Life Science Instruments
Filter
Showing 4531–4560 of 7558 results
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-S |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | CI-CE Motorized Dual-NA (0.9 / 0.22), C-AB Abbe (0.9), C-AR Achromatic (0.8), C-DO Oil Darkfield (1.2–1.43), C-DD Dry Darkfield (0.8–0.95), C-PH Phase Contrast (0.9), C-AA Apochromatic (1.4), C-SA Sliding Achromatic (2–100×), C-SW Swing-out Achromatic (1–100×), C-SWA Swing-out Achromatic (2–100×), C-LAR LWD Achromatic (0.65) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter cube capacity), D-FL (6-filter cube capacity), ND4/ND8/ND16, Excitation Noise Suppression |
| Epi-Fluorescence Light Sources | C-LEDFI LED Illuminator, C-HGFI/C-HGFIE Fiber-Coupled 130 W Mercury Arc |
| Power Consumption | 6–38 W (Configuration-Dependent) |
| Weight | ~13.4–15.4 kg (Depending on Configuration) |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E100 |
| Microscope Type | Upright Biological Microscope |
| Eyepiece Configuration | Binocular |
| Optical System | CFI Infinity-Corrected Optics |
| Illumination | High-Efficiency LED (60,000 hr lifetime) |
| Objective Series | CFI BE Plan Achromat |
| Condenser | Abbe Condenser, NA 1.25 |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (2 µm fine graduation) |
| Stage | Dual-layer Mechanical Stage (155 × 134 mm) |
| Eyepiece Inclination | 30° |
| Interpupillary Distance Range | 47–75 mm |
| Eye-point Adjustment Range | 34 mm |
| Optional Accessories | Phase Contrast Rings (10×, 40×, 100×), Darkfield Annuli (10×, 20×, 40×), Filter Holder (33 mm) |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E100 Trinocular |
| Optical System | CFI Infinity-Corrected |
| Observation Head | E2-TF Trinocular, 30° Inclination, Interpupillary Distance 47–75 mm |
| Eyepieces | CFI E 10×/18 (standard), optional CFI E 15×/12 |
| Objective Turret | Quadruple Nosepiece |
| Objectives | CFI BE Plan Achromat 4×, 10×, 40×, 100× (oil), optional 20×, 60× |
| Condenser | Abbe Condenser, NA 1.25, 33 mm Filter Holder |
| Focusing | Coaxial Coarse/Fine Focus, Fine Focus Graduation 2 µm, Coarse Travel 37.7 mm/rev, Fine Travel 0.2 mm/rev, Total Travel 22 mm |
| Stage | Double-Layer Mechanical Stage, 155 × 134 mm |
| Illumination | High-Efficiency White LED (60,000 h lifetime), Constant CCT across intensity range, IR-free, low heat, low power consumption |
| Accessories | Phase Contrast Annuli (10×, 40×, 100×), Darkfield Rings (10×, 20×, 40×), Pointer, Mirror, Power Cord Clip, Protective Packaging (Aluminum Case) |
| Anti-Fungal Treatment | Applied to eyepieces, objectives, and observation tube |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E200 Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Observation Head | Trinocular (E2-TF), 30° Inclination, Interpupillary Distance 47–75 mm |
| Eyepieces | CFI 10×/20 mm Field Number (FN) |
| Objective Lenses | CFI E Plan Achromat 4×, 10×, 40×, 100× (anti-fungal coated) |
| Nosepiece | Inclined 4-position Revolving Nosepiece |
| Condenser | E2 Abbe Condenser, NA 1.25 |
| Focusing Mechanism | Coaxial Coarse/Fine Focus, Fine Focus Graduation 2 µm, Coarse Travel 37.7 mm/rev, Fine Travel 0.2 mm/rev |
| Stage | Rectangular Mechanical Stage, 216 × 150 mm, Travel Range 78 × 54 mm |
| Illumination | LED Light Source (60,000 hr lifetime), Constant CCT Across Intensity Range, IR-Free, Low Heat & Power Consumption |
| Anti-Fungal Protection | Internal Anti-Mold Coating + Desiccant Mold-Prevention Strips (validated for 3 years at 30°C / 80% RH) |
| Ergonomics | Adjustable Tilting Eyepiece Tube (±30°), Height-Optimized Stage Controls, Low-Profile Knob Placement |
| Compatibility | CFI60 Objective Mount, Full Eclipse Series Accessory Ecosystem (Phase Contrast, Fluorescence, Polarization, Digital Imaging) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ji |
| Optical System | CFI Infinity Optics |
