Life Science Instruments
Filter
Showing 4951–4980 of 7558 results
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam FC 00-C/1010GFP |
| Imaging Area | 13 × 13 cm uniform LED illumination |
| Camera Resolution | 1392 × 1040 pixels (optional: 640 × 480 or 512 × 512) |
| Temporal Resolution | up to 1 µs for fast fluorescence induction kinetics |
| Filter Wheel | motorized 8-position |
| Excitation Wavelengths | 384 nm (BFP), 395–397 nm (wtGFP), 488 nm (EGFP), customizable LED arrays |
| Emission Detection | configurable bandpass filters (e.g., 469/35 nm, 532/28 nm) |
| Software | FluorCam v7.x with automated dark adaptation, ROI-based kinetics, GLP-compliant audit trail, Excel export, barcode support |
| Compliance | Compatible with ASTM E2595-22 (fluorescence imaging standards), supports 21 CFR Part 11–compliant user access control and data integrity workflows |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Plant Chlorophyll Fluorescence and Multispectral Imaging Platform |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Excitation Wavelengths | 320–400 nm (UV-A), 450 nm (blue), 620 nm (red), white light, 735 nm (NIR) |
| Filter Wheel | 7-position motorized |
| Adjustable Imaging Height | 350–1350 mm |
| Compliance | ASTM E2912, ISO 17025-compatible workflow support, GLP/GMP-ready data audit trail (via software timestamping and protocol versioning) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Large-Scale Version |
| Imaging Area | 35 × 35 cm |
| CCD Resolution | 1360 × 1024 pixels |
| Frame Rate | up to 20 fps at full resolution |
| A/D Depth | 16-bit (65,536 gray levels) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Adjustable Platform Height | 350–1350 mm |
| Excitation Sources | 620 nm red, dual-color (620 nm + cool white), optional blue/UV/IR LEDs |
| Filter Wheel | 7-position motorized |
| Standard Fluorescence Parameters | >50 chlorophyll fluorescence parameters (e.g., Fv/Fm, ΦPSII, NPQ, qP, Rfd) |
| Optional Modules | UV-induced multispectral fluorescence (F440, F520, F690, F740), GFP/YFP imaging, PAR absorption & NDVI imaging, IR thermography (640 × 512, -25 to +150 °C, 30 mK sensitivity) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Area | 35 × 35 cm |
| Adjustable Height Range | 20–150 cm |
| CCD Sensor | 2/3″, 1392 × 1040 pixels (15 fps), pixel size 6.45 µm |
| Excitation Sources | Orange, white & NIR LEDs (72 × 72 cm panel, 3 × 64 LEDs) |
| Actinic Lights | Dual-color, 350 & 550 µmol photons·m⁻²·s⁻¹ |
| Saturation Pulse | Up to 3500 µmol photons·m⁻²·s⁻¹ |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, NPQ, QY, Rfd, qP, qN, ΦPSII, etc. |
| Data Acquisition | Time-stamped automated protocols, USB 2.0 (480 Mbit/s) |
| Power Supply | 380 V three-phase AC or optional DC generator unit |
| IP Rating | Optional waterproof housing for field use |
| Dimensions | 192 × 125 × 100 cm (H × W × D) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Mobile |
| Imaging Sensor | 1392×1040 CCD, 20 fps, 6.45 µm pixel size |
| Excitation Sources | 4+1 configurable LED array (red, cool white, UV 320–400 nm), optional blue/green/cyan/FAR LEDs |
| Filter Wheel | 7-position motorized, with Chl-F, MCF, GFP/YFP, F440/F520/F690/F740 filters |
| Fluorescence Parameters | >60 quantitative metrics including Fo, Fm, Fv/Fm, NPQ, QY, PARabs, Rfd, BGF, UV-Chl-F ratios |
