| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-500Q |
| Flow Rate | 0–40 mL/min |
| Max Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Wavelength | 280 nm ±3 nm |
| Optical Path Length | 2 mm |
| Detector Type | LED-based Single-Wavelength UV Detector |
| Gradient Formation | Precision Three-Position Solvent Selection Valve |
| Control Interface | Embedded Android Touchscreen + Optional PC Software (ClearFirst PC Edition) |
| Sample Compatibility | Aqueous Buffers for Biomolecule Purification |
| Tubing Material | Biocompatible, Low-Adsorption, Pressure-Rated Polymer |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ClearFirst-500S |
| Pricing | Available Upon Request |
| Flow Rate Range | 0–40 mL/min |
| Maximum System Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Detection Wavelength | 280 nm |
| Wavelength Accuracy | ±3 nm |
| Optical Path Length | 2 mm |
| Fraction Collector Capacity | Standard 48-position 18 mm tube rack (18 × 150 mm or 15 mL conical tubes) |
| Optional racks | 130-position 1.5 mL, 88-position 13 mm, 80-position 15 mm, 20-position 50 mL |
| Detector Type | LED-based Single-Wavelength UV Detector |
| Gradient Generation | Precision Three-Port Solvent Selection Valve |
| Control Interface | Embedded Android Touchscreen Workstation (ClearFirst Android Edition) + Optional PC-Based ClearFirst Software (Windows) |
| Compliance | Designed for GLP-compliant workflows |
| Material Compatibility | Biocompatible, pressure-rated fluidic path (PEEK, PTFE, fused silica capillaries, stainless steel fittings) |
| Method Storage | Onboard method library with recall and one-touch execution |
| Detection Options | Optional Conductivity Detector (electrode-based, analog signal processing) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800 |
| Functionality | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec per well |
| Sensitivity | 7 amol ATP per well |
| Plate Formats | 96-well and 384-well microplates |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Integration Time | User-Configurable |
| Software Interface | USB-Controlled Data Acquisition & Analysis Workstation |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800Plus |
| Price Range | USD 7,000–14,000 |
| Function Type | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Dual-Read, Kinetic |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec |
| Sensitivity | 7 amol ATP per well |
| Microplate Formats | 96-well & 384-well |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP Audit Trail, IQ/OQ/PQ Ready |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1000F |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–6 Abs |
| Linearity Range | 0–3 Abs (±2%) |
| Wavelength Measurement Speed | 6 s per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3 Abs) |
| Detector Type | Photodiode |
| Filter Capacity | Up to 16 positions (standard: 405, 450, 620 nm) |
| Plate Format | Standard 96-well microplates |
| Resolution | 0.001 Abs |
| Incubation Option | Optional heated incubator module (MF-10) |
| Control Interface | 7-inch capacitive touchscreen |
| Data Storage | 100 protocols + 100 × 96-well datasets |
| Connectivity | 3× USB (PC, USB drive, printer) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1500 |
| Detection Principle | Monochromator-based UV-Vis Absorbance |
| Wavelength Range | 190–1000 nm (1 nm step) |
| Optical Density Range | 0–4.000 OD |
| OD Linearity | ±0.01% in 0–2.0 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2.5 nm (2–10 nm customizable) |
| Stray Light | <0.01% (@230 nm) |
| OD Precision | CV <0.5% (@450 nm) |
| Read Time | 20 s per 96-well plate (dual-wavelength) |
| Plate Format | Standard and UV-transparent 96-well microplates |
| Detector Type | UV-Vis photodiode array |
| Light Source | Xenon flash lamp |
| Interface | 7-inch capacitive touchscreen + USB data export |
| Software | Onboard firmware with kinetic, endpoint, spectral scan, and curve-fitting modes (linear, point-to-point) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900 |
| Detection Principle | Absorbance (Photometric) |
| Wavelength Range | 190–900 nm |
