Life Science Instruments
Filter
Showing 2611–2640 of 7567 results
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Fluigent-perfusion |
| Automation Level | Fully Automated |
| Reservoir Capacity | mL-scale |
| Flow Rate Range | nL/min to mL/min |
| Flow Velocity Range | nL/min to mL/min |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | FRP Flow Rate Platform (comprising FLOW UNIT sensor + FLOWBOARD controller) |
| Flow Range Options | 7 nL/min to 5 mL/min |
| Sensor Types | XS, S, M, L, XL |
| Communication Interface | USB |
| Max Channels per FLOWBOARD | 8 |
| Software | Fluigent AIO (All-in-One) v3.x |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-compatible lab environments |
| Instrument Category | Microfluidic Chip System |
| Integration | Standalone or embedded in pressure-driven microfluidic control setups |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | OMI |
| Instrument Type | Fully Automated, Battery-Powered |
| Reservoir Capacity | 4 × 4 mL |
| Device Height | 6 cm |
| Footprint | < 12 cm × 8 cm |
| Weight | < 800 g |
| Flow Rate Range | 0.1–100 µL/min (adjustable per channel) |
| Flow Control Precision | ±2% CV |
| Operating Environment | Standard CO₂ incubator (37 °C, 5% CO₂) |
| Power | Rechargeable Li-ion battery (2 h continuous operation) |
| Connectivity | Wi-Fi & Bluetooth 5.0 |
| Control Interface | Web-based dashboard & tablet app |
| Data Storage | Encrypted cloud sync with local backup |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Fluigent-PLGA |
| Chip Type | Raydrop™ |
| Chip Material | Fluorinated Ethylene Propylene (FEP) with Integrated Glass Viewing Window |
| Detection Limit | Sub-micron droplet resolution via high-speed digital microscopy |
| Channel Dimensions | 1–50 µm (standard Raydrop chip configurations) |
| Target Analyte | Poly(lactic-co-glycolic acid) (PLGA) micro/nanoparticles |
| Solvent Compatibility | Ethyl acetate, dichloromethane, acetonitrile, and other low-surface-tension organic solvents |
| Brand | PSI (Photosynthesis Systems Instruments) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Desktop Multispectral Fluorescence Imaging System |
| Imaging Area | 13 × 13 cm |
| CCD Frame Rate | Up to 50 fps |
| OJIP Kinetics Acquisition | Yes (optional module) |
| QA Reoxidation Kinetics | Yes (STF pulse ≤100 µs, up to 120,000 µmol·m⁻²·s⁻¹) |
| Protocol Flexibility | Fully programmable, multi-step fluorescence protocols with time-stamped automated cycles |
| Dual-Color Actinic Light Sources | Standard red + white |
| Optional Modules | TetraCam RGB imaging (20 × 25 cm), hyperspectral imaging unit, infrared thermography unit, GFP imaging capability |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam GFP/Chl |
| Imaging Area | 40 mm × 40 mm |
| CCD Sensor | TOMI-2, 1360 × 1024 pixels, 16-bit A/D, 20 fps max |
| Excitation Wavelengths | 610–620 nm (Measuring Light), 440–450 nm (Actinic & Saturating Light), 735 nm (Far-Red Light) |
| Irradiance | Up to 4500 µmol(photon)·m⁻²·s⁻¹ (Saturating Light), 1200 µmol(photon)·m⁻²·s⁻² (Actinic Light) |
| Filter Options | Red Chlorophyll Fluorescence Filter, Green GFP-Specific Filter |
| Spectral Detection Range | 400–1000 nm |
| Weight | 2 kg |
| Dimensions | 194 × 182 × 280 mm |
| Power Supply | 100–240 V AC or Optional Field Battery Pack (≥10 h operation) |
| Operating Environment | 5–40 °C, 0–90% RH (non-condensing) |
