Other Environmental Monitoring Instruments
Filter
Showing 1021–1050 of 1326 results
| Brand | PKSAIR |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PKSAIR C510 |
| Pricing | Available Upon Request |
| Brand | PKSAIR |
|---|---|
| Origin | Japan |
| Model | COM-3200PRO II |
| Detection Principle | Coaxial Double-Cylinder Capacitor Method (JIS Draft Standard) |
| Measurement Range | 0–20,000 ions/cm³ (R1), 0–200,000 ions/cm³ (R2), 0–2,000,000 ions/cm³ (R3) |
| Display | 7-segment, 4½-digit LCD |
| Power Supply | AC 100–240 V + Rechargeable Internal Battery (≥7 h operation) |
| Dimensions | 45 × 112 × 188 mm (W × D × H, excluding protrusions) |
| Weight | 0.995 kg |
| Environmental Sensors | Integrated Temperature (5–35 °C) and Relative Humidity (0–85 %RH) |
| Drift Stability | ±5 % |
| Data Interface | RS-232 port, included RS-232-to-USB adapter |
| Software | English-language PC analysis software with data logging, time-stamped export, and report generation |
| Compliance | Designed per JIS Draft Guideline for Air Ion Density Measurement |
| Accessories | Carrying case, RS-232 cable, RS-232-to-USB adapter |
| Brand | PKSAIR |
|---|---|
| Origin | Japan |
| Model | COM-3700 |
| Measurement Principle | Gerdien Capacitor Method |
| Ion Polarity | Simultaneous Positive & Negative Ion Detection |
| Mobility Range | 0.00269 – 5.38 cm²/V·s (equivalent to ~2000 cm²/V·s in standard mobility scale) |
| Measurement Modes | Auto (dual-polarity) and Manual (single-polarity) |
| Concentration Range | R1: 0–8,000 ions/cm³ |
| R2 | 0–50,000 ions/cm³ |
| R3 | 0–500,000 ions/cm³ |
| R4 | 0–5,000,000 ions/cm³ |
| Display | 16-character × 2-line STN LCD with backlight and ON/OFF control |
| Data Logging | Internal memory for time-stamped measurements |
| Interface | RS-232C output for PC connectivity |
| Compliance | Designed for field-deployable environmental ion monitoring per JIS B 7951 and ISO 16000-22 (indoor air quality — measurement of airborne ions) |
| Brand | PKSAIR |
|---|---|
| Origin | Japan |
| Model | COM3200PROII |
| Detection Principle | Coaxial Double-Cylinder Capacitive Electrometer |
| Measurement Range | 0–2×10⁶ ions/cm³ (3-range auto-scaling) |
| Display | 7-segment, 4½-digit LCD |
| Power Supply | AC 100–240 V + rechargeable internal battery (≥7 h operation) |
| Dimensions | 45 × 112 × 188 mm (W×D×H, excl. protrusions) |
| Weight | 0.995 kg |
| Operating Environment | 5–35 °C, 0–85 % RH |
| Drift | ±5 %/24 h |
| Built-in Sensors | Temperature & Relative Humidity |
| Interface | RS-232 (with USB adapter included) |
| Compliance | JIS B 7751 Draft Standard for Air Ion Density Measurement |
| Data Software | Windows-compatible analysis software with logging, graphing, and export (CSV/PDF) |
| Brand | PKSAIR |
|---|---|
| Origin | Beijing, China |
| Model | PKSAIR-5200 |
| Detection Principle | Geiger-Müller (GM) Tube-based Ionization Measurement |
| Range | 0.00–100,000 ions/cm³ |
| Resolution | 1 ion/cm³ |
| Accuracy | ≤ ±5% |
| Sampling Method | Passive Electrostatic Induction + GM Tube Detection |
| Display | 2-inch HD LCD (English/Chinese bilingual firmware) |
| Power | Rechargeable 800 mAh Li-polymer battery (up to 50 h continuous operation) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Dimensions | 144 × 78 × 33 mm |
| Weight | 0.36 kg |
| Compliance | Intrinsic Safety Circuit Design |
| Connectivity | Micro-USB (5 V DC charging) |
| Brand | PowerEach (Shanghai Zhongchen Digital Technology Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JXWNP-WJS-1 |
| Pricing | Available Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PRI-2012 |
| Pricing | Available Upon Request |
| Chamber Type | Dark (Aluminum) / Transparent (Acrylic) |
| External Dimensions | 44 × 26 × 26 cm (L×W×H) |
| Chamber Internal Diameter | 20 cm |
| Chamber Height | 13 cm (adjustable |
| Measurement Volume | 4500 cm³ (customizable) |
| Measurement Area | 350 cm² (customizable) |
| Operating Principle | Dynamic Pressure-Balanced Flow-Through Method |
| Actuation | Stepper Motor |
| Control Unit | Embedded Microcontroller |
