| Brand | Aotsaisiens |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Chromatography Column |
| Model Range | 150 × 4.6 mm, 200 × 4.6 mm, 250 × 4.6 mm |
| Particle Size | 5 µm, 7 µm (C18 only), 10 µm |
| Pore Size | 100 Å |
| Surface Area | 340 m²/g |
| Pore Volume | 0.9 mL/g |
| Carbon Load | 19% (3.2 µmol/m²) |
| pH Stability | 1.5–9.5 |
| Max. Operating Pressure | 700 bar (10,000 psi) |
| End-Capping | Fully end-capped (C18) |
| Metal Impurities (AAS) | Na < 10 ppm, Al < 10 ppm, Fe < 10 ppm |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UF-9100 |
| Pricing | Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | P6100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | MAS-100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | MAS-100 |
| Detection Principle | Purge-and-Trap GC-Cold Vapor Atomic Fluorescence Detection (GC-AFD) |
| Compliance | HJ 977–2018 |
| Detector Type | Integrated Miniaturized Cold Vapor Atomic Fluorescence Detector (AFD) |
| Column Compatibility | Capillary GC columns |
| Auxiliary Detectors Supported | FID, ECD, TCD, FPD, TSD |
| Mercury Speciation | Methylmercury, Ethylmercury |
| Sample Matrix | Aqueous solutions |
| Derivatization Reagent | Sodium Tetrapropylborate (NaBPr₄) |
| Trapping Medium | Tenax® sorbent tube |
| Carrier Gas | Argon |
| Post-Detector Mercury Capture | Gold-coated Wire Trap with Active Vacuum Pump |
| Optical Design | Multi-stage stray-light suppression fluorescence cell |
| High-Temperature Module | 950 °C pyrolysis with nano-scale thermal insulation |
| Footprint | <120 mm × 100 mm × 80 mm (AFD unit only) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | QA-3 |
| Price | USD 180 (approx.) |
| Dew Point | -40°C |
| Output Flow Rate | 0–3 L/min |
| Output Pressure | 0–0.4 MPa |
| Operating Temperature | 10–40°C |
| Relative Humidity Limit | ≤85% (non-condensing, dust-free, non-corrosive environment) |
| Dimensions (L×W×H) | 225 × 170 × 370 mm |
| Weight | 3 kg |
| Brand | Beifen Sanpu |
|---|---|
| Model | BF-4 |
| Type | Catalytic Hydrocarbon Removal Air Purifier |
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Input Hydrocarbon Concentration (e.g., CH₄) | <100 ppm |
| Output Hydrocarbon Concentration (e.g., CH₄) | <0.1 ppm |
| Inlet Pressure Range | 0–0.6 MPa |
| Flow Rate Capacity | 0–1000 mL/min |
| Catalyst Operating Temperature | 350 °C (max) |
| Furnace Temperature Control Range | 0–600 °C |
| Warm-up Time to Stability | <1 h |
| Ambient Operating Temperature | 0–40 °C |
| Relative Humidity Limit | <85 % RH |
| Power Supply | 220 V AC, 50 Hz |
| Brand | CAMAG (distributed by JHT / Yichenghengda) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | CAMAG TLC Systems (e.g., ATS 4, Linomat 5, Nanomat 4, ADC 2, AMD 2, TLC Visualizer 2, TLC Scanner 4, TLC-MS Interface 2, visionCATS 5) |
| Pricing | Upon Request |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ET620 |
| Detection Principle | Thermal Flow Sensing via Heated Capillary Tube |
| Power Consumption (Standby) | <5 W |
| Alarm Output | Relay Contact (NO/NC), 24 V DC Compatible |
| Compliance | CE Marked, Designed for Integration into ISO/IEC 17025 and GLP-Compliant HPLC Environments |
| Operating Temperature Range | 5–40 °C |
| Enclosure Rating | IP54 |
| Signal Interface | Dry Contact Output for PLC/SCADA/LIMS Integration |
| Heater Control Precision | ±0.5 °C |
| Brand | Hailong |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Chromatography Workstation |
| Pricing | Available Upon Request |
| Channel Options | Dual-Channel, Triple-Channel |
| Application Modules | TCM Fingerprint Similarity Analysis, GPC Calibration, Transformer Oil DGA, Indoor TVOC Quantification, PONA & Simulated Distillation (Petroleum), Natural Gas Calorific Value Calculation, Tobacco Alkaloid Profiling, Baijiu Volatile Compound Analysis, Amino Acid Derivatization Quantitation |
| Compatibility | GC and LC Detectors (FID, TCD, ECD, UV-Vis, DAD, FL, RI) |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model Range | Standardized Domestic Series |
| Price Range | USD 70 – 2,800 |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | LU3100 Quaternary |
| Quotation | Upon Request |
| Flow Range | 0.001–10.000 mL/min (settable in 0.1% increments) |
| Gradient Accuracy | ≤ ±2.0% |
| Mixing Volume | 500 µL |
| Power Supply/Power Consumption | AC 220 V ±10%, 50 Hz / 30 W |
| Dimensions/Weight | 420 × 300 × 115 mm (L×W×H) / 4 kg |
