Life Science Instruments
Filter
Showing 4561–4590 of 7558 results
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-1000J |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 1000 W (adjustable in 1% increments) |
| Duty Cycle | 0.1–99.9% |
| Sample Volume Capacity | 10–200 mL |
| Alarm Functions | Overtemperature, Overload, and Timer Alert |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 50–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Multi-sample Processing Capability | Yes |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-16TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Processing Capacity | 16 samples |
| Cooling Mode | Integrated temperature-controlled rack (ambient to ~15 °C recommended) |
| Pulse Mode | Adjustable on/off duty cycle |
| Protection Features | Overtemperature, overload, and system self-diagnosis |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-24TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 100 µL – 5 mL |
| Parallel Processing Capacity | 24 samples |
| Cooling Method | Integrated Temperature-Controlled Rack (External Chiller Interface Supported) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Programmable Protocols | Up to 20 user-defined methods |
| Safety Features | Overtemperature & Overload Protection, Real-time System Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-48TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Maximum Ultrasonic Power | 2400 W |
| Sample Volume per Tube | 100 µL – 4 mL |
| Parallel Processing Capacity | 48 Samples |
| Temperature Control | Not Specified (External Cooling Required) |
| Pulse Mode | Adjustable Continuous or Duty-Cycle Mode |
| Programmable Protocols | Up to 20 User-Defined Methods |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 1–20 mL |
| Number of Simultaneous Samples | 4 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Onboard Memory for Up to 20 User-Defined Protocols |
| Safety Features | Real-time Overtemperature & Overload Detection, Auto-Shutdown, Fault Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 5–650 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 µL–500 mL |
| Multi-sample Processing Capability | Yes |
| Safety Features | Overtemperature, overload, and time-out alarms |
| Control Interface | Remote network connectivity (Ethernet/RS232) |
| Design | Stackable benchtop configuration with transparent front access panel and internal LED illumination |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650J |
| Design | Integrated Benchtop System |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (duty cycle programmable) |
| Safety Features | Overload, overtemperature, and timeout alarms |
| Acoustic Enclosure | Multi-layer acoustic damping panels (STC-rated) |
| Control Interface | Programmable digital controller with remote lift actuation |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650L |
| Cooling | Built-in Refrigeration System |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (with test mode) |
| Safety Protections | Overload, overtemperature, and time-out alarms |
| Horn Material | TC4 Titanium Alloy (Grade 5, ASTM B348) |
| Acoustic Enclosure | Integrated 3D Sound-Dampening Chamber |
| Control | Motorized Vertical Lift with Remote Handheld Controller |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-6TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 1–50 mL |
| Number of Simultaneous Samples | 6 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Embedded Microprocessor |
| Program Storage | Up to 20 User-Defined Protocols |
| Safety Features | Real-Time Overtemperature & Overload Monitoring, Auto-Shutdown, Fault Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-8TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Channels | 8 |
| Cooling Mode | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Control Interface | Touchscreen with Programmable Protocol Storage (20 Presets) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Safety Features | Overtemperature & Overload Protection, Real-Time System Diagnostics |
| Compliance | Designed to Support GLP/GMP-Compliant Workflows (Audit Trail Ready via Optional Software) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 5–950 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & self-adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 µL–600 mL |
| Multi-sample Processing Capability | Yes |
| Safety Features | Overtemperature, overload, and time-out alarms |
| Control Interface | Remote network control (RS485/Ethernet) |
| Mechanical Design | Motorized vertical lift stage |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-96TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Well | 100 µL – 0.5 mL |
| Parallel Processing Capacity | 96 samples |
| Cooling Method | Integrated Peltier-based temperature control (operating range: 0–40 °C, programmable) |
| Pulse Mode | Adjustable on/off duty cycle (continuous or pulsed) |
| Power Regulation | 1–100% stepless digital control |
| Data Logging | Timestamped operation records with parameter traceability |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SCIENTZ-CFS |
| Quotation | Upon Request |
| Measurement Time Range | 0–999 s (user-configurable) |
| Turbidity Detection Range | 0.00–6.00 McFarland (MCF) |
| Sample Volume | 1.5–4 mL |
| Throughput | 6 samples per run |
| Detectable Cell Size Range | 1.5–4 µm |
| Step Resolution | 0.01 MCF |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Scientz-IID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–1000 W |
| Sample Volume Capacity | 100 μL to 600 mL |
| Sample Throughput | Single-sample processing per cycle |
| Transducer Material | Titanium Alloy |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ-JMSQ |
| Temperature Range | Ambient to 30 °C |
| Vessel Capacity | 5 × 500 mL |
| Number of Culture Vessels | 5 |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ03-II |
| Pricing | Available Upon Request |
| UV Wavelength | 254 nm |
| Optional Blue Light Source | 470 nm (for gel visualization) |
| Active Irradiation Area | 880 cm² |
| Dose Control | Microprocessor-regulated energy mode (J/cm²) and time mode |
| Safety Features | Interlocked safety door with UV-blocking viewing window |
| Operation Interface | LED display with auto-memory function |
