| Brand | Labsphere |
|---|---|
| Model | LFFP-200-N |
| Origin | USA |
| Light Source Type | Tunable White LED Array |
| Color Temperature Range | 3000 K – 6000 K (continuously adjustable) |
| Luminance Range | 100 – 15,000 cd/m² (nit) |
| Active Emitting Area | 200 mm × 200 mm |
| Spatial Uniformity | ≥95% across active area |
| Control Interface | SDK available for C/C++, Python, LabVIEW, and .NET (English, Chinese, Japanese localizations supported) |
| Compliance | CE, RoHS, FCC Class A |
| Brand | LabSphere |
|---|---|
| Model | LFUSS |
| Coating | Spectraflect® or Spectralon® |
| Internal Diameter Options | 15 cm – 200 cm |
| Spectral Range | 350–2500 nm |
| Calibrated Radiance Range | 0–40,000 nit |
| Uniformity | ≥98% |
| Stability | ±0.1% |
| Light Source Type | Tungsten-halogen (150 W external + multiple internal options: 35/75/100/150 W) |
| Illumination Method | Internal illumination |
| Motorized Attenuator | ≥35,000 steps |
| Calibration Traceability | NIST and NIM (China National Institute of Metrology) |
| Operating Temperature | 20–40 °C |
| Detector Type | Silicon photodiode |
| Validated Spectral Calibration Range | 360–1100 nm |
| Color Temperature | 2856 ± 50 K |
| Aperture Configurations | Dual detector ports + variable source access ports |
| Software Compatibility | LabSphere Uniform Source Measurement Software (customizable) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LS-LED-Production |
| Uniformity (Exit Port) | ≥98% |
| Exit Port Diameter | 45 mm |
| CCT Tuning Range | Adjustable Continuous from Warm to Cool White (Typ. 2700 K – 6500 K) |
| Illuminance Tuning Range | Continuously Adjustable (0–10,000 lx typical at port) |
| Control Resolution | Millisecond-level Setpoint Response |
| Power Supply | Integrated Multi-channel Constant-Current LED Drivers |
| Monitoring | Real-time Photometric Feedback (Illuminance, LED Forward Voltage/Current Decay) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
| Optional Add-on | Spectral Monitoring Module (VIS, 380–780 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | PT-038-PLS |
| Light Source Type | Tungsten-Halogen (Standard Configuration) |
| Spectral Range | 380–1000 nm (Typical) |
| Luminance Range | 0.1–10,000 cd/m² (Adjustable via Precision Attenuation) |
| Uniformity | ≤ ±0.5% over Central 80% Area |
| Stability | ≤ ±0.2% over 30 min (Thermally Stabilized) |
| Portability | Integrated Battery Option (Optional), < 8 kg |
| Compliance | NIST-Traceable Calibration Certificate Included |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPECTRA-CT |
| Light Source Type | Tunable Broadband LED-Based Integrating Sphere Source |
| Illumination Method | Internal Illumination |
| Key Dimensions (CT-1000-S / M / L) | 20/30/50 cm sphere diameter |
| Output Aperture | 5/10/20 cm |
| Spectral Range | UV-Vis-NIR (250–1700 nm) |
| Luminance Range | 0.1–500,000 cd/m² (model-dependent) |
| Uniformity | >99% (per EMVA 1288 Annex A) |
| Color Temperature Range | 2800–7500 K |
| CCT Uniformity | ±15 K |
| Short-Term Stability | ±0.1% over 10 min |
| Warm-up Time | ≤30 s |
| Monitoring Sensor | Integrated Silicon Photodiode |
| Control Interface | USB + Ethernet |
| Software SDK | Yes (C/C++, Python, LabVIEW compatible) |
| Compliance | Fully supports EMVA 1288:2016 for camera characterization |
| Brand | Labsphere |
|---|---|
| Model | Spectra-FT |
| Origin | USA |
| Light Source Type | Tungsten-Halogen & LED Hybrid Spectral Engine |
| Spectral Range | 390–1000 nm |
| Luminance Range | 10–25,000 cd/m² |
