 1–350 g (mice, rats, excised tissues) |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001 |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001 |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-3 |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 25 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | QMR |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR Series |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Core Magnet | Permanent Magnet |
| Measurement Principle | Quantitative Low-Field NMR Relaxometry |
| Software | NIUMAG Proprietary Mouse Body Composition Analysis Suite |
| Compliance | Designed for GLP-aligned preclinical metabolic studies |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Application | In Vivo Rodent Metabolism Quantification (Mice, Rats, Rabbits) |
| Measurement Time | 1–3 min per scan |
| Sample State | Conscious, Non-Invasive, No Anesthesia or Sacrifice Required |
| Core Output Parameters | Fat Mass, Lean Body Mass, Total Body Water (TBW) |
| Compliance Context | Designed for GLP-aligned preclinical research workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Animal Compatibility | Live mice, rats, rabbits |
| Measurement Time | < 60 s per subject |
| Output Parameters | Fat Mass, Lean Body Mass, Total Body Water |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Software | Proprietary NMR quantification suite with audit trail capability |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | Live Mice and Rats |
| Primary Measurement | Fat Mass, Lean Body Mass, Free Water Content |
| Magnet Type | Permanent Magnet |
| Test Duration | ≤ 60 s per animal |
| Sample Preparation | None (Non-invasive, Non-anesthetized, Non-terminal) |
| Compliance Context | Designed for GLP-aligned preclinical metabolic phenotyping workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | QMR06 Series |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Type | Live Rodents (Mice, Rats, Rabbits) |
| Measurement Time | < 60 s per sample |
| Measured Parameters | Fat Mass, Lean Mass, Free Water Content |
| Software | Integrated QMR Analysis Suite with GLP-Compliant Audit Trail |
| Regulatory Compliance | Designed to support ISO/IEC 17025-aligned workflows and FDA 21 CFR Part 11–ready data integrity architecture |
| Application Scope | Preclinical metabolic phenotyping, longitudinal obesity/diabetes studies, pharmacological intervention monitoring |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-060H-PRO |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Sample Capacity | Single mouse (up to 50 g) or rat (up to 300 g) |
| Core Functions | In vivo quantification of fat mass, lean body mass, and total body water |
| Magnet System | Permanent magnet (low-field, ~0.06 T) |
| Measurement Time | ≤ 60 s per scan |
| Sample Preparation | Non-invasive, no anesthesia, no euthanasia required |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QMR06-060H-PRO |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Sample Types | Live rats, mice, rabbits |
| Measurement Time | ≤ 60 seconds per animal |
| Measured Parameters | Fat mass, lean tissue mass, free water content |
| Sample Preparation | None required (non-invasive, conscious or lightly restrained animals) |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | In Vivo Small Animal (Rat/Mouse) Body Composition Analyzer |
| Sample Capacity | ≤800 g |
| Core Functions | Fat Mass, Lean Body Mass, Total Body Water Quantification |
| Construction | Benchtop Permanent-Magnet NMR System |
| Magnet Type | Permanent Magnet |
| Measurement Time | <60 s per scan |
| Sample Requirement | Conscious, Unanesthetized, Non-invasive |
| Regulatory Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | 60 mm Bore — 10–100 g |
| Core Functions | In vivo quantification of total fat mass, lean tissue mass, and free water content |
| Magnet System | Permanent Magnet (Low-Field, ~0.3–0.5 T typical for QMR platforms) |
| Measurement Time | ≤ 60 s per subject |
| Sample Preparation | None — conscious or lightly restrained live animals only |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | QMR06-090H-PRO |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Types | Live rats, mice, rabbits |
| Measurement Time | ≤ 60 s per scan |
| Measured Parameters | Fat mass, lean tissue mass, free water content |
| Software | Integrated proprietary NMR quantification platform with GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Hardware Architecture | Benchtop low-field NMR system (0.06–0.09 T) |
| Sample Handling | Non-invasive, non-destructive, no anesthesia or euthanasia required |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Rodent Analyzer (Mouse/Rat) |
| Magnet Type | Permanent Magnet |
| Measurement Time | < 60 s per animal |
| Sample Requirement | Live, conscious, unrestrained |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Species Compatibility | Mus musculus, Rattus norvegicus, Oryctolagus cuniculus |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-090H-PRO |
| Instrument Type | Research-Grade Small Rodent Analyzer |
| Sample Capacity | 800 g |
| Magnet Type | Permanent Magnet |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) |
| Species Compatibility | Live Rats, Mice, and Rabbits |
| Measurement Time | ≤ 60 s per sample |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Sample Preparation | Non-invasive, No Anesthesia or Euthanasia Required |
| Software | Integrated LF-NMR Acquisition & Quantification Suite with GLP-Compliant Audit Trail |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR1 |
| Instrument Type | Research-Grade Small Animal (Mouse) Body Composition Analyzer |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) Relaxometry |
| Sample State | Conscious, Non-Invasive, Anesthesia-Free |
| Typical Scan Time | 60–180 s per mouse |
| Output Parameters | Fat Mass (g), Lean Mass (g), Total Water Mass (g), %Fat, %Lean, %Water |
| Magnet System | Permanent Magnet (0.3–0.5 T typical range) |
| RF Probe | Dedicated Quadrature Mouse-Sized RF Coil |
| Software | NIUMAG Small Animal Body Composition Analysis Suite (v4.x+) |
| Regulatory Compliance | Designed for GLP-aligned workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR12-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (NMR) Analyzer |
| Spatial Resolution | 0.1 mm |
| Field of View (FOV) | 100 mm × 100 mm |
| Magnet Type | Permanent Magnet |
| Probe | Dedicated Body Composition RF Coil |
| Measurement Mode | Non-invasive, Anesthesia-Free, In Vivo |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | PG16300 |
| Price | USD 670 (FOB) |
| Filter Area | 63.5 cm² (Φ100 mm), 132.6 cm² (Φ150 mm), 243.2 cm² (Φ200 mm), 572.2 cm² (Φ300 mm) |
| Max Operating Pressure | 0.8 MPa |
| Sterilization | Autoclavable at 121°C for 30 min |
| Housing Material | ASTM A240 UNS S31603 (316L stainless steel) |
| Gasket Material | Medical-grade silicone rubber |
| Inlet/Outlet | Hygienic clamp-type quick-release fittings (DIN 11851 / ISO 2852 compliant) |
| Surface Finish | Electropolished to Ra ≤ 0.4 µm |
| Chemical Compatibility | Enhanced by PTFE-coated wetted surfaces |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Callisto LN Series |
| Pricing | Available Upon Request |