| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SF-3000 |
| Quotation | Upon Request |
| Control Channels | 8 or 16 |
| Operating Temperature (Controller) | −25 to +55 °C |
| Relative Humidity Range | 0–95% RH |
| Communication Interface | RS-232 (26-pin aviation connector) |
| Baud Rate | 9600 bps |
| Sensor Interface | SDI-12 (5-pin aviation connector) |
| SDI-12 Ports | 8 (expandable to 62 sensors) |
| Data Storage | USB 1.1 Full-Speed (USB 2.0 compatible) |
| Power Input | 12 VDC ±10%, ≥3 A |
| Power Output | 12 VDC ±10%, ≤1.1 A per channel |
| Enclosure Dimensions (Controller) | 16.2 × 40.7 × 28.5 cm, 5.9 kg |
| Flux Chamber Dimensions | 24 × 28 × 45 cm, 6.0 kg |
| Chamber Volume | 3100 cm³ |
| Chamber Footprint Area | 314 cm² |
| Chamber Actuation | Pneumatic (external cylinder) |
| Barometric Pressure Range | 15–115 kPa, ±1.5% accuracy |
| Chamber Temperature Range | −20 to +50 °C |
| Temperature Sensor Accuracy | ±0.5 °C |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic |
| Model | Liar Hawk |
| Pricing | Upon Request |
| Flight Platform | VTOL Fixed-Wing UAV |
| Propulsion | All-Electric |
| Endurance | 1.5 h |
| Cruise Speed | 70–80 km/h |
| LiDAR Sensor | RIEGL VUX-1LR |
| Vertical Absolute Accuracy | 5 cm @ 200 m AGL |
| Measurement Range | 5–1350 m (≥60% reflectivity) |
| Ranging Accuracy | ±1.5 cm |
| FOV | 330° |
| Scan Frequency | 10–200 Hz |
| Angular Resolution | 0.001° |
| Max Effective Point Rate | 750,000 pts/sec (@820 kHz PRR & 330° FOV) |
| GNSS Constellations | GPS, GLONASS, Galileo, BeiDou |
| Post-Processed Attitude Accuracy | 0.006° (1σ) |
| Post-Processed Heading Accuracy | 0.019° (1σ) |
| System Weight | 5.3 kg |
| Software Suite | Onboard LiDAR Control & GNSS/INS Data Processing Software |
| Optional | Point Cloud Analysis Software |
| Brand | Linde |
|---|---|
| Origin | USA |
| Manufacturer | Linde Gas (Spectra Specialty Gases) |
| Product Type | NIST-Traceable Certified Reference Material (CRM) |
| Cylinder | Aluminum Alloy, 8 × 24 cm, 104 L water volume |
| Pressure | 1800 psi (12.4 MPa) |
| Valve Interface | CGA-180 |
| Tare Weight | 0.7 kg |
| Certification | NIST-traceable gravimetric preparation |
| Uncertainty | Typically ±2% (k=2) per component |
| Concentration Options | 1 ppmv and 100 ppbv (v/v) |
| Matrix | Ultra-high-purity synthetic air (99.999% O₂/N₂ balance) |
| Compliance | EPA TO-14A, TO-15, ASTM D6420, ISO 16000-6, USP <621>, FDA 21 CFR Part 11–ready documentation |
| Shelf Life | 12 months from date of manufacture when stored upright at 20–25°C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | 907-0010, 908-0010, 911-0010, 907-0011, 908-0011, 911-0011 |
| Pricing | Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LS-MB1200MM |
| Pricing | Available Upon Request |
| Brand | Lsi |
|---|---|
| Origin | Italy |
| Model | Babuc |
| Compliance | Pre-loaded ISO/TC 159/SC5 Standards |
| Core Indices | WBGT, PMV-PPD, HIS, TTS, SWreq, Ereq, DLE, TO, CET, Ep, SWp, Wp |
| Data Acquisition | BabucM (4/6-channel) or BabucA (11-channel) Logger |
| Sensors | BSU121 Natural Ventilation Wet-Bulb Probe, BST131 150-mm Black Globe Thermometer (ISO 7726), BSU102 Forced-Ventilation Psychrometer (ISO 7726), BSV101 Hot-Wire Anemometer (ISO 7726) |
| Software | InfoGAP-Base-PC (BSZ300), InfoGAP-Advance-PC (BSZ301), Microclima Module (BSZ303) |
| Power | BSC010 Rechargeable Battery Pack (7.2 Vdc) |
| Enclosure | BWA314 Rugged Transport Case |
| Mounting | BVA304 Tripod, BVA306 Sensor & Logger Bracket, BSD020 BabucM Mount |
| Connectivity | RS-232 (9-pin male), USB-to-RS232 Adapter Optional |
| Brand | Lsi (LSI-LASTEM) |
|---|---|
| Origin | Italy |
| Model | R-Log 7730 |
| Sensor Compliance | ISO 7726, ISO 7730 |
| Wireless Data Logger Memory | 2 MB |
| Channels | 5 |
| Battery | 1.2 A Li-ion |
| Interface | Mini-DIN, RS232 |
| Operating Temperature Range | −30 °C to +70 °C |
| Black Globe Temperature Range | −20 °C to +60 °C |
| Accuracy (Globe Temp) | ±0.5 °C (5–45 °C), ±1 °C (outside range) |
| Response Time (Globe) | 30 s |
| Dry/Wet-Bulb Temp Range | −20 °C to +60 °C |
| RH Range | 0–100% |
| RH Accuracy | ±2% (10–90% RH, 25 °C) |
| RH Response Time | 8 s |
| Hot-Wire Anemometer Range | 0.01–20 m/s |
| Turbulence Intensity (TU) Range | 0–100% |
| TU & Va Accuracy | ±5 cm/s (0–0.5 m/s), ±10 cm/s (0.5–1.5 m/s), ±4% (>1.5 m/s) |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Elog-dc |
| Pricing | Available Upon Request |
| Brand | LSI-LASTEM |
|---|---|
| Origin | Italy |
| Model | R-Log 7730 |
| Sensor Compliance | ISO 7726 |
| Calculated Indices | PMV/PPD, DR, PD, TO, Tr, Pa, TU, AD (Asymmetry Discomfort) |
| Brand | LUDAHY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QPH-01 |
| Pricing | Available Upon Request |
| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | V200A-UMB |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–90 m/s |
| Accuracy | ±0.3 m/s or ±3% RMS (0–35 m/s), whichever is greater |
| Operating Temperature | −40 to +60 °C (with integrated heater) |
| Relative Humidity Range | 0–100% RH |
| Output Interfaces | Digital (RS-485, SDI-12, Modbus RTU) and Configurable Analog (4–20 mA, 0–10 V, or frequency output) |
| Measured Parameters | Wind Speed, Wind Direction, Virtual Temperature, Atmospheric Pressure, Air Density |
| Brand | Lufft |
|---|---|
| Origin | Imported |
| Model | Lufft Ventus-UMB |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–90 m/s |
| Accuracy | ±0.2 m/s or ±2% RMS (0–65 m/s), whichever is greater |
| Operating Temperature | −40 °C to +60 °C (with integrated heater) |
| Relative Humidity Range | 0–100% RH |
| Protection Rating | IP68 |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | VENTUS-X-UMB |
| Heating Function | Integrated PTC-based anti-icing system |
| Measurement Principle | Time-of-flight ultrasonic anemometry |
| Output Protocols | SDI-12, Modbus RTU, ASCII, CAN bus (configurable) |
| Environmental Certification | IP66, EN 60950-1, EN 61000-6-2/-6-3, IEC 60068-2-30 (damp heat), IEC 60068-2-14 (thermal cycling), IEC 60068-2-6 (vibration), IEC 60068-2-52 (salt mist), IEC 60068-2-31 (ice accretion test) |
| Operating Temperature Range | –40 °C to +70 °C (with active heating) |
| Wind Speed Range | 0–60 m/s |
| Wind Direction Range | 0–360° |
| Resolution | 0.1 m/s (wind speed), 1° (wind direction) |
| Accuracy | ±0.2 m/s (wind speed), ±2° (wind direction) |
| Power Supply | 12–30 V DC |
| Power Consumption | <1.5 W (standby), <4.5 W (heating active) |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS100-UMB |
| Measurement Principle | 24 GHz Doppler radar-based particle detection |
| Power Supply | DC 12–36 V (solar-compatible) |
| Operating Temperature | −40 °C to +70 °C |
| Heating Function | Integrated radar dome heater |
| Communication Protocols | Modbus RTU, SDI-12, CAN, ASCII, MQTT (optional) |
| IP Rating | IP66 |
| Maintenance | No moving parts, maintenance-free design |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4 |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS200-UMB |
| Measurement Principle | Ultrasonic time-of-flight anemometry |
| Wind Speed Range | 0–60 m/s |
| Wind Direction Range | 0–360° |
| Power Supply | 12–24 VDC, solar-compatible |
| Operating Temperature | −40 to +70 °C |
| IP Rating | IP66 |
| Communication Protocols | SDI-12, RS-232/485, Modbus RTU, CAN bus, MQTT (optional) |
| Integrated Electronic Compass | Yes |
| Heating Function | Integrated ultrasonic transducer heating |
| Output Parameters | Wind speed (m/s), wind direction (°), wind quality index (WQI), status diagnostics |
| External Sensor Support | Rain gauge, temperature/humidity probe, barometric pressure sensor |
| Compliance | CE, RoHS, WMO Guide to Instruments and Methods of Observation (CIMO) |
| Brand | Lufft |
|---|---|
| Model | WS300-UMB |
| Measurement Parameters | Air Temperature, Relative Humidity, Atmospheric Pressure, Dew Point Temperature |
| Sensor Principles | NTC Thermistor (Temperature), Capacitive Polymer (Humidity), MEMS Barometric Sensor (Pressure) |
| Power Supply | Low-power design, compatible with solar power systems |
| Enclosure | Compact, integrated, IP66-rated housing |
| Fan-Assisted Aspiration | Integrated active ventilation fan for radiation-shielded temperature/humidity measurement |
| Communication Interfaces | RS-232, RS-485, SDI-12, Modbus RTU, CAN bus, UMB-ASCII |
| Expandability | Supports external rain gauge, PT100/PT1000 temperature probes, and third-party analog/digital sensors |
| Compliance | CE, RoHS, WEEE, EN 61326-1 (EMC), EN 61000-6-2/-6-4 |
| Operating Temperature Range | –40 °C to +70 °C |
| Storage Temperature Range | –40 °C to +70 °C |
| Relative Humidity Range | 0–100 % RH (non-condensing) |
| Pressure Range | 500–1100 hPa |
| Typical Power Consumption | <1.5 W (standby), <3.2 W (fan active) |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS500-UMB |
| Measurement Principles | Ultrasonic (wind speed & direction), NTC thermistor (temperature), Capacitive polymer (relative humidity), MEMS capacitive (barometric pressure) |
| Wind Speed Range | 0–60 m/s |
| Wind Speed Accuracy | ±0.3 m/s or ±3% (0–35 m/s) |
| Wind Direction Range | 0–359.9° |
| Wind Direction Accuracy | ±3° |
| Temperature Range | −50 to +60 °C |
| Temperature Accuracy | ±0.2 °C (−20 to +50 °C), ±0.5 °C (outside range) |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2 %RH |
| Barometric Pressure Range | 300–1200 hPa |
| Pressure Accuracy | ±1.5 hPa |
| Power Supply | 24 VDC ±10%, <4 VA (unheated), 10 W max with heater |
| Output Interface | RS-485, 2-wire, half-duplex |
| Operating Temperature | −50 to +60 °C |
| Enclosure Material | Anodized aluminum |
| Weight | 1.3 kg |
| Dimensions (H × Ø) | 290 mm × 150 mm |
| Color | White powder-coated finish |
| Protocol | Lufft UMB protocol (binary/ASCII over RS-485) |
| Brand | Lufft |
|---|---|
| Model | WS501-UMB |
| Measurement Principle | Ultrasonic time-of-flight (wind speed & direction), NTC thermistor (temperature), capacitive humidity sensor (relative humidity), MEMS capacitive barometer (atmospheric pressure), thermopile pyranometer (global solar radiation) |
| Power Supply | DC 12–30 V, solar-compatible |
| Communication Protocols | SDI-12, Modbus RTU (RS-485), CAN bus, UMB-ASCII (native), optional MQTT/HTTP via gateway |
| Wind Measurement Range | 0–60 m/s (±0.1 m/s @ <5 m/s), 0–360° (±2°) |
| Temperature Range | –40 to +70 °C (±0.2 °C) |
| Relative Humidity Range | 0–100 %RH (±2 %RH) |
| Pressure Range | 500–1100 hPa (±0.5 hPa) |
| Radiation Range | 0–2000 W/m² (±5 %) |
| Operating Temperature | –40 to +70 °C |
| IP Rating | IP66 |
| Heating | Integrated ultrasonic transducer heating (–40 to +5 °C activation) |
| Fan-Assisted Aspiration | Yes, continuous low-power fan for radiation and humidity sensor thermal stabilization |
| Sensor Mounting | Integrated, single-mast mounting |
| Data Output | Real-time analog/digital, quality flags per parameter |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/-4, WMO Guide to Instruments and Methods of Observation (CIMO) Class II recommended |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | WS502-UMB |
| Measurement Principles | Ultrasonic time-of-flight (wind speed/direction), NTC thermistor (air temperature), capacitive hygrometer (relative humidity), MEMS barometric pressure sensor, photodiode-based pyranometer (global solar radiation) |
| Power Supply | 12–30 V DC, solar-compatible |
| Communication Protocols | Modbus RTU/ASCII, SDI-12, CAN bus, UMB-protocol (native), optional MQTT/HTTP via gateway |
| Environmental Rating | IP66 |
| Operating Temperature Range | –40 °C to +70 °C |
| Wind Measurement Range | 0–75 m/s (0.01 m/s resolution), Direction: 0–360° (0.1° resolution) |
| Temperature Range | –40 to +70 °C (±0.2 °C accuracy) |
| Relative Humidity Range | 0–100 %RH (±2 %RH typical) |
| Pressure Range | 500–1100 hPa (±0.5 hPa) |
| Radiation Range | 0–2000 W/m² (±5 % uncertainty) |
| Integrated Fan Aspiration | Yes |
| Heating Function | Yes (ultrasonic transducers) |
| Data Output | Real-time wind quality index (e.g., signal-to-noise ratio, data validity flags), configurable sampling interval (1 s to 10 min) |
| External Sensor Support | Rain gauge (pulse input), Pt100/Pt1000 temperature probes, analog 4–20 mA inputs |
| Brand | Lufft |
|---|---|
| Model | WS601-UMB |
| Measurement Parameters | Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Atmospheric Pressure, Precipitation |
| Principle | Ultrasonic Time-of-Flight (Wind), NTC Thermistor (Temperature), Capacitive Polymer Sensor (Humidity), MEMS Capacitive Barometer (Pressure), Tipping-Bucket Rain Gauge (Precipitation) |
| Power Supply | Low-power design, solar-compatible |
| Enclosure | Compact all-in-one housing with active ventilation fan and heated ultrasonic transducers |
| Output | Wind quality indicator, integrated electronic compass, optional external temperature probe support |
| Communication Protocols | Modbus RTU/ASCII, SDI-12, CAN bus, ASCII serial, optional MQTT/HTTP for IoT integration |
| Compliance | IP66 rated enclosure, CE marked, RoHS compliant |
| Brand | Macam |
|---|---|
| Origin | United Kingdom |
| Model | SR9910 |
| Optical Input Channels | 2 |
| Spectral Range | 240–800 nm |
| Detector Type | UV-enhanced CCD array |
| Calibration Traceability | NPL-traceable irradiance calibration |
| Sensor Compatibility | Spherical and planar irradiance sensors |
| UV Measurement Capability | Simultaneous UVA (315–400 nm) and UVB (280–315 nm) irradiance |
| Typical Applications | In-water radiometric profiling, aquatic photobiology, optical oceanography, satellite validation, water quality parameter inversion |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MCG-M60HBR |
| Pricing | Available Upon Request |
| Control System | PLC with Color Touchscreen HMI |
| Feed Form | Sealed Weighing Valve |
| Discharge Form | Dual-Density Collection System |
| Output Capacity | ≥10 Metric Tons/Year (Reduced Graphene Oxide) |
| External Dimensions | ~10 m (L) × 3 m (D) × 3.6 m (H) |
| Vacuum System | Integrated |
| Atmosphere Control | Multi-Gas Inlet Ports |
| Temperature Monitoring | Multi-Point RTD Sensors |
| Microwave Power | Adjustable |
| Safety Compliance | Microwave Leakage < GB 10436-2008 Limit |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MHX-16B |
| Frequency | 2450 MHz |
| Time Control Range | 0–99 h |
| Sample Capacity | 1 vessel |
| Temperature Range | 0–900 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Power Output | 16 kW (pyrolysis mode), 5 kW (thermal decomposition mode) |
| Chamber Volume | 66 L |
| Chamber Material | Fused quartz |
| Atmosphere Options | Vacuum or oxidizing (air-assisted) |
| Control System | PLC-based industrial automation with real-time monitoring of temperature, pressure, microwave power, and process sequencing |
| Exhaust Compliance | Meets GB 18484–2001 “Pollution Control Standard for Hazardous Waste Incineration” |
| Microwave Leakage | <5 mW/cm² (per GB 10436–2008) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Inspector Alert™ V2 |
| Detection Principle | Halogen-quenched Geiger-Müller tube with mica window (1.75" diameter, 1.5–2.0 mg/cm² density) |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Dose Rate Range | 0.01–1100 µSv/hr |
| Exposure Rate Range | 0.001–110 mR/hr |
| Count Rate | 0–350,000 CPM / 0–5,000 CPS |
| Total Count Capacity | 1–9,999,000 counts |
| Alarm Thresholds | Adjustable for µSv/hr (0–500), mR/hr (0–50), CPM (0–160,000) |
| Display | 4-digit LCD with mode indicators |
| Update Interval | 3-second rolling average (adaptive to radiation level) |
| Power | Single AA alkaline battery (≥3500 hr at background) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 323 g (incl. battery) |
| Operating Temperature | –20 °C to +50 °C |
| Certifications | CE (EN 55011:1998+A2, EN 61326:2006, EN 61000-4-2:1995, EN 61000-4-3:1997), RoHS, WEEE, ISO 9001:2001, ISO 14001 |
| Brand | Merck Millipore |
|---|---|
| Type | Stirred Cell |
| Model | Amicon® Ultrafiltration Cell (11 mL capacity) |
| Max Operating Pressure | 100 psi (6.9 bar) |
| Effective Membrane Area | 4.2 cm² |
| Sample Volume Range | 0.5–11 mL |
| Material | Anodized Aluminum Body, PTFE Seals, Stainless Steel Stir Bar |
| Compatibility | Sterilizable (Autoclavable at 121°C), Solvent-Resistant Options Available |
| Compliance | Meets ASTM D4187 and ISO 15713 for membrane performance evaluation |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Imported |
| Model | METEON 2.0 |
| Input Channels | Up to 5 smart + 1 analog Kipp & Zonen pyranometers/pyrheliometers |
| Additional Input | 1 Mencke & Tegtmeyer PV module temperature sensor |
| Display | Real-time irradiance (W/m²) and temperature (°C) |
| Communication | Modbus RTU over RS-485, analog voltage/current outputs |
| Power | Internal rechargeable battery + external 12 V DC input |
| Enclosure | IP65-rated rugged carry case with integrated mounting for sensors and cabling |
| Operating Temperature | −20 °C to +50 °C |
| Data Storage | Internal microSD card (up to 32 GB), configurable logging interval from 1 s to 24 h |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 22 |
| Resolution | 0.01 m/s |
| Wind Speed Range | 0–30 m/s |
| Wind Gust Range | 0–30 m/s |
| Wind Direction Range | 0–359° |
| Wind Direction Accuracy | ±5° |
| Tilt Range | 0–180° |
| Tilt Accuracy | ±1° |
| Dimensions | 10 cm (diameter) × 16 cm (height) |
| Cable Length | Standard 5 m (customizable) |
| Operating Temperature | −40 to +50 °C |
| Power Supply | 3.6–15.0 VDC |
| Typical Measurement Current | 0.125 mA |
| Standby Current | 0.125 mA |
| Measurement Interval | 110 ms (typical) |
| Startup Time (SDI-12 Ready) | 10 s (typical) |
| Compliance | ISO 9001:2015, ISO/IEC 17050:2010 (CE) |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 41 |
| Instrument Type | All-in-One Environmental Weather Station |
| Communication Protocol | SDI-12 |
| Power Supply | 3.6–15.0 VDC |
| Operating Temperature | −50 to +60 °C |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Dimensions | Ø10.0 cm × 28 cm |
| Compliance | CE-marked per ISO/IEC 17050:2010 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 41W |
| Instrument Type | Portable All-in-One Weather Station |
| Certifications | ISO 9001:2015, CE (EMC per ISO/IEC 17050:2010) |
| Power | 6× AA Alkaline or NiMH batteries (solar-rechargeable option available) |
| Communication | LTE-M/NB-IoT & 3G cellular (global carrier support), Bluetooth 5.2 BLE, integrated 56-channel GPS/QZSS |
| Data Storage | 8 MB non-volatile flash memory (≥100,000 records) |
| Operating Temperature | –40 °C to +60 °C (RH & barometric sensors functional at –40 °C |
| extended air temperature range | –63 °C to +60 °C) |
| Dimensions | 16.5 cm (W) × 31.8 cm (H) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ProCheck |
| Pricing | Upon Request |