Light Source Xenon Lamp Mercury Lamp
Filter
Showing 181–210 of 384 results
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | X2D2 |
| Light Source Type | Continuous-wave Deuterium Arc Lamp |
| Illumination Mode | External Irradiation Configuration |
| Radiant Output Stability | <0.5% RMS over 8 hours |
| Typical Lifetime | ≥2,000 hours at rated current |
| Spectral Range | 190–400 nm (UV-Vis continuum) |
| UV Output Power (at 220 nm) | ≥1.2 mW/nm (collimated, 1 mrad divergence) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | L-Series |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | External Irradiation |
| Spectral Range | 185 nm – 2000 nm (model-dependent, down to 220 nm or 240 nm with optional filtering) |
| Typical Power Ratings | 35 W, 75 W, 100 W, 150 W, 200–500 W |
| Lamp Architecture | Short-Arc or Long-Life Sealed-Quartz Envelope |
| Electrode Design | High-Performance Tungsten-Thoriated Cathode |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HCL Series |
| Pricing | Available Upon Request |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Distributor |
| Product Origin | Domestic |
| Model | HANUO-V |
| Price | USD 5,300 (approx.) |
| Light Source Type | Xenon Lamp |
| Illumination Mode | External Irradiation |
| Lamp Compatibility | Xenon, Mercury, Metal Halide |
| Power Adjustment Range (Xenon/Mercury) | 100–1000 W (continuous) |
| Power Adjustment Range (Metal Halide) | 100–450 W (continuous) |
| Quartz Reactor Vessels | 30 mL & 50 mL (16 pcs total, 8 each) |
| Sample Capacity | Up to 8 parallel reactors |
| Stirring | 8-channel magnetic stirring with independent speed control |
| Cooling System | Integrated recirculating chiller (cooling capacity >1000 W, casters + drain valve) |
| Quartz Cold Finger | 1 unit |
| Reaction Chamber | Light-tight dark box |
| Mobility | Equipped with mobile cart |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HANUO-ZH |
| Price | USD 6,800 (FOB Shanghai) |
| Light Source Type | Xenon Lamp |
| Irradiation Mode | Internal Illumination |
| Adjustable Power Range (Xenon) | 100–1000 W |
| Adjustable Power Range (Mercury) | 100–1000 W |
| Adjustable Power Range (Metal Halide) | 100–450 W |
| Cooling Capacity (Circulating Chiller) | >1000 W |
| Sample Capacity (Parallel Mode) | 8 positions |
| Tube Volume Options | 30 mL & 50 mL quartz |
| Reactor Vessel Options | 250 mL / 500 mL / 1000 mL borosilicate glass |
| Stirring | Dual-mode magnetic stirring (8-channel synchronized + high-torque single-vessel) |
| Quartz Cold Finger | Included |
| Compliance | Designed for ISO/IEC 17025-compliant photochemical laboratories |
| Software Interface | RS-485 + analog 0–5 V control output (no embedded GUI) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | HELIOS |
| Price Range | USD 14,000 – 21,000 (FOB) |
| Light Source Type | Broadband Xenon-Arc-Based Integrating Sphere Source |
| Illumination Mode | External Illumination Configuration |
| Spectral Range | 350–2500 nm (Standard Configuration) |
| Uniformity | ≥98% over Target Area |
| Stability | ≤0.5% RMS over 8 hours |
| Control Interface | Ethernet + RS-232 |
| Software Compatibility | LabVIEW™ API, SCPI Command Set |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Lamp Type | Xenon Arc Lamp |
| Power Rating | 150 W |
| Lifetime | ≥1,000 hours |
| Compatible Models | F-4500, F-2700, F-4600, F-7000 |
| Mounting Configuration | Internal Illumination (In-Spectrometer Housing) |
| Part Number | 250-1600 |
| Import Status | Genuine Imported Component |
| Brand | Lumi-Universe |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Honghu |
