- All
- Favorite
- Popular
- Most rated
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | S-Series |
| Max Temperature | 200 °C / 300 °C (selectable by variant) |
| Chamber Volume | 60–380 L |
| External Dimensions (W×H×D) | 1050×1350×950 mm to 1400×1750×1200 mm |
| Internal Dimensions (W×H×D) | 450×300×450 mm to 800×800×600 mm |
| Power Input | 2–6 kW |
| Voltage | 230 V or 380 V (3-phase) |
| Weight | 60–350 kg |
| Air Circulation | Horizontal forced convection via side-mounted axial fan (S60/S100) or central radial fan (S250/S400) |
| Temperature Control | INDUSTRY PID programmable controller with 30 stored profiles (15 steps each), real-time clock, RS485/RS232 interface option |
| Safety | Door-mounted safety switch, K-type thermocouple, semiconductor non-contact SSR relay, independent current-limiting unit |
| Construction | Mild steel frame & outer casing |
| Ventilation | Manually adjustable damper with bottom exhaust |
| Compliance | Designed to meet DIN 17052-1 Class A uniformity requirements for laboratory ovens |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | PK Series |
| Max Temperature | 1280 °C |
| Chamber Volume | 10–40 L |
| External Dimensions (W×H×D) | 700×700×790 mm to 1100×1440×1900 mm |
| Internal Dimensions (W×H×D) | 230×200×350 mm to 290×250×550 mm |
| Power Input | 3–11 kW |
| Weight | 60–320 kg |
| Voltage | 230 V or 400 V (3-phase) |
| Heating Configuration | Dual-zone (side + bottom) |
| Temperature Uniformity | Compliant with DIN 17052-1 Class A |
| Control System | INDUSTRY PID Controller with 30 programmable profiles (15 steps each), real-time clock, non-contact semiconductor relay |
| Thermocouple | Type S (Platinum/Rhodium) |
| Insulation | Lightweight refractory brick |
| Structural Frame | Low-carbon steel |
| Door | Manually operated, safety interlock switch |
| Optional Atmosphere | Semi-sealed design compatible with protective gas kits |
| Brand | LAC (Czech Republic) |
|---|---|
| Model | KC Series |
| Type | Box-Type Muffle Furnace |
| Max Temp | 1300 °C / 1400 °C |
| Chamber Volume | 20–120 L |
| Power | 8–18 kW |
| Voltage | 380 V AC, 3-phase |
| External Dimensions (W×H×D) | 760×1250×850 mm to 1080×1480×1120 mm |
| Internal Dimensions (W×H×D) | 270×270×270 mm to 500×500×500 mm |
| Insulation Thickness | 30–40 mm mineral fiber + firebrick lining |
| Heating Element | Kanthal A1 wire wound on ceramic tubes, mounted on refractory brick supports, distributed across five surfaces (four walls + floor) |
| Temperature Sensor | Type S thermocouple |
| Controller | CERAMIC programmable controller (20 programs × 15 segments), real-time clock, SSR output |
| Safety | Door-mounted interlock switch, overpressure relief valve (optional), independent thermal cut-off unit |
| Compliance | Designed for GLP-compliant thermal processing |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PULSAR-60 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid and Liquid Samples |
| Sensitivity | SNR ≥ 100:1 at 2.6 ppm for 1% ethylbenzene (single scan) |
| Resolution | 0.5 Hz (0.0083 ppm) |
| Operating Frequency | 60 MHz (1.4 T permanent magnet) |
| Sample Tube | Standard 5 mm OD NMR tube |
| Cryogen-Free Operation | Yes (permanent magnet, no liquid nitrogen or helium required) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KR-30/12 |
| Max Temp | 1200 °C |
| Chamber Volume | 3 L |
| External Dimensions (W×H×D) | 1100×1600×2100 mm |
| Internal Dimensions (W×H×D) | 310×310×310 mm |
| Power Rating | 3.5 kW |
| Net Weight | 155 kg |
| Voltage | 230 V AC, Single-phase |
| Temperature Control | Programmable PID via INDUSTRY controller with real-time clock |
| Programs | 30 stored profiles, up to 15 segments per program |
| Thermocouple Type | S-type (Pt/Pt–10% Rh) |
| Heating Element | Embedded resistance wire in refractory grooves |
| Insulation | Lightweight firebrick + ceramic fiber + calcium silicate board |
