Optical Measurement Instruments
Filter
Showing 2281–2310 of 3895 results
| Brand | Krüss |
|---|---|
| Origin | Germany |
| Model | AR4 Abbe Refractometer |
| Type | Benchtop Refractometer |
| Digital Display | Yes |
| Measurement Range | 1.3000–1.7000 nD, 0–95 %Brix |
| Accuracy | ±0.0002 nD, ±0.1 %Brix |
| Scale Division | 0.0005 nD, 0.25 %Brix |
| Light Source | 589 nm LED (Lifespan >100,000 h) |
| Temperature Measurement Range | −40 to +120 °C (Digital Thermometer) |
| Power Supply | 110/220 V AC (Switchable) |
| Dimensions | 10 × 27 × 19 cm |
| Weight | 2.5 kg |
| Calibration Standard | ASTM D1218 compliant calibration plate |
| Prism Temperature Control | Integrated thermal coupling to external thermostat (external chiller/heater required) |
| Brand | KRUSS |
|---|---|
| Origin | Germany |
| Model | DR6000 Series Digital Refractometer |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, integrated |
| Display | 5.7″ TFT touchscreen (320 × 240 px) |
| Measurement Range | 1.3200–1.7000 nD |
| Brix Range | 0–95 % |
| Refractive Index Accuracy | ±0.0001 nD |
| Brix Accuracy | ±0.1 % |
| Refractive Index Resolution | 0.0001 nD |
| Brix Resolution | 0.1 % |
| Temperature Measurement Range | 5–90 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Control Range (T-models) | 10–80 °C |
| Temperature Stability | ±0.05 °C |
| Prism Material | Sapphire |
| Light Source | 590 nm LED (Lifespan > 100,000 h) |
| Sample Contact Surface | Stainless steel |
| Enclosure | Powder-coated cast aluminum |
| IP Rating | IP65 (measurement cell) |
| Power Supply | 90–260 V AC, 50/60 Hz, 60 W |
| Interfaces | RS-232, USB, Ethernet |
| Data Storage | Embedded SQL database (99 user-defined methods, 999 measurement records) |
| Compliance | GLP-compliant, FDA 21 CFR Part 11 ready (with optional user management module) |
| Optional Accessories | Flow cell unit, external Peltier thermostat PT31, RS-232 thermal printer |
| Brand | KRUSS |
|---|---|
| Origin | Germany |
| Model | DR6000 |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5–90 °C (adjustable to ±0.1 °C) |
| Display | 5.7″ TFT touchscreen (320 × 240 px) |
| Measurement Range | 1.3200–1.7000 nD |
| Brix Range | 0–95 % |
| Refractive Index Accuracy | ±0.0001 nD |
| Brix Accuracy | ±0.1 % |
| Refractive Index Resolution | 0.0001 nD |
| Brix Resolution | 0.1 % |
| Prism Material | Sapphire |
| Light Source | LED @ 590 nm (Lifespan >100,000 h) |
| Sample Chamber | Stainless steel |
| IP Rating | IP65 (sample compartment) |
| Interfaces | RS-232, USB, Ethernet |
| Data Storage | Embedded SQL database (99 user-defined methods, 999 measurement records) |
| Compliance | GLP, FDA 21 CFR Part 11 (with optional user management), ICUMSA-compliant temperature compensation |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | FP8800 |
| Type | Automated Flame Photometer |
| Measurement Principle | Flame Atomic Emission Spectrometry (F-AES) |
| Simultaneous Channels | 5 independent, configurable for Na, K, Li, Ca, Ba, Mg |
| Display | 8.4" TFT touchscreen interface |
| Data Storage | Up to 999 measurement records |
| Throughput | Up to 300 measurements per hour |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11 (audit trail, electronic signature support), DHCP & LIMS integration capable |
| Calibration Output | Tabular and graphical calibration curves |
| Safety | Integrated intelligent flame safety interlock system |
| Category | Optical Measurement Instrument — Flame Photometer |
| Brand | KRUSS |
|---|---|
| Origin | Germany |
| Product Type | Handheld Refractometer |