| Light Source Type | High-Harmonic Generation (HHG) Laser Source |
| Illumination Mode | Internal Illumination |
| Wavelength Range | 1–10 nm |
| Output Harmonic Energy | 1 nW – 1 µW |
| Pulse Duration | < 1 fs |
| Repetition Rate | 1–10 kHz |
| Dimensions | 855 mm × 420 mm × 233 mm |
| Weight | 55 kg |
| Brand | Ushio |
|---|---|
| Origin | Japan |
| Model | U-150W |
| Light Source Type | Xenon Lamp |
| Illumination Mode | Internal Illumination |
| OEM Compatibility | Horiba JY FluoroMax-4 |
| Brand | TOP (Tianjin) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GY-7 |
| Light Source Type | Atomic Emission Hydrogen Lamp |
| Illumination Mode | External Illumination Configuration |
| Spectral Output | Primary Balmer Series Lines (Hα: 656.3 nm, Hβ: 486.1 nm, Hγ: 434.0 nm, Hδ: 410.2 nm) |
| Operating Voltage | 5–12 V DC (typical) |
| Filament/Discharge Type | Low-pressure DC gas discharge lamp |
| Lifetime | ≥ 1,000 hours (under rated operating conditions) |
| Cooling | Passive air-cooled housing |
| Mounting | Standard M27×1 or SMA-compatible optical flange |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | HL100 |
| Pricing | Available Upon Request |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | iDH2000 |
| Light Source Type | Combined Deuterium & Tungsten-Halogen |
| Illumination Mode | Internal Illumination |
| Spectral Range | 215–2500 nm (continuous, gap-free) |
| Deuterium Lamp Lifetime | Up to 2000 h |
| Tungsten-Halogen Lamp Lifetime | Up to 6000 h |
| Output Stability | ±0.5% RMS over 8 h (after thermal stabilization) |
| Shutter | Motorized, TTL-triggerable |
| Halogen Intensity Control | 10-step electronic attenuation |
| Compatibility | Fiber-coupled output (SMA905), optimized for PG2000Pro and NOVA series spectrometers |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ISS-2 |
| Light Source Type | Tungsten-Halogen Lamp |
| Illumination Geometry | Internal (In-Cuvette) |
| Optical Path Length | 1 cm |
| Collimating Lens | 5 mm Ø, f/2, BK7 glass, f = 10 mm, SMA 905 connector |
| Filter Holder | Accepts filters up to 6.35 mm (1/4") thick |
| Base Material | Aluminum |
| Spectral Range | 360 nm – 2000 nm |
| Dimensions (L×W×H) | 155.0 × 50.0 × 53.3 mm |
| Input Power | 12 VDC / 800 mA (operating range: 7–20 VDC / 0.5–2 A) |
| Lamp Power | 5 V / 1.3 A |
| Output Power | 6.5 W |
| Lamp Lifetime | 900 h |
| Warm-up Time to Stability | ~30 min |
| Voltage Regulation Accuracy | ±0.2% |
| Cooling | Integrated axial fan beneath lamp assembly |
| Positioning Mechanism | Spring-loaded spherical screw for precise 1 cm cuvette alignment |
| Brand | ISTEQ |
|---|---|
| Origin | Netherlands |
| Model | XWS-30 |
| Spectral Range | 190–2500 nm (UV version) |
| Spectral Radiance | ~40 mW/(mm²·sr·nm) |
| Spatial Output Power | ~1.5 W |
| Fiber-Coupled Output Power | ~0.4 W |
| Emitter Size | 100 × 200 µm |
| Lifetime | 10,000 hours |
| Stability (STD) | <0.15% |
| Numerical Aperture | 0.5–0.55 (adjustable) |
| Dimensions (L×W×H) | 110 × 110 × 120 mm |
| Weight | 2 kg |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Cooling | Air-cooled |
| Purge Gas | High-purity N₂ or Ar (≥ Class 6), flow rate 1 L/min |
| Output Interfaces | C-mount, Thorlabs SM1, 30 mm cage system |
| Control Interface | USB-RS485 |
| Brand | ISTEQ |
|---|---|
| Origin | Netherlands |
| Model | XWS-65 |
| Light Source Type | Laser-Pumped Plasma |
| Spectral Range | 190–2500 nm (UV-VIS-NIR) |
| Spectral Radiance | ~50 mW/(mm²·sr·nm) |
| Output Power (Free-Space) | ~3 W |
| Output Power (Fiber-Coupled) | ~0.5 W |
| Plasma Emission Size | 250 × 500 µm |
| Stability (STD) | <0.15% |
| Lifetime | 10,000 h |