| Field Uniformity | >98% over 360° × 200° FOV |
| Calibration Traceability | NIST-traceable spectral radiance |
| Feedback System | Integrated spectroradiometric real-time feedback loop |
| Re-calibration | User-executable via SpectraSoft™ v4.2 |
| Compliance | ASTM E308, ISO/CIE 11664, USP <1033>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-FT VIS-NIR |
| Output Aperture | 75 mm (Ø) |
| Spectral Range | 380–1050 nm |
| Max Luminance | 25,000 cd/m² |
| LED Channels | 32 |
| Uniformity | >98% over 360° × 200° FOV |
| Integrated Spectrometer | Yes |
| Compliance | ISO/IEC 17025 traceable calibration support, NIST-traceable spectral radiance characterization available |
| Software Control | USB/Ethernet, Labsphere SpectraSuite™ v5.0+ with real-time feedback loop |
| Operating Temperature Stability | ±0.1°C active thermal regulation |
| Radiometric Accuracy | ±2.5% (k=2, 380–950 nm, relative to NIST SRM) |
| Brand | Labsphere |
|---|---|
| Model | Spectra-PT |
| Origin | USA |
| Light Source Type | Integrating Sphere-Based Uniform Radiance/Luminance Source |
| Sphere Diameter | 13.5 cm |
| Output Port Diameter | 5 cm |
| Variable Aperture | Motorized, Precision Automatic (VA) |
| Built-in Reference Photodetector | Yes |
| Luminance Range | 0.01–50,000 cd/m² (continuous, programmable) |
| Spectral Output | Broadband (Xenon or Mercury-based, configurable) |
| Calibration | NIST-traceable spectral radiance and luminance |
| Compliance | ISO/IEC 17025-accredited calibration certificate included |
| Software Interface | LabVIEW-compatible, USB/Ethernet control, GUI for preset definition and real-time monitoring |
| Form Factor | Integrated benchtop enclosure with mobility handles |
| Optional Configuration | Wide-Angle Field-of-View (WAF) version available for >180° FOV imaging systems |
| Brand | Labsphere |
|---|---|
| Model | Spectra-UT |
| Origin | USA |
| Light Source Type | Tunable Hyperspectral Source with Integrated Tungsten-Halogen (QTH) Reference Lamp and Onboard Spectrometer |
| Spectral Range | 380–780 nm (Visible) |
| Spectral Resolution | Adjustable down to ~10 nm FWHM |
| Output Uniformity | >98% over 50 mm Ø field (flat-field compliant) |
| Control Interface | USB 2.0 + Ethernet |
| Software | SpectraSoft v4.x (Windows-based, supports scripting via Python API) |
| Calibration Traceability | NIST-traceable via integrated QTH lamp and factory-characterized spectrometer |
| Compliance | ISO/IEC 17025–accredited calibration documentation available |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Cooling | Forced-air thermal management system |
| Dimensions | 320 × 240 × 180 mm (W × D × H) |
| Weight | 8.2 kg |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-UT |
| Light Source Type | Tunable Solid-State Spectral Source |
| Illumination Mode | External Illumination |
| Spectral Range | 390–780 nm |
| FWHM | 12 nm ± 2 nm |
| Peak Wavelength Spacing | 0.4 nm |
| Spectral Accuracy | < 0.5 nm |
| Max Luminance | 1000 cd/m² |
| Luminance Adjustment Range | 25–1000 cd/m² |
| Luminance Uniformity | ≥99% |
| Max Spectral Scan Rate | < 1.0 spectrum/sec |
| Brand | Labthink |
|---|---|
| Model | SPS-80T |
| Light Sources | CIE Standard Illuminant D65 (6500 K, Ra > 90) and Illuminant A (2900 K, Ra = 100) |
| Viewing Area | 1050 mm × 700 mm |
| Cabinet Dimensions | 1050 mm (L) × 800 mm (W) × 2100 mm (H) |
| Net Weight | 40 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Illumination Method | External Projection |
| Compliance | CIE No. 51, ISO 3664:2009, CY/T 3–1991, ASTM D1729, DIN 6173-2 |