| Model Series | HR-Serie |
| Measurement Principles | Critical Angle of Total Internal Reflection |
| Calibration | Distilled Water or Certified Calibration Plate |
| Temperature Compensation | Manual or Automatic (model-dependent) |
| Optical System | Abbe-type Prism Assembly with High-Grade Optical Glass |
| Compliance | Designed per ISO 21748 (Refractometry — Guidance for the Determination of Repeatability and Reproducibility) and ASTM D1218 (Standard Test Method for Refractive Index of Hydrocarbon Liquids) |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Pricing | Upon Request |
| Current Ratings | AUX-35: 3.07 A |
| AUX-50 | 4.17 A |
| AUX-100 | 8.33 A |
| Operating Voltage | 12–13.3 V DC |
| Color Temperature | 3000 K |
| Rated Lifetime | 600–2000 hrs |
| Mounting | 1-inch flange interface |
| Software Compatibility | LightMtrx® |
| Power Supply Requirement | Labsphere adjustable DC power supply |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COLOSUS System |
| Price Range | USD $65,000 – $105,000 |
| Spectral Range | 0.3–14 µm |
| Calibration Traceability | NIST-traceable radiance/irradiance |
| Dynamic Range | >1×10¹⁰ |
| Uniformity | >98% (spatial) |
| Blackbody Temperature Range | −40 °C to +175 °C |
| Blackbody Emissivity | >0.998 |
| Temperature Stability | ±0.01 °C |
| Aperture Size | 4 in (102 mm) |
| Software Platform | IRWindows™ 4 |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CSS |
| Price Range | USD 7,000 – 14,000 |
| Beam Divergence | <3° |
| Working Distance | 3 m |
| Illuminated Area Diameter at 3 m | 20 cm |
| Irradiance Uniformity | ≥98% |
| Spectral Range | 350–2400 nm |
| Correlated Color Temperature | 5250 K |
| Typical Irradiance at 3 m | 10,000 lux (≈1 Sun, AM1.5G equivalent) |
| Control Interface | PC-based software with real-time intensity adjustment |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | CSTM-CM-PD |
| Price Range | USD 1,400 – 140,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSTM-LPMS |
| Price Range | USD $1,200 – $65,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CSTM-RC |
| Wavelength Range | 300–1100 nm |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | CSTM-RTC |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (sample & 9° specular-reflected beam), 0.5-inch top detector port, bottom detector port (RTC), integrated central sample mount |
| Geometry | 9°/h reflectance, variable-angle incidence capability (RTC), specular trap included |
| Internal Baffle Design | Low-profile, minimized obstruction to maximize wall visibility |
| Aperture Edge | Knife-edge for wide-angle scatter collection |
| Compliance | ASTM E1331, ISO 13468, ISO 13469, USP <857>, compatible with GLP/GMP data integrity workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CSTM-VCSEL-PW-060-LIVT |
| Pricing | Available Upon Request |
| Integrating Sphere Material | Spectralon® / Spectraflect® / Permaflect® |
| Sphere Diameter | 6 in (customizable) |
| Input Port Diameter | 1.5 in (customizable) |
| Spectrometer Wavelength Range | 800–980 nm |
| Spectral Resolution (FWHM) | 0.1–0.16 nm |
| Wavelength Accuracy | ±0.1 nm |
| Maximum Sampling Rate | 200 kHz |
| Optical Power Range (Spectralon®, 940 nm) | 1 mW – 200 W |
| High-Speed Detector Linearity | ±0.5% |
| Detector Measurement Accuracy | ±1% |
| Detector Effective Digits | 5 |
| VCSEL Temperature Control Range | 1–85 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Labsphere |
|---|---|
| Model | FOL-150-S |
| Light Source Type | Quartz-Tungsten-Halogen (QTH) |
| Output Power | 150 W |