| Optical Density Range | 0–4.000 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2–10 nm (customizable) |
| Incubation Temperature Range | Ambient to 45 °C |
| Plate Formats | Standard 96-well and UV-transparent 96-well microplates |
| Detection Modes | Single-, Dual-, and Multi-wavelength |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ protocols, GLP/GMP-ready |
| Optional Accessories | Dual-cuvette adapter plate (NA-10), incubation-shaking module (MF-10), multi-mode washer (MX-10), LIMS server (WS-10) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ReadMax 1900 |
| Price Range | USD 7,000–14,000 |
| Functionality | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, and Spectral Scan |
| Curve Fitting | Linear Regression Only |
| Detector Configuration | Dual-Detector System (Sample + Reference) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–4.000 OD |
| Linearity Range | 0–4.0 Abs |
| Kinetic Measurement Speed | 6 sec per single wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control Range | Ambient +2 °C to 65 °C |
| Plate Compatibility | Standard 96-well and UV-transparent 96-well microplates |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Port | Integrated Single-Cell Optical Path for Standalone UV-Vis Spectrophotometry |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900Plus |
| Detection Principle | Absorbance (Photometric) |
| Wavelength Range | 190–1000 nm |
| Optical Density Range | 0–4.000 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2–10 nm (configurable) |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well |
| Cuvette Mode | Integrated 1-cm pathlength cuvette port |
| Detection System | Dual photodiode detector (sample + reference) |
| Light Source | Pulsed xenon lamp |
| Kinetic & Spectral Scan Modes | Supported |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ validated, GLP/GMP-ready |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900Plus |
| Function Type | Absorbance-Only |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear Regression |
| Detector Configuration | Dual-Channel (Sample + Reference) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–4.000 OD |
| Absorbance Linearity | 0–4.000 OD |
| Kinetic Measurement Speed | 6 sec per wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control Range | Ambient +2°C to 65°C |
| Plate Compatibility | Standard 96-well and UV-transparent 96-well microplates |
| Light Source | Xenon Flash Lamp |
| Cuvette Port | Integrated UV-Vis spectrophotometer path |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ validated, GLP/GMP-ready audit trail |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 500F |
| Function Type | Absorbance-Only |
| Automation Level | Fully Automated |
| Assay Method | Endpoint |
| Calibration Curve Types | Single-Point & Linear Regression |
| Detector Type | Photodiode Array |
| Wavelength Range | 340–900 nm |
| Absorbance Range | 0–6 Abs |
| Linearity Range | 0–3 Abs (±2%) |
| Wavelength Switching Time | 6 s per filter |
| Precision | CV ≤ 0.2% (0–3 Abs) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000AL |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear regression |
| Detection Technologies | UV-Vis Absorbance, Chemiluminescence |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 OD (96-well, 450 nm) |
| Absorbance Linearity | 0–4 OD (±2% at 450 nm, 96-well) |
| Wavelength Scanning Speed | 6 sec per wavelength (kinetic mode) |
| Chemiluminescence Sensitivity | <7 amol ATP/well (flash-type ATP assay), dynamic range >7 decades |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Types | 96-well and 384-well microplates |
| Detection Detectors | Photodiode (absorbance), Photon-counting PMT (chemiluminescence) |
| Light Source | Xenon flash lamp |
| Plate Agitation | Linear, orbital, and circular shaking (adjustable amplitude) |
| Data Interface | USB 2.0 |
| Optional Modules | Dual-channel liquid dispenser (10–1000 µL), audit trail module, incubation shaker (MF-10) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000FA |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | Linear regression |