| Microscope Type | Inverted Fluorescence Microscope |
| Observation Modes | Brightfield & Epi-Fluorescence |
| Field Number | 25 |
| Camera | 7.8 MP Monochrome CMOS Sensor |
| Bit Depth | 12-bit / 8-bit |
| Max Frame Rate | 18 fps |
| Output Resolution | 2800 × 2800 pixels |
| Focus Drive | Motorized PFS (Perfect Focus System) |
| Focus Travel | ~10 mm |
| Max Focus Speed | 2.5 mm/sec |
| PFS Method | Infrared Projection-Based Focus Maintenance |
| Stage Travel (X/Y) | ±59 mm / ±39.5 mm |
| Max Stage Speed | ~25 mm/sec |
| Objective Turret | 6-position, Motorized |
| Filter Cube Capacity | 6 positions (wide-field compatible) |
| Filter Turret Drive | Motorized |
| Light Source | D-LEDI2 LED Fluorescence Illuminator |
| Illumination | Köhler LED Transmitted Light |
| Interface | USB 3.0 (SuperSpeed), USB-B connector |
| Input Voltage | 100–240 VAC ±10%, 50/60 Hz |
| Power Consumption | 320 W |
| Compliance | UL, CE, RoHS |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | Nikon ECLIPSE Ni-E (Objective-Focusing Type) |
| Optical System | CFI60 and CFI75 Infinity-Corrected Optics |
| Focusing Mechanism | Motorized Objective Nosepiece Translation (±13 mm vertical travel) |
| Linear Encoder Resolution | 0.025 µm |
| Illumination | High-CRI LED (50,000 hr lifetime) or 12V/100W Halogen |
| Eyepiece FOV | 22 mm or 25 mm |
| Motorized Components | NI-N7-E 7-Position Objective Turret, NI-S-E XY Stage (0.1 µm resolution), NI-TT2-E Motorized Quad-Port Tilting Trinocular Tube |
| Compliance | Designed for GLP/GMP-compliant imaging workflows with audit-trail-ready control architecture |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-E |
| Optical System | CFI60 and CFI75 Infinity-Corrected |
| Focusing Mechanism | Motorized Stage (±13 mm total travel, 0.025 µm encoder resolution) |
| Illumination | 12V/100W Halogen or High-CRI LED (50,000 hr lifetime) |
| Objective Turret Options | NI-N7-E (7-port motorized), NI-ND6-E (6-port DIC motorized), NI-N7-I (7-port smart) |
| Stage Options | NIE-CSRR2 (manual ceramic-coated, 78 × 54 mm), NI-S-E (motorized XY, 0.1 µm resolution) |
| Condenser Options | NI-CUD-E (motorized dry, NA 0.88), C-AB (Abbe, NA 0.90), C-PH (phase contrast turret), D-CUO (DIC oil, NA 1.40) |
| Eyepieces | CFI 10X (22 mm FOV), CFI 12.5X (16 mm), CFI 15X (14.5 mm), CFI UW10X (25 mm) |
| Tube Options | C-TE2 (ergonomic binocular), NI-TT2-E (motorized quad-port, 15–35° tilt) |
| Power Consumption | ≤211 W (halogen + full motorization), ≤96 W (LED + full motorization) |
| Weight | 18–32 kg (configuration-dependent) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-L |
| Optical System | CFI60 and CFI75 Infinity-Corrected Optics |
| Focusing Mechanism | Motorized Stage and/or Motorized Nosepiece (Z-travel: up to 13 mm / down to 2 mm) |
| Z-Axis Resolution | 0.025 µm (linear encoder) |
| Illumination | 12V/100W Halogen or High-CRI LED (50,000 h lifetime) |
| Optional Components | NI-N7-E 7-Position Motorized Nosepiece, NI-S-E Motorized XY Stage (0.1 µm resolution), NI-TT2-E Motorized Tilting Quad-Port Tube, NI-RPZ-E Motorized Zoom Port (0.6×–2.0×), NI-CUD-E Motorized Universal Condenser (NA 0.88) |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-U |
| Optical System | CFI60 Infinity-Corrected |
| Focusing Mechanism | Motorized Stage & Nosepiece |
| Illumination | 12V 100W Halogen / High-CRI LED (50,000 hr lifetime) |
| Objective Turret Options | NI-N7-E (7-port motorized), NI-ND6-E (6-port DIC motorized), NI-N7-I (7-port smart) |
| Stage Travel | 78 × 54 mm (manual), 0.1 µm resolution (NI-S-E motorized) |
| Encoded Z-Focus | 0.025 µm resolution |
| Condenser | NI-CUD-E (NA 0.88, motorized universal dry) |
| Eyepiece FOV | 22 mm or 25 mm |
| Port Options | C-mount, F-mount, variable zoom (0.6×–2.0×), DSC ports with magnification adapters |
| Power Consumption | ≤211 W (max halogen + full motorization) |