| Vacuum Degassing | Integrated with external DG3110 quaternary degasser |
| Brand | Hailong |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Configuration | Integrated Gas Chromatography (GC) and Liquid Chromatography (LC) Platform |
| EPC Capability | Optional Electronic Pressure Control for GC Carrier/Gas Lines |
| Flow Rate Range (LC) | 0.1–10.0 mL/min |
| Maximum Backpressure (LC) | Up to 30 MPa (≈306 kg/cm²) |
| Column Efficiency | ≥5,000 plates/meter |
| Temperature Program | 7–10 ramp segments with post-run oven cooling |
| Safety Features | Overtemperature cutoff, real-time self-diagnosis, intelligent rear-door airflow control |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Compliance | Designed to support ISO/IEC 17025 workflows, compatible with GLP/GMP data integrity requirements when paired with validated software |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-100 Series Auto Sampler |
| Pricing | Upon Request |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | Capillary Column |
| Pricing | Available Upon Request |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | JHF-122 |
| Fraction Capacity | 90 positions |
| Collection Modes | Time-based, Peak-triggered, Manual, Memory-programmed |
| Input Signals | Start/Stop TTL-compatible (10 mV / 1 V threshold) |
| Output Signals | Event Marker (TTL) |
| Program Storage | One dedicated file per collection method |
| Accessories | Benchtop mounting stand, 20 × glass collection tubes (standard size), 20 × PTFE inlet tubing, 3-way solenoid valve |
| Dimensions (W×H×D) | 286 × 335 × 387 mm |
| Power Supply | AC 100–240 V, 50/60 Hz, 50 VA |
| Weight | 8 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SD-900 |
| Pricing | Available Upon Request |
| Distillation Method | Simple Distillation |
| Heating Method | Electric Oil Bath |
| Temperature Control Range | Ambient to 78 °C |
| Distillation Vessel Material | SUS316 with PTFE Coating |
| Distillation Vessel Capacity | 19 L (Usable Volume: ~15 L) |
| Cooling Tower | Glass Ball Condenser, 500 mm Height |
| Temperature Controller | Digital PID Display |
| Timing Function | Digital Stopwatch |
| N₂ Pressure Control | Integrated Digital Pressure Sensor |
| Heater Type | Stirred Oil Bath Heater |
| Power Rating | 1.5 kW |
| Control Logic | Sequential Automated Control |
| Transfer Pump | Electromagnetic Gear Pump (Max Flow: 1.5 L/min) |
| Valves | Four 3-Way Solenoid Valves |
| Emergency Shutdown | Manual Master Power Cut-off Button |
| Tubing & Fittings | PTFE Tubing, PTFE Connectors, SUS316/SUS303 Hardware |
| Dimensions (W×H×D) | 600 × 1530 × 480 mm |
| Electrical Supply | Single-phase AC 200 V / 10 A or AC 100 V / 5 A |
| Net Weight | 100 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CA-410 Series (including CA-VP410, CA-VP410A, CA-P410, CA-P410H, CA-MP410, CA-MP410H, CA-VP402, CA-VP404, CA-VP410T) |
| Measurement Aperture | Ø2.1 mm, Ø4 mm, Ø10 mm |
| Receiving Angle | ±4° to ±10° (model-dependent) |
| Guaranteed Measurement Distance | 10–200 mm (model-dependent) |
| Luminance Range (Guaranteed Accuracy) | 0.0003–30,000 cd/m² |
| Chromaticity Range (Guaranteed Accuracy) | 0.003–30,000 cd/m² |
| Zero Calibration Time | 3–10 s (model-dependent) |
| Interface Options | USB (IF-A28/A40/A42/A43/A30/A31/A32), RS-232C, BNC sync |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | FC Jr |
| Dimensions | 28 cm (W) × 27 cm (H) × 31 cm (D) |
| Weight | 4.7 kg |
| Temperature Range | 0–40 °C |
| Step Timer Range | 1 s – 99 h 59 min 59 s |
| Drop Counter Range | 1–999,999 |
| Volume Counter Range | 1–999,999 units |
| Peak Detection Modes | Slope-based and/or plateau-based triggering, combinable with time windows |
| Time Windows per Program | Up to 10 |
| Tube Exchange Time (center-to-center) | 200–450 µs (dependent on tube diameter) |
| Program Storage | 9 full collection protocols with internal battery-backed memory |
| Interface | RS232 for LC system integration |
| Collection Modes | Time-based, drop-count-based, volume-based, and peak-triggered (UV/absorbance signal) |
| Collection Patterns | Linear (left-to-right) or spiral |
| Tube Holder Options | Compatible with 12–25 mm diameter tubes |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | R1 |
| Dimensions | 35.6 × 31.1 × 33.0 cm (H×W×D) |
| Weight | 7.7 kg (without rack) |
| Max Flow Rate | 100 mL/min |
| Delay Volume | Micro-liter level (valve positioned at outlet of flow path) |
| Communication | Ethernet (TCP/IP) & RS-232 |