| Numerical Aperture | Adjustable 0.4–0.55 |
| Cooling | Air or Water (Lamp & Controller) |
| Input Power | 100–240 V, 50/60 Hz |
| Purge Gas | N₂ or Ar, ≥Grade 6, 1 L/min |
| Lamp Housing Dimensions | 130 × 110 × 74 mm, 1.3 kg |
| Controller Dimensions | 351 × 172 × 232 mm, 8 kg |
| Output Interfaces | C-mount, Thorlabs SM1, 30 mm cage system |
| Fiber Coupling | SMA or FC (FCU version only) |
| Optional Configurations | UV-optimized (190–2500 nm) or OFR-optimized (250–2500 nm), free-space or fiber-coupled output |
| Brand | ISTEQ |
|---|---|
| Origin | Netherlands |
| Model | XWS-X |
| Spectral Range | 190–2500 nm (UV), 250–2500 nm (OFR) |
| Spectral Radiance | ~120 mW/(mm²·sr·nm) |
| Spatial Output Power | ~3 W |
| Fiber-Coupled Output Power | ~0.6 W |
| Emitter Size | 250 × 500 µm |
| Lifetime | 10,000 h |
| Stability (STD) | <0.15% |
| Numerical Aperture | Adjustable 0.4–0.55 |
| Cooling | Air or Water (lamp housing & controller) |
| Input Power | 100–240 V, 50/60 Hz |
| Purge Gas | Grade 6+ N₂ or Ar, 1 L/min |
| Housing Dimensions (Lamp) | 130 × 110 × 74 mm, 1.8 kg |
| Controller Dimensions | 351 × 172 × 232 mm, 8 kg |
| Output Interfaces | C-mount, Thorlabs SM1, 30 mm cage (free-space) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Modulight |
| Light Source Type | Infrared-capable LED-based modular light source |
| Illumination Mode | External illumination |
| Spectral Output | 7 standard channels (460–740 nm + 5500K white) + 4 optional channels (365 nm, 400 nm, 4000K natural white, 3100K warm white) |
| Intensity Control | Software-controlled DC or sinusoidally modulated (10 µHz – 2 MHz) |
| Compliance | Designed for integration with Ivium electrochemical workstations (e.g., Stat, Vertex, CompactStat series) and compatible with ISO/IEC 17025-aligned electro-optical testing workflows |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BSZ-8 |
| Light Source Type | Mercury Lamp |
| Irradiation Mode | Internal Illumination |
| Sample Capacity | 8 positions |
| Quartz Reaction Tube Options | 30 mL or 50 mL (customizable up to 200 mL) |
| Quartz Cold Finger Dimensions | Φ70 × 380 mm |
| Stirring Speed Range | 0–1800 rpm (continuously adjustable) |
| Rotation Cycle per Tube | 1 s – 24 h (continuously adjustable) |
| Filter Configuration | 16 standard optical filters + 2 dedicated 8-position filter holders |
| Light Incidence Geometry | Perpendicular transmission through filters |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | GHX-IV |
| Light Source Type | Mercury Lamp |
| Irradiation Mode | Internal Illumination |
| Power Range | 100–1200 W (continuously adjustable) |
| Lamp Options | Mercury (300/500/1000 W), Xenon (300/500/1000 W), Metal Halide (500 W) |
| Sample Capacity | 8 parallel positions |
| Reaction Vessel Options | 250 / 500 / 1000 / 2000 / 3000 mL glass reactors |
| Quartz Tube Options | 30 mL or 50 mL |
| Filter Configuration | 16 UV/optical bandpass filters, dual 8-position filter holders |
| Cooling | Dual-layer quartz cold well (Φ70 × 380 mm), low-temperature circulating chiller (–20 °C to 100 °C, >1000 W cooling capacity) |
| Stirring | Magnetic stirring, 0–1800 rpm (8-channel synchronized), temperature control up to 300 °C |
| Timer | 0–999 min (digital microprocessor controller) |
| Safety | Radiation-shielded dark chamber with UV-blocking insertable shutter, hinged observation window, ventilation ports, and integrated cooling fan |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | GHX-V |
| Light Source Type | Mercury Lamp |
| Irradiation Mode | Internal Illumination |
| Power Control Range | 100–1200 W (continuously adjustable) |