| Compliance | Firmware-upgradable BIOS, GLP/GMP-ready data logging with timestamped auto-storage |
| Brand | PSI (Photosynthesis Systems Instruments, Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam HT |
| Imaging Area | Up to 80 × 80 cm (standard 35 × 35 cm) |
| Fluorescence Sensor | High-sensitivity CCD, 1392 × 1040 pixels (15 fps), 12-bit A/D |
| RGB Sensor | 2560 × 1920 pixels, 1/2.5″ format |
| IR Thermal Camera (optional) | 640 × 480 pixels, NETD < 50 mK @ 30°C, 20–120°C range |
| Scan Precision | ±0.1 mm positional accuracy |
| Scan Speed | Up to 150 mm/s |
| Sample Throughput | 12 pots (Ø ≈ 30 cm) in < 60 s |
| Fluorescence Parameters | >50 standard PAM-derived parameters (Fo, Fm, Fv/Fm, NPQ, QY_Ln, Rfd, etc.) |
| Software | FluorCam v7.x with GLP-compliant audit trail, protocol scripting, remote web access, multi-user role management |
| Compliance | Designed for ISO/IEC 17025-aligned lab workflows |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | Fluorcam |
| Image Resolution | 12-bit, 512 × 512 pixels |
| Frame Rate | 50 fps |
| Data Interface | USB 2.0 |
| Spatial Resolution | ~1 mm (macro mode) |
| Excitation Sources | High-power LED arrays (450 nm, 625 nm, white), optional halogen lamp with shutter/LCD for continuous actinic light and saturating pulses |
| Detection | High-sensitivity cooled CCD camera with spectral response optimized for chlorophyll *a* fluorescence (680–750 nm) |
| Software | FluorCam 7.x with programmable protocol engine, ROI-based kinetic analysis, multi-parameter false-color mapping, and GLP-compliant audit trail (optional FDA 21 CFR Part 11 module) |
| Brand | PSI (PhotoSystems Instruments) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Open-Field Chlorophyll Fluorescence Imaging System |
| Imaging Area | Standard 13 × 13 cm |
| CCD Sensor | TOMI-2, 1360 × 1024 px, 16-bit A/D, 6.45 µm pixel size, 20 fps max |
| Light Sources | 4 × LED panels (617 nm measuring light |
| dual actinic | 617 nm + white or 617 nm + 470 nm |
| Fluorescence Parameters | >50 including Fo, Fm, Fv/Fm, ΦPSII, NPQ, qL, ETR, Rfd, QY_Ln, FtDn, etc. |
| Software | FluorCam v8.x with protocol scripting, ROI analysis (>1000 regions), timestamped automated acquisition, dual averaging modes, export to Excel & video |
| Optional Modules | TetraCam RGB imaging (20 × 25 cm), PAR/NDVI (735 nm + 650 nm), GFP/YFP/DAPI imaging (with 7-position filter wheel & UV/blue/green LED panels), multi-spectral fluorescence capability |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model Variants | Desktop, Floor-standing, Large Floor-standing |
| Excitation Light Sources | UV–NIR LED Array (365 nm, 450 nm, 470 nm, 490 nm, 520 nm, 590 nm, 630 nm, 735 nm, White Cold LED) |
| Fluorescence Detection Channels | Adjustable via Motorized Filter Wheel (FRET-compatible filters for GFP, RFP, YFP, BFP, CFP, SYBR Green, DAPI, etc.) |
| Imaging Area | Up to 35 × 35 cm |
| Sample Height Range | 20–100 cm (motorized adjustable stage) |
| Measurement Modes | PAM-modulated chlorophyll fluorescence imaging, OJIP transient kinetics imaging, multicolor steady-state fluorescence imaging, chlorophyll distribution mapping, fluorescent protein expression profiling, secondary metabolite fluorescence profiling |
| Software | FluorCam 7.0 with automated protocol scheduling, time-stamped data archiving, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam |
| Detector | High-sensitivity CCD (400–1000 nm, 512×512 px, 8.2×8.4 µm pixel size) |
| Frame Rate | Up to 50 fps |
| Fluorescence Parameters | F₀, Fₘ, Fᵥ, F₀′, Fₘ′, Fᵥ′, QY(II), NPQ, ΦPSII, Fᵥ/Fₘ, Fᵥ′/Fₘ′, Rfd, qN, qP, ETR, and >50 additional derived parameters |
| Actinic Light Sources | White, blue (450 nm), red (620 nm) |
| Measuring Light | 620 nm red LED, pulse width 10–100 µs adjustable |
| Far-Red Light | 735 nm IR LED |
| Uniform Illumination Area | 2.5 × 2.5 cm |
| Excitation Modes | Static or dynamic light regimes |
| Software-Controlled Protocols | Fᵥ/Fₘ, Kautsky induction kinetics, fluorescence quenching analysis, light-response curves, custom script-based experiments |
| Data Interface | USB 2.0 |
| Power Supply | AC adapter or rechargeable battery (field operation) |
| Weight | 1.8 kg |
| Optional Accessories | Handheld OJIP fluorometer module, rugged tablet-based industrial PC |
| [Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | FluorCam Series |
| Key Features | PAM-modulated chlorophyll fluorescence imaging |
| Sensor Options | Up to 1280×1024 px, 16,000 fps OJIP-capable sensor |
| Imaging Area | 31.5×41.5 mm (portable) to 35×35 cm (large-scale platform) |
| LED Excitation Sources | Customizable multi-wavelength (red, blue, white, UV, far-red) |
| Software | FluorCam v8.x with protocol editor, GLP-compliant audit trail, lifetime free updates |
| Compliance | ASTM E2912-22 (fluorescence imaging standards), ISO 17025 traceable calibration support, FDA 21 CFR Part 11 optional module] |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluorCam-Pro |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluorCam-WIC |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UV-MCF |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FluorTron®-Robot |
| Pricing | Upon Request |
| Brand | KISSEI |
|---|---|
| Origin | Japan |
| Model | BAS-8103 |
| Power Supply | +5 V ±5% (from PC AD card) |
| Current Consumption | < ±2.8 mA |
| Input Connector | 2-pin socket |
| Number of Channels | 3 |
| Gain Settings | 100, 200, 500, 1000 µV/V |
| Low-Pass Filter Cutoff Frequencies | 100, 250, 500, 1000 Hz |
| High-Pass Filter Cutoff Frequencies | 0.5, 2, 5, 10 Hz |
| Input Impedance | > 10 MΩ |
| Input-Referred Noise | < 5 µVp-p |
| Weight | < 40 g |
| Dimensions | 65 × 35 × 100 mm |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Human Energy Metabolism Laboratory System |
| Price Range | USD 28,000 – 70,000 |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS |
| Pricing | Upon Request |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FMS Portable |
| Pricing | Available Upon Request |
| Dimensions | 35 × 30 × 15 cm |
| Weight | 4 kg |
| Power Supply | 12–15 VDC (AC adapter included) |
| Data Storage | Internal 32 GB SD card (user-replaceable) |
| Operating Temperature | 3–50 °C (non-condensing) |
| Gas Flow Range | 10–1500 mL/min |
| O₂ Sensor | Fuel cell, ~2-year service life, field-replaceable |
| CO₂ Sensor | Nondispersive dual-wavelength infrared (NDIR) |
| H₂O Sensor | Thin-film capacitive |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| H₂O Range | 0–100% RH (no condensation) |
| Atmospheric Pressure Range | 30–110 kPa |
| Temperature Range | 0–100 °C |
| O₂ Accuracy | ±0.1% of reading (2–100%) |
| CO₂ Accuracy | ±1% of reading (0–5%) |
| H₂O Accuracy | ±1% RH (0–95%), ±2% RH (95–100%) |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% |