| Weight | 18–32 kg (configuration-dependent) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Si |
| Optical System | CFI60 Infinity-Corrected Optics |
| Illumination | High-Brightness White LED (Eco-Friendly) with Built-in Köhler Illumination via Fly’s Eye Lens |
| Filter Capacity | Two 45 mm Filters (Optional) |
| Light Intensity Management (LIM) | Yes |
| Focus Mechanism | Coaxial Coarse/Fine Focus (Dual-Side Controls) |
| Focus Travel | +2 mm (Above Top Position) / −13 mm (Below Top Position) |
| Coarse Focus | 37.7 mm per Revolution |
| Fine Focus | 0.2 mm per Revolution |
| Minimum Graduation | 2 µm |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-A |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (TI2-C-TC-E) supporting 7 positions (ø37 mm × 4, ø39 mm × 3), including LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Stage | Motorized XY stage (TI2-S-SE-E): ±57 mm X, ±36.5 mm Y, max speed 25 mm/s |
| Objective Turret | 6-position motorized nosepiece with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Filter Turret | 6-position motorized filter cube turret (TI2-F-FLT-E) with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp housing |
| Software Integration | Compatible with NIS-Elements AR/VR/CV platforms |
| Environmental Rating | Indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-E |
| Type | Inverted Research Microscope with Motorized Precision Optomechanics |
| Optical System | CFI60 Infinity-Corrected, Field Number 22 (Eyepiece), Field Number 16 (Camera Port) |
| Intermediate Magnification | 1.0× / 1.5× (field-upgradable to 2.0×) |
| Focus Drive | Motorized coarse/fine focusing, 10 mm travel, minimum step size 0.01 µm (encoder-controlled) |
| Condenser Turret | Motorized 7-position (TI2-C-TC-E), supporting LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Objective Nosepiece | 5-position motorized with Perfect Focus System (PFS) and correction collar control |
| Epi-Fluorescence Filter Turret | 6-position motorized (TI2-F-FLT-E) with integrated shutter |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y), max speed 25 mm/s, magnetic sample holder |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp |
| Software Compatibility | NIS-Elements AR/C/VR, supports FDA 21 CFR Part 11 compliance modules, GLP/GMP audit trail logging |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-U |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (7-position, supports LWD/ELWD/CLWD/HNA/NAMC objectives) |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y, max speed 25 mm/s) |
| Nosepiece | 6-position motorized objective revolver with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Turret | 6-position motorized filter turret with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED) and fiber-coupled epi-fluorescence modules |
| Environmental Rating | 0–40 °C, ≤60% RH (non-condensing), indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2 |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including Plan Apochromat Phase), DIC-like Relief Contrast*¹ |
| Fluorescence Capability | Yes (Ts2-FL variant) |
| Illumination | High-Brightness White LED Transmitted Light (with Köhler illumination via built-in fly-eye lens) |
| Eyepiece Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Port Split: 100/0 or 0/100 |
| Focusing Mechanism | Objective Nosepiece Movement (7 mm up / 1.5 mm down), Coarse Focus: 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) |
| Stage | Flat Stage (170 × 247 mm) |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 V AC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (T-PH), Differential Interference Contrast (DIC)-like Relief Contrast, Epifluorescence |
| Illumination | High-Brightness White LED Transmitted Light + Modular LED Epifluorescence (385, 455, 470, 505, 525, 560, 590, 625 nm) |
| Eyepiece Field Number | 22 (10×), 16 (15×), 12.5 (20×) |
| Tube Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Trinocular Port (100/0 or 0/100 beam splitter) |
