Optical Measurement Instruments
Filter
Showing 2071–2100 of 3895 results
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NKD8000 |
| Price | Upon Request |
| Spectral Range (Standard) | 350–1000 nm |
| Spectral Range (UV-Enhanced) | 280–1000 nm |
| Spectral Range (NIR) | 800–1700 nm |
| Spectral Range (Broadband) | 350–1700 nm |
| Spectral Range (Extended Broadband) | 350–2200 nm |
| Spectral Resolution | 1 nm or 2 nm (selectable) |
| Measurement Time | 2–10 minutes (dependent on spectral range and configuration) |
| Analysis Time | 5 seconds–5 minutes (dependent on model complexity) |
| Incident Angle Range | 20°–70° (motorized continuous variable), or fixed angles (30°/50°/70°) |
| Spot Size | 5 mm (standard), 250 µm (optional micro-spot) |
| Sample Stage | X-Y motorized scanning stage (100 mm travel), accommodates samples from 10×10 mm to 200×250 mm |
| Max. Layers | 5-layer stack with up to two unknown parameters per layer |
| Thickness Range | 1 nm – 25 µm (wavelength-, angle-, and polarization-dependent) |
| Accuracy (semi-absorbing films) | thickness <1% (typ.), <3% (max) |
| Accuracy (metallic films) | thickness <1% (typ.), <3% (max) |
| Repeatability | transmission <0.01% (typ.), <0.1% (max) |
| Light Source | 150 W xenon arc lamp (NKD8000v) |
| Power Supply | 220 V, 50 Hz, 2 A or 110 V, 60 Hz, 3 A |
| Dimensions | 890 × 540 × 720 mm |
| Weight | 105 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J200 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Accuracy | ±0.0002 (nD) |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Light Source | LED @ 589 nm |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detection Method | Linear CCD Array |
| Display | 7-inch TFT Color Touchscreen |
| Interface | USB & RS-232 |
| Power Supply | 220 VAC / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | J300 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Refractive Index Accuracy | ±0.0002 |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.03 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detection Method | Linear CCD Array |
| Display | 7-inch TFT Color Touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | J500 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00003 |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.02 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J600 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00002 |
| Brix Range | 0–100.00% |
| Brix Accuracy | ±0.01% |
| Temperature Control Range | 5–90 °C |
| Temperature Stability | ±0.01 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V AC / 50 Hz |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | P-2000 |
| Light Source | Sodium lamp (D-line, 589.3 nm), optional mercury lamp and halogen lamp |
| Temperature Control | Peltier-controlled sample holder |
| Display | Digital LCD with 0.0001° resolution |
| Measurement Range | ±90° |
| Measurement Accuracy | ±0.002° |
| Measurement Precision | 0.002° |
| Response Speed | 6°/s |
| Compliance | JP XVII, USP <781>, EP 2.2.7, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | C-Series (C203, C305, C308, C314, C605, C608, C614, C623, C908, C914, C923) / CS-Series (CS155, CS305, CS308, CS314, CS608, CS614, CS908, CS914) |
| Length Measurement Accuracy | (2.6 + L[mm]/200) µm (C-Series), (3.5 + L[mm]/100) µm (CS-Series) |
| Diameter Measurement Accuracy | (1.0 + D[mm]/200) µm (C-Series), (1.3 + D[mm]/100) µm (CS-Series) |
| Max Measurable Length | 250–900 mm |
| Max Measurable Diameter | 30–230 mm |