| Brand | Labthink |
|---|---|
| Model | SPS-80T |
| Light Sources | CIE D65 (6500 K, Ra >96) & Illuminant A (2900 K, Ra = 100) |
| Viewing Surface | 1050 mm × 700 mm |
| Overall Dimensions | 1050 mm (L) × 800 mm (W) × 2100 mm (H) |
| Net Weight | 40 kg |
| Power Supply | AC 220 V, 50 Hz |
| Illumination Method | External top-down projection |
| Compliance | CIE No. 51, ISO 3664:2009, CY/T 3–91 |
| Features | Spectrally stable dual-lamp system, built-in lamp hour counter, tilt-adjustable diffuser hood, neutral gray interior (Munsell N5), standardized sample mounting board and hanging panel |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EL6000 |
| Light Source Type | Mercury-Metal Halide Arc Lamp |
| Illumination Mode | Epifluorescence External Illuminator |
| Cooling Method | Air-Cooled |
| Lamp Lifetime | ≥2000 h |
| Shutter Response Time | ≤6 ms |
| Weight (Illuminator Head) | 1.8 kg |
| Compatibility | Leica DM series upright/inverted microscopes, M series stereomicroscopes |
| Software Integration | Full support for Leica LAS X and LAS AF platforms |
| Optical Coupling | Liquid light guide (LLG) interface |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | KL300 LED |
| Light Source Type | High-Efficiency White LED |
| Illumination Method | Internal (Fiber-Optic Coupled) |
| Power Consumption | <12 W |
| LED Lifetime | ≥50,000 hours |
| Luminous Output | Equivalent to 30 W Halogen Lamp |
| Compatibility | Leica L2 & KL200 Series Accessories |
| Operating Temperature Range | 5–40 °C |
| Safety Class | IEC 61010-1, Class I, IP20 |
| Regulatory Compliance | CE, RoHS, UL/cUL Listed |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LED1, LED3, LED5, LED8 |
| Light Source Type | Solid-State LED |
| Illumination Mode | Epi-illumination (External) |
| Wavelength Range (LED1) | 380–650 nm (White + 4 Discrete Channels) |
| Compatibility | Leica DM2500, DM4 B Microscopes |
| Control Interface | Analog Knob + TTL Trigger |
| LED Pod Support | Yes |
| Regulatory Compliance | CE, RoHS, IEC 61000-6-3 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GY-DL310 |
| Light Source Type | Deuterium + Tungsten-Halogen Dual Broadband Source |
| Spectral Range | 200–2500 nm |
| Output Interface | SMA905 Fiber Coupling Port |
| Power Adjustment | Continuously Variable (Analog/Digital Control) |
| Compliance | CE-marked per EN 61000-6-3 & EN 61000-6-4 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GY-HL05 |
| Light Source Type | Tungsten-Halogen Lamp |
| Optical Output Power | 5 W |
| Fiber Coupling Interface | SMA 905 |
| Dimensions | Palm-Sized (≈65 × 45 × 32 mm) |
| Spectral Range | ~350–2500 nm (typical halogen continuum) |
| Operating Lifetime | ≥2000 h (at rated power, stable filament temperature) |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GY-J-Hg / GY-J-Xe |
| Light Source Type | Mercury-Argon Discharge Lamp (GY-J-Hg) & Continuous Xenon Arc Lamp (GY-J-Xe) |
| Spectral Range (GY-J-Hg) | 200–1100 nm |
| Spectral Range (GY-J-Xe) | 900–1900 nm |
| Fiber Interface | SMA905 |
| Compliance | Designed for ISO/IEC 17025-compliant wavelength calibration workflows |
| Intended Use | Primary and secondary wavelength calibration of spectrometers, monochromators, and optical spectrum analyzers |
| Brand | Lumi-Universe |
|---|---|
| Model | Qingluan |
| Wavelength Range | 100–200 nm |
| Output Power | 1 mW – 1 W |
| Pulse Duration | < 100 fs |
| Repetition Rate | 1–10 MHz |
| Beam Size (Output Aperture) | Ø3–5 mm (collimated, TEM₀₀-like) |