| Interface | Aviation Connector (MIL-DTL-5015 compliant) |
| Weight | ~5.0 kg (including handle) |
| Environmental Rating | IP65-equivalent (curved housing, dust- and water-resistant design) |
| Remote Operation | Bluetooth/WiFi-enabled mobile app (iOS/Android) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CRS-2000C |
| Price | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CRS-2000S |
| Pricing | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | METLOG 2000 |
| Instrument Type | Portable Weather Station |
| CPU | 32-bit, 300 MHz |
| Data Storage | 64 MB (expandable to 32 GB) |
| Wind Speed Range | 0–60 m/s |
| Wind Direction | 360° continuous, ±3° accuracy |
| Relative Humidity Range | 0–100% RH (±2% @ 0–90%, ±3% @ 90–100%) |
| Air Temperature Range | −80°C to +75°C (±0.1°C accuracy) |
| Atmospheric Pressure Range | 500–1200 hPa (±0.3 mbar) |
| Global Solar Radiation | ±5% calibration uncertainty, 90 µA per 1000 W·m⁻², linearity ≤1% up to 3000 W·m⁻², response time: 10 µs |
| Soil Temperature Range | −50°C to +50°C (±0.2°C) |
| Soil Moisture Range | 0–100% volumetric water content (±3% accuracy) |
| Rainfall Resolution | 0.25 mm (0.01 in), accuracy <1.0% @ 50.8 mm/h |
| Digital Magnetic Compass | ±1° heading accuracy (at 25°C, 0° heel), 0.1° resolution |
| Enclosure | Spark-proof anodized aluminum housing with dual O-ring sealing |
| Communication | Embedded RJ45 Ethernet interface, cable-free modular architecture |
| Surge & Lightning Protection | Integrated galvanic isolation per channel, TVS and MOV protection |
| Power | Optional 40 W solar panel support |
| Mounting | Corrosion-resistant aviation-grade aluminum tripod, <60 s deployment |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | METLOG |
| Instrument Type | Portable Weather Station |
| CPU | 32-bit, 300 MHz |
| Data Storage | 64 MB (expandable to 32 GB) |
| Ultrasonic Anemometer | Wind Speed 0–60 m/s, Accuracy ±0.2% |
| Relative Humidity | 0–100 % RH, Accuracy ±2 % (0–90 %), ±3 % (90–100 %), Resolution 1 % RH |
| Air Temperature | −80 to +75 °C, Accuracy ±0.1 °C |
| Atmospheric Pressure | 500–1200 hPa, Accuracy ±0.3 mbar |
| Global Solar Radiation | Calibration Uncertainty ±5 %, Sensitivity ~90 µA/(1000 W·m⁻²), Linearity <1 % up to 3000 W·m⁻², Response Time 10 µs |
| Soil Temperature | −50 to +50 °C, Accuracy ±0.2 °C |
| Soil Volumetric Water Content | 0–100 %, Accuracy ±3 % |
| Rainfall | Resolution 0.25 mm, Accuracy <1.0 % at 50.8 mm/h, Orifice Diameter 15.4 cm |
| Soil Heat Flux | Sensitivity ~50 µV/(W·m⁻²), Nominal Resistance 2 Ω, Range ±2000 W·m⁻², Temp. Dependence <0.1 %/°C |
| Infrared Surface Temperature Sensor | Range −40 to +70 °C, FOV Half-Angle 22°, Accuracy ±0.2 °C (−10 to +65 °C), ±0.5 °C (full range) |
| Brand | Pri-eco |
|---|---|
| Model | PRENART |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Vacuum Range | –850 mbar |
| Compressor Output | 2.5 bar |
| Pumping Speed | 7.2 L/min at 0 bar |
| Power Supply | 12 V / 3.4 Ah |
| Power Consumption | 22 W |
| Dimensions | 300 × 200 × 180 mm |
| Weight | 5.6 kg |
| Ingress Protection | IP65 |
| Manual Vacuum Pump Displacement | 36 cm³/stroke |
| Sampler Probe Material | PTFE + quartz powder or stainless steel powder |
| Probe Outer Diameter | 21 mm |
| Probe Length | 95 mm |
| Probe Weight | 50 g |
| Porous Surface Area | 33 cm² |
| Hydraulic Conductivity | 3.31 × 10⁻⁷ cm/s |
| Bubble Point Pressure | >500 mbar |
| Water Extraction Rate | 6 mL/cm²/hr at 600 mbar |
| Pore Size | 2 µm |
| Brand | PRI-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PRI-330 |
| Pricing | Available upon Request |
| Brand | PRI-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PRI-8500 |
| Pricing | Available Upon Request |
| Sampling Ports | 8 standard (expandable) |
| Inlet Flow Control | Manual adjustment |
| Inlet Fitting | 1/4" push-to-connect |
| Exhaust Fitting | 1/4" or 1/8" compression |
| Multiport Valve | VICI (USA) |
| Communication Interface | RS232 serial port |
| Dimensions | 52.4 × 42.8 × 20.6 cm |
| Weight | <7 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max Power Consumption | <50 W |
| Overcurrent Protection | Integrated |
| Enclosure Material | Pelican™-grade engineered polymer (IP65-rated, shock-absorbing, weather-resistant) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PRI-XRF1 |
| Pricing | Available Upon Request |
| X-ray Tube | Integrated End-window Tube (65 kV / 100 W) |
| Detector | Factory-Integrated Fast Silicon Drift Detector (SDD), Energy Resolution ≤125 eV (Mn Kα, 5.889 keV) |
| Detection Limits (3σ) | Hg 0.39 ppm, As 0.42 ppm, Pb 0.72 ppm, Cd 0.16 ppm, Cr 2.20 ppm, Ni 1.56 ppm, Cu 1.38 ppm, Zn 0.93 ppm |
| Quantification Limits (10σ) | Hg 1.31 ppm, As 1.41 ppm, Pb 2.39 ppm, Cd 0.54 ppm, Cr 7.32 ppm, Ni 5.19 ppm, Cu 4.58 ppm, Zn 3.09 ppm |
| Elemental Range | ppm to 99.99 wt% |
| Minimum Measurement Time | 30 s |
| Power Supply | Rechargeable Li-ion Battery (DC 12 V) |
| AC Input | 220 ±22 V, 50/60 Hz |
| Battery Life | 8–10 h |
| Connectivity | 4G Cellular Data Transmission |
| Radiation Safety | Triple-layer X-ray Protection (Mechanical Maze + Electronic Interlock + Software-Based Beam Termination), Compliant with GBZ 115–2002 and IEC 61010-1 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | δ13C Continuous Measurement System |
| CO₂ Detection Limit | ≤1 ppm |
| δ¹³C Precision | ≤0.3 ‰ |
| Temperature Range | –5 to 35 °C |
| Temp. Control Accuracy | ±0.15 °C |
| Channel Capacity | 16 parallel incubation vessels |
| Max. Uninterrupted Operation | 30 days |
| Vessel Volume | 50 mL |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solus HCl |
| Pricing | Upon Request |
| Brand | PULUODY |
|---|---|
| Model | PMT-2DRD |
| Detection Principle | Capacitive Sensing with Dual-Laser Narrow-Beam Optical Verification |
| Detection Range | 0.5–20.0 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Repeatability | 5% |
| Power Input | 100–265 VAC, 50–60 Hz |
| Output Interface | 4–20 mA analog signal with configurable particle concentration alarm |
| Compliance Standards | JJG 1061, ISO 21501-4, USP <788> & <789>, ASTM F3232 |
| Software Platform | PULUODY V8.3 Integrated Analysis Suite (PC & tablet-compatible) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Sample Delivery | Precision metering piston pump with electromagnetic flow regulation |
| Data Output | Particle count per mL and ISO 4406 / NAS 1638 contamination code reporting |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QDF-6 |
| Price Range | USD 140–280 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–30 m/s |
| Accuracy | ≤3% of full scale |
| Operating Temperature | 0–50 °C |
| Response Time | ≤3 s |
| Display | 4-digit LCD |
| Power Supply | DC 5–6 V (rechargeable battery supported) |
| Dimensions | 190 × 90 × 40 mm |
| Weight | 380 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantus HP100 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantus LP100 |
| Pricing | Available Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | QUESTemp |
| Certification | Intrinsically Safe Options Available |
| Sensor Technology | Traditional Wet-Bulb (Models 32/34/36) or Waterless Wet-Bulb (Models 44/46/48N) |
| Compliance | Meets ISO 7243, ACGIH TLV®, OSHA & NIOSH Heat Stress Guidelines |
| Protection Rating | IP54 |
| WBGT Calculation Method | Weighted combination of natural wet-bulb, globe, and dry-bulb temperatures |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05103 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±0.3 m/s or ±1% of reading |
| Operating Temperature | −50°C to +50°C |
| Relative Humidity Range | 0–100% RH |
| Startup Wind Speed (Propeller) | 1.0 m/s |
| Startup Wind Speed (Vane) | 1.1 m/s |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC (05103V), or 4–20 mA (05103L) |
| Power Supply | 15 VDC (sensor only) |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor), 2.3 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05106 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Relative Humidity Range | 0–100% RH |
| Wind Direction Range | 360° mechanical, 355° electronic (5° dead zone) |
| Wind Direction Accuracy | ±3° |
| Startup Wind Speed | 1.0 m/s (propeller), 1.1 m/s (vane) |
| Output | Magnetic pulse (3 pulses/rev) for wind speed |
| Power Supply | 15 VDC excitation (sensor) |
| Dimensions | 55 cm length × 37 cm height × 18 cm propeller diameter |
| Mounting | Standard 1-inch NPT pipe thread |
| Weight | 1.0 kg (sensor only), 2.3 kg (shipping) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05108 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Bearing Material | Ultra-durable ceramic |
| Output | Magnetic pulse (3 pulses/rev, 1 rev = 0.5 m air travel) |
| Propeller Diameter | 18 cm |
| Sensor Height | 40 cm |
| Total Length | 57 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Weight | 1.0 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05108-45 |
| Instrument Type | Cup Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +60°C |
| Operating Humidity | 0–100% RH |
| Bearing Material | High-Wear-Resistant Ceramic |
| Output Signal | Magnetic pulse (3 pulses per revolution |
| Propeller Diameter | 18 cm |
| Overall Height | 40 cm |
| Length (including propeller) | 57 cm |
| Mounting Tube Diameter | 34 mm (1-inch standard pipe) |
| Weight | 1.0 kg |
| Ice-Resistant Coating | Yes |
| Color Finish | Matte Black (enhances solar heating for passive de-icing) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05305 |
| Instrument Type | Cup Anemometer & Wind Vane Sensor |
| Resolution | 0.1 m/s |
| Measurement Range | 0–50 m/s (wind speed), 0–360° (wind direction) |
| Accuracy | ±0.2 m/s or ±1% of reading (wind speed), ±3° (wind direction) |
| Startup Wind Speed | 0.4 m/s (cup), 0.5 m/s (vane) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Options | AC pulse (3 pulses/rev), 0–5 VDC, or 4–20 mA |
| Housing Material | UV-stabilized polymer with stainless steel and anodized aluminum hardware |
| Bearing Type | Precision stainless steel ball bearings |
| Compliance | EPA PSD Guidelines, NRC RG 1.23, ANSI/ANS-18.1 |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 05501LM |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s (continuous), 0–50 m/s (rated), 100 m/s (gust) |
| Accuracy | ±0.3 m/s or ±1% of reading (wind speed), ±3° (wind direction) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output | Dual 4–20 mA (wind speed: 0–50 m/s standard, 0–100 m/s optional |
| wind direction | 0–360°) |
| Power Supply | 8–30 VDC, ≤40 mA |
| Startup Velocity | 1.0 m/s (propeller), 1.1 m/s (vane) |
| Dynamic Response | Propeller distance constant 2.7 m, vane lag distance 1.3 m, damping ratio 0.3 |
| Construction | Stainless steel shaft & bearings, anodized aluminum housing, UV-stabilized polymer components |
| Mounting | Standard 1-inch NPT pipe thread (34 mm OD) |
| Sensor Weight | 1.0 kg |
| Shipping Weight | 2.3 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 09101 |
| Instrument Type | Propeller Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–100 m/s |
| Accuracy | ±2% of reading or ±0.3 m/s (whichever is greater) |
| Operating Temperature | −50°C to +50°C |
| Operating Humidity | 0–100% RH |
| Output Interface | RS-485 serial (RMY/NCAR/NMEA protocols) |
| Startup Wind Speed | 1.0 m/s |
| Bearing Type | Precision stainless steel ball bearing |
| Mounting | Standard 1-inch NPT pipe thread |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 73000 |
| Weight | 8 kg |
| Operating Temperature | -40 to +60 °C |
| Supply Voltage | 10–36 VDC |
| Measurement Range | 30 m – 16 km |
| Accuracy | ±10% RMSE |
| Time Constant | 60 s |
| Scattering Angle | 42° (nominal) |
| Output Options | 0–10 VDC |
| Relay Options | 2 control relays, 1 diagnostic relay |
| Power Consumption | 6 VA (nominal), 18 VA (with heated shroud) |
| Ingress Protection | IP66 (NEMA-4X) |
| Dimensions | 889 mm × 292 mm × 305 mm (W × H × D) |
| Mounting | 48 mm (1.9″) for 1.5″ IPS pipe (standard), optional 34 mm (1.3″) for 1″ IPS pipe |
| Housing Material | Anodized aluminum frame, UV-stabilized fiberglass enclosure |
| Compliance | EN 61326-1:2010, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU |