Life Science Instruments
Filter
Showing 5011–5040 of 7558 results
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LSHZ-300D |
| Price | USD 2,650 (approx.) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SHZ-88A Reciprocating Water Bath Incubator Shaker |
| Quotation | USD 1,180 (FOB Jiangsu) |
| Instrument Type | Water Bath Incubator Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm |
| Oscillation Amplitude | 26 mm |
| Temperature Range | Ambient Water Temp to 98 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Platform Quantity | 1 |
| Max Capacity | 9 × 250 mL flasks |
| Power Rating | 1200 W |
| Dimensions (W×D×H) | 680 × 430 × 410 mm |
| Net Weight | 30 kg |
| Power Supply | 220 V, 50 Hz |
| Control System | Microprocessor-Based Intelligent PID Temperature Controller |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor (Beijing HQ) |
| Origin Category | Domestic (PRC) |
| Model | THZ-22(82) |
| Instrument Type | Orbital Shaker |
| Timer Range | None |
| Oscillation Frequency | 40–300 rpm, stepless adjustment, auto-hold function, digital display, accuracy ±5 rpm |
| Temperature Control Range | Ambient +5°C to 60°C |
| Platform Quantity | 1 |
| Capacity | 12 × 250 mL flasks |
| Heating Power | 250 W (heater), 300 W (total system) |
| Noise Level | ≤50 dB(A) at 1 m distance when operating at 240 rpm |
| Dimensions (W×D×H) | 680 × 400 × 480 mm |
| Net Weight | 42 kg |
| Power Supply | 220 V AC, 3 A, single-phase |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | THZ-C Temperature-Controlled Orbital Shaker |
| Quotation | USD 980 (FOB Jiangsu) |
| Instrument Category | General-Purpose Laboratory Orbital Shaker |
| Timing Range | None (Manual Operation Only) |
| Oscillation Frequency | 40–300 rpm, Continuously Adjustable with Digital Display and Memory Retention |
| Oscillation Amplitude | 25 mm (Standard Orbital Motion) |
| Temperature Control Range | Ambient +5°C to 60°C (Digital PID Controller, ±0.3°C Stability at 37°C) |
| Platform Quantity | Single Deck |
| Maximum Load Capacity | 6 × 1000 mL Erlenmeyer Flasks (Configurable with Universal Clamps or Tube Holders) |
| Noise Level | <50 dB(A) at 1 m Distance (Measured at 300 rpm, No Load) |
| Interior Illumination | Integrated White LED Lighting (Switchable, Non-UV, for Visual Monitoring) |
| Dimensions (W×D×H) | 500 × 610 × 490 mm |
| Total Power Consumption | 300 W (Heating Element: 250 W |
| Motor & Control Circuitry | 50 W) |
| Electrical Supply | 220 V AC, 50 Hz, Single-Phase |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | THZ-C-L |
| Instrument Category | Refrigerated Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 5–60 °C (at ambient 25 °C) |
| Platform Quantity | 1 |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Power Consumption | 600 W |
| Dimensions (W×D×H) | 800 × 590 × 500 mm |
| Net Weight | 56 kg |
| Power Supply | 220 V, 50 Hz |
| Oscillation Frequency | 50–300 rpm |
|---|---|
| Amplitude | 26 mm |
| Temperature Range | Ambient +3°C to 60°C |
| Display | LED |
| Max Capacity | 15 × 250 mL or 6 × 1000 mL flasks |
| Standard Fixture | Universal clamp |
| Power Supply | 200–240 V AC, 50 Hz |
| Dimensions (W×D×H) | 680 × 500 × 480 mm |
| Origin | Jiangsu, China |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | THZ-D |
| Price | USD 1,200 (FOB Jiangsu) |
| Brand | QIAGEN |
|---|---|
| Origin | Germany |
| Model | QIAstat-Dx® |
| Configuration | Integrated Sample-to-Answer Platform with Modular Analyzer Units |
| Cartridge Format | Closed, Single-Use Microfluidic Cartridge |
| Maximum Multiplexing Capacity | 48 Targets per Run |
| Turnaround Time | 30–80 minutes |
| Sample Input Flexibility | Direct swab loading |
| Scalability | Up to 4 Independent Analyzer Modules per System |
| Regulatory Status | CE-IVD marked |
| Brand | Qigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-0248D |
