| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LFPMS |
| Pricing | Available Upon Request |
| Power Range | 100 nW – 100 W |
| Wavelength Range | 350 nm – 1800 nm |
| Calibration Traceability | National Institute of Metrology (NIM), China |
| Integrating Sphere Diameters | 2″ (5 cm), 4″ (10 cm), 6″ (15 cm), 8″ (20 cm) |
| Input Aperture | 0.5″ (12.7 mm) for LFPMS-020 |
| Coating Reflectance | ≥98% (Spectralon®-type diffuse reflectance coating) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LMS-3M |
| Diameter | 3 m |
| Compliance | IESNA LM-79, LM-80, ENERGY STAR® Thermal Test Requirements |
| Internal Coating | Spectraflect® (≥98% diffuse reflectance, 400–700 nm) |
| Measurement Geometry | Configurable 4π or 2π via optional baffle & port reducer |
| Detector Compatibility | Multiple photometric and spectroradiometric sensors simultaneously |
| Mounting Flexibility | Upward, downward, or axial lamp orientation |
| Temperature Control | Integrated thermal monitoring module with inlet/outlet baffles |
| Structural Assembly | Field-installed modular design (wedge segments, base frame, fasteners) |
| Dimensions (packed) | ~3.3 × 2.3 × 1.6 m per crate |
| Required Site Conditions | Level floor, structural load capacity ≥500 kg/m² |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS |
| Coating Material | Infragold® |
| Cooling | Integrated Water-Cooling System |
| Spectral Range | 250 nm – 12 µm |
| Beam Acceptance Angle | Up to ±40° half-angle |
| Detector Compatibility | Dual-detector or spectrometer mounting ports |
| Thermal Management | Active water-cooling with user-selectable chiller interface |
| Target Plate | Integrated laser diffusing target plate |
| Compliance | Designed for ASTM E275, ISO/IEC 17025-aligned optical power measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS Laser Power Measurement System |
| Sphere Diameters | 2", 4", 6" |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Spectral Range | 350–1700 nm |
| Power Range | ~1 nW to ~数百 W (dependent on configuration) |
| Calibration Traceability | NIST-traceable |
| Coating Materials | Spectraflect®, Infragold®, or Spectralon® |
| Input Port Angle | 45° relative to detector axis |
| Metrics Reported | Average Radiant Power (CW), Average Peak Radiant Power (Pulsed), COV (CW), Sampling Rate (Hz), Scan Interval (s), Power Density (W/cm²), Max/Min CW Power, Overrange Alert, Pulse Width, Repetition Rate, Standard Deviation (CW), System Responsivity Thresholds (min/max), Total Measurement Time, Pulse Count, Wavelength Selection (user-defined per calibration data) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS System |
| Spectral Range | 350–1700 nm (Si & InGaAs detectors) |
| Integrating Sphere Diameters | 2", 4", 6" |
| Coating Options | Spectraflect®, Spectralon®, Infragold® |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Power Range | ~1 nW to >100 W (configuration-dependent) |
| Input Port Angle | 45° off-axis |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS-1 |
| Detector Type | Calibrated Photodiode or Thermopile Sensor |
| Spectral Range | Customizable (e.g., 190–1100 nm or 800–1800 nm) |
| Power Range | 100 µW to 100 W (CW), up to 1 kW peak (pulsed, with appropriate attenuation) |
| Input Port Diameter | 25 mm, 50 mm, or 100 mm (configurable) |
| Coating | Spectralon® or custom diffuse reflectance coating (≥99% uniform reflectance) |
| Calibration Traceability | NIST-traceable |
| Compliance | ISO/IEC 17025 accredited calibration available |
| Software Interface | USB 2.0, compatible with Windows-based LPMS Control & Analysis Suite |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPS |
| Coating Options | Spectraflect®, Infragold®, Spectralon® |
| Wavelength Range | UV–Vis–NIR–MIR (200 nm – 12 µm) |
| Beam Acceptance Angle | Up to ±40° half-angle |
| Detector Compatibility | Dual-detector or spectrometer integration supported |
| Cooling Options | Air-cooled and water-cooled configurations available |
| Target Plate | Integrated laser beam diffuser plate |
| Thermal Management | Optimized heat dissipation architecture for high-power operation |