| Spectral Range | 350 nm – 1000 nm (QTH core), extended usable range 400 nm – 1600 nm via fiber transmission |
| Fiber Interface | SMA 905 connector |
| Integrated Hot Mirror | Yes |
| Compatibility | Designed for Labsphere integrating spheres (e.g., RSA, UV-VIS-NIR series) |
| Cooling | Forced-air convection |
| Dimensions (H×W×D) | 140 × 220 × 320 mm |
| Weight | 4.8 kg |
| Regulatory Compliance | CE, RoHS, UL-listed power supply |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FS2 |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPS |
| Configuration | Solid-State Laser Sources & Integrated Measurement Subsystem |
| Optical Coating Options | Spectraflect®, Infragold®, or Spectralon® |
| Wavelength Range | 200–5000 nm (UV-Vis-NIR-MIR) |
| Beam Acceptance Angle | Up to ±40° half-angle |
| Cooling | Optional water-cooling module with user-selectable chiller integration |
| Detector Compatibility | Dual-detector or dual-spectrometer mounting interface |
| Attenuation | Polarization-insensitive neutral-density filtering |
| Target Plate | Integrated laser diffuser plate for beam energy dispersion |
| Thermal Management | Active heat dissipation architecture for sustained high-power operation |
| Compliance | Designed to support ISO/IEC 17025-compliant calibration workflows and GLP/GMP traceability requirements |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPS |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HELIOS |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Illumia |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro |
| Sphere Diameter Options | 0.5 m, 1.0 m, 1.65 m, 2.0 m |
| Measurement Geometry | 2π and 4π compatible |
| Compliance | IESNA LM-79, IESNA LM-80 |
| Core Components | High-resolution CCD spectrometer, precision programmable current source, thermoelectric cooler (TEC) temperature controller with real-time junction temperature monitoring, auxiliary calibration lamp, Illumia Pro measurement software |
| Data Management | Automated acquisition, traceable metadata logging, export to CSV, XML, and industry-standard report formats |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro3 |
| Sphere Diameter | 50 cm |
| Spectral Range (Calibrated) | 350–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Integration Time | 40 µs – 5 s |
| Measurement Geometry | 2π |
| Coating | Spectralect® White Diffuse Reflectance Coating |
| Software | Integral™ v5.x (with Temperature, Current & Voltage Control, Real-Time LIVT Synchronization, and GLP-Compliant Data Logging) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Plus 2 |
| Spectrometer Options | CDS600 (200–850 nm), CDS610 (350–1000 nm), CDS2600 (325–1050 nm), CDS3020 (350–830 nm), CDS3030 (350–1100 nm) |
| Integrating Sphere Diameters | 25 cm – 195 cm |
| Coating Reflectance | 97–98% @ visible range |
| Shutter | Optional (CDS2600/CDS3020/CDS3030) |
| Compliance | IES LM-79-19, LM-78, LM-82, CIE S 025/E:2015 |
| Auto-Stability Detection | Yes |
| Report Format | Customizable Excel export with multilingual UI support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Pro3-UV |
| Integrating Sphere Diameter | 15 cm |
| Spectral Range (Calibrated) | 200–400 nm |
| Wavelength Accuracy | ±0.4 nm |
| Integration Time | 8 ms – 900 s |
| Spectrometer | CDS-2600-UV |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia®Plus2-2600 |
| Integrating Sphere Diameter | 165 cm or 195 cm |
| Spectral Range | 325–1050 nm |
| Temperature Control Range | 15–80°C |
| Typical Ramp Rate (20→80°C) | 52 min |
| Detector | TE-cooled, back-illuminated CCD array |