| Evaporator Drive | PLC-controlled rotary–translational mechanism |
| Optional Accessories | HT-100 multi-point temperature monitor (10 channels), RS232/RS485 interface, PC-based cycle logging software |
| Brand | LAC |
|---|---|
| Model | LH Series |
| Temperature Range | Up to 1340 °C |
| Internal Volume | 6–30 L |
| Power Supply | 230 V AC, Single-Phase |
| Control System | HT40A Programmable Temperature Controller |
| Heating Element | Kanthal A1 Wire Wound on Mullite Tubes |
| Thermocouple | Type S (Platinum/Rhodium), Rear-Mounted |
| Insulation | High-Density Refractory Ceramic Fiber |
| Door Mechanism | Spring-Loaded Top-Hinged with Safety Interlock |
| Cooling | Integrated Axial Fan for Rapid Cool-Down |
| Compliance | Designed for GLP-compliant thermal processing in non-corrosive atmospheres |
| Brand | MagQu |
|---|---|
| Origin | Taiwan |
| Model | XacQuan |
| Frequency Range | 10 Hz – 25 kHz |
| Output | Real (χ′) and Imaginary (χ″) Components of AC Susceptibility |
| Sample Volume | ≥ 0.1 mL |
| Measurement Time | < 60 s per sample |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | Windows-based GUI with real-time plotting and data export (CSV, TXT) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Low-Field NMR Analyser |
| Model | MQC-2, MQC-5, MQC-23, MQC-F |
| Operating Frequency (¹H) | 2 MHz, 5 MHz, 23 MHz |
| Operating Frequency (¹⁹F) | 19 MHz |
| Sample Tube Diameters | 5–51 mm (model-dependent) |
| Compliance | ASTM, ISO 10565, ISO 10632, AOCS Cd 16b-93, ISO 82, IUPAC 2.150(a), IUPAC 2.323(a) |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Type | Box Furnace |
| Heating Method | Electric Resistance |
| Max Temperature | 650 °C or 850 °C (model-dependent) |
| Chamber Volume | 20–70 L |
| Internal Dimensions | 300×200×350 mm to 350×400×500 mm |
| External Dimensions | 800×650×1050 mm to 950×1550×1150 mm |
| Power Input | 3.0–9.0 kW |
| Voltage | 230 V or 380 V (3-phase) |
| Weight | 115–200 kg |
| Gas Circulation | Horizontal axial fan (rear-mounted) |
| Insulation | High-density ceramic fiber |
| Heating Elements | Side-mounted FeCrAl alloy wire |
| Temperature Control | INDUSTRY PID programmable controller (30 programs × 15 segments, real-time clock, ramp/soak functionality) |
| Sensor | K-type thermocouple |
| Output Switching | Solid-state non-contact relay |
| Compliance | DIN 17052-1 (temperature uniformity class), CE-marked |
| Standard Features | Stainless steel chamber & casing, mechanical latch door with safety interlock, manual damper, adjustable shelf, base stand |
| Optional | PC interface (RS485/USB), chart recorder, inert atmosphere kit, semi-hermetic design, motorized damper, left/up-swing door, single-hand door operation, overpressure cooling system |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | LMH Series |
| Max Temperature | 1200 °C |
| Chamber Volume | 4–11 L |
| External Dimensions (W×H×D) | 490×540×720 mm to 570×540×720 mm |
| Internal Dimensions (W×H×D) | 170×90×275 mm to 255×165×255 mm |
| Power Rating | 3–3.5 kW |
| Weight | 43–53 kg |
| Voltage | 230 V AC |
| Temperature Control | HT40 Programmable Controller with S-type Thermocouple |
| Heating Element | Kanthal A1 wire wound on mullite tubes |
| Insulation | Mullite fiber + mineral granulate fill |
| Safety Features | Interlocked door switch, tempered blue safety viewing window, spring-assisted counterbalanced door |
| Cooling | Integrated axial cooling fan |
| Compliance | Designed for GLP-compliant thermal processing in analytical and materials labs |
| Brand | Orton |
|---|---|
| Origin | USA |
| Equipment Type | Horizontal Tube Furnace |
| Model | GTF-MD Series |
| Maximum Temperature | 1600 °C |
| Gradient Zone Length | 12 in (300 mm) or 16 in (405 mm) |
| Gradient Options | 10 °C/in or 20 °C/in |
| Corresponding ΔT Across Gradient Zone | 120 °C, 160 °C, 240 °C, or 320 °C |