| Compliance | Designed for ASTM E275, ISO/IEC 17025-aligned calibration workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PERMAFLECT® |
| Price Range | USD $0–$7,200 (est.) |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QES-1000 |
| Price Range | USD 14,000 – 28,000 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSA-FO-150 Fiber-Optic Single-Beam Integrating Sphere |
| Wavelength Range | 250 nm to 2500 nm |
| Brand | Labsphere |
|---|---|
| Model | RSA-FO-150-800-S |
| Wavelength Range | 360–1000 nm |
| Configuration | Dual-beam reflectance & transmittance measurement system with fiber-optic illumination and spectrometer integration |
| Integral Sphere Type | Dual-beam reflectance & transmittance sphere (150 mm diameter, barium sulfate coating, FO port configuration) |
| Compliance | ASTM E275, ASTM E903, ISO 9050, ISO 13468, ISO 14782, CIE S 014 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSA-FO-TW-76 |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Model | RSA-REF-50-DB |
| Illumination Geometry | 8°/h (8° illumination, hemispherical detection) |
| Sphere Diameter | 50 mm |
| Light Source | Integrated Tungsten-Halogen or Optional LED Module |
| Fiber Optic Interface | SMA 905 |
| Compliance | ISO/CIE Compliant Optical Design |
| Origin | Shanghai, China |
| Distribution Status | Authorized Distributor |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF, RT-060-IG, RTC-060-SF, RTC-060-IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (RT) |
| Detector Port | 0.5-inch (top-mounted for RT, bottom-mounted for RTC) |
| Mirror Trap | Integrated specular beam trap |
| Sample Mounting | Adjustable center-stage (RTC), dual 1-inch sample holders (RT), optional jaw-type / clamp-type / slot-type fixtures |
| Compliance | Designed for ASTM E1331, ISO 9050, CIE No. 15, USP <857>, and GLP/GMP-aligned measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF/IG, RTC-060-SF/IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports, top 0.5-inch detector port, bottom detector port (RTC only), specular beam trap, knife-edge port geometry, minimized baffle design |
| Compliance | Designed for ASTM E1331, ISO 13468, ISO 13469, CIE No. 15, USP <1061>, and GLP-compliant optical characterization workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT/RTC |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Configuration | RT (fixed 9°/h geometry), RTC (motorized or manual variable-angle sample stage) |
| Detector Port | Top (RT), Bottom (RTC) |
| Standard Aperture | Five 1-inch ports + 0.5-inch detector port |
| Mirror Trap | Integrated specular beam trap |
| Baffle Design | Low-profile, minimized obstruction for maximal wall visibility |
| Entrance Geometry | Knife-edge apertures for wide-angle scatter collection |
| Compliance | ASTM E1331, ISO 9050, ISO 13468, ISO 14782, CIE 110, USP <857>, FDA 21 CFR Part 11 (with optional software audit trail) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-PT |
| Type | Integrating Sphere-Based Uniform Light Source for Photometric and Radiometric Calibration |
| Compliance | NIST-traceable calibration options available |
| Control Interface | Analog 0–10 V and digital RS-232/USB |
| Dynamic Range | >10⁶:1 (typical, dependent on detector and configuration) |
| Spectral Range | 350–1000 nm (standard halogen/tungsten-halogen lamp configuration) |
| Uniformity | ≥98% spatial uniformity over output port (per ISO 9050 and CIE S 023) |
| Stability | <0.2% RMS over 30 min (thermal + power supply stabilized) |
| Port Diameter | 4", 6", or 8" (configurable) |
| Lamp Life | ≥2000 h (rated at nominal voltage) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SPECTRA-QT |
| Pricing | Available Upon Request |
| Spectral Irradiance Range | 375–1100 nm |
| Spectral Bandwidth | 5–10 nm |
| Wavelength Accuracy | ±0.6 nm |
| Aperture Diameters | 22 mm, 23.9 mm, 26.2 mm, 29 mm |
| Max Spectral Irradiance (400 nm) | 12 μW/cm²/nm |
| Max Spectral Irradiance (600 nm) | 21 μW/cm²/nm |
| Max Spectral Irradiance (800 nm) | 5 μW/cm²/nm |
| Max Spectral Radiance (400 nm) | 32 μW/cm²·sr·nm |
| Max Spectral Radiance (600 nm) | 54 μW/cm²·sr·nm |
| Max Spectral Radiance (800 nm) | 11 μW/cm²·sr·nm |
| UV-VIS Stability (550 nm) | <1.5% over 5 s |
| VIS-NIR Stability (750 nm) | <0.05% over 5 s |
| NIST-Traceable Calibration | Yes |
| Software Development Kit (SDK) | Included |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | SpectraBlack |
| Reflectance Range | <5% (250–2500 nm) |
| Surface Type | Micro-porous engineered matte black |
| Compliance | ISO 13694, ASTM E275, NIST-traceable calibration available |
| Material Composition | Carbon-loaded polymer composite with controlled pore structure |
| Operating Temperature | –40°C to +85°C |
| Durability | Abrasion-resistant, non-outgassing, low particulate shedding |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RTC |
| Price Range | USD $0 – $50,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon® Target Board |
| Calibration Range | 250–2500 nm (NIST-traceable) |
| Reflectance Options | 2% to 99% |
| Standard Mounting Frame | Anodized Aluminum (Rough Surface Finish) |
| Dimensions Available | 2×2 in to 24×24 in |
| Thickness | 0.65 in |
| Thermal & Chemical Stability | High |
| Cleanability | Water-rinsable |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOCS-20 |
| Pricing | Available Upon Request |
| Integration Options | 0.5 m, 1.0 m, 1.65 m, and 2.0 m integrating sphere configurations |
| Standards Compliance | IESNA LM-79-19, LM-80-15 |
| Thermal Control | Integrated TEC-based temperature stabilization with real-time junction/substrate temperature monitoring |
| Electrical Measurements | Current (I), Voltage (V), Electrical Power (P) |
| Photometric Measurements | Luminous Flux (lm), Luminous Efficacy (lm/W), Chromaticity Coordinates (CIE 1931 x,y |
| Thermal-Optical-Electrical Correlation | Simultaneous acquisition of L, V, I, and T under controlled thermal boundary conditions |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Price Range | USD 28,000 – 42,000 |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Model | Integrating Sphere Light Source |
| Luminance Range | 0–10,000 cd/m² |
| Uniformity at Port | ≥99% |
| Luminance Stability (after warm-up) | ±0.5% |
| Color Temperature Control | Software-Adjustable (2700K–6500K) |
| Real-Time Output Monitoring | Integrated photodiode feedback |
| Control Interface | USB/Ethernet with SDK for custom integration |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | USS-1200LL |
| Pricing | Upon Request |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | USS-2000C |
| Calibration | NIST-traceable certificate included |
| Output Control | 0–100% continuous electronic dimming |
| Configurable Aperture Sizes | 2", 4", 6", 8", 12" (standard options) |
| Spectral Monitoring Options | Integrated Si, InGaAs, and UV-enhanced photodiode detectors for broadband radiometric coverage (200–1700 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV 3000S |
| Wavelength Range | 290–500 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Step | Adjustable (default 1 nm) |
| SPF Measurement Range | 0–50+ (in vitro) |
| Optical Density Dynamic Range | 3 AU |
| Compliance | ISO 24443:2021, ISO 24444:2019, COLIPA/CTFA In Vitro Guidelines, ASTM E2685 |
| Software Platform | .NET Framework®-based, Windows® 11 Compatible |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | XTH-2000C |
| Calibration Traceability | NIST-traceable Certificate Provided |
| Color Temperature Range | 3000 K to 6000 K |
| Spectral Range | 250 nm to 1100 nm |
| Output Monitoring | Integrated spectrometer and calibrated photodetector |
| Configurable Aperture Sizes | Standard options include 50 mm, 100 mm, and 200 mm exit ports |
| Control Interface | RS-232 / USB with LabSphere SpectraSuite-compatible software |
| Brand | LabSphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | XTH-6500C |
| Calibration Traceability | NIST-traceable Certificate Provided |
| Light Source Configuration | Dual-lamp (Xenon + Tungsten-Halogen) |
| Spectral Range | 250–2500 nm |
| Color Temperature Tunability | 2800 K to 6500 K (continuous) |
| Output Control | Motorized stepwise & analog continuous dimming |
| Software Interface | LabSphere Uniformity Control Suite (UCCS) v3.2 |