| Detection Modes | Fluorescence (top/bottom read), UV-Vis Absorbance |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 Abs (96-well, 450 nm) |
| Absorbance Linearity | ±2% (0–4 Abs, 96-well, 450 nm) |
| Kinetic Read Speed | 6 sec per wavelength (single-wavelength) |
| Fluorescence Sensitivity | Top-read < 0.5 fmol FITC/well (384-well plate) |
| Dynamic Range | >6 decades (top-read), >5.5 decades (bottom-read) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | < ±0.2 nm (fluorescence), ±1.0 nm (absorbance) |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Bandwidth Options | 10 nm or 20 nm |
| Light Source | Xenon flash lamp |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-well and 384-well standard (custom formats available) |
| Shaking Modes | Linear, orbital, circular with adjustable amplitude |
| Detector Configuration | Dual PMT (sample + reference) for fluorescence |
| Data Interface | USB 2.0 |
| Software | SuPerMax Workstation (with audit trail option) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000FL |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear, Log-Log, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Quadratic, Cubic, Spline |
| Detection Modes | Fluorescence (Top/Bottom Read), Luminescence (Photon-Counting PMT) |
| Wavelength Range | 190–1000 nm (Monochromator-Based) |
| Absorbance Range | 0.000–2.000 OD |
| Absorbance Linearity | ±0.01 OD (0.000–2.000 OD) |
| Wavelength Accuracy | < ±0.2 nm |
| Wavelength Resolution | 1 nm |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Fluorescence Sensitivity | < 0.5 fmol FITC/well (Top Read, 384-well) |
| Luminescence Sensitivity | < 7 amol ATP/well (Flash Reaction) |
| Dynamic Range | > 6 decades (Fluorescence, Top Read) |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-, 384-well standard |
| Shaking Modes | Linear, Orbital, Dual-Axis |
| Light Source | Xenon Flash Lamp |
| Data Interface | USB 2.0 |
| Software Compliance | Audit Trail (optional), User Access Control, Electronic Signature Support (21 CFR Part 11-ready configuration) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3100 |
| Function Type | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear |
| Detectors | Photomultiplier Tube (PMT) for Fluorescence & Luminescence, Photodiode for Absorbance |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 Abs (96-well, 450 nm) |
| Absorbance Linearity | 0–4 Abs (±2% at 450 nm, 96-well) |
| Wavelength Accuracy | ±1.0 nm |
| Kinetic Read Time (Single Wavelength) | 6 sec |
| Excitation Range | 190–1000 nm |
| Emission Range | 270–850 nm |
| Fluorescence Sensitivity (Top Read) | <0.5 fmol FITC/well (384-well) |
| Chemiluminescence Sensitivity | <7 amol ATP/well (flash reaction) |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Formats | 96-, 384-well (custom formats supported) |
| Reading Modes | Top & Bottom |
| Light Source | Xenon Flash Lamp |
| Data Interface | USB 2.0 |
| Software | SuPerMax Workstation with Audit Trail (optional) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotechnology Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3200 |
| Detection Modes | Absorbance, Fluorescence, Luminescence |
| Automation Level | Fully Automated |
| Wavelength Range | 190–1000 nm (Abs/Fluor Excitation), 270–850 nm (Fluor Emission), 300–650 nm (Luminescence) |
| Absorbance Linearity | 0–4 Abs (96-well, 450 nm), ±2% |
| Fluorescence Sensitivity | < 0.4 fmol FITC/well (top-read, 384-well plate) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Temperature Control | RT+2°C to 65°C |
| Plate Formats | 6- to 384-well microplates |
| Read Modes | Top & Bottom Reading |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3500 |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (190–1000 nm, monochromator-based), Fluorescence (top/bottom reading, TRF, FP), Luminescence (photon-counting PMT) |
| Detectors | Photodiode, Standard PMT, Photon-Counting PMT |
| Excitation Sources | Tungsten-halogen lamp, Xenon flash lamp |
| Wavelength Selection | Dual-path — monochromator or filter-based |
| Curve Fitting | Linear, quadratic/cubic/quartic polynomial, 4PL/5PL, log, exponential, double-logarithmic |
| Incubation Range | Ambient to 65 °C (±0.2 °C uniformity at 37 °C) |