| Compliance | ASTM C829A & C829B |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | High-Temperature Viscometer |
| Model | BBV 1000 Series |
| Temperature Range | Up to 1000°C / 1200°C / 1600°C (configurable) |
| Control Method | PID-controlled programmable heating |
| Standards Compliance | ASTM C-598 (Annealing & Strain Point), ASTM C-1350M (Viscosity vs. Temperature) |
| Viscosity Range | 10⁹–10¹⁴ P (Poise) |
| Sample Span | Standard 50 mm (customizable) |
| Sample Cross-Section | 2.5–5.0 mm diameter rod |
| Measurement Principle | Beam bending deflection under constant load at elevated temperature |
| Detection | LVDT-based real-time deformation monitoring |
| Accuracy | ±1 °C for annealing/strain point determination on geometrically regular glass rods |
| Software | Orton proprietary control, acquisition, and analysis suite with automated reporting |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | RSV-1600, RSV-1700 |
| Viscosity Range | 10–3×10⁵ Poise |
| Max Operating Temperature | 1600 °C or 1700 °C |
| Compliance | ASTM C-965 (Method A), ASTM C-1276, ISO 7884-2 |
| Measurement Principle | Constant Angular Velocity (Couette Flow) |
| Sample Environment Options | Air, Vacuum, Inert Gas (N₂, Ar) |
| Crucible Capacity | 20–1000 g |
| Rotor & Crucible Materials | Pt/Rh alloy, Alumina, Graphite |
| Control System | PID Programmable Temperature Controller with Over-Temp Protection |
| Data Acquisition | Real-time torque, viscosity, temperature logging via VISCO software |
| Calibration Traceability | NIST SRM 717A certified reference glass |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PULSAR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid and Liquid Samples |
| Sensitivity | SNR = 25:1 at 2.6 ppm for 1% ethylbenzene, single-scan |
| Resolution | 1.8 Hz (0.03 ppm) |
| Operating Frequency | 60 MHz |
| Magnet Type | Permanent Magnet |
| Cryogen-Free Operation | Yes |
| Brand | LAC |
|---|---|
| Origin | Czech Republic |
| Model | L-Series (L 03/12, L 05/12, L 09/12, L 15/12) |
| Max Temperature | 1200 °C |
| Internal Volume | 3–15 L |
| Power | 1.2–3.5 kW |
| Voltage | 230 V AC |
| Weight | 21–39 kg |
| External Dimensions (W×H×D) | 380×440×400 mm to 450×505×600 mm |
| Internal Dimensions (W×H×D) | 180×100×140 mm to 250×170×340 mm |
| Temperature Controller | HT40A or INDUSTRY-series programmable controller |
| Heating Element | Embedded resistance wire in refractory insulation |
| Safety | Door-mounted interlock switch, no open flame |
| Compliance | Designed for GLP-compliant thermal processing in R&D and QC labs |
| Brand | Specac |
|---|---|
| Origin | United Kingdom |
| Model | Atlas |
| Max Operating Temperature | 300 °C or 400 °C |
| Adjustable Film Thickness | 15, 25, 50, 100, 250, 500 µm |
| Sample Diameter | 29 mm |
| Configuration Options | Standalone press unit (15631/15800) or integrated press + manual 15-ton hydraulic press (15633/15810) |
| Compliance | Designed for ASTM E1252, ISO 18381, and USP <1118> FTIR sample preparation |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | PPV-1000/1200/1600 Series |
| Max Operating Temperature | 1600 °C |
| Viscosity Range | 10⁵–10⁹ Poise |
| Compliance | ASTM C1351M |
| Control Interface | RS-232 or USB |
| Load Application | Adjustable dead-weight system with triple-mass configuration |
| Displacement Sensing | LVDT (±2.5 mm full scale) |
| Sample Geometry | 44 mm diameter × ~1.5–3 mm thick glass disc |
| Heating System | Vertical tube furnace with sintered alumina or fused quartz support structure |
| Temperature Sensing | “S”-type thermocouple positioned adjacent to sample |
| Sample Fixturing | Dual 44 mm × 6 mm high-temperature alloy plates with 40 mm × 0.001″ platinum foil interlayers |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry BL4 3K |
| Cooling Base Temperature | <3 K |
| Operating Temperature Range | <3 K to 300 K |
| Optical Numerical Aperture | f/1 |
| Sample Vibration Amplitude | <10 µm |
| Vacuum System | Oil-Free Mechanical Pump Compatible (with Activated Carbon Getter) |
| Sample Exchange | Side-Access Port with Quick-Release Mechanism |
| Optional Features | Low-Vibration Mounting Stand, Rotatable Sample Stage (±5°), Electrical Feedthroughs, Interchangeable Optical Windows (CaF₂, Si, Quartz, Sapphire) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | SP900D / SP1000D |
| Temperature Range | Up to 900°C or 1000°C |
| Heating Rate Control | Programmable PID, 5°C/min standard per ASTM C338 |
| Sample Geometry | Glass fiber, Ø0.65 mm × 235 mm |
| Softening Detection Method | Laser-based axial elongation tracking at 1 mm/min under self-weight |
| Compliance | ASTM C338 (Littleton softening point) |
| Data Acquisition | Real-time PC software with automated calculation, statistical reporting, and audit-ready output |
| Accuracy | ±1°C (repeatability on identical fibers) |
| Software Features | Mode selection, heating profile customization, GLP-compliant data logging, export to CSV/PDF |
| Brand | Orton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-3A |
| Pricing | Upon Request |
| Max Temperature | 1000 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 25 °C/min |
| Probe Travel Range | 0–3 mm |
| Probe Resolution | 0.0025 mm |
| Brand | LAC (Czech Republic) |
|---|---|
| Model | PKR & PKRC Series |
| Max Operating Temperature | 1100 °C (PKR) / 900 °C (PKRC) |
| Chamber Volume | 24–230 L |
| External Dimensions (W×H×D) | 290×250×550 to 1800×1750×2350 mm |
| Internal Dimensions (W×H×D) | 350×1100×1310 mm (max) |
| Power Rating | 11–50 kW |
| Weight | 400–1380 kg |
| Voltage | 380 V AC, 3-phase |
| Heating Element | SiC-sheathed resistance wire (side & bottom), ceramic tube-wound |
| Atmosphere Control | Sealed chamber with inert gas (N₂, Ar, synthetic gas) inlet, water-cooled stainless steel flange, silicone rubber door seal, overpressure relief port |
| Thermal Insulation | Lightweight refractory brick |
| Temperature Control | INDUSTRY PID programmable controller (30 stored programs, 15 segments each, real-time clock, ramp/soak functionality) |
| Sensor | Type S thermocouple |
| Power Switching | Solid-state non-contact relay |
| Compliance | Designed per DIN 17052-1 Class A temperature uniformity requirements |
| Key | Brand: LAC |
|---|---|
| Model | VP Series |
| Max Temperature | 1600–1700 °C |
| Chamber Volume | 2–70 L |
| Power Supply | 230 V or 380 V AC |
| Heating Element | Kanthal Super |
| Thermocouple Type | B- and S-type |
| Control System | INDUSTRY PID Programmable Controller (30 programs × 15 steps, real-time clock) |
| Cooling | Integrated axial fan |
| Safety | Door-mounted safety interlock switch |
| Compliance | CE-marked, designed for GLP-compliant thermal processing environments |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | ANS800 Series |
| Max Operating Temperature | 800 °C or 1000 °C |
| Compliance | ASTM C336 |
| Temperature Control | PID-controlled, automated |
| Measurement Principle | LVDT-based fiber elongation monitoring under controlled cooling |
| Data Processing | Automated calculation of annealing point (AP) and strain point (SP) per ASTM C336 |
| Accuracy | ±1 °C (for glass fiber samples) |
| Software | Orton proprietary control & analysis suite with real-time plotting, statistical reporting, and audit-ready data logging |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL 2000 Series |
| Max Operating Temperature | 1000 °C (DIL 2010), 1200 °C (DIL 2020), 1600 °C (DIL 2030) |
| Low-Temp Capability | Down to –196 °C (with LN₂ cooling option, DIL 2010C) |
| Sample Dimensions | Up to 50 mm length × 20 mm diameter |
| Repeatability | ±0.004 PLC |
| Heating Rate | 1–30 °C/min |
| Temperature Resolution | 0.1 °C |
| Atmosphere Control | Optional inert/vacuum/oxidizing gas environments |
| Calibration Standards | Included (fused quartz, α-alumina, NIST-traceable reference materials) |