| NDVI & PAR Absorption | Optional dual-wavelength (630/735 nm) LED module |
| Thermal Imaging (optional) | Uncooled VOx microbolometer, 640×512 pixels, 7.5–13.5 µm, -25 to 150 °C, sensitivity ≤30 mK @ 30 °C |
| RGB Imaging (optional) | 2592×1944 scientific-grade CMOS, 54 dB SNR, 1–40× zoom |
| Power Supply | 90–240 V AC |
| Compliance | CE-marked, ISO/IEC 17025-compatible data acquisition architecture, FDA 21 CFR Part 11-ready software audit trail (with optional configuration) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Open-Field Multispectral Fluorescence Imaging System |
| Imaging Area | 13 × 13 cm (Standard), 20 × 20 cm (Large Format) |
| CCD Resolution | 1392 × 1040 pixels, Pixel Size: 6.45 µm |
| Excitation Wavelengths | UV (320–400 nm), Blue (450 nm), Red (618 nm), Far-Red (735 nm), Green (530 nm), Cyan (490 nm) |
| Emission Detection Bands | F440, F520, F690, F740, GFP (509 nm), YFP (527 nm), Chl-F, BGF, PARabs, NDVI |
| Actinic Light Intensity | Up to 3000 µmol·m⁻²·s⁻¹ (configurable) |
| Saturation Flash | Up to 6000 µmol·m⁻²·s⁻¹ |
| Measurement Pulse Duration | 10–100 µs |
| Filter Wheel | 7-position motorized |
| Software | FluorCam v8.x with GLP-compliant audit trail, protocol editor, ROI-based quantification, dual averaging modes (signal-then-average / average-then-signal), time-stamped automated acquisition |
| Compliance | Designed for ISO/IEC 17025-aligned labs |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Portable |
| Imaging Area | 40 mm × 40 mm |
| Sensor | TOMI-2 CCD, 1360 × 1024 pixels, 16-bit A/D, 20 fps @ full resolution |
| Excitation Light | 610–620 nm (measuring light), 5300 K white light (actinic & saturating light, up to 4500 µmol photons/m²·s), 710–740 nm far-red LEDs (for Fo′ determination) |
| Spectral Detection Range | 400–1000 nm |
| Weight | 2 kg |
| Dimensions | 194 × 182 × 280 mm |
| Power Supply | AC 100–240 V or optional field battery pack (≥10 h operation) |
| Operating Conditions | 5–40 °C, 0–90% RH (non-condensing) |
| Compliance | CE, RoHS, firmware-upgradable BIOS |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Portable |
| CO₂ Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Air Pump Flow | 100–500 mL/min |
| CO₂ Control | up to 2000 ppm |
| PAR Control | RGB LED up to 2400 µmol·m⁻²·s⁻¹, White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Battery Life | up to 16 h (12 V / 7.5 Ah Li-ion) |
| Imaging Sensor | TOMI-2 CCD, 1360×1024 pixels, 16-bit A/D, 20 fps max |
| Imaging Area | 35×46 mm |
| Excitation Wavelengths | 620 nm (measuring light), 455/620/white (saturating & actinic light), 735 nm (far-red) |
| Spectral Response | 400–1000 nm |
| Quantum Efficiency | 70% at 540 nm |
| Read Noise | <12 e⁻ RMS |
| Full Well Capacity | >70,000 e⁻ (unbinned) |
| Data Interface | Gigabit Ethernet, Mini-B USB, RS232 |
| Display | 480×272 pixel WQVGA touchscreen |
| Storage | SD card (up to 32 GB) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-96 |
| Measurement Principle | Dual-modality chlorophyll fluorescence imaging + fiber-optic dissolved oxygen sensing |
| Throughput | 96 parallel samples |
| Fluorescence Parameters | >50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln |
| Oxygen Measurement | Fiber-optic sensor, ±0.1% O₂ @ 1% O₂, 0.01% O₂ resolution, 10–20 Hz sampling rate |