| Plate Formats | 6–1536-well microplates |
| Software | Integrated workstation with formula editor, audit trail, GLP-compliant data handling, and automation-ready API |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax-3100 |
| Function Type | Multimode |
| Automation Level | Fully Automated Microplate Reader Workstation |
| Assay Modes | Endpoint Fluorescence, Absorbance, Chemiluminescence (ELISA/EIA) |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detectors | Photodiode (Absorbance), PMT (Fluorescence), Photon Counting PMT (Chemiluminescence) |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Excitation & Emission Monochromators | Dual high-resolution grating monochromators |
| Bandwidth | Adjustable from 2 to 20 nm |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well (customizable to 24-, 384-, 1536-well) |
| Dispensing Capability | Dual-channel liquid handler (expandable to quad-channel) |
| Reading Modes | Top-read and bottom-read fluorescence |
| Kinetic & Spectral Scanning | Supported |
| Software Compliance | IQ/OQ/PQ validated |
| Brand | Shanghai Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Absorbance-Based Microplate Reader |
| Automation Level | Fully Automated |
| Wavelength Range | 190–1000 nm |
| Optical System | Monochromator-Based (Grating) with Dual-Detector Architecture (8 Sample + 8 Reference Channels) |
| Temperature Control | Ambient to 65 °C (Uniformity: ±0.2 °C at 37 °C) |
| Built-in Functions | Plate Incubation, Orbital Shaking |
| Optional Module | Standalone Cuvette Holder (1-cm Pathlength) |
| Pathlength Correction | Integrated Optical Pathlength Conversion Algorithm (Converts Microplate OD to Equivalent 1-cm Cuvette OD) |
| Data Analysis Models | Linear, Quadratic, Cubic, Quartic, 4-Parameter Logistic (4PL), 5-Parameter Logistic (5PL), Logarithmic, Exponential, Double-Logarithmic Fitting |
| Software | PC-Based Control & Analysis Suite with Formula Editor, Audit Trail, and Export (CSV, Excel, PDF) |
| Brand | FlowCam |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowCam 8000 |
| Pricing | Available Upon Request |
| Brand | Flownamics |
|---|---|
| Origin | USA |
| Model | FISP Sterile Sampling Probe |
| Construction | 316 Stainless Steel |
| Membrane Material | Ceramic |
| Standard Pore Size | 0.2 µm |
| Optional Pore Sizes | 0.45, 0.75, 1.0, 5.0, 25.0, 75.0 µm |
| Port Compatibility | D-Series (19 mm & 25 mm side ports), F-Series (8 mm, 12 mm & 19 mm top ports) |
| Immersion Depth Options | 90–410 mm |
| Dead Volume | 0.24–0.44 mL |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | Fluent NAE Workstation |
| Extraction Methods | Magnetic Bead-Based Isolation, Solid-Phase Extraction |
| Liquid Handling Technology | Air-Displacement Pipetting |
| Dynamic Range | 0.5 µL – 1,000 µL |
| Tip Type | Disposable Filter Tips |
| Throughput | Parallel Processing with Synchronized Dual-Arm Motion |
| Sample Tracking | Integrated 2D Barcode Scanner and Optional RFID Reader |
| Module Flexibility | Configurable with Shaking, Vacuum Filtration, and Magnetic Separation Modules |
| Safety Features | Real-Time Aspiration/Dispense Monitoring, Clog Detection, Tip Presence Verification |
| Brand | Fluicell |
|---|---|
| Origin | Sweden |
| Model | Fluiwell-BioPen |
| Flow Precision (PRIME chip) | 7–25 nL/s |
| Solution Switching Speed | Sub-second (<1 s) |
| Nozzle Compatibility | Universal microscope integration (standard inverted & upright configurations) |
| Chip Types | PRIME (high-precision, low-volume) and FLEX (modular, multi-channel) disposable chips |
| Control Interface | PC-based Fluicell Control Software v3.x |
| Regulatory Compliance | CE-marked for research use only (RUO), compliant with ISO 13485 design controls for medical device components |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CCS-01 |
| Instrument Type | Automated |
| Reservoir Volume | 15 mL |
| Dimensions (H×W×D) | 18 × 17.7 × 16 cm (including reservoir) |
| Temperature Control Range | 15–40 °C |
| Minimum Perfusion Volume | 1 mL |
| Flow Rate Range | 0.8–400 µL/min |
| Independent Fluid Channels | 2 or 4 |
| Tubing Compatibility | Tygon® L/S 0.38 mm ID / 0.8 mm OD |