| Focus Travel | 8.5 mm total (7 mm upward, 1.5 mm downward) |
| Coarse Focus | 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) with Pre-centered and Centerable Phase Contrast Sliders (for 10×, 20×, 40×) and Relief Contrast Sliders (dual-side configuration required) |
| Stage | Fixed Plate Stage (170 × 247 mm) with Acrylic Circular Cover Slip |
| Compatible with Multiple Sample Holders | CS-HP35 (35 mm dish), CS-HLP100 (100 mm dish), CS-HT (Terasaki plate & Ø65 mm dish), CS-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal holder for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide holder), C-S-HLS (circular cover slip kit) |
| Fluorescence Attachment | Motorized Filter Cube Turret (3 positions + brightfield slot), Integrated Noise-Reduction Mechanism, Optional Light Shield |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TMC), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Fluorescence Epi-Illumination, Spindle Observation |
| Illumination | High-Brightness White LED Transmitted Light (with Homogenizing Lens), LED Epi-Illumination (up to 4 interchangeable units |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10× (22 mm FOV), 12.5× (16 mm), 15× (14.5 mm) |
| Binocular Tube | Siedentopf-type, interpupillary distance 50–75 mm, tilt angle 35° (standard) or 15–45° (ergonomic) |
| Camera Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-movement |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Objective Turret | 6-position, with DIC prism slots |
| Condenser | Rotating condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Stage Adapters | C-S-HP35 (35 mm dish), C-S-HLP100 (100 mm dish), C-S-HT (Terasaki plates & Ø65 mm dishes), C-S-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide), C-S-HLS (circular slide kit), TC-S-HA (acrylic stage plate) |
| Fluorescence Accessories | Motorized filter cube turret (body-integrated, noise-reduction design) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A |
| Power Consumption | 30 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TIRF-capable phase), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Spindle Observation, Epifluorescence |
| Illumination | High-Intensity White LED Transmitted Light (with Köhler illumination and built-in fly-eye lens) |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10×/22, 12.5×/16, 15×/14.5 field number |
| Trinocular Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-axis movement (8 mm upward, 3 mm downward travel) |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Nosepiece | 6-position revolver with DIC prism slots |
| Condenser | Multi-position condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Fluorescence Accessories | Motorized filter cube turret (with noise-reduction mechanism) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A, 30 W max |
| Brand | NIKON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Patch-Clamp Electrophysiology System |
| Pricing | Available Upon Request |
| Brand | Nikon |
|---|---|
| Origin | Germany |
| Model | TS2 |
| Microscope Type | Inverted Microscope |
| Eyepiece Configuration | Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Focusing Mechanism | Coaxial Coarse/Fine Adjustment |
| Working Distance | Up to 75 mm (with LWD condenser) |
| Condenser Options | Long Working Distance (NA 0.3, WD 75 mm) and Hoffman Modulation Contrast (NA 0.4, WD 44 mm) |
| Fluorescence Capability | Optional Epi-Fluorescence Attachment (up to two filter cubes, 50 W mercury lamp) |
| Camera Port | Standard C-mount compatible port for Nikon digital cameras and third-party imaging systems |
| Ergonomic Design | 45° inclined trinocular head, 400 mm eye-point height, adjustable interpupillary distance (50–75 mm) |
| Stage Height | 195 mm above bench surface |
| Stage Clearance | 190 mm between stage and condenser |