| Lamp Options | 300/500/1000 W Mercury Lamp (selectable), 300/500/1000 W Xenon Lamp (selectable), 500 W Metal Halide Lamp |
| Sample Capacity | 8 parallel positions |
| Quartz Tube Volume | 30 mL or 50 mL (customizable) |
| Quartz Cold Finger | Φ70 × 380 mm |
| Reaction Vessel Options | 250 / 500 / 1000 / 2000 / 3000 mL |
| Filter Wheel | 16-position, dual 8-slot filter holder |
| Filter Transmission Geometry | Perpendicular incidence |
| Stirring Speed (per tube) | 0–1800 rpm (stepless) |
| Rotation Period per Tube | 0–9999 s (stepless) |
| Magnetic Stirrer Temp. Range | Ambient to 300 °C |
| Timer Range | Up to 999 min |
| Cryogenic Circulator | Cooling Capacity >1000 W, Temp. Control Range: −20 to 100 °C |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | FLE1001 |
| Light Source Type | Deuterium–Tungsten Hybrid Source |
| Illumination Mode | External Illumination |
| Wavelength Range | 190–1100 nm |
| Output Power | 10 W (Deuterium), 10 W (Tungsten) |
| Intensity Stability | ±0.3% over 30 min |
| Lamp Lifetime | >1000 h |
| Optical Interface | SMA905 |
| Warm-up Time | 20 min |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Origin | Domestic (China) |
| Model | FLQ1004 |
| Light Source Type | Broadband Continuous Arc Lamp (Configurable for Xenon or Mercury Short-Arc Lamps) |
| Illumination Mode | External Illumination (Collimated or Diffuse Beam Delivery) |
| Integrating Sphere Diameter Options | 200 mm, 300 mm, 500 mm (Custom Diameters Available) |
| Control Interface | RS-232 / USB / Ethernet (via Integrated Controller) |
| Attenuation Mechanism | Motorized Iris Aperture + Motorized Neutral Density Filter Wheel + Electronic Shutter |
| Software Control | Windows-Based GUI with Real-Time Intensity Calibration & Log Data Export |
| Brand | Keopsys |
|---|---|
| Origin | France |
| Model | PUFL |
| Wavelength | 355 nm |
| Output Type | Free-space, collimated beam |
| Pulse Energy | up to 1.6 µJ |
| Peak Power | up to 1.6 kW |
| Average Power | up to 80 mW |
| Repetition Rate | 50 kHz |
| Beam Quality (M²) | < 1.3 |
| Power Consumption | Low |
| Package | Compact and rugged |
| Application Fields | Aerosol detection, fluorescence excitation, Raman spectroscopy, biological experimentation, wafer inspection |
| Brand | CHEMn (Distributor) |
|---|---|
| Origin | USA |
| Model | PR160 |
| Light Source Type | High-Precision Tunable LED Array |
| Illumination Mode | External Irradiation |
| Max Power | 40 W |
| Input Voltage | 100–240 V AC |
| Operating Temperature | 0–40 °C |
| Beam Angle | 56° |
| Peak Wavelength Options | 370 nm, 390 nm, 427 nm, 440 nm, 456 nm, 467 nm, 525 nm, 640 nm, 740 nm |
| Irradiance | 2.3 mW/mm² (measured at 1 cm distance) |
| Dimensions (H × D) | 114 mm × 63 mm |
| Spectral Accuracy | ±1 nm |
| Output Stability | ±3% over rated operating conditions |
| Brightness Control | 4-step discrete intensity adjustment |
| Mounting Compatibility | Universal lab clamp, dedicated PR160 adjustable stand |
| Brand | Labsphere |
|---|---|
| Model | ACR |
| Origin | Shanghai, China |
| Light Source Type | Tunable Integrating Sphere Source (Xenon/Mercury-Hybrid Capable) |
| Illumination Geometry | Internal Illumination |
| Color Temperature Range | 2000 K – 10000 K (CCT-adjustable) |
| Spectral Output | Programmable to CIE Standard Illuminants (A, D50, D65, D75, etc.) |
| Luminance Range | 0.01 – 100,000 cd/m² (adjustable) |
| Viewing Angles | 0°, 15°, 30°, 45° (symmetrical left/right ports |
| Detector Platform | Motorized Linear Rail with Sub-millimeter Positioning Accuracy |