| Standard Compliance | SH/T 0248 |
| Test Channels | Dual-position |
| Detection Method | Infrared Fiber-Optic Sensor |
| Cooling System | Compressor-Based Refrigeration |
| Bath Temperature Range | –70 °C to +80 °C |
| Display & Control | 7-inch Industrial Touchscreen + PLC Controller |
| Sample Tube | CFPP-Specific ASTM/SH-Compliant Tube |
| Filtration System | Vacuum-Assisted Suction per SH/T 0248 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1500 W |
| Operating Ambient | 10–30 °C, ≤85% RH |
| Data Export | USB Flash Drive |
| Temperature Sensor Accuracy | ±0.1 °C (typical for industrial Pt100 RTD) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HYL-C Dual-Layer Multifunctional Incubator Shaker |
| Price | USD 7,000 (approx.) |
| Instrument Category | General-Purpose Orbital/Reciprocal Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Amplitude Options | 26 mm, 35 mm, or 50 mm (user-selectable per layer) |
| Temperature Control Range | 5–60 °C (ambient 20 °C) |
| Number of Shaking Platforms | 2 |
| Power Supply | 220 V, 50 Hz |
| Total Power Consumption | 3000 W |
| Dimensions (W×D×H) | 1100 × 750 × 1800 mm |
| Platform Capacity | 15 × 1000 mL flasks per layer |
| Construction | Interior—polished stainless steel (mirror-finish) |
| Door Configuration | Dual front-access doors with internal LED illumination |
| Operational Mode | Stackable modular design—layers operate independently with separate temperature and speed control |
| Brand | QNET |
|---|---|
| Model | ATS Gen4+ |
| Type | Fully Automated |
| Sorting Speed | 10 cells/sec |
| Total Sortable Cells | 10,000 |
| Sample Throughput | 0–10 samples |
| Processing Time | 30 minutes |
| Detection | High-Resolution CMOS Imaging with Real-Time Droplet Monitoring |
| Collection Formats | Microscope Slides, 96-well, 384-well, 1536-well, or Custom Microwell Plates |
| Actuation Principle | Contactless Acoustic Droplet Ejection (ADE) |
| Dead Volume | <1 µL per transfer |
| Integration Ready | Yes (Lab Automation Bus, RS-232, Ethernet) |
| Brand | QSense |
|---|---|
| Origin | Sweden |
| Model | QSensors |
| Instrument Type | Microfluidic Chip System |
| Chip Surface Types | 18 Standard Coatings (e.g., Au, SiO₂, TiO₂, Al₂O₃, Cr, Ni, PMMA, PEI, NHS, Biotin, Hydroxyapatite, etc.) |
| Manufacturing Site | Gothenburg, Sweden |
| Compliance | Designed for ISO/IEC 17025-aligned QCM-D workflows |
| Application Domain | Surface science, biomolecular interaction analysis, electrochemistry, environmental interfaces, energy materials, and pharmaceutical formulation studies |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q125 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 125 W |
| Operating Frequency | 20 kHz |
| Adjustable Pulse Duration | 1 s – 60 s |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 20.3 × 35 × 14.6 cm |
| Standard Probe | 1/8" (3.2 mm) tapered microtip |
| Optional Accessories | Non-contact cup horn (Cat. #4608), 8-position probe holder (Cat. #4602), Acoustic Enclosure (Cat. #432A) |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q125 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 125 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 100 mL |
| Number of Samples per Run | 1 |
| Pulse Duration Adjustment | 1 s – 60 s |
| Continuous Operation Limit | Up to 10 hours |
| Dimensions (W×D×H) | 20 × 35 × 15 cm |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q2000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 2000 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 0–120 °C |
| Maximum Batch Sample Volume | 5 L |
| Flow-Through Capability | Yes (with Flocell chamber) |
| Amplitude Adjustment Range | 20–100% |
| Pulse Mode | Adjustable (1 s–1 min on/off cycles) |
| Continuous Operation Time | 1 s–10 hr |
| Dimensions (H × W × D) | 178 × 380 × 463 mm |
| Standard Probe | 4677 (1/2″ diameter) |
| Optional High-Capacity Probe | 4777 (1.5″ / 38 mm diameter, 25.4 cm length, 100 µm amplitude) |
| Flow Cell | Flocell with 1/2″ NPT ports, optional water-jacketed cooling and acoustic enclosure |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 500 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 1000 mL (batch) / 0.5–20 L/min (flow-through) |
| Throughput | 1–384 samples per run |
| Pulse Duration Adjustment | 1 s – 1 min |
| Continuous Operation Limit | 10 hr |
| Probe Amplitude Range | 30–320 µm (model-dependent) |
| Standard Probe Diameter Options | 1.6 mm, 3.2 mm, 6.4 mm, 12.7 mm, 19.1 mm, 25.4 mm |
| Probe Types | Replaceable-tip, Solid-tapered, High-amplitude, Flow-through, and Cup-horn configurations |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 500 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–1000 mL (up to 0.5 L/min with flow cell) |
| Dimensions (W × D × H) | 20.3 × 38.7 × 22 cm |
| Continuous Operation Time | Up to 10 hr |
| Adjustable Pulse Duration | 1 s – 1 min |
| Amplitude Range | 20–100% (120 µm nominal at 1/2″ probe) |
| Display | Digital real-time readout of time, power, and energy |
| Safety | Integrated overload protection |
| Remote Control | Footswitch-compatible |
| Standard Kit | Host unit, transducer, 1/2″ tapered probe (part #4220), wrench set |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q55 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 55 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 20.3 × 19.0 × 14.6 cm |
| Standard Probe | 1/8" (3.2 mm) tapered microtip |
| Optional Probes | 4423 (0.2–5 mL, 2 mm, 200 µm amplitude), 4422 (0.5–15 mL, 3.2 mm, 180 µm), 4435 (5–50 mL, 6.4 mm, 120 µm) |
| Optional Accessory | 432A Acoustic Enclosure (50.8 × 30.5 × 30.5 cm) |
| Brand | Qsonica LLC |
|---|---|
| Country of Origin | USA |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 700 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 1000 L (via flow cell or microtip) |
| Throughput | 1–384 samples per run |
| Compliance | UL, CE, CSA, RoHS |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 700 W |
| Operating Frequency | 20 kHz |
| Temperature Control | Automatic frequency tuning with overtemperature and overload protection |
| Sample Volume Capacity | 0.1 mL to 1 L (batch mode) |
| Sample Throughput | Single sample per cycle |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 700 W |
| Operating Frequency | 20 kHz |
| Temperature Monitoring Range | 0–100 °C (with optional probe) |
| Sample Volume Capacity | 0.1 mL–1 L (batch) |
| Dimensions (W×D×H) | 20 × 39 × 22 cm |
| Maximum Continuous Operation Time | 72 hr |
| Pulse Duration Range | 1 s–24 hr |
| Probe Amplitude Range | 0–99.99% (digitally controlled) |
| Compliance | UL, CE, CSA, RoHS |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 700 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–1000 mL (batch) |
| Dimensions (W × D × H) | 20.3 × 38.7 × 22 cm |
| Programmable Memory Slots | 10 |
| Continuous Operation Time | Up to 72 hr |
| Pulse Duration Range | 1 s – 24 hr |
| Display | Full-color capacitive touchscreen |
| Temperature Monitoring | Real-time probe temperature sensing with thermal protection |
| Amplitude Control Range | 0–100% (digitally regulated, probe-specific calibration) |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q800R3 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 750 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 2–45 °C |
| Sample Volume per Tube | < 50 µL |
| Maximum Sample Capacity | 36 tubes |
| Compatible Adapters | 8 × 1.5 mL, 12 × 0.5 mL, 18 × 0.2 mL |
| Brand | Quanterix |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SR-X |
| Price Range | USD 250,000–350,000 (FOB) |