| Chamber Material | Sterilizable transparent polystyrene |
| Dimensions (O₂ module) | 162 × 102 × 32 mm |
| Weight (O₂ module) | 670 g |
| Temperature Sensor | 0–50 °C, ±0.5 °C accuracy, 0.012 °C resolution |
| Pressure Sensor | 300–1100 mbar, ±6 mbar accuracy, 0.11 mbar resolution |
| Software | FluorCam v7.x with GLP-compliant audit trail, protocol editor, ROI-based kinetic analysis, signal averaging mode for low-biomass samples |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam-MultiSpectral Modular Plant Phenotyping Imaging System |
| Thermal Imager | Uncooled VOx microbolometer, 640×512 px, 7.5–13.5 µm, −25 to +150 °C, NETD ≤ 0.03 °C @ 30 °C |
| Fluorescence Imaging | UV/Blue/Red excitation, F440/F520/F690/F740 detection, 1360×1024 CCD, 20 fps |
| RGB Imaging | 2592×1944 sensor, 1–40× zoom, FOV 6.1×7.9 mm (40×) to 20.8×25.4 mm |
| NDVI/PAR Module | 630 nm & 740 nm LEDs |
| Max Sample Height | 50 cm |
| Compliance | CE-marked, ISO/IEC 17025 traceable calibration documentation available |
| Software | FluorCam v7.x with GLP-compliant audit trail, FDA 21 CFR Part 11 optional modules |
| Brand | PSI (Photosynthesis Systems Instruments, Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorPen FP110 |
| Measurement Principle | Pulse-Amplitude-Modulated (PAM) chlorophyll fluorescence kinetics |
| Light Source | 470 nm blue LED (wavelength-selectable option available) |
| Detection | PIN photodiode with 667–750 nm bandpass filter |
| Time Resolution | 10 µs (100,000 measurements/s) |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, qP, Rfd, PI_ABS, ABS/RC, TR₀/RC, ETo/RC, DI₀/RC, Mo, Area, Sm, OJIP-derived 26 parameters |
| Excitation Intensities | Measuring light (0.09–0.9 µmol photons·m⁻²·s⁻¹), Actinic light (10–1000 µmol photons·m⁻²·s⁻¹), Saturating pulse (up to 3000 µmol photons·m⁻²·s⁻¹) |
| PAR Sensor (optional) | 400–700 nm, cosine-corrected, ±5% accuracy, output in µmol photons·m⁻²·s⁻¹ |
| Sample Interface | Interchangeable leaf clips (FP110/S fixed, FP110/D split, FP110/P fiber-optic probe, FP110/X custom) |
| Data Storage | 16 MB flash memory (~149,000 data points) |
| Display | Graphical LCD, dual-button interface |
| Power | Rechargeable Li-ion battery, 48 h continuous operation, USB charging |
| Environmental Rating | 0–55 °C, 0–95% RH (non-condensing) |
| Connectivity | Integrated Bluetooth 4.0 + USB 2.0 + GPS module |
| Software | FluorPen 1.1 (Windows 7+), supports data download, kinetic curve visualization, Excel export, remote instrument control, and GLP-compliant audit trail generation |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FS Series (FS130, FS360, FS-RI, LED Benchtop) |
| Temperature Range | 0–40°C (configurable to 7–55°C with optional upgrade) |
| Light Source | Cool White + IR (optional RGB + IR quad-channel) |
| Photosynthetic Photon Flux Density (PPFD) | 0–1500 µmol·m⁻²·s⁻¹ (model-dependent) |
| Humidity Control | 40–80% RH (FS-RI only) |
| Air Exchange Rate | 250–1200 L/hr |
| Touch Interface | 10.5-inch capacitive touchscreen (FS-RI) |
| Compliance | Designed for GLP-compliant plant phenotyping and circadian biology research |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-A2/A3/B2/B3/C/MULTI Series |
| Light Source Type | Programmable Multi-Spectral LED Array |