| Spatial Coherence | High (λ/10 wavefront error typical) |
| Tunability | Monochromatized & continuously tunable across range |
| Cooling | Active air/water hybrid |
| Vacuum Interface | CF-63 or DN40 ISO-KF flange |
| Dimensions | 885 × 420 × 233 mm |
| Weight | 55 kg |
| Compliance | CE, RoHS, EN 61000-6-3/-4 |
| Brand | LUQI |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GY-HL20 |
| Light Source Type | Tungsten-Halogen Lamp |
| Maximum Power | 20 W |
| Optical Interface | SMA905 Fiber Coupling Port |
| Spectral Stability | High (Typical Drift < ±0.5% over 1 hr at Constant Power) |
| Spectral Range | ~350–2500 nm (Continuum Emission) |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | JSIR350-4-AL-C-D5.8-0-0 |
| Spectral Range | 2–15 µm |
| Emitter Chip Size | 2.2 × 2.2 mm |
| Rated Power | 0.65 W |
| Membrane Temperature | 610 ± 30 °C (max. 850 °C) |
| Lifetime | >100,000 h |
| Recommended Drive Mode | Constant Power |
| Package | TO-39 Metal Can |
| Max. Housing Temperature | 185 °C |
| Illumination Type | External Illumination |
| Light Source Type | Infrared Blackbody Source |
| Brand | PerfectLight (Pufei Lai) |
|---|---|
| Origin | Beijing, China |
| Model | Microsolar 300 |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | External Irradiation |
| Total Optical Power | 50 W (Visible: 19.6 W, UV: 2.6 W) |
| Spectral Range | 320–780 nm (extendable to 2500 nm with optional optics) |
| Beam Divergence | Avg. 6° |
| Spot Diameter | 30–60 mm at working distance |
| Long-Term Stability | ≤±3% over 8 h (optical feedback controlled) |
| Lamp Lifetime | >1000 h (under standard photocatalytic operating conditions) |
| Lamp Power | 300 W (adjustable 150–300 W) |
| Operating Current | 21 A |
| Power Supply Ripple | 200 mVp-p |
| Control Modes | Constant-Current (Programmed) & Constant-Irradiance (Optically Feedback-Controlled) |
| Cooling | Hybrid Cu/Al heatsink with axial airflow, thermal sensor monitoring, and post-shutdown fan delay |
| Safety | Low-voltage lamp–power supply interface, overcurrent/overload cutoff, fan-failure protection |
| Patent | CN201320740323.5 (integrated xenon lamp thermal management) |
| Brand | Mightex |
|---|---|
| Origin | USA |
| Model | Polygon |
| Light Source Compatibility | Xenon, Mercury, LED, and Other Broadband or Monochromatic Sources |
| Core Technology | Digital Micromirror Device (DMD)-Based Spatial Light Modulation |
| Max Pattern Switching Rate | ≥1 kHz |
| Spatial Resolution | Subcellular (≤1 µm at 100× objective) |
| Field of View Coverage | Full microscope FOV (up to 2.5 mm × 2.5 mm at intermediate image plane) |
| Multi-ROI Capability | Simultaneous independent illumination of ≥100 user-defined regions |
| Wavelength Flexibility | 350–750 nm (dependent on illumination source and optical path) |
| Synchronization Interface | TTL input/output, USB 2.0, and optional Ethernet for precise hardware triggering |
| Microscope Compatibility | Universal (integrated via C-mount, infinity-corrected tube lens, or epifluorescence port on upright/inverted systems) |
| Compliance | CE, RoHS, FDA-compliant design for research use only (not for clinical diagnostics) |
| Brand | NewOpto |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LLS-LEDs |
| Light Source Type | Solid-State LED |
| Illumination Mode | External Illumination |
| Connector Type | SMA 905 |
| Wavelength Range | 240 nm – 2100 nm |
| Spectral Options | UV, Visible, NIR, Broadband White (3000K–6500K CCT) |
| Coupling | FC/PC or SMA fiber-coupled output |