| Sample Types | Serum, Plasma, Cerebrospinal Fluid (CSF), Tear, Urine, and Other Biological Fluids |
| Sample Volume | 1–100 µL |
| Dynamic Detection Range | <1 fg/mL to >100 pg/mL |
| Sensitivity | Sub-femtogram per mL (fg/mL) |
| Assay Time | ≥45 minutes |
| Multiplex Capability | Up to 4-plex (simultaneous analyte detection) |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | Q10001 |
| Detection Time | 30 s |
| Cell Concentration Range | 2 × 10⁵ to 1 × 10⁹ cells/mL |
| Sample Loading Volume | 5–6 µL |
| Measured Volume per Analysis | 0.09 µL (across 10 fields of view) |
| Detectable Cell Size Range | 0.3–50 µm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QuantStudio 1 Plus Real-Time PCR System |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Reaction Volume | 10–100 µL |
| Excitation/Emission Filter Channels | FAM, VIC, ROX, Cy5 |
| Dye Compatibility | FAM/SYBR Green I/SYTO 9 |
| Detection Sensitivity | Discrimination of ≤1.5-fold differences in target quantity |
| Dimensions (H×W×D) | 40 × 27 × 50 cm |
| Weight | <26 kg |
| Display | 8.5-inch capacitive touchscreen |
| Thermal Block | Fixed 96-well, 0.2 mL format with manual drawer |
| Cloud Integration | Thermo Fisher Connect™ platform |
| Software Options | Web-based QuantStudio Design and Analysis Cloud Software (browser-accessible, no local installation) |
| Brand | Qubit |
|---|---|
| Origin | Canada |
| Model | Q-Box CO650 |
| CO₂ Analyzer Principle | Non-Dispersive Infrared (NDIR) |
| Gas Flow Mode | Open-flow, Closed-chamber Configuration |
| Flow Rate | 650 mL/min |
| CO₂ Measurement Range (Display) | 0–1999 ppm |
| CO₂ Accuracy | ±1 ppm (after calibration) |
| CO₂ Repeatability | ±1 ppm (under stable T/P) |
| Response Time (t₉₅) | ~25 s (at 250 mL/min) |
| Warm-up Time | ~5 min (at 22°C) |
| PAR Output | Up to 1200 µmol·m⁻²·s⁻¹ (white LED, leaf surface) |
| Leaf Chamber Volume | 9 mL |
| Chamber Dimensions | 3.0 × 5.3 × 25.5 cm (H×W×L) |
| Data Logger | 3 analog + 2 digital inputs, USB 2.0, 100 kS/s sampling rate |
| Operating Temp | 0–50°C |
| Storage Temp | −40–+70°C |
| Humidity Range | 5–90% RH (non-condensing) |
| Power | 12 V DC or 120 V AC/60 Hz adapter |
| Weight (Analyzer Unit) | 1.0 kg |
| Weight (Pump Unit) | 0.9 kg |
| Warranty | 1 year |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8-Arm Maze |
| Pricing | Available Upon Request |
| Brand | RADOBIO |
|---|---|
| Model | AirSafe 1300A2 |
| Safety Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1300 × 810 × 2290 mm |
| Internal Dimensions (L×W×H) | 1180 × 580 × 798 mm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | <65 dB(A) |
| Vibration at Work Surface Center | ≤5 µm |
| Lighting Illuminance | ≥900 lx |
| UV Lamp | 30 W × 1 |
| Fluorescent Lamp | 18 W × 1 |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power (excl. outlet) | 0.33 kW |
| Max. Power (incl. outlet) | 1.65 kW |
| Net Weight | 268 kg |
| Compliance | YY 0569–2011, GB 4793.1, GB/T 18268.1 |
| Air Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | AirSafe 1500A2 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1500×810×2290 mm |
| Internal Dimensions (L×W×H) | 1380×580×798 mm |
| Filter Efficiency | ≥99.9995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | <65 dB(A) |
| Vibration at Work Surface Center | ≤5 µm |
| Lighting Illuminance | ≥900 lx |
| UV Lamp | 30 W × 1 |
| Fluorescent Lamp | 18 W × 1 |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power (excl. outlet) | 0.33 kW |
| Max. Power (incl. outlet) | 1.65 kW |
| Net Weight | 312 kg |
| Compliance | YY 0569–2011, GB 4793.1, GB/T 18268.1 |
| Air Cleanliness Class | ISO 4 (equivalent to Fed Std 209E Class 10) |
| Personnel Protection | ≤10 CFU/plate (impactor), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-Contamination Protection | ≤2 CFU/plate |
| Filter Type | ULPA (Ultra-Low Penetration Air) |