| Power | 100/117 VAC or 234 VAC, 50/60 Hz |
| Rack Options | 144×12 mm tubes |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP |
| Pricing | Available Upon Request |
| Pump Flow Range | 1–24 mL/min |
| Maximum Pressure | 10,000 or 18,000 psi |
| Pump Control Interface | RS-232 with pressure/flow sensors |
| Construction | Stainless Steel (SS) |
| Voltage | 110/220 V AC |
| Column Hardware Included | Two 4.6 × 150 mm stainless steel column assemblies (including endfittings, frits, and 2 µm stainless steel frits) |
| Slurry Vessel | 20 mL agitated slurry reservoir |
| Packing Accessories | Compression ferrules, metal bands, reducing adapters, O-rings, 1/16″ OD × 0.03″ ID stainless steel tubing |
| Stationary Phase | 10 g C18 silica-based packing material |
| Software | Quick-Set pump control software |
| Compliance | Designed for GLP-compliant column manufacturing environments |
| Brand | Labman |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LBI860 |
| Pricing | Available Upon Request |
| Brand | LUDAHY |
|---|---|
| Model | LD-MRF1700 |
| Origin | Beijing, China |
| Heating Power | 300 W |
| Temperature Control Range | 0–400 °C |
| Methanization Temperature | 350–380 °C |
| Temperature Sensor | Thermocouple |
| Conversion Tube Configuration | U-shaped, 1/8″ or 1/16″ OD × 250 mm |
| Inlet/Outlet Fitting | 1/8″ or 1/16″ compression |
| Catalytic Efficiency | ≥98% |
| Catalyst Lifetime | ≥2 years (under sulfur- and oil-free sample conditions) |
| Minimum Detectable Concentration (CO/CO₂) | ≤0.1 ppm (when coupled with FID) |
| H₂ Requirement | ≥60% of total carrier gas flow (by volume) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ME99-1 |
| Price | USD 4,500 (FOB Shanghai) |
| UV Wavelengths | 220, 254, 280, 340 nm |
| Timer Range | 1 min – 24 h |
| Flow Rate | 0.1–10 mL/min |
| Fraction Capacity | 12 mL × 100 tubes |
| Temperature Control Range | 0–45 °C |
| Chromatography Cabinet Volume | 250 L |
| Net Weight | 105 kg |
| Detection Principle | UV-Vis Absorbance at Fixed Wavelengths |
| Data Acquisition | Analog signal output to external recorder or PC via dedicated chromatogram acquisition interface |
| Brand | Minik |
|---|---|
| Model | MS210 |
| Origin | Beijing, China |
| Category | Other Chromatography Instruments |
| Application | Pre-analytical vaporization of liquid hydrocarbons for GC and coulometric Karl Fischer analysis |
| Compliance | GB/T 3727–2003, GB/T 6023–2008 |
| Liquid Inlet Pressure | 0.69–2.75 MPa |
| Output Flow Rate | 0–5 L/min (adjustable) |
| Vaporization Temperature Range | Up to 230 °C |
| Heating & Jacket Temperature Control Range | Ambient +5 °C to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Mass Flow Control Range | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Sample Introduction | Liquid or gas phase |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MS200S |
| Pricing | Available Upon Request |
| Liquid Sample Inlet Pressure Range | 0.69–2.75 MPa |
| Gas Sample Inlet Pressure Range | 0.69–2.07 MPa |
| Temperature Control Range (Heating & Trace Heating) | Ambient +5°C to 230°C |
| Temperature Stability | ±0.1°C |
| Carrier Gas Flow Rate | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Operating Ambient Temperature | −18°C to +65°C |
| Surface Passivation | SilcoTek® SilcoNert®-treated Stainless Steel Tubing |
| Brand | NANOSPACE |
|---|---|
| Origin | Japan |
| Model | F3012 |
| Max. Operating Pressure | 35 MPa |
| Dead Volume | 1.0 µL |
| Wetted Materials | PEEK, Ceramics |
| Control Modes | Manual, Time-Programmable (0.00–999.99 min), External TTL Trigger (Start Signal), SYSCON & PC Communication |
| Power Supply | AC 100 V ±10%, 50/60 Hz, 15 W |
| Dimensions | 120(W) × 230(H) × 491(D) mm |
| Weight | 10 kg |
| Brand | Otisience |
|---|---|
| Model | DG Series |
| Type | Online Solvent Degasser for HPLC/UHPLC Systems |
| Flow Rate per Channel | 10 mL/min |
| Max. Operating Pressure per Channel | 5 psi |
| Dimensions (W×L×H) | 86 × 278 × 155 mm |
| Weight | 6 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Channel Configurations | 2-, 3-, or 4-Channel Parallel Degassing Modules |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories and compatible with GLP/GMP workflows requiring stable mobile phase delivery |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | Packed Column |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SNFR |
| Pricing | Available Upon Request |