| Active Area Options | 27 × 81 cm or 27 × 41 cm |
| Spectral Channels | Cool White (5000–6500 K), Deep Red (660 nm), Far-Red (735 nm), plus optional Blue (450 nm), Green (530 nm), IR (850 nm) |
| Photon Flux Density | Up to 1600 µmol(photon)·m⁻²·s⁻¹ (at 50 cm, MULTI configuration) |
| Intensity Control Range | 0–100% in 0.1% increments |
| Uniformity | ±5% across active area (measured per ASTM E2917-20) |
| LED Lifetime | 60,000–70,000 h at rated output |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | RS-485, USB, Ethernet (Light Studio v4.85) |
| Compliance | CE, RoHS, IEC 61000-6-3 (EMI), IEC 61000-6-2 (Immunity) |
| Software Features | Predefined diurnal cycles, cloud simulation, pulse modulation (µs–h), multi-channel spectral blending, GLP-compliant audit trail (optional) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fyto-Panel |
| Dimensions | 27 × 81 cm or 27 × 41 cm |
| Maximum Photosynthetic Photon Flux Density (PPFD) | 2400 µmol·m⁻²·s⁻¹ at 50 cm |
| Spectral Channels | Cool White + Far-Red + Deep Red (standard) |
| LED Lifetime | 60,000–70,000 h |
| Power Consumption | 210 W (A), 360 W (B), 580 W (C), 600 W (MULTI) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Control Interface | USB/RS-485 |
| Software Features | Programmable light regimes (duration, intensity, spectral composition, modulation waveforms), cloud cover simulation, dawn/dusk transition modeling, GLP-compliant audit trail (via Light Studio Pro) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FytoScope |
| External Dimensions | 8.6 × 4.3 × 2.78 m (L×W×H) |
| Internal Dimensions | 8.00 × 3.50 × 2.20 m |
| Growing Area | 18 m² |
| Corridor Width | 75 cm |
| Temperature Range | 10–40 °C (±0.2 °C stability) |
| Humidity Range | 40–80 % RH |
| CO₂ Control (optional) | 250–5000 ppm (±2 % accuracy) |
| Light Intensity | 0–1000 µmol/m²/s at 50 cm |
| Spectral Channels | Tunable white + far-red LED arrays |
| Independent Zoning | 4 controllable growth zones |
| Air Filtration | EN779 G4 + G7 dual-stage |
| Thermal Insulation | Polyurethane foam, λ = 0.025 W/m·K |
| Control Interface | Integrated touchscreen + Fytotron software suite (server/client architecture) |
| Data Export | USB, LAN, real-time charting & audit-trail logging |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FytoScope FS160 / FS300 |
| Internal Volume | 163 L (FS160) / 307 L (FS300) |
| Temperature Range | 10–45 °C |
| Operating Ambient | 10–35 °C |
| Illumination | White + 735 nm Far-Red LEDs |
| Max Photosynthetic Photon Flux Density (PPFD, at 30 cm) | Top Light — 500 µmol/m²·s (upgradable to 1500 µmol/m²·s) |
| Lighting Layers | FS160 — 2 layers (1 top + 1 bottom) |
| Cultivation Area | 0.38 m² (FS160) / 0.75 m² (FS300) |
| Shelf Dimensions | 48.5 × 38.5 cm |
| Airflow Rate | 450 L/h |
| Refrigerant | R290 (A3 class, non-ozone-depleting) |
| Internal Dimensions (W×D×H) | FS160 — 51 × 45 × 71 cm |
| External Dimensions (W×D×H) | FS160 — 60 × 62 × 114 cm |
| Control Interface | 7″ color capacitive touchscreen |
| Programmable Protocols | Up to 100 user-defined programs with time-resolved control of temperature, spectral composition, and PPFD profiles including diurnal cycles, rapid light fluctuations, and spatial light gradients |
| Data Logging | Real-time acquisition and on-screen visualization of environmental parameters |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | PSI Growth Capsule |
| Temperature Range | –5 to 40 °C (or 10 to 40 °C) |
| Humidity Range | 40–80% RH |
| Light Intensity | 0–1,000 µmol·m⁻²·s⁻¹ (optional up to 1,500 µmol·m⁻²·s⁻¹) |
| Air Exchange Rate | 20 L·min⁻¹·m⁻² |
| Light Source | Multi-channel programmable LED (white, RGB, NIR) |
| Control Interface | 10.5″ color touchscreen LCD |
| Dimensions (dual-unit) | 12.2 m (L) × 2.45 m (W) × 2.9 m (H) |
| Connectivity | LAN-based remote monitoring and data export |
| Compliance | Designed for GLP-compliant environmental simulation and phenotyping workflows |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | LaiPen LP100 |
| Measurement Parameters | Leaf Area Index (LAI), Photosynthetically Active Radiation (PAR) |
| Detector Wavelength Range | 400–700 nm (PAR), 400–500 nm (LAI) |
| Field of View | 112° horizontal, 16° vertical |
| Measurement Angles | 0°, 16°, 32°, 48°, 64° |
| Memory Capacity | 4 MB (>100,000 data points) |
| Display | 2×8 character LCD |
| Battery Life | 48 hours |
| Dimensions | 120 mm × 57 mm × 30 mm |
| Weight | 180 g |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | LaiPen LP110 |
| Measurement Parameters | Leaf Area Index (LAI), Photosynthetically Active Radiation (PAR) |
| Detector Wavelength Range | 400–700 nm (PAR), 400–500 nm (LAI) |
| Field of View | 112° horizontal, 16° vertical |
| Measurement Angles | 0°, 16°, 32°, 48°, 64° |
| Memory Capacity | 16 MB (>100,000 data points) |
| Display | 2×8 character LCD |
| Communication | Bluetooth + USB |
| Battery Life | 48 hours |
| Dimensions | 120 × 57 × 30 mm |
| Weight | 180 g |
| Operating Conditions | 0–55 °C, 0–95% RH (non-condensing) |
| Storage Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Mobile PlantScreen Phenotyping Imaging Platform |
| Category | Import |
| Distribution Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | MP100 |
| Measurement Principle | Pulse-Amplitude-Modulated (PAM) Chlorophyll Fluorescence |
| OJIP Time Resolution | 10 µs (100,000 samples/s) |
| Fluorescence Parameters | >50 including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, Rfd, PAR, PI_ABS, ABS/RC, Mo, Area, Sm |
| Light Sources | Adjustable blue LED (470 nm), optional multi-wavelength LEDs |
| Actinic Light Range | 0–1000 µmol(photon)·m⁻²·s⁻¹ |
| Saturation Pulse Intensity | 0–3000 µmol(photon)·m⁻²·s⁻¹ |
| Measuring Light Intensity | 0–0.09 µmol(photon)·m⁻²·s⁻¹ |
| PAR Sensor | Cosine-corrected, 400–700 nm, ±5% accuracy, output in µmol(photon)·m⁻²·s⁻¹ |
| Memory Capacity | 16 MB, up to 100,000 timestamped measurements |
| Power Options | Rechargeable 12 Ah lead-acid battery (operating range +10 to +40 °C) or non-rechargeable 5.5 Ah Li-SOCl₂ battery (–40 to +60 °C) |
| Waterproof Rating | IP68 (MP100-E: terrestrial |
| MP100-A | submersible up to 2 m standard, customizable to 10 m) |
| Dimensions | 135 × 65 × 33 mm |
| Display | 2×8 character LCD |
| Interface | USB, optional GSM/GPRS or LoRaWAN for remote data transmission |
| Software | FluorPen v1.1 (Windows 7+) for data export (CSV, Excel), kinetic curve visualization, and parameter batch analysis |
| Compliance | Designed for GLP-aligned long-term field deployment |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantPen N110 |