| Exposure Time | 8 ms – 900 s |
| Compliance | IES LM-79-19, LM-82-12, LM-78-15, ISO/CIE S 025:2015 |
| Software | Integral® v5.x with automated stability assessment and CFR 21 Part 11-ready audit trail |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ILT2400 UVG |
| Pricing | Available Upon Request |
| Spectral Range | 240–310 nm |
| Irradiance Range | 10 nW/cm² to 500 µW/cm² |
| Radiant Exposure (Dose) Range | 10 nJ/cm² to >1 MJ/cm² |
| Calibration | NIST-Traceable, ISO/IEC 17025:2017 Accredited |
| Detector Type | UVGI-Optimized SED240/WBS320/W Filtered Photodiode |
| Display | 4.3″ VGA Capacitive Touchscreen |
| Current Measurement Range | 50 pA – 1 mA |
| Dynamic Range | 8 decades |
| Bias Voltage | 5 V Reverse Bias |
| Internal Storage | 4 GB |
| Operating Temperature | 0–40 °C |
| Interfaces | USB Micro (data download), USB Mini (charging & remote logging via DataLight III) |
| Dimensions | 1.6″ H × 3.0″ W × 6.0″ L |
| Weight | 0.95 kg |
| Enclosure | Rugged Portable Carry Case |
| Compliance | CE (EMC Class B, no RF emissions interference) |
| Software | DataLight III (macOS & Windows compatible) |
| Sensor Connector | 15-pin D-sub |
| Application Scope | Non-pulsed UV-C sources only — low-pressure & medium-pressure mercury lamps, UVC LEDs, excimer lamps |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LCA-XXXXX-XXX |
| Price | Upon Request |
| Wavelength Range | 300–1100 nm |
| Brand | LabSphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LF Human Eye Safety Testing Solution |
| Pricing | Available Upon Request |
| Spectralon Transmittance | 25% or 50% |
| Spectralon Target Size | 30 cm × 50 cm (customizable) |
| Spectralon Spectral Flatness | ±1.5% |
| Wavelength Range | 400–1000 nm |
| DUT-to-Target Distance | 5–30 cm |
| Maximum DUT Divergence Angle | 80° (customizable up to 120°) |
| Eye Safety Aperture | 7 mm |
| Measurement Modes | Total Radiant Power, Per-Spot Radiant Power, Spatial Distribution, Angular Emission Profile, MPE (Maximum Permissible Exposure) Compliance Assessment |
| Data Output Formats | .txt, .csv |
| Software Features | Pixel-level spot detection & centroid localization, intensity calibration with NIST-traceable reference, real-time MPE calculation per IEC 62471 and ANSI Z136.1 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFC |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LFC-150 |
| Integrating Sphere Diameter | 1.5 m |
| Spectral Range | 250–850 nm or 350–1000 nm (configurable) |
| Calibration Traceability | NIST-traceable |
| Compliance | LM-79, CIE 127:2007, GB/T 7922, GB/T 5702, IESNA standards |
| Measurement Modes | 2π and 4π |
| Reflectance of Sphere Coating | ≥96% (Spectralon®-equivalent 680 coating) |
| Software | LFC Control & Analysis Suite (supports ASTM E308, CIE 15:2018, CIE 13.3, and USP <1058> data handling protocols) |
| Brand | Labsphere |
|---|---|
| Model | LFHH-1000 |
| Origin | Shanghai, China |
| Wavelength Range | 350–1050 nm |
| Spectral Resolution | ~1.5 nm |
| Signal-to-Noise Ratio | 300:1 |
| Detector | Hamamatsu S11639 CCD |
| Pixel Count | 2048 × 1 |
| Wavelength Accuracy | <0.2 nm |
| A/D Conversion | 16-bit |
| Acceptance Angle | 25° |
| Standard Reference Panel | 30 × 30 cm Spectralon® (99% reflectance, NIST-traceable options available) |
| Integration Time | 10–65 ms |
| Power Supply | Internal rechargeable Li-ion battery |
| Dimensions (L×W×H) | 17.5 × 9 × 3.5 cm |
| Weight | 1.0 kg |
| GPS Module | Integrated |
| Fiber Interface | SMA 905 compatible |
| Operating System | Android-based embedded platform |