| Application Scope | Rotating shaft components requiring GD&T-compliant optical metrology |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W15 |
| Measurement Principle | Contact Stylus Profilometry (ISO 21920-compliant) |
| Max Measuring Length | 17.5 mm |
| Vertical Range/Resolution (T1E stylus) | ±100 µm / 6 nm |
| Traverse Speeds | 0.15, 0.5, 1 mm/s |
| Stylus Connection | USB & Bluetooth® |
| Compliant Standards | ISO 21920-1:2021, ISO 4287:2010, ISO 13565-2/-3, ISO 12085, ISO 4288, DIN EN 10049, JIS B 0601 |
| Evaluated Parameters | Ra, Rq, Rz, Rt, Rsk, Rku, Rk-family (Rpk, Rvk, Rk), Rmr, Rdc, RΔq, RSm, AR, Wte, and >40 additional profile & functional parameters |
| System Accuracy | ±5% (per ISO 21920-3 Annex B calibration protocol) |
| Optional Accessories | LV17 Wireless Drive Box, HS300 Height Stand, MS300 Compact Measurement Station |
| Software Platform | Evovis Mobile Standard (PC-based evaluation with statistical export, GLP/GMP-ready audit trail, CSV/PDF report generation) |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W40 |
| Maximum Measurement Length | 20 mm |
| Measurement Speed | 0.2–2 mm/s |
| Connection Interface | USB-C |
| Vertical Measurement Range/Resolution | ±300 µm / 1 nm |
| Compliance | DIN EN ISO 21920, DIN EN ISO 4287:2010, DIN EN ISO 13565-2 & -3, DIN EN ISO 12085, ISO 4287:1987, DIN 4762, DIN EN ISO 4288, JIS B-0601, DIN EN 10049 / SEP 1941 |
| Accuracy | ±5% |
| Evaluation Parameters | Ra, Rq, Rsk, Rku, Rt, Rz, Rk, Rpk, Rvk, Pk, Ppk, Pvk, Wt, Wa, Wq, and >100 additional profile and amplitude parameters per ISO standards |
| Software Platform | Evovis Mobile Standard |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W800 |
| Type | Contact Stylus-Based Surface Profilometer |
| Measurement Principle | Inductive Stylus Tracing with High-Resolution Position Feedback |
| Drive Mechanism | Motorized Bridge-Type Translation Stage |
| Probe Interface | Magnetic Quick-Change Mount with RFID-Enabled Stylus Recognition |
| Control | Integrated Handheld Control Box with Emergency Stop and Axis Resume Functionality |
| Compliance | Designed for ISO 4287, ISO 4288, ISO 25178-2, and ASME B46.1 Conformance |
| Software Platform | Jenoptik TopMap Suite (Supports GLP/GMP Audit Trail, FDA 21 CFR Part 11–Compliant User Management & Electronic Signatures) |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6800T |
| Product Type | Online Analyzer |
| Turbidity Range | 0.0–4.0 / 40.0 / 400.0 / 1000.0 NTU |
| SS Range | 0.0–10.0 / 100.0 / 1000.0 / 2000.0 mg/L |
| Resolution | 0.1 NTU, 0.1 mg/L |
| Operating Temperature | 0–60 °C |
| Accuracy | ±2% of full scale |
| Output | Dual 4–20 mA (turbidity & temperature), RS485 Modbus RTU |
| Enclosure Rating | IP65/NEMA 4X |
| Sensor Protection Rating | IP68 |
| Sensor Material | 316L stainless steel housing, custom optical glass |
| Sensor Dimensions | Ø42 mm × 210 mm L, 1" NPT male thread |
| Max Pressure | 4 bar |
| Cable Length | 10 m standard |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | specbos 1211 |
| Price Range | USD 13,500 – 27,000 (FOB Hamburg) |
| Spectral Range | 350–1000 nm (standard), optional 250–1000 nm (UV variant) |
| Spot Diameter | 4 mm (default), down to 0.5 mm with optional focusing lenses |
| Measurement Modes | Radiance, Luminance, Illuminance, Irradiance |
| Interface Options | USB 2.0, Bluetooth 4.2, Ethernet, RS-232 |
| Power Supply | Bus-powered via USB |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration available |
| Brand | AOE Tech |
|---|---|
| Model | JF-H410B |
| Wavelength | 650 nm |
| Output Power | 5 mW |