| H₂O Resolution | 0.001% RH |
| O₂ Drift | <0.02% per hour (isothermal) |
| CO₂ Drift | <0.001% per hour (isothermal) |
| H₂O Drift | <0.01% RH per hour (isothermal) |
| Analog Inputs | 8-channel bipolar voltage |
| Temperature Inputs | 4-channel |
| Analog Outputs | O₂, CO₂, +2 user-defined |
| Digital Control Outputs | 8 × TTL logic |
| Digital Interface | USB-to-RS-232, SableBus high-speed interface |
| Sampling Interval | 0.1 s to 1 h (user-configurable) |
| Flow Control Accuracy | ±2% of reading |
| Flow Resolution | 0.1 mL/min (0–99.9), 1 mL/min (>100) |
| Environmental Compensation | Automatic temperature & barometric pressure compensation |
| Display | High-resolution capacitive touchscreen (real-time multi-parameter visualization) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | R21014-1 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FST-00 |
| Pricing | Available Upon Request |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJL-200 |
| Instrument Type | Fully Automated Colony Counter |
| Petri Dish Compatibility | ≤150 mm diameter |
| Counting Speed | <1 second for ≤500 colonies |
| Colony Size Detection Range | 0.08–100 mm |
| Counting Modes | Fully Automatic, Manual, Spiral Plate Mode |
| Image Resolution | 1080×720 to 2160×1440 pixels |
| Custom Dilution Series Support | Yes |
| Illumination | Dual-mode cold LED source (top and bottom transillumination) |
| Operating Environment | 10–40 °C, ≤80% RH |
| Reporting | Exportable electronic reports (PDF, CSV, Excel), printable hardcopy |
| Software Interface | LIS-compatible (HL7, ASTM E1384 compliant) |
| Hardware Interface | USB 2.0 |
| Brand | Forevergen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MicroDrop-100 |
| Instrument Type | Droplet Digital PCR System |
| Sample Volume | 20 µL |
| Microdroplets per Reaction | 100,000 |
| Droplet Generation Time | 2 min/chip |
| Throughput (Prep) | 1–8 samples/chip |
| Throughput (Detection) | 1–96 samples/run |
| Linear Dynamic Range | 6 logs |
| Sensitivity | 0.01% (1 in 10,000) |
| Detection Channels | FAM, HEX (VIC) |
| Dimensions (MicroDrop-100A) | 300 × 400 × 145 mm |
| Dimensions (MD Detector) | 700 × 500 × 325 mm |
| Software | QuantDrop Analysis Suite |
| Brand | FOREVERGEN |
|---|---|
| Model | OE |
| Instrument Type | Fully Automated |
| Detection Method | Visible Light Absorption Spectroscopy |
| Measured Gases | CO₂, O₂ |
| Accuracy | ≤ ±1–2% of Full Scale |
| Dimensions (W×D×H) | 430 × 350 × 120 mm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | 311 |
| Temperature Range & Accuracy | Ambient +5°C to 50°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Control | >90% rH at 37°C |
| Chamber Capacity | 184 L (6.5 cu. ft.) |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUVIS® |
| Field of View (mm) | 3.7 × 3.0 |
| Pixel Size (µm) | 1.1 |
| Optical Resolution (µm) | 2 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RI1 |
| Field of View (mm) | 6.1 × 5.0 – 1.9 × 1.5 |
| Pixel Size (µm) | 1.8 – 0.56 |
| Optical Resolution (µm) | 5 – 1 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI360 / RI1000 |
| Field of View (mm) | 9.49 – 0.79 |
| Pixel Size (µm) | 3.20 – 0.27 |
| Optical Resolution (µm) | 4.39 – 0.83 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SONICC® |
| Price | Upon Request |
| Field of View (mm) | 2.2 × 2.2 to 0.65 × 0.65 |
| Optical Resolution (µm) | 4.0 to 1.1 |