| Measurement Principle | Dual-Wavelength Reflectance Spectroscopy (565 nm & 760 nm) |
| Derived Parameter | Normalized Difference Greenness Index (NDGI) and NDGI-Calibrated Leaf Nitrogen Content (%) |
| Preloaded Calibrations | Wheat, Barley, Maize |
| Detector | PIN Photodiode with Bandpass Filters |
| Spectral Range | 500–800 nm |
| Data Storage | >100,000 measurements (16 MB internal memory) |
| Display | Graphical LCD |
| Interface | Bluetooth 5.0 (up to 20 m, 3 Mbps) + USB-C |
| Integrated GPS | Yes (CEP ≤1.5 m) |
| Power | Rechargeable 2000 mAh Li-ion battery (70 h continuous operation, auto-shutdown after 5 min idle) |
| Operating Temp. | 0–55 °C |
| RH | 0–95 % non-condensing |
| Dimensions | 135 × 65 × 33 mm |
| Weight | 188 g |
| Software | FluorPen 1.1 (Windows 7+) — supports data export to Excel, statistical averaging, time-series plotting, and calibration curve management |
| Brand | PSI (Czech Republic) |
|---|---|
| Model | PlantPen PRI 210 / NDVI 310 |
| Measurement Principle | Dual-wavelength reflectance ratio spectroscopy |
| PRI Band | 531 nm & 570 nm (detection range: 500–600 nm) |
| NDVI Band | 635 nm (red) & 760 nm (NIR) (detection range: 620–750 nm) |
| PRI Calculation | (R₅₃₁ − R₅₇₀) / (R₅₃₁ + R₅₇₀) |
| NDVI Calculation | (Rₙᵢᵣ − Rᵣₑ ) / (Rₙᵢᵣ + Rᵣₑ ) |
| Data Storage | 100,000 measurements (16 MB internal flash) |
| Connectivity | Bluetooth 1.1 + USB 2.0 |
| GPS | Integrated |
| Display | Graphical LCD |
| Power | Rechargeable Li-ion battery (70 h continuous operation) |
| Dimensions | 135 × 65 × 33 mm |
| Weight | 188 g |
| Operating Temp. | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| IP Rating | Sealed waterproof keypad |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScan |
| Import Status | Imported |
| Type | Automated Plant Phenotyping System with Chlorophyll Fluorescence, RGB 3D, Thermal, NIR, and Hyperspectral Imaging |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Automated High-Throughput |
| Compliance | CE, ISO 9001-certified manufacturing |
| System Capacity | 2160 custom agar plates (129 × 129 × 16.5 mm) |
| Imaging Sensors | CMOS, 12.36 MP (4112 × 3006), global shutter, 12-bit depth, GigE interface |
| Chlorophyll Fluorescence Excitation | 620 nm, 5700 K white, 735 nm far-red |
| Multispectral Fluorescence Excitation | 365 nm UV, 445/470/505/530/590 nm LEDs |
| VNIR Hyperspectral Range | 350–900 nm, 2 nm FWHM resolution, 480 spectral bands, 45 fps |
| LED Growth Light | Adjustable R:FR ratio (0.5–0.82), max irradiance 400 µmol/m²·s at 30 cm |
| Stratification Cabinet | Precise 5 °C dark control, 720-plate capacity |
| Environmental Control | Optional GMO-compliant growth chamber with HEPA + UV-C sterilization |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor Edition |
| Compliance | CE-marked, ISO 9001-certified manufacturing |
| Application Domain | Automated plant phenotyping, non-invasive physiological & structural imaging |
| Imaging Modalities | Chlorophyll fluorescence, RGB 3D, thermal IR, NIR water status, VNIR/SWIR hyperspectral |
| Throughput Capacity | Up to 200+ plants per day (standard tray configuration) |
| Enclosure Dimensions | 150 × 150 × 220 cm (L×W×H), light-isolated |