| Phase Contrast | Equipped with Nikon ADL (Apodized Diffraction-Limited) Phase Contrast Objectives |
| Compliance | Designed for GLP-compliant documentation workflows |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DNU-8020 |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Operating Frequency | 35–40 kHz |
| Ultrasonic Power Output | 50 W |
| Sample Volume per Tube | 2 mL |
| Maximum Simultaneous Samples | 8 |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | JY88-PRO |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 4.5–450 W |
| Sample Volume Capacity | 10–200 mL |
| Sample Throughput | Single-sample mode |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1000 mL |
| Sample Throughput | Single-sample processing |
| Transducer Material | Titanium Alloy Probe |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Sample Throughput | Single-sample processing per cycle |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | L1.5-8 Series |
| Temperature Range | –80 °C to 20 °C |
| Temperature Accuracy | ±0.5 °C |
| Control Algorithm | PID Fuzzy Logic |
| Communication Interface | RS-485 with MODBUS RTU Protocol |
| Display | 7-inch color touchscreen with real-time temperature curve visualization and logging |
| Programmability | Up to 5 multi-step programs (30 segments per program) |
| Temperature Feedback Points | Three independent PT100 inputs (unit internal temp, outlet fluid temp, external process material temp) |
| Safety Protections | Compressor overload protection, high-pressure switch, thermal relay, overheat sensor, low-fluid-level detection, sensor fault monitoring, self-diagnostic system |
| Circulation System | Fully sealed closed-loop design |
| Fluid Operating Range | –25 °C to 200 °C |
| Temperature Differential Control | Adjustable setpoint offset between jacket and process material temperature |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1.5 L (total) |
| Throughput | 8 or 16 samples per run |
| Cooling Interface | Integrated recirculating chiller port (4–10 °C operational range) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-08-II |
| Instrument Type | Non-contact ultrasonic cell disruptor (cup-horn system) |
| Operating Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 1800 W |
| Sample Volume Range | 5 µL – 15 mL |
| Sample Capacity | 1–16 tubes |
| Power Adjustment Range | 1–99% |
| Timer Range | 1–999 min |
| Duty Cycle | 0.1–99.9% |
| Tank Volume | 1.5 L |
| Compatible Vessel Formats | 1–2 mL × 16 wells, 5 mL × 8 wells, 10–15 mL × 8 wells |
| Temperature Monitoring | Yes |
| Input Voltage | 220/110 V ±0.5%, 50/60 Hz |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2200 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1–2 mL, 5 mL, or 10–15 mL per tube |
| Throughput | 17, 20, or 32 samples per run |
| Cooling System | Integrated recirculating chiller-compatible jacket (operating range: 4–10 °C) |
| Sample Container Compatibility | Standard microcentrifuge tubes (1.5/2.0 mL), PCR strips, and custom cryovials |
| Control Interface | Digital touchscreen with programmable protocols (time, amplitude, pulse mode, cycle count) |
| Safety Certification | CE-compliant design |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ-08-IIIA |
| Pricing | Upon Request |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 20 kHz (±0.5 kHz) |
| Sample Volume Capacity | 900 mL |
| Sample Throughput | 1 tube per cycle (rotating holder supports single-tube continuous rotation) |
| Temperature Control | Integrated jacketed cup with external chiller compatibility (4–10 °C typical operational range) |
| Cooling Interface | Dual-layer borosilicate glass cup with external recirculating coolant port |
| Minimum Sample Volume | 5 µL |
| Acoustic Isolation | Built-in acoustic enclosure with transparent viewing window |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCIENTZ-08-IIID |
| Pricing | Upon Request |