| Design | Drawer-type sample chamber |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | SCINETZ-08 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 2400 W |
| Operating Frequency | 15 kHz |
| Batch Sample Volume | 1–5 L per cycle |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 T |
| Spatial Resolution | ≤ 235 µm (isotropic) |
| Scan Time | As low as 8–9 min per sequence |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded, Zero Stray Field |
| Regulatory Compliance | CE Marked, Designed for GLP-Compliant Preclinical Research |
| Application Focus | Mouse Phenotyping, Longitudinal In Vivo Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Field Homogeneity | <10 ppm over 20 mm DSV |
| Gradient Strength | ≥200 mT/m |
| Gradient Slew Rate | ≥1000 T/m/s |
| Spatial Resolution | ≤200 µm isotropic (typical in vivo mouse brain) |
| Scan Time | <10 minutes per standard sequence |
| Cooling | Passive (no cryogens or chiller required) |
| Shielding | Self-shielded, zero fringe field beyond instrument footprint |
| Regulatory Compliance | CE Marked, IEC 61000-6-3/6-4, ISO 13485–certified manufacturing processes |
| Software Platform | Aspect ImageSuite v5.x (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3-mice |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Spatial Resolution | ≤ 235 µm (isotropic, typical in vivo) |
| Scan Time | As low as 8–9 minutes per sequence (T1- or T2-weighted) |
| Cooling | Passive (no cryogens or chillers required) |
| Shielding | Self-shielded, zero fringe field beyond system footprint |
| Compliance | Designed for ISO 13485-aligned manufacturing and GLP-compliant preclinical research environments |
| Software Platform | Aspect ImageSuite™ v5.x (FDA 21 CFR Part 11–ready audit trail, DICOM 3.0 export, multi-sequence reconstruction pipeline) |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5 |
| Instrument Type | Nuclear Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Weight Capacity | Up to 700 g (mouse/rat) |
| Imaging Modes | 2D/3D, In Vivo, Ex Vivo, In Vitro |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded (Zero Stray Field) |
| Typical Resolution | ≤ 234 µm (T2-weighted), ≤ 195 µm (T1-weighted) |
| Acquisition Time | ~4.8–9.1 min per scan |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5-Rat |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Spatial Resolution | ≤100 µm (in-plane, 3D gradient-echo mode) |
| Imaging Modes | T1-weighted, T2-weighted, PD-weighted, 2D/3D spin-echo and gradient-echo sequences |
| Application Focus | In vivo rodent musculoskeletal phenotyping, arthritis progression monitoring, preclinical OA model validation |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | NM21-040H-I |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| RF Coil Inner Diameter | 40 mm |
| Field of View (FOV) | 60 × 60 mm² |
| Maximum Sample Capacity | 1 animal per scan |
| Energy Resolution | Not applicable (N/A) |
| Spatial Resolution | Not specified in source |
| Scan Speed | Not quantified (system supports multi-sequence acquisition with variable TR/TE) |
| Compliance | Designed for preclinical GLP-compliant research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T |
| Minimum Slice Thickness | 0.8 mm |
| Animal Weight Capacity | 1–45 g |
| Sample Diameter Limit | < 40 mm |
| Minimum Sample Volume | ≥ 100 µL |
| Scan Orientation | Arbitrary Angle & Arbitrary Plane |
| Compliance | Designed for Preclinical GLP-Compatible Workflow |
| Optional Modules | Gas Anesthesia System, ROI Analysis Software Suite |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42 |
| Instrument Type | 1.0 Tesla Permanent-Magnet Benchtop MRI System |
| Animal Weight Range | 1–45 g |
| Maximum Sample Width | < 40 mm |
| Minimum Sample Volume | ≥ 100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Field Homogeneity | Optimized for high SNR and spatial resolution |
| Anesthesia Compatibility | Optional integrated gas anesthesia module |
| Shielding Requirement | None — no RF-shielded room required |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-NIUMAG |
| Instrument Type | Permanent-Magnet Small Animal Magnetic Resonance Imaging System |
| Magnetic Field Strength | ~1.0 T (Permanent Magnet) |
| Bore Diameter | ≥40 mm |
| Maximum Sample Weight | 45 g |
| Minimum Sample Volume | ≥100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Imaging Modes | T1-, T2-, PD-weighted, Gradient Echo, Spin Echo, Multi-slice 2D/3D acquisitions |
| Anesthesia Compatibility | Optional Integrated Gas Anesthesia System |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail (optional configuration), GLP/GMP-compatible data logging |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42- |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Magnetic Field Strength | 1.0 T |
| Gradient Performance | Standard for Small Animal Imaging |
| Minimum Slice Thickness | 0.8 mm |
| Animal Weight Capacity | 1–45 g |
| Sample Chamber Diameter | ≤40 mm |
| Minimum Sample Volume | ≥100 µL |
| Imaging Modality | Proton (¹H) MRI |
| Safety | Non-ionizing, Non-invasive, No Radiation Exposure |
| Regulatory Compliance | Designed per ISO 13485-aligned manufacturing practices |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | NM42-0 |
| Field Strength | 1.0 T Permanent Magnet |
| Maximum Sample Width | <40 mm |
| Animal Weight Range | 1–45 g |
| Minimum Sample Volume | ≥100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Imaging Modality | Nuclear Magnetic Resonance (NMR)-based Magnetic Resonance Imaging (MRI) |
| Regulatory Classification | Preclinical In Vivo Imaging System |
| Compliance Framework | Designed for GLP-compliant preclinical research environments |
| Software | Integrated MRI acquisition platform with optional advanced image processing module |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-040H-I |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Magnetic Field Strength | 1.0 ± 0.08 T |
| Magnet Type | Permanent Magnet |
| Field Homogeneity | ≤20 ppm over Ø40 mm × H40 mm DSV |
| Imaging FOV | Ø40 mm × 40 mm (height) |
| Minimum Slice Thickness | 0.8 mm |
| Spatial Resolution (in-plane) | 0.08 mm |
| Gradient System | High-Performance Integrated Gradient Set |
| RF Coil Configuration | Animal-Specific Tunable RF Coils |