| Data Management | MySQL-based relational database with audit-trail logging, GLP-compliant metadata tagging |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor Edition |
| Compliance | CE, EN 60529, EN 55011, 2006/42/EC, 2004/108/EC, 73/23/EEC |
| Data Storage Capacity | 12 TB MySQL Database |
| Imaging Throughput | Up to 100 plants per 100 minutes (protocol-dependent) |
| Conveyor Capacity | Standard 50 pots (expandable to 400) |
| Max Plant Height | 200 cm |
| Weighing Accuracy | ±0.2 g (small plants), ±2 g (large plants) |
| Irrigation Flow Rate | 3 L/min |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Field |
| Key Features | Integrated chlorophyll fluorescence imaging (Fo, Fm, Fv/Fm, ΦPSII, NPQ, qP, qN, Rfd), RGB phenotyping (5 Mpx, leaf area, solidity, eccentricity, roundness, NDVI-equivalent greenness), thermal imaging (640×480 px, 7.5–13 µm, −20 to 120 °C), hyperspectral imaging (380–1000 nm, 675 bands), LiDAR 3D structural scanning, GPS-guided autonomous mobile platform (12 m arm span, 10 m swath, 2 cm positional accuracy), real-time data acquisition & cloud-enabled phenomics database (MySQL), daylight-adapted fluorometry with modulated 620 nm pulse light and 735 nm far-red actinic light, 720×560 px CCD (50 fps, 12-bit) or optional 1360×1024 px (20 fps, 16-bit), 35×35 cm standard imaging field (customizable to 80×80 cm) |
| Compliance | Designed for GLP-aligned field trials, supports ISO 22029 (plant phenotyping terminology), ASTM E2912 (spectral reflectance standards), and FAO/CGIAR phenotyping data interoperability guidelines |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen SC |
| Mobility | Integrated casters for intra-greenhouse repositioning |
| Standard Plant Capacity | Up to 70 cm height, 50 cm canopy diameter |
| Core Imaging Modules | FluorCam chlorophyll fluorescence imaging + RGB 3D morphometric imaging |
| Optional Modules | 3D laser triangulation scanning, hyperspectral imaging (400–1000 nm), thermal infrared imaging (7.5–14 µm), NIR imaging |
| Sample Handling | Barcode-scanned standardized trays (5×4, 2×2, 1×2, 1×1 configurations |
| Environmental Monitoring | Integrated temperature & relative humidity sensors with time-synchronized logging |
| Software Suite | PSI PlantScreen Control & Analysis Suite (includes experiment scheduling, automated acquisition, batch processing, relational database management, GLP-compliant audit trail) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen XYZ |
| Imaging Axes | X (0–101 cm, ±1 mm), Y (0–72 cm, ±1 mm), Z (0–49 cm, ±5 mm) |
| Max Payload (Z-axis) | 30 kg |
| Standard Footprint | 200 × 150 × 230 cm |
| Scan Area | 61 × 129 cm |
| Chlorophyll Fluorescence Imaging | 35 × 35 cm FOV, 1.3 MP sensor, 618 nm measuring light, white saturating flash up to 3600 µmol·m⁻²·s⁻¹, 735 nm IR source, 8-position filter wheel |
| RGB Imaging | 2592 × 1944 px (1/2.5″ sensor, 2.2 µm pixel size), timestamped & georeferenced (X/Y/Z) BMP output |
| NIR Imaging (optional) | 1450–1600 nm band, water absorption contrast |
| SWIR/VNIR Hyperspectral (optional) | 400–1000 nm or 1000–2500 nm, 150 × 100 cm FOV |
| Thermal Imaging (optional) | 640 × 480 px, 20–120 °C range, NETD < 50 mK @ 30 °C |
| Software | PSI FluorCam & PlantScreen Control Suite with protocol-driven automation, GLP-compliant metadata logging, audit trail, and export to CSV/HDF5 |