| Pressure Limit | ≤0.1 MPa |
| Power Supply | AC 220 V, 50 Hz, <10 VA |
| Operating Temperature | 15–40 °C |
| Weight | 1.5 kg |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Flow Cell |
| Price | USD 1,350 (approx.) |
| Instrument Type | Manual |
| Dimensions (L×W×H) | 60 × 65 × 15 mm |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Region of Origin | Domestic (China) |
| Model | LNP-B1 (with Luer Fitting) |
| Chip Material | Cyclic Olefin Copolymer (COC) |
| Chip Type | Droplet-Generation Microfluidic Chip |
| Dimensions (mm) | 62.2 × 41.3 |
| Channel Width | 350–700 µm |
| Max Operating Pressure | 50 bar |
| Total Fill Volume | 8.22 µL |
| Mixing Structure Volume | 2.09 µL |
| Recommended Total Flow Rate | 16 mL/min |
| Maximum Total Flow Rate | 40 mL/min |
| Compatible Instruments | FluidicLab LNP-S1 & LNP-S2 Intelligent Lipid Nanoparticle Synthesizers |
| Application Range | Total Synthesis Volume 0.4–40 mL |
| Flow Regime | Medium-volume, medium-flow-rate LNP formulation |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | PDMS-HTS-80 |
| Price | USD 185 (excl. VAT & shipping) |
| Chip Material | Covalently bonded PDMS microchannels on borosilicate glass substrate |
| Chip Type | Step-emulsion droplet generation chip |
| Channel Width | 160 µm |
| Nozzle Geometry | Parallel stepped orifice array (188 independent units) |
| Droplet Diameter Range | 80–100 µm |
| Aqueous Phase Flow Rate Range | 10–1000 µL/min (CV < 5% under stable pressure control) |
| Substrate Dimensions | 75 × 25 × 2 mm (glass), Chip Active Area: 62 × 19 × 2 mm |
| Surface Treatment | Hydrophobic silanization of PDMS channels |
| Operational Configuration | Dual-inlet/dual-output symmetric layout (Chip I: Inlets ①/② → Outlet ③ |
| Chip II | Inlets ④/⑤ → Outlet ⑥) |
| Brand | FLUIDOT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | FLUIDOT (Original Equipment Manufacturer) |
| Model | FDT-MF120 |
| Configuration | Three independent peristaltic pump channels |
| Display | 10-inch capacitive touchscreen |
| Maximum dish capacity per stacker | 40 × 90 mm Petri dishes (3 stackers total) |
| Dispensing modes | 5 programmable modes (Auto-Dispense, Auto-Dispense + Manual Sample Addition, Auto-Dispense + Auto-Sample Addition, Manual Dispense, Label Printing) |
| Pump control | Individual on/off and speed control for each of 3 peristaltic pump heads |
| Parameter storage | Up to 5 complete dispensing & oscillation protocols |
| Oscillation control | Independent X/Y-axis oscillation speed, amplitude, cycle count, and repeat iterations |
| Sterilization | Built-in UV-C lamp in dispensing chamber |
| Optional accessories | Integrated sample auto-sampler module, media temperature-controlled stirring unit, footswitch interface |
| Compliance | Designed for ISO 13485-aligned laboratory environments |
| Brand | Fluidot |
|---|---|
| Model | FDT-MF80 |
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Category | Domestic (China-made) |
| Pricing | Upon Request |
| Plate Capacity per Stack | 40 × 3 Stacks |
| Dispensing Modes | 4 (Auto-Dispense Only |
| Dispensing Pump Options | Single or Dual Peristaltic Pump Head |
| Tubing | Removable & Autoclavable |
| UV Sterilization | Integrated in Dispensing Chamber |
| Sample Mixing | Programmable Orbital Shaking (Amplitude & Cycle Count Adjustable) |
| Liquid Priming & Post-Dispense Aspiration | Automatic |
| Touchscreen Interface | Full-Function HMI with Parameter Programming (Volume, Speed, Shake Profile, Stack Control) |
| Safety Features | Real-time Petri Dish Presence Detection, Emergency Stop, Footswitch-Compatible Operation |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | ARIA |
| Instrument Type | Automated |
| Reservoir Capacity | 2 mL & 15 mL (8 positions) + 100 mL rinse reservoir |
| Flow Rate Range | 40 µL/min to 1 mL/min (water, typical) |
| Pressure Supply | Up to 2 bar |
| Capillary ID/OD | 250 µm / 1.59 mm, FEP material |
| Software | Windows 7 or later |
| Compliance | Designed for GLP-compliant live-cell imaging workflows, compatible with FDA 21 CFR Part 11–ready data logging when integrated with validated software environments |