| Compliance | RoHS-compliant construction, CE-marked for laboratory use |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NewOpto LS-1 / LS-2 |
| Price | Available Upon Request |
| Brand | NewOpto |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantas Q1-1053 / Q2-1053 |
| Light Source Type | Infrared Pulsed Solid-State Laser |
| Illumination Mode | External Illumination |
| Wavelength | 1053 nm (1047 nm optional) |
| Fundamental Output Energy | 5–70 mJ |
| Harmonic Outputs | 527 nm (2–35 mJ), 351 nm (1–20 mJ), 263 nm (0.6–11 mJ), 211 nm (0.15–3.5 mJ) |
| Repetition Rate | 10 Hz (factory-fixed) |
| Pulse Width | < 8 ns |
| Pulse-to-Pulse Energy Stability | < 1 % rms (Q1), < 0.7 % rms (Q2) |
| Power Drift | ±3% |
| Beam Profile | Near TEM₀₀, >75% Gaussian |
| Beam Divergence | < 3 mrad (Q1A) to < 1.5 mrad (Q1C/Q1D) |
| Beam Diameter | 1.2–3.0 mm |
| Polarization | Linear, horizontal |
| Optical Jitter | < 1 ns rms |
| Laser Head Dimensions | 113 × 230 × 112 mm (Q1), 113 × 400 × 112 mm (Q2-1053) |
| Harmonic Generator | 113 × 242 × 112 mm |
| Controller Unit | 85 × 165 × 50 mm |
| Power Adapter | 50 × 125 × 32 mm |
| Operating Environment | 15–30°C, 10–80% RH (non-condensing), 90–230 VAC, 30 W, 47–63 Hz |
| Brand | NewOpto |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Tunable External-Cavity Diode Laser (ECDL) |
| Light Source Type | Tunable Single-Frequency Semiconductor Laser |
| Illumination Mode | External Illumination |
| Wavelength Options | 780 nm, 852 nm |
| Output Power | Up to 30 mW (diode-dependent) |
| Linewidth (FWHM) | Typically <150 kHz |
| Tuning Range | Typical 10 nm per diode configuration |
| Tuning Mechanism | Cat’s-eye retroreflector + ultra-narrowband interference filter (replacing alignment-sensitive diffraction gratings) |
| Brand | NewOpto |
|---|---|
| Origin | Zhejiang, China |
| Model | NewOpto-LEDs |
| Wavelength Range | 225–350 nm |
| Output Power Options | 1–3 mW, 3–5 mW, 10–15 mW, 30–50 mW |
| Emission Window Types | Flat or Hemispherical |
| Spectral FWHM | 12 nm (255 nm), ±5 nm (255–315 nm), ±10 nm (330–350 nm) |
| Package Formats | TO-39, TO-3, LCC |
| Drive Current | 80–900 mA |
| Illumination Mode | External (free-space) |
| Optional Accessories | Constant-current drivers (UVCLEAN-PS-DC-C), pulsed power supplies (UVCLEANPPS1μs/1A, UVCLEANPPS10ns/5.5A), SMA-fiber-coupled and pigtail configurations |
| Multi-wavelength Modules | 8-channel (TO-3), 12-channel (TO-5), 24-channel (LCC) |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Light Source Type | Mid-Infrared (MIR) Thermal Source |
| Wavelength Range | 1.2–8.0 µm |
| Output Power in ≥500 µm Fiber | >5 mW |
| Power Stability | ±0.5% (over time) |
| Lifetime | 5,000 hours |
| Cooling | Active Thermoelectric Cooling |
| Fiber Coupling | Standard FC/PC or SMA-compatible |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | None (standalone analog/digital control via TTL or 0–10 V input) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HG-2 Calibration Light Source |
| Light Source Type | Low-Pressure Mercury Vapor Lamp |
| Illumination Mode | Internal Illumination Configuration |
| Dimensions | 12.6 × 7.0 × 2.6 cm |
| Weight | 180 g |
| Power Consumption | ≤2 A at 5 VDC (external supply or embedded Li-ion battery charging mode) |
| Battery | Rechargeable, integrated lithium-ion |
| Lamp Lifetime | 3,500 hours (typical) |
| Aperture Diameter | 3 mm |
| Amplitude Stability | <±0.5% over 60 s (after thermal stabilization) |
| Fiber Connector | SMA 905 |
| Spectral Range | 170–1700 nm (HG-2 variant) |