| Compliance Standards | ICDM, VESA DisplayHDR™, NIST IR 6738, ISO 9241-307, CIE S 023/E:2022 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Blue Sun |
| Light Source Type | Xenon-based broadband solar simulator |
| Illumination Mode | External illumination |
| Spectral Range | 400–2500 nm |
| Output Stability | <0.5% RMS over 8 hours |
| Spectral Smoothness | <1.5% spectral gradient in visible range |
| Calibration Interval | ≥12 months (under recommended operating conditions) |
| Lifetime | ≥2000 hours (xenon arc lamp, typical) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-D Series |
| Light Source Type | Tungsten-Halogen |
| CCT | 3000K ± 50K |
| Exit Port Diameter | 2", 4", or 8" |
| Max Luminance | Up to 80,000 cd/m² |
| Exit Port Illuminance | Up to 251,200 lux |
| Angular Uniformity (FOV) | ±2.0% within ±35° |
| Internal Coating | Spectraflect or Spectralon |
| Variable Attenuator Options | Advanced VAA-220A (2.00E+06 steps), Dynamic VAD-012/VAD-021 (2.40E+04–4.80E+04 steps), Manual VA-MM (2.00E+04–4.00E+04 steps) |
| Dynamic Range | Up to 160 dB (26-bit equivalent) |
| Software Interface | HELIOSense GUI with LSAPI support |
| Compliance | Designed for ASTM E308, ISO/CIE colorimetry standards, and GLP/GMP-aligned calibration traceability |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-LL Series |
| Light Source Type | Tungsten-Halogen |
| CCT | 2856 K ±50 K |
| Spectral Distribution | Blackbody-like |
| Integrating Sphere Coating | Spectraflect or Spectralon |
| Output Port Diameter | 2–8 in (0.05–0.2 m) |
| Sphere Diameter | 7.5–20 in (0.19–0.5 m) |
| Max Luminance | 1,600–9,500 cd/m² |
| Illuminance at Port | 5,000–30,000 lux |
| Dynamic Range | 4.00E+09 to 1.00E+10 (31–32 bits, 196–199 dB) |
| Angular Uniformity (FOV ±35°) | ±2.0% |
| Attenuation System | Advanced Variable Attenuator (VAA), 6.00E+06 to 8.80E+06 steps |
| Detector Configuration | Dual Silicon Detectors (SD-S1 & SD-L1) |
| Software Interface | HELIOSense GUI with LSAPI support |
| Compliance | MIL-STD-810G, ISO/IEC 17025 traceable calibration options available |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-Plus AMA |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | Internal Illumination |
| CCT Range | 3000 K to 6000 K |
| Spectral Range (Standard) | 350–1000 nm |
| Spectral Range (UV-Optimized) | 200–850 nm |
| Opening Diameter | 4 in or 8 in |
| Max Luminance | Up to 47,300 cd/m² |
| Opening Illuminance | Up to 182,000 lux |
| Field of View Uniformity | ±2.0% over 35° |
| Attenuation Options | Advanced Variable Attenuator (VAA), Dynamic Variable Attenuator (VAD), Manual Micrometer Attenuator (VA-MM) |
| Attenuator Resolution | Up to 2.00E+06 steps |
| Dynamic Range | Up to 152 dB |
| Integrated Spectroradiometer | Yes |
| Calibration Traceability | NIST-traceable |
| Compliance | ASTM E927, ISO 9050, MIL-STD-810G (optical testing), USP <1059>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | Labsphere |
|---|---|
| Model | Helios-V Series |
| Origin | USA |
| Light Source Type | Tungsten-Halogen (3000K Blackbody Simulated) |
| Integrating Sphere Diameter | 12 in |
| Output Port Diameter | 4 in (0.1 m) |
| Luminance Range | 0.001–11,500 cd/m² |
| Illuminance at Port | Up to 36,000 lux |
| CCT | 3000K ±50K |
| Spectral Range | 300–2400 nm |
| Uniformity (FOV 35°) | ±2.0% |
| Attenuation Method | Manual VA-MM or Dynamic VAD |
| Attenuator Steps | 1.00E+04 (NMNN) / 1.20E+04 (NDNN) |
| Dynamic Range | 5.00E+04 (93 dB, 16-bit) / 1.20E+04 (81 dB, 14-bit) |
| Internal Coating | Spectraflect® |
| Compliance | ASTM E308, ISO/CIE 11664, NIST-traceable calibration options available |
| Software Interface | HELIOSense™ via Labsphere LSAPI |