| Spectral Width | ±5 nm @ 20°C |
| Fiber Compatibility | SM & MM |
| Operating Mode | CW / 2 Hz Modulated |
| Connector Interface | 2.5 mm Universal Ferrule |
| Power Supply | 2 × AAA batteries |
| Continuous Operation Time | 20–30 h |
| Operating Temperature | −10°C to +60°C |
| Storage Temperature | −25°C to +70°C |
| Dimensions | 17.5 × 2.6 × 2.6 cm |
| Weight | 200 g |
| Brand | AOE Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JF-H430 |
| Price Range | USD 0–7,200 |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JFB-IB |
| Pricing | Upon Request |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Model | BRAUMEISTER |
| Measurement Principle | Multi-wavelength UV-Vis Spectrophotometry + Density/Refractometry Hybrid Analysis |
| Sample Throughput | ≤45 seconds per analysis |
| Parameter Coverage | Apparent Extract, Alcohol by Volume (ABV), Original/Real Extract, IBU, EBC Color, pH, FAN, Total Acidity, SO₂, Dissolved CO₂, Sugars (Glucose, Fructose, Total), Nitrogen Content, Caloric Value |
| Compliance | Designed for ISO 8587, ISO 1042, ASTM D8192, and EU Regulation (EC) No 1107/2009 (food contact compliance) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 320 × 280 × 210 mm |
| Weight | 8.2 kg |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DAIRY |
| Pricing | Available Upon Request |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Model | FLOUR |
| Measurement Principle | Near-Infrared (NIR) Reflectance Spectroscopy |
| Analysis Time | ≤45 s per sample |
| Parameters Measured | Moisture, Protein, Gluten, Starch, Ash, Color (L*a*b* or CIE XYZ) |
| Sample Handling | Non-destructive, Reagent-free, No Manual Adjustment Required |
| Calibration | Pre-loaded Factory Calibrations + User-Adjustable Multivariate Models |
| Environmental Rating | IP54-rated Enclosure |
| Operating Temperature Range | 10–40 °C |
| Software Compliance | Supports Audit Trail, User Access Levels, Electronic Signatures per FDA 21 CFR Part 11 |
| Data Export | CSV, XML, SQL via Ethernet/USB |
| Regulatory Alignment | Compliant with ISO 712 (moisture), ISO 20483 (protein), ICC Standard No. 169 (gluten), and AACC Method 44-15A (starch) |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Model | MEAT |
| Measurement Principle | Reflectance Near-Infrared Spectroscopy (NIRS) |
| Analysis Time | ≤45 s per sample |
| Parameters Measured | Moisture, Fat, Protein, Collagen (BEFFE), Ash |
| Sample Types | Raw meat, cured sausages & hams, cooked sausages, wet pet food |
| Sample Preparation | None required |
| Compliance | Designed for ISO 17025-compliant QC labs and GMP-aligned production environments |
| Interface | Touchscreen GUI with embedded calibration management |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Model | OLIVE |
| Type | Benchtop Optical Quality Analyzer for Olive Matrixes |
| Measurement Principle | Multi-Wavelength Absorption & Scattering Spectrophotometry |
| Analysis Time | ≤45 s per sample |
| Sample Types | Whole olives, olive paste, virgin olive oil, olive pomace |
| Parameters Measured | Oil yield (% w/w), moisture content (% w/w), free acidity (as oleic acid, %), peroxide value (meq O₂/kg), and auxiliary spectral indices correlated to oxidation state and phenolic profile |
| Calibration | Factory-predefined chemometric models based on reference ASTM D6584, ISO 660, ISO 8534, and IOC/T.20/Doc. No. 29 datasets |
| Compliance | CE-marked |
| Operating Environment | 10–40 °C, 20–80% RH non-condensing, IP54-rated enclosure |
| Interface | 7″ capacitive touchscreen, USB-C, Ethernet, optional RS-232 |
| Software | SpectraAlyzer v4.2 with GLP-compliant audit trail, user role management, and 21 CFR Part 11-ready configuration |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Model | SPIRITS |
| Measurement Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Analysis Time | ≤45 s per sample |
| Alcohol Range | 0–98% vol |
| Linearity | Excellent up to 98% vol |
| Sugar Interference Resistance | Yes (natural & added sugars) |
| Sample Types | Liquid spirits, distillates, diluted ethanol solutions, grain mashes, slurries, powders |
| Environmental Rating | IP54-rated housing for lab and production-floor use |
| Automation Ready | Compatible with peristaltic pump and robotic autosampler (>60 samples/h) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HP-WSB-2Y |
| Price | Upon Request |
| Measurement Range | 0–199 |
| Measured Parameters | Blue Light Whiteness (r₄₅₇), Fluorescent Whitening Value (F) |
| Light Source | LED |
| Illumination/Viewing Geometry | 45/0 (compliant with GB/T 3978) |
| Display | LCD |
| Minimum Resolution | 0.1 |
| Repeatability | ≤0.2 |
| Accuracy | ±1.0 |
| Operating Temperature | 5–35 °C |
| Operating Humidity | ≤85% RH |
| Storage/Transport Conditions | –20–50 °C, ≤90% RH |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JH-P100 |
| Price Range | USD 700–1,400 (FOB) |
| Type | Automated Polarimeter |
| Temperature Control | Integrated Peltier Element |
| Display | Digital LCD |
| Light Source | High-Stability LED (λ ≈ 589.3 nm equivalent) |
| Measurement Range | ±45° optical rotation |
| Angular Resolution | 0.01° |
| Accuracy | ±0.002° |
| Compliance | Meets ISO 11987:2016 (Polarimetric Determination of Optical Rotation) |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Zhejiang, China |
| Model | H100C |
| Instrument Type | Non-Destructive |
| Detection Wavelength Range | 650–950 nm |
| Light Source | Halogen Lamp |
| Measurement Parameters | Brix (°Bx), Titratable Acidity (TA), Dry Matter Content (DMC), Moisture Content, Internal Browning, Core Rot/Mold |
| Compatible Fruits (H100C) | Kiwifruit, Avocado, Plum, Apricot, Loquat, Waxberry (Myrica rubra), Corn (fresh ear), Potato |
| Measurement Time | ≤3 s per sample |
| Display | LCD Screen |
| Power Supply | Rechargeable 2000 mAh Li-ion Battery (≥1500 measurements per full charge) |
| Charging Input | DC 12 V / 1.5 A |
| Data Interface | USB 2.0 + Bluetooth 4.2 |
| Operating Environment | 5–30 °C, ≤85% RH |
| Dimensions & Weight | 110 × 160 × 169 mm, 400 g |
| Housing Material | ABS Plastic |
| Prediction Accuracy (Brix) | RMSEP ≈ ±0.5 °Bx (model- and sample-dependent) |
| Spectral Data Export | Raw NIR reflectance spectra (ASCII/CSV) supported |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | FLA1200 |
| Price | Upon Request |
| Photocurrent Range | 5.0 pA – 2.5 mA |
| Photometric Linearity | ±0.3% |
| Photometric Accuracy | Class I (±0.5%) |
| Display Resolution | 0.0001–99999 |
| Zero Drift | ≤3 digits in 30 min |
| V(λ) Matching Error | ≤3% (Standard Grade) |
| Cosine Response Error | ≤3% (Standard Grade) |
| UV Rejection | ≤0.5% |
| Luminous Flux Range (with integral sphere) | 0.1 lm – 9.9999 × 10⁴ klx |
| Radiant Flux Range (with integral sphere) | 0.1 µW – 9.9999 × 10⁴ W |
| Irradiance | 0.1 µW/cm² – 9.9999 × 10⁴ µW/m² |
| Illuminance | 0.1 µlx – 9.9999 × 10⁴ lx |
| Luminous Intensity | 0.1 mcd – 9.9999 × 10⁴ cd |
| Luminance | 0.1 cd/cm² – 9.9999 × 10⁴ cd/m² |
| Interface | RS-232 |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | FLA7200 |
| Pricing | Upon Request |
| Wavelength Range | 380–800 nm |
| Wavelength Resolution & Repeatability | 0.4 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Sampling Interval | 0.4 nm |
| Photometric Repeatability | ±1% |
| Integration Time | 1 ms – 6.5 s |
| Chromaticity Coordinate Accuracy | ±0.001 (under CIE Standard Illuminant A) |
| CCT Range | 1500 K – 25,000 K |
| CCT Accuracy | ±10 K (under CIE Standard Illuminant A) |
| CRI Range | 0–100.0 |
| CRI Measurement Uncertainty | ±(0.3% + 0.5) |
| MacAdam Ellipse (SDCM) Accuracy | ±1.0 |
| Luminous Flux Range | 0.1 lm – 1.9999 × 10⁵ lm |
| Photometric Linearity | ±0.5% |
| Photometric Accuracy Class | Class I (per CIE S 023/E:2018 and GB/T 39820–2021) |
| Programmable Constant-Current Source Output | 1.0 mA – 2.0 A |
| Programmable Constant-Voltage Source Output | 0.1 V – 10.0 V |
| Forward Current (I<sub>F</sub>) Measurement Range | 1.0 mA – 2.0 A |
| Forward Voltage (V<sub>F</sub>) Measurement Range | 0.1 V – 25.0 V |
| Reverse Leakage Current (I<sub>R</sub>) Measurement Range | 0.10 µA – 100.0 µA |
| Zener Voltage (V<sub>Z</sub>) Measurement Range | 2 V – 38.0 V |
| Brand | Jingfei |
|---|---|
| Model | FLA7200 |
| Optical Architecture | Miniature Fiber-Optic Spectrometer + Integrating Sphere |
| Wavelength Range | 380–800 nm (customizable) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.4 nm |
| Chromaticity Coordinate Accuracy | ±0.0003 (under CIE Standard Illuminant A) |
| Correlated Color Temperature (CCT) Range | 1500 K – 25,000 K |
| Color Rendering Index (CRI) Range | 0.0 – 100.0 |
| Photometric Linearity | ±0.3% |
| Luminous Flux Range | 0.01 lm – 1.9999 × 10⁵ lm (dependent on sphere size and configuration) |
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Brand | Jinhengxiang/JHX |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WINE |
| Pricing | Upon Request |
| Brand | Jinhuatester |
|---|---|
| Model | TH-02 |
| Measurement Principle | 0/D geometry (diffuse transmission) |
| Standards Compliance | ASTM D1003, ASTM D1044, ISO 13468, ISO 14782, GB/T 2410, JIS K 7105, JIS K 7361, JIS K 7136 |
| Illuminants | CIE-A, CIE-C, CIE-D65 |
| Aperture Sizes | 21 mm, 7 mm |
| Display | 7-inch capacitive touchscreen, Android OS |
| Measurement Time | ≤1.5 s |
| Repeatability | ±0.05% |
| Resolution | 0.01% |
| Transmittance Range | 0–100% |
| Sample Thickness Limit | ≤145 mm |
| Power Supply | DC 12 V / 3 A |
| Operating Temperature | 5–40 °C, RH ≤80% (non-condensing at 35 °C) |
| Storage Temperature | −20–45 °C, RH ≤80% (non-condensing at 35 °C) |
| Dimensions (L×W×H) | 310 × 215 × 540 mm |
| Weight | 6 kg |
| Interface | USB |
| Brand | Jinhuatester |
|---|---|
| Model | TH-02 |
| Measurement Principle | 0°/Diffuse (CIE 15:2018 compliant) |
| Standards Compliance | ASTM D1003, ASTM D1044, ISO 13468, ISO 14782, GB/T 2410, JIS K 7105, JIS K 7361, JIS K 7136 |
| Illuminants | CIE A, C, D65 |
| Measured Parameters | Haze (%), Total Luminous Transmittance (%) |
| Aperture Sizes | 21 mm, 7 mm |
| Response Time | ≤1.5 s |
| Repeatability | ±0.05% |
| Resolution | 0.01% |
| Sample Thickness Limit | ≤145 mm |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Optical Geometry | 0/D (Illumination Normal / Diffuse Collection) |
| Light Source | Long-life LED (rated >50,000 h) |
| Data Storage | Internal flash memory (≥100,000 records) |
| Interface | USB Type-A |
| Power Supply | DC 12 V / 3 A |
| Operating Temperature | 5–40 °C, RH ≤80% (non-condensing at ≤35 °C) |
| Storage Temperature | −20–45 °C, RH ≤80% (non-condensing at ≤35 °C) |
| Dimensions (L×W×H) | 310 × 215 × 540 mm |